INSTALLATION
AND SERVICE MUST BE
PERFORMED
BY A QUALIFIED
INSTALLER.
IMPORTANT:
SAVE FOR LOCAL ELECTRICAL
INSPECTOR'S
USE. READ AND SAVE THESE
INSTRUCTIONS
FOR FUTURE REFERENCE.

__

important

• ALL RANGES
CAN TiP
• INJURYTO
PERSONS
COULD RESULT
• iNSTALL ANTI=TIP
DEVICE PACKED WiTH
RANGE
• SEE iNSTALLATiON
INSTRUCTIONS

if the

information

in this

Read all instructions contained in these installation
instructions before installing range.

•

Remove all packing material from the oven
compartments before connecting the gas and
electrical supply to the range.

•
•

Observe all governing codes and ordinances.
Be sure to leave these instructions with the consumer.

notes to the consumer

•

Keep these instructions with your Use & Care Guide
for future reference.

•

Be sure your range is installed and grounded properly
by a qualified installer or service technician.

Special instructions for appliances installed in the State of
Massachusetts:
This appliance can only be installed in the State of
Massachusetts by a Massachusetts licensed plumber or
gas fitter. When using a flexible gas connector, it must not
exceed 3 feet (36 inches) in length. A "T" handle type
manual gas valve must be installed in the gas supply line to
this appliance.

FOR YOUR SAFETY:
Do not store or use gasoline or other
flammable
vapors and liquids in the
vicinityofthis
oranyotherappliance.
WHAT TO DO iF YOU SMELL GAS:

IMPORTANT

= Do not try to light any appliance.
= Do not touch any electrical
switch;
do not use any phone in your
building.
= immediately
call your gas supplier
from a neighbor's
phone.
Follow
the gas supplier's
instructions.
= if you cannot
reach
your
gas
supplier,
call the fire department.
installation
and service
must be

SAFETY

INSTRUCTIONS

Installation of this range must conform with local codes or,
in the absence of local codes, with the National Fuel Gas
Code ANSI Z223. l--latest edition when installed in the
United States.
When installed in a manufactured (mobile) home,
installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
[formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD (Part 280)] or, when
such standard is not applicable, the Standard for
Manufactured Home Installations, ANSI/NCSBCS A225.1,
or with local codes.

performed by a qualified
installer,
service agency or the gas supplier.
Provide

notes to the installer

•

important

manual is not followed
exactly, a fire or
explosion may result causing property
damage, personal injury or death.

m

for applicable agency
certifications
Refer to your serial plate

This range has been design certified by CSA International.
As with any appliance using gas and generating heat, there
are certain safety precautions you should follow. You will
find them in the Use & Care Guide, read it carefully.

proper fuel type

Before proceeding: Your range is factory preset to
operate on natural gas. If L.P. conversion is needed,
contact your local L.P. Gas provider for assistance.
The L.P. conversion kit may be located on the lower rear
back panel of the range. If no L.P. kit is provided, contact
your product dealer to obtain the correct L.P. conversion kit.
1

p/n 316903000 (1004)

iMPORTANT

SAFETY iNSTRUCTiONS

DO NOT MAKE ANY ATTEMPT TO
OPERATE THE ELECTRIC IGNITION OVEN DURING AN
ELECTRICAL POWER FAILURE. RESET ALL OVEN
CONTROLS TO "OFF" IN THE EVENT OF A POWER
FAILURE,

Be sure your range is installed and grounded
properly by a qualified installer or service
technician.
•

•

This range must be electrically
grounded in
accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA
No .70mlatest edition when installed in the United
States. See Grounding Instructions on page 8.

When an electrical power failure occurs during use, the
surface burners will continue to operate.

Before installing the range in an area covered with
linoleum or any other synthetic floor covering,
make sure the floor covering can withstand heat at
least 90°F above room temperature without
shrinking, warping or discoloring.
Do not install the
range over carpeting unless you place an insulating
pad or sheet of 1/4-inch thick plywood between the
range and carpeting.

•

Make sure the wall coverings around the range
can withstand the heat generated by the range.

•

Do not obstruct the flow of combustion
air at the
oven vent nor around the base or beneath the
lower front panel of the range. Avoid touching the
vent openings or nearby surfaces as they may
become hot while the oven is in operation. This range
requires fresh air for proper burner combustion.

•

The electric ignitor will automatically re-ignite the oven
burner when power resumes if the oven thermostat control
was left in the "ON" position.

