Kenmore 58052450200 User Manual DEHUMIDIFIER Manuals And Guides L1004053
KENMORE Dehumidifier Manual L1004053 KENMORE Dehumidifier Owner's Manual, KENMORE Dehumidifier installation guides
User Manual: Kenmore 58052450200 58052450200 KENMORE DEHUMIDIFIER - Manuals and Guides View the owners manual for your KENMORE DEHUMIDIFIER #58052450200. Home:Heating & Cooling Parts:Kenmore Parts:Kenmore DEHUMIDIFIER Manual
Open the PDF directly: View PDF .
Page Count: 13
Download | |
Open PDF In Browser | View PDF |
Owner's Manual Manual del Propietario ® DEHUMIDIFIER DESHUMIDIFICADOR Model, Modelo 580.52450 k= Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com TABLE OF CONTENTS 2 AUTOMATIC SHUT OFF .............................. 8 .................................................. 2 ........................................................ 3 REMOVING AND EMPTYING THE WATER BUCKET .................................. 8 MAINTENANCE ............................................ 9 Grille and case ......................................... 9 Air filter ..................................................... 9 9 WARRANTY SAFETY ................................ Important Safety Instructions ...................... ELECTRICAL REQUIREMENTS OPERATION 3 .................. 4 ................................................. 5 Features ................................................... 5 Cleaning Control Panel ........................................... 6 General INSTALLING YOUR DEHUMIDIFIER CHOOSING THE PROPER LOCATION cleaning ...................................... 9 Water bucket cleaning .............................. .............. 7 Defrost control .......................................... inside the unit ............................ TROUBLESHOOTING 7 REPAIR ....... 7 ESPANOL SERVICE FULL ONE YEAR WARRANTY ................................ PARTS .......................................... ................................................... NUMBERS 9 10 11 14 ................... Back Cover ON DEHUMIDIFIER For one year from the date of purchase, if the Dehumidifier is operated and maintained according to the owner's instructions furnished with the product, Sears will repair the Dehumidifier free of charge, if defective in materials or workmanship. FULL FIVE YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM For five years from the date of purchase, when this Dehumidifier is operated and maintained according to owner's instructions furnished with the product, Sears will repair the sealed refrigeration system (consisting of refrigerant, connecting tubing, and compressor motor) free of charge, if defective in material or workmanship. WARRANTY SERVICE IS AVAILABLE BY RETURNING UNIT TO THE NEAREST SEARS SERVICE CENTER IN THE UNITED STATES. CALL 1-800-4-MY-HOME ® FOR NEAREST SERVICE CENTER This warranty This warranty state. TO YOU. applies only while this Dehumidifier is used in the United States. gives you specific legal rights, and you may also have other rights which vary from state to Sears, Roebuck and Co., D/817WA, Hoffman Estates, IL 60179 U.S.A. 2 IMPORTANT SAFETY INSTRUCTIONS The safety instructions below will tell you how to use your dehumidifier or damage to your dehumidifier. ELECTRICAL FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity this or any other appliance. Read product labels for flammability and other warnings. PREVENT TO redu_ requirements. , Be sure the dehumidifier is properly grounded. To minimize shock and fire hazards, proper grounding is importanL The power cord is equipped with a three-prong shock, or grounding hazards. injury to persons when using your dehumidifier, follow basic precautions., including the following: • Be sure the electrical service is adequate the model you have chosen. plug for protection against shock • Your dehumidifier must be used in a properly grounded wall receptacle, If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. for • Do not use an extension Avoid fire hazard or etectric shock. Do not use an extension cord or an adapter plug Do not remove any prong from the power cord. Grounding type wall receptacle INFORMATION The complete electrical rating of your new dehumidifier is stated on the serial plate Refer to the rating when checking the electrical of ACCIDENTS the risk of fire, electrical to avoid harm to yourself adapter Do not under any circumstances cut, remove, or bypass the grounding prong from this p_ug. Power supply _rd with 3-prong grounding plug -3- plug. cord or an OBSERVE ALL LOCAL ORDINANCES, CODES AND DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG. ELECTRICAL GROUND THIS APPLIANCE. IS REQUIRED ON A 1 !5-volt 60 Hz, AC only, 15A fused and properly grounded electrical supply is required. A time delay fuse or time delay circuit breaker is recommended. Use a dedicated circuit, Electrical serving only this appliance. Do not use an adapter. DO NOT USE AN EXTENSION Piug into a grounded GROUNDING For your personal safety, this appliance 3 prong outlet. Do not remove ground prong. Do not use an extension CORD. RECOMMENDED Shock Hazard cord. Failure to follow these instructions METHOD in death, fire, or electrical must be grounded. This appliance has a power supply cord with a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code (ANSliNFPA 70) latest edition and all local codes and ordinances, if a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded 3-prong walll receptacle installed by a quaJified electrician. -4- supply cord shock. can result To reducethe risk offire,electricshock,or injuryt:opersons,readthe impo_antSAFETY instructionssectionbeforeoperatingthis appliance. 