Kenmore 58073083300 User Manual AIR CONDITIONER Manuals And Guides L0306050
KENMORE Air Conditioner Room (42) Manual L0306050 KENMORE Air Conditioner Room (42) Owner's Manual, KENMORE Air Conditioner Room (42) installation guides
User Manual: Kenmore 58073083300 58073083300 KENMORE AIR CONDITIONER - Manuals and Guides View the owners manual for your KENMORE AIR CONDITIONER #58073083300. Home:Heating & Cooling Parts:Kenmore Parts:Kenmore AIR CONDITIONER Manual
Open the PDF directly: View PDF .
Page Count: 40
Download | |
Open PDF In Browser | View PDF |
Owner's Manual Manual del Propietario ® THROUGH-THE-WALL AIR CONDITIONER ACONDICIONADODEAIRE A TRAVESDE PARED Model, Modelo 580.73083 580.74103 Sears, Roebuck and Co., Hoffman www.sears.com 580.74123 Estates, IL 60179 U.S.A. TABLE OF CONTENTS 13 ..............................................2 Using the Air Conditioner ....................... 13 .....................................................3 Air Conditioner Features ........................ 14 WARRANTY SAFETY Features ................................................. ........................2 MAINTENANCE ImportantSafety Instructions...................... 3 ELECTRICAL REQUIREMENTS INSTALLATION .......4 ..................................... 17 Air Filter Cleaning ................................... 17 Air Conditioner Cleaning ........................ 17 ........................................5 How to Remove the Front Grille ............. 17 Installation Requirements ......................... 5 Installation ................................................ 6 Procedure A ............................................. 7 Procedure B ............................................. 9 Procedure C .......................... How to Replace the Front Grille ............. 17 TROUBLESHOOTING ......................... 18 Before Calling for Service ...................... 18 11 ESPAI_IOL ........................................... 12 How and Why ......................................... 12 MASTER PROTECTION AGREEMENTS ......................................39 Normal Sounds ...................................... 12 OPERATION ._............... SERVICE ................................................ NUMBERS ............Back Cover Capacity and Running Time ................... 12 WARRANTY SERVICE IS AVAILABLE BY CONTACTING SEARS SERVICE AT 1-800-4-MY-HOME ®. FULL ONE YEAR WARRANTY ON THROUGH-THE-WALL AIR CONDITIONER For one year from the date of purchase, when this air conditioner is operated and maintained for normal room cooling according to instructions in this owner's manual, Sears will repair this air conditioner, free of charge, if defective in material or workmanship. FULL FIVE-YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM Warranty coverage applies only to air conditioners used for non-commercial, private household purposes. This warranty applies only while this product is in use in the United States. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For five years from the date of purchase, when this air conditioner is operated and maintained for normal room cooling according to instructions in this owner's manual, Sears will repair the sealed refrigeration system (consisting of refrigerant, connecting tubing, and compressor), free of charge, if defective in material or workmanship. Sears, Roebuck and Co., D/817WA, Hoffman Estates, IL 60179 U.S.A. -2- 2o IMPORTANT SAFETY INSTRUCTIONS The safety instructions below will tell you how to use your room air conditioner to avoid harm to yourself or damage to your ROOM AIR CONDITIONER. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings. PREVENT _ Avoid fire hazard or electric shock. Do not use an extension cord or an adapter plug. Do not remove any prong from the power cord. Grounding type walkreceptacle ACCIDENTS To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following: • Be sure the electrical service is adequate for the model you have chosen. • If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a triple-track type with a screen panel included, you may want to remove the screen completely before installation. • Be sure the air conditioner has been securely correctly installed according to the instructions this manual. Save this manual and installation instructions possible future use in removing or reinstalling unit. Do not under any circumstances cut, remove, or bypass the grounding prong from this plug. P°wet;,%;o Zr grounding plug and in ENERGY SAVING IDEAS for this • The capacity of the room air conditioner must fit the room size for efficient and satisfactory operation. • Use gloves when handling the air conditioner. Be careful to avoid