During a power outage, the surface burners can be lit with
a match. Hold a lighted match to the burner, then slowly
turn the knob to the LITE position. Use extreme caution
when lighting burners this way.
Never leave children alone or
unattended in the area where an appliance is in use.
Teach children the proper, safe use of all appliances. Never
leave the oven door open when the range is unattended.
Stepping,

leaning or sitting

on the doors

or drawers of this range can result in serious
and can also cause damage to the range.
•

Air curtain or other overhead range hoods, which
operate by blowing a downward air flow on to a range,
shall not be used in conjunction with gas ranges other
than when the hood and range have been designed,
tested and listed by an independent test laboratory for
use in combination with each other.

•

injuries

Do not store items of interest to children in the
cabinets above the range. Children could be
seriously burned climbing on the range to reach items.
To eliminate the need to reach over the surface
burners, cabinet storage space above the burners
should be avoided.

2

•

Adjust surface burner flame size so it does not
extend beyond the edge of the cooking utensil.
Excessive flame is hazardous.

•

Do not use the oven as a storage space. This
creates a potentially hazardous situation.

•

Never use your range for warming or heating the
room. Prolonged use of the range without adequate
ventilation can be dangerous.

•

Do not store or use gasoline or other flammable
vapors and liquids near this or any other
appliance. Explosions or fires could result.

•

Reset all controls to the "OFF" position
a programmable
timing operation.

•

Unlike some gas ranges, the cooktop is not
removable. Do not attempt to remove the cooktop.

after using

Tools you

Tools

will need

(Wear safety glasses when using tools):
For leveling

legs and Anti=Tip Bracket:

•

Adjustable wrench or channel lock pliers (Fig. a)

•

5/16" Nutdriver or flat head screwdriver

•

Electric drill & 1/8" drill bit (3/16" Masonry drill bit if
installing in concrete) (Fig. c)

•

Level (Fig. d)

Fig. f
Fig. b

For gas supply connection:
•

Fig. e

Fig. a

(Fig. b)

Adjustable wrench and pipe wrench (Figs. a & e)
Fig. g

For burner flame adjustment:
•

Phillips head and small flat-blade screwdrivers (Figs. f
&g)

Materials

you

will

•

Pipe joint sealant that resists action of LP/Propane
gas (Fig. h)

•

Gas line manual shut-off valve (Fig. i)

•

A new flexible metal appliance conduit (1/2" NPT x
3/4" or 1/2" I.D.) must be design certified by CSA
International. Because solid pipe restricts moving the
range, we recommend using a new flexible conduit (4
to 5 foot length) for each new installation and
additional reinstallations. (Fig. j)

•

Use new flare union adapters (1/2" NPT x 3/4" or 1/2"
I.D.) (Fig. k)

Materials

supplied

Fig. c

need:

Fig. d

Materials

Fig. h
Fig. k

with appliance:

•

Anti=Tip Template (Fig. I)

•

Anti-Tip bracket; includes 2 mounting screws (Fig, m)

Fig. i

Fig. j

IVlaterials supplied

Fig. I

3

with

appliance

Fig. m

Installation

with cabinets

Check location where the range will
be installed for proper electric and
gas supply, and stability of the floor.
The dimensions shown here must
be used and are minimal unless
otherwise stated. These
18 _

measurements do not allow for any
clearance below the cooking top or
at the rear of the range.

Min. to cabinets on
either

side of range

Contact surface must be solid and
level.
Things to remember:
•

Do not seal the range to side
cabinets.
Do not pinch the power supply
cord between the range and
rear wall.

I

36 _

•

•

If cabinet depth is greater than Std.
25", the oven front frame must
/
extend beyond cabinet front by
1/2" minimum (See Fig. 1).
All openings in the wall or floor
where the range is to be
installed must be sealed.

installation

beside

wall

Recommended
area for 120V
outlet

"15"

on rear

of

wall and area for
thru the wall
connection
of pipe
stub and shut-off
valve.

Recommended

area for thru
/

the floor connection
of gas
pipe stub and shut-off valve.
* Models without

If installing beside a wall, the
minimum distance to combustible
wall on either side of range above
36" height should be according to
the BTU of the largest burner (See
Fig 2).

self-clean

feature

may have an additional
7 inches
clearance from the floor.

Fig. 1

?
48-1/2"
max

29-1/4"
_Fmax
door
closed

36_+1/8"
(Adjustable)

* 9500 BTU or less
10,000 - 16,999 BTU

2" *_
3" |

Fig. 3

Fig. 2
4

Install anti-tip
IMPORTANT

FASTEN

bracket

Floor Mount

b.

Drill pilot holes & fasten bracket - Drill 1/8" pilot hole
where screws are to be located (Fig. 6). If bracket is to
be mounted to the wall, drill
pilot hole at an approximate
20 ° downward angle. If
bracket is to be mounted to
masonry or ceramic floors,
drill 3/16" pilot hole 1-3/4"
deep. The screws provided
may be used in wood or
concrete material. Use 5/16'
nut-driver or flat head
screwdriver to secure the
bracket in place.
Fig. 6

c.

Level & position range - Level range by adjusting the
(4) leveling legs with a wrench.

instructions

Mark the floor or wall where left or right side of the
range will be located. If rear of range is against wall or
no further than 1-1/4" from wall when installed, you
may use the wall or floor mount method. If molding is
installed and does not allow the bracket to fit flush
against wall, remove molding or mount bracket to
floor.

Note: A min. clearance of 1/8" is required between bottom
of range and leveling legs to allow room for bracket.

For wall mount (Fig. 4), locate the bracket by placing
the back edge of the template against rear wall and
the side edge of template on the mark made
referencing the side of the range. Place bracket on top
of template and mark location of the screw holes in
wall. If rear of range is further than 1-1/4" from wall
when installed, attach bracket to the floor (See Fig. 5).

Leveling

(WALL

OR FLOOR

MOUNTING)

--_1

14--=1=1/4"Max.

Leg --

p Bracket

For floor mount, locate the bracket by placing back
edge of the template where the rear of the range will
be located. Mark the location of the screw holes
shown in template.

Locate the bracket using the template - (Bracket
may be positioned on either the left or right side of the
range. Refer to Figs. 4, 5, & 7 to position the bracket if
template is not available).

FASTEN BRACKET

More Than
1=1/4"

Fig, 5

instructions are provided for installation in wood or
cement fastened to either the floor or wall. When
installed to the wall, make sure that screws completely
penetrate dry wall and are secured in wood or metal.
When fastening to the floor or wall, be sure that
screws do not penetrate electrical wiring or plumbing.

a.

_-

Leveling Leg --

if range is ever moved to a different location, the antitip bracket must also be moved and installed with the
range.

installation

(FLOOR
MOUNTING
ONLY)
"_1

SAFETY WARNING!

To reduce the risk of tipping of the range, the range
must be secured to the floor by properly installed antitip bracket and screws packed with the range. Failure
to install the anti=tip bracket will allow the range to tip
over if excessive weight is placed on an open door or
if a child climbs upon it. Serious injury might result
from spilled hot liquids or from the range itself.

Anti=tip bracket

BRACKET

Slide range back into position (Fig. 7). Remove lower
panel or storage drawer to visually check that rear
leveling leg is inserted into and fully secured by the
bracket. For models with a warmer drawer or broiler
compartment, grasp the top rear edge of the range
and carefully attempt to tilt it forward.

_,
Mount

Floor Mount
Fig. 7

Fig. 4

5

Provide an adequate

gas supply.

Connect

range to gas supply.

Please note: Operation at elevations above 2000 ft.,
appliance rating shall be reduced at the rate of 4 percent
for each 1000 ft. above sea level.

Note: To prevent leaks use pipe joint sealant on all male
(outside) pipe threads. Do not allow gas pressure
regulator to turn on pipe when tightening fittings.

This appliance is pre-set to operate on 4" natural gas
manifold pressure. A convertible pressure regulator is
connected to the manifold and MUST be connected in
series with the gas supply line. If the LP/Propane
conversion kit has been used, follow instructions provided
with the kit for converting the pressure regulator to LP/
Propane use.

a.

Install an external manual gas shut=off valve to gas
supply line in an accessible location outside of range.
Be sure you know where and how to shut off the gas
supply to the range (See Fig. 8).

b.

Install 1/2" flare union adapter to gas pressure
regulator using no more than 15ft./Ibs. of torque
(Refer to Fig. 8).

Care must be taken during installation of range not to
obstruct the flow of combustion and ventilation air.
Forproper operation, the maximum inlet pressure to the
regulator should be no more than 14 inches of water
column pressure. The inlet pressure to the regulator must
be at least 1 inch greater than regulator manifold pressure.
Example:
pressure,
regulator
manifold
inches.

If regulator is set for natural gas 4 inch manifold
inlet pressure must be at least 5 inches; if
has been converted for LP/Propane gas 10 inch
pressure, inlet pressure must be at least 11

Pressure

regulator

_

Flexible
/

appliance

conduit

Leak testing of the appliance shall be conducted according
to the instructions in step 4g.
The gas supply line should be 1/2" or 3/4" I.D.
J

_

--i[-

I

Flare
union
adaptor

....................

P
/
_

r shut-off
valve
J,

Seal wail openings.
Seal any openings in the wall behind the range and in the
floor under the range after gas supply line is installed.

Fig. 8 - gas supply connections

OFF

Be sure to stabilize the left side of the gas pressure
regulator before tightening ANY fittings to the pressure
regulator. Do not allow pressure regulator to turn on
pipe when tightening fittings (Refer to Fig. 9).

Fig. 9

6

C.

Tighten the gas supply fitting and/or appliance conduit
to flare union adaptor on the right side of the pressure
regulator (refer to Fig. 10) using NO MORE THAN
15ft./Ibs. of torque. Be sure to stabilize the 1/2" flare
union adapter with an adjustable wrench before
tightening the gas supply fitting and/or appliance
conduit.

Checking

manifold

gas pressure

Do not use flame to check for gas leaks.
Disconnect the range and its individual shut-off valve from
the gas supply piping system during any pressure testing of
that system at test pressures greater than 14" of water
column pressure (approximately 1/2" psig).
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 14" of water column
pressure (approximately 1/2" psig).
If it should be necessary to check the manifold gas
pressure, connect manometer (water gauge) or other
pressure device to the top burner right rear orifice. Using a
rubber hose with inside diameter of approximately 1/4," hold
tubing down tight over orifice. Turn burner valve on.
For an accurate pressure check have at least two (2) other
top burners burning. Be sure the gas supply (inlet) pressure
is at least one inch above specified range manifold
pressure. The gas supply pressure should never be over 14"
water column. When properly adjusted for Natural Gas the
manifold pressure is 4". For LP/Propane Gas the manifold
pressure is 10".

Fig. 10
d.

Install flare union adapter to external manual shut-off
valve (See Fig. 8).

e.

Attach flexible appliance conduit to flare union adaptor
on shut-off valve (See Fig. 8).

f.

Make sure the service shut-off valve on pressure
regulator is set to the ON position (See Fig. 11 ).

Pressure
regulator

Service

shut-off

valve (shown in
ON position)

Fig. 11
g.

Check for gas leaks. Turn the gas supply on to the
range and use a liquid leak detector at all joints and
conduits to check for leaks in the system.

7

Read the following
connection
details
connecting

electrical
before

electricity

Check burner

It is very important to be sure that all surface burner caps
and burner grates are properly installed and in the correct
locations before operating the appliance. Please note that
the burner heads are secured to the cooktop. The cooktop
is not removeable. Do not attempt to remove or lift the
cooktop.

to range.

[1_
Before servicing, disconnect electrical
supply at circuit breaker, fuse or power cord.

Electric

requirements:

To prevent flare-ups and avoid creation of
harmful by-products, do not use the cooktop without all
burner caps properly installed to insure proper ignition and
gas flame size.

A dedicated, properly grounded and polarized branch
circuit protected by a 15 amp. circuit breaker or time delay
fuse. See serial plate for proper voltage.

Extension

cord precautions:

Always keep the burner caps and burner heads in place
whenever the surface burners are in use. Do not allow

Because of potential safety hazards under certain
conditions, we strongly recommend against the use of any
extension cord. However, if you still choose to use an
extension cord, it is absolutely necessary that it be a UL
listed 3-wire grounding type appliance extension cord
and that the current carrying rating of the cord in amperes
be equivalent to or greater than the branch circuit rating.
Such extension cords are obtainable through your local
service organization.

spills, food, cleaning agents or any other material to
enter the gas orifice holder openings.
Check and be sure the size of each burner cap matches
the size of the burner head. Check and be sure that all
round style burner caps are correctly in place on round
burner heads.
Check and be sure that all oval
correctly in place on oval burner
Check and be sure that all dual
are correctly in place on dual or
equipped).

Please read carefully!
For personal
safety, this product must be properly grounded.
Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord (See Fig. 12).

metho_.._

Once in place, you may check the fit by gently sliding the
burner cap from side to side (Fig. 16) to be sure it is
centered and firmly seated. When the burner cap lip makes
contact inside the center of the burner head you will be
able to hear the burner cap click. Please note that the
burner cap should NOT move off the center of the burner
head when sliding from side to side.

Do not, under any
remove or bypass the[
circumstances, cut, |

Grounding

style burner caps are
heads (if equipped).
or twin style burner caps
twin burner heads (if

On round style burners, the burner cap lip (See Fig