1.Controlpanel 2. Frontgrille 3. Powercord 4, Cabinet 5, Airfilter 6.Waterbucket 2 IMPORTANT: Whenunitis firstpluggedin or aftera poweroutage,therewill be a 2 minutedelaybeforeoperation begins. 5 6 -5- CONTROL PANEL Your dehumidifier Control, Humidi_ control panel contains a Bucket: Full indicator, a Humidity Control, Fan Speed Control and Timer Control. indicator, a Power Bucket Full indictor ---This light:glows when the water bucket: is full and needs to be emptied. Power -- Operation star_ when this button is pressed and stops when the but_n is pressed again, Humidi_ Control --- This button controls the humidity in the r_m, • : To raise the humidi_ setting • : To lower the humidity' setting , The humidity can be set within a range of 40% RH(Relative Humidity)~70% RH(Relative Humidity) by 5% increments, Fan Speed .... This controls the speed of the airflow. - High: Fan speed is set to high. • Low: Fan speed is set to low. • When Fan Speed button is pressed, the fan speed mode is changed, Energy Timer .... Pressing this button will make the unit go into automatic On/Off mode In this mode the unit will be On for 3 or 6hrs and then it will automatically _rn off for 3 or 6hrs. After that it will turn on again and this cycle will be repeated continuously. (Constant button will make the unit run continuously under normal humidity conditions.) • The Timer can be set for: Constant, 6 Hr. On/Off or 3 Hr. On!Off • When Timer button is pressed, the Timer indicator lights shift as follows: Constant _ 3 Hr. On/Off _ 6 Hr. On!Off _ Constant Auto Restart TO OPERATE --- In case the power comes on again after a power failure, Auto Restart Operation is the function to operate proc_ures automatically to the previous operating conditions. So there is no need of activating this function by pressing any key or button. THE DEHUMIDIFIER: 1.. Plug the power cord into an electrical outleL Press the power button. 2. Set the, Humidity Control anywhere bei_ween40% RH(Relative Humidity) and 70% RH(Relative Humidity) for normal operation_ if you need drier air, press the Humidity Control button. If you need less moister air, press the Humidi_ Control button 3. Press the Power button to stop the unit manually. 4. Press the Timer button to set the amount of time you want the unit to run, At the end of that time, the unit will shut off. The Timer can be set for : Constant, 6 hours or3 hours. 5. If you want to control the speed of airflow, press Fan Speed button. Each time that the Fan Speed button is press_, the fan speed mode is shifted: High _ Low -,-)High Note: Be careful not to lose the water bucket. This dehumidifier doesn't run if the water bucket is not installed properly. -6- • Installthe dehumidifieron a levelfloorstrong enoughto supportthe unitwith a full bucket of water. • Forbest performance,allowat least12-18 inchesofair spaceon all sidesof the unitfor goodair circulation. • Keepalloutsidedoors,windows,andother openingsclosedwhenoperatingthe dehumidifier.Humidoutdoorairwil!addto the unit'sworkload. • Install your dehumidifier in an area where the temperature will not fall below 65_ (18_). At temperatures below this, the coils can become covered with frost, which may reduce dehumidifying performance. DEFROST CONTROL When the defrost control senses frost build-up on the evaporator coil, it will automatically shut off the compressor. The fan will continue to run to draw air across the coil and melt the frost. When the coil is defrosted, the compressor automatically restart and dehumidifying resume, • Use the dehumidifier in a basement prevent moisture damage. will to help • Use the dehumidifier in cooking, laundry, bathing, and dishwashing areas that have excessive moisture. , Use the dehumidifier to prevent moisture damage anywhere books or valuables are stored. -7- !2~18" Whenthebucketis full,orwhenthebucketis notin theproperposition, the Bucket Ful! bight turns on and the unit automatically shuts off. Also, when bucket is out of position, the unit will beep 3 times. me bucket must _ replaced in the proper position for the dehumidifier to work. The light will be on and the dehumidifier will not run if the bucket is not in the pro_r position. The water bucket can be emptied in one of three ways: Empty the bucket manually. Pla_ When the bucket is full, dir_tly remove and empty it into a large sink or tub. When finished, replace it properly. The bucket has a threaded hose connection which can be conn_tion to carry water to the drain. (HAND TIGHTENONLY) left open. Drill a 1/4" (6.4ram) to 1/2"(13mm) hole in the center of the hose connection. Be sure the hose doesn't kink or bend it should lie fiat from the dehumidifier to the drain, NOTE: To replace the bucket properly, make sure the slots on the back of bucket are positioned correctly. the dehumidifier over drain. Once opened, the hose connection will continually drain water from the bucket -8- Attach a garden ho_ to the thread_ bucket drain hose GRILLE AND CASE To clean the case: Use water and a mild detergent. cleaner. Do not use bleach or an abrasive To clean the grille: Use a vacuum with an attachment or brush. AIR FILTER The air filter is on the back of the dehumidifier. It should be checked and cleaned at least every 30 days or more often if necessary. TO REMOVE: Flex the filter at the lower right corner and slide the upper right side to the left. Release all of the tabs and remove the filter. Wash it in warm soapy water. replacing it. Rinse and let the filter dry before CLEANING INSIDE THE UNIT After removing the air filter, clean the coil on the inside with a soft brush to remove any soft and wet soil. NOTE: Do not allow water to enter the electrical/machine compartment through the circular opening behind the coil. Do not spray the coil with a hose. GENERAL CLEANING • Dust the front grille and the side panels with a soft brush or use the dusting attachment of your vacuum. • If cabinet paint chips, you can touch up the paint with a good grade enamel to prevent rust. WATER BUCKET CLEANING 1 • Every few weeks, rinse the inside of the water bucket with a mild detergent to prevent growth of mold, mildew, and bacteria. -9- Dehumidifier does not start The dehumidifier power cord is unplugged • Make sure the dehumidifier completely into the outlet. The fuse is blown or circuit • Check the house fuse or circuit breaker break_ is tripp_, plug is pushed box and replace the fuse or reset the breaker Water bucket is full . The dehumidifier automatically turns off when this occurs. Empty the bucket. Bucket is not installed, • Make sure the bucket is in the right place, Dehumidifier Did not allow enough time • When first installed, atlow at least 3 or 4 does not dry the air as it should to remove the moisture, Airflow is restrictS, days to maintain the desired dryness. __ • Make sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier. The Humidity Control may not be set low Humidity, • Press the Humidity lower the humidity, Doors and windows may not be cloud tightly, • Check that all doors, windows and other openings are securely closed. Clothesdryer my be blowing _isture-laden air into the room. • Install the dehumidifier away from the dryer. The dryer should be vented to the outside. Room temperature low. • The unit will not operate satisfactorily if the room temperature is below 65°R (18_,). is too Area to be dehumidified is Dehumidifier too much Frost appears the coils runs on Control huron to too la_e. • Check with your dealer to see if the capacity is adequate. Doo_ and windows are open. • CIose all doors and windows Dehumidifier • This is normai, Frost will usually disappear within 60 minutes, has been recently turn_ on or room temperature is below 65 _. to the outside. (18_.). Fan noise Water on floor Air is moving through the dehumidifier. ° This is normal. Bucket d_in • Check the hose if one is attached, hose connection may be loose, Water bucket is not all the -10- • See Removing Bucket. and Emptying The Water Dehumidifier To order Parts call Toll Free Model No. 580.52450 1-800-4-MY-HOME_(1-800-469-4663) NOTE: Use the Kenmore part number on all orders, not the illustration number. OUTER CASE PARTS AND CONTROL PART i. --6-A --7°A 11°A 16-A 4-A 14-A 13-A 12oA ILL,_. PART'NUMBER DESCRIPTION iLL._. PARTNUMBER DE_RI_ION 1-A 3041AD2007C BASEASSEMBdlWELD[SINGLE] 11-A 5230AD3005A FILTER, AIR 2-A 4791A10002B BARRIER, ASSEMBLY 12-A 3530A10006F GRILLE, FRONT 3-A 6600A30003C SWITCHASSEMBLY,MICRO 13-A 4838A20005A TANK, BUCKET 4-A 3090A10001 R CABINET 14-A 3831A20016B ESCUTCHEON 5-A 6877A30013D SENSOR ASSEMBLY 15-A 3551A30030C COVERASSEMBLY,DISPLAY 6-A 4995A10051A CONTROLBOX,ASSEMBLY 16-A 6411A20001V POWER CORD ASSEMBLY 7oA 6871A20162A PWB ASSEMBLY, MAIN 8-A 0CZZA20001Q CAPACITOR, DRAWING 9-A 4H00442J CLAMP, CAPACITOR -11 - 580.52450 NOTE: When ordering parts, use the Kenmore part number not the illustration number. CYCLE PARTS 6-B 5-8 ILL. NO. PART NUMBER DESCRIPTION 1 -B 5900A20007A FAN 2-B 4999A10001C 3-B 4681A20040C 4-B 4960A20009A MOUNT, 5-B 5403A10008D CONDENSER 6-B 5421A10009F EVAPORATOR SHROUD MOTOR -12- ASSEMBLY ASSEMBLY, SINGLE MOTOR ASSEMBLY ASSEMBLY 580,52450 NOTE: When ordering parts, use the Kenmore part number _ COMPRESSOR the il+ustrationnumber. PARTS 2-C 9_C 3-C 4-C 11 -C 5+C € 10°C 6-C 7C 8-C ILL. NO. PART NUMBER DESCRIPTION 1 -C 4H00947A 2+C 3550U+L004A 3-C 6750U+L039A O.LP 4-C 4986U-L001G GASKET 5-C 2520UABC2FA COMPRESSOR 6-C 1 NHA0801206 NUT, HEXAGON 7-C 4810AR4155A 8-C 4830A30005A 9-C 5211 A10209A 10-C 5211A10231A 11 -C 52! 1A10085H NUT, TERMINAL TERMINAL BRACKET, COVER COVER WASHER BUSH+NG TUBE ASSEMBLY, TUBE ASSEMBLY, TUBE ASSEMBLY, -13- SUCTION DISCHARGE CAPILLARY
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 13 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Sat Mar 29 12:54:46 2014 Author : Title : Subject :EXIF Metadata provided by EXIF.tools