cuts from sharp metal fins on front and rear coils. • Install the room air conditioner on the shady side of your home. A window that faces north is best because it is shaded most of the day. Y_ • Do not block air flow inside with blinds, curtains, or furniture; or outside with shrubs, enclosures, or other buildings. ELECTRICAL INFORMATION The complete electrical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements. • Close the floor and wall registers and the fireplace damper so cool air does not escape up the chimney and into the duct work. • Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards. • Keep blinds and drapes in other windows closed during the sunniest part of the day. • Clean the air filter as recommended in the MAINTENANCE section of this manual. • Your air conditioner must be plugged into a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. • Proper insulation and weather stripping in your home will help keep warm air out and cool air in. • External house shading with trees, plants or awnings will help reduce the air conditioner's work load. • Do not run air conditioner with packing sheet of the back of the sleeve, and packing corner and blue tape of the air conditioner. This could result in mechanical damage within the air conditioner. • Operate heat producing appliances such as ranges, washers, dryers, and dishwashers during the coolest part of the day. • Do not use an extension cord or an adapter plug. -3- OBSERVE ALL LOCAL CODES AND ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG, ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE. A 208/230-volt 60 Hz, AC only, 15A fused and properly grounded electrical supply is required. A time delay fuse or time delay circuit breaker is recommended. Use a dedicated circuit, serving only this appliance. Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. DO NOT USE AN EXTENSION CORD. RECOMMENDED Failure to follow these instructions can result in death, fire, or electrical shock. GROUNDINGMETHOD For your personal safety, this appliance must be grounded. This appliance has a power supply cord with a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code (ANSI/NFPA 70) latest edition and all local codes and ordinances. If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician. -4- 3 ron "P g Ground prong I'/ "_ _) r I",_ _1 _-3-pr°ng _-, _ \'--J J grounding I I tvee wall plug grounding ]_ Power_ supply cord _ i[ receptacle --- INSTALLATION Remove packingsheet from the backof the sleeve,and packingcomer and bluetape fromthe air conditioner. & INSTALLATION REQUIREMENTS If you use an existing wall sleeve, you should measureits dimensions. Install the new air conditioneraccordingto these installationinstructions to achievethe best performance.All wall sleevesusedto mountthe new air conditionermustbe in goodstructural conditionand have a rear grilleto securelyattach the new air conditioner.(FIG. 1) With the Kenmore sleeve, youcan maintainthe bestperformanceofthe new air conditioner.(FIG. 2) 2 Size options ITEM O . !8"(458 ram) FIG. 1 Oq'Y f HORIZONTAL INSULATION STRIPS 2 AROUND INSULATION STRIPS 2 _) SUPPORT BLOCK 2 BAFFLE 1 (_ (_ TRIM FRAME SHIM 2 2 (_) PLASTICNUTSAND WASHERSCREWS 4 To avoid risk of personal injury, property damage, or product damage due to the weightof this device and sharp edges that may be exposed: • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. • Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time. • Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils. • Make sure air conditioner does not fall during installation. I Expanded aluminum metal g_itlc /. (425m'_l Kenmore Wall Sleeve NAME OF PARTS PLASTIC GRILLE _) (366ram) Air Conditioner HARDWARE FIG. 2 ELECTRICAL SERVICE Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on left side of cabinet). All models are equipped with a 3-prong service plug to provide proper service and safe positive grounding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match your plug, calf a qualified electrician to make the necessary corrections. SAVE CARTON for storage and this OWNER'S MANUAL for future reference. The carton is the best way to store unit during winter or when not in use. REQUIRED TOOLS: • Tight Fitting gloves • Standard screwdriver • 3/8-inch open end wrench or adjustable wrench • Phillips screwdriver • Pliers • 1/4-inch hex socket and ratchet • Sharp knife • Tape measure • Electric drill • 1/4-inch drill bit -5- INSTALLATION NOTE: All wall sleeves used to mount the new Air Conditioner must be in sound structural condition and have a rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the Air Conditioner, We strongly recommend the removal of the old wall sleeve and the installation of a new Kenmore Wall Sleeve. If you decideto keepthe existingwall sleeve, you have to redirectthe louversat the backof the wall sleeveillustration.The use of pliers is recommended. If you DO NOT redirect,you run the riskof poorperformanceor productfailure. This is notcoveredunderthe termsof the Kenmorewarranty. []Remove sleeve. • Pick a location which will allow the conditioned air to blow into the area you want. Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed. ITEM (inches) 263/4x 161/2 I Horizontal Insulation Stripe113/8 x s/8x 273/16 Plastic grille 13/8 X 13/8 X 273/16 Around Insulation Strips 13/8x 3/4x 611/2 1% x 1% x 611/2 13/4x 1% x 451m 14 x 41/2x 1/8 13x lx3/4 Support Block Baffle Shim Trim Frame Washer Screw Nuts(Plastic) Clean the interior of an existing sleeve. (Do not disturb seals.) Q Wall sleeve must be securely fastened in wall before installing the air conditioner. Use the nails or screws through sleeve into wall, if needed. Repaint sleeve if needed. !_ Prepare the wall sleeve for installation of the unit. If you plan to use your existing wall sleeve, and it is not Kenmore, use procedure B or C below. Qty. 1 1 1 1 1 2 1 2 2 4 4 Brand Sears/Kenmore White-Westinghouse Frigidaire Carrier (52F series) General Electric /Hotpoint Whirlpool Carrier (51S series) White-Westinghous_ Frigidaire Carrier (52F series) General Electric /Hotpoint 17-1/8 or 23 18-5/8 16-3/4 or 19-3/4 15 16-3/4 _r_ Install new unit into wall sleeve. UNIT Wall Sleeve Wall Sleeve Dimensions (inches_, Width Height Depth 15-1/4 16, 17-1/2 or 22 26 15-5/8 16-7/8 25-7/8 16-1/2 17-1/8 or 23 Fedders/Emerson 27 16-3/4 Sears/Kenmore Emerson/Fedders 25-7/8 26-3/4 25-3/4 27 15-17/32 15-3/4 16-7/8 16-3/4 16-3/4 or 19-3/4 16-23/32 15 18-5/8 16-3/4 Carrier (51S Series) Friedrich 16-7/8 CAUTION: When installation is completed, replacement unit MUST have a rearward slope as shown. 25-1/2 Whirlpool 16, 17-1/2 or 22 Emerson/Fedders Friedrich Identify the existing wall sleeve before installing the unit from the listed below. Brand Depth(inches) 16-23/32 Fedders/Emerson C HOW TO INSTALL li]l _1 Procedure A ITEMS IN INSTALLATION HARDWARE You may not need all parts in the kit. Discard unused pads old air conditioner from existing wall FRONT"_ 1- -_ ............. 114" i _ -6- ............. i i FIG. 3 PROCEDURE ] A L_ If you are using the new sleeve supplied with your unit, skip to step 3. Otherwise, install the plastic grilla from the kit. Cut the plastic grille to 25-1/2" wide and 15-1/4" high. Place the plastic grille to the inside of the wall sleeve at the rear flange. Install the new unit into the wall sleeve. IL_To assemble trim, snap the tab of each piece into the slot of the other piece as shown below. Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below. I FIG. 4 Trim (2 ea) O Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges. Wall FIG. 7 FIG. 5 I_ Remove the backing from the Horizontal Insulation strip 13/8x 3/8 X 273!16 and attach that to the inside bottom of the sleeve as shown below. Remove the backing from the Around Insulation strip 1% x 3/4x 61 _2 and attach that to the inside front of the sleeve as shown below. • Air conditionerscovered in this manual pose an excessive weighthazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. • When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils. • Make sure air conditioner does not fall during removal. FIG. 6 -7- PROCEDURE _1 B _J Redirsct the louvers at the back of the wall sleeve to 60 ° angle as shown in the FIG 8. The use of pliers is recommended. Remove the backing from the Horizontal Insulation strip 13/8x % x 273/lS and attach that to the inside bottom of the sleeve as shown below. Remove the backing from the Around Insulation strip 13/8x 3/4x 611/2and attach that to the inside front of the sleeve as shown below. 7 5/16" \\\\\\\\\\\\\\\\\\\_ Rear Louve_'s (Top View) FIG. 8 FIG. 11 _'_lf the wall sleeve already has a rear grille, skip to step 4. If the wall sleeve does-not have a rear grille or Iouvered panel, install the plastic gdlle from the kit. Cut the plastic gdlle to 25-1/2" wide and 15-1/4" high. Place the plastic gdlle to the inside of the wall sleeve at the rear flange. _-"_ If the depth of your existing wall sleeve is less than or equal to 18", skip to step 7. Otherwise, cut the baffles and the support blocks according to length "A" in the table below. Depth"D"of the existing Length"A" wall sleeve (inches) (inches) 18
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 40 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Tue Aug 14 16:07:11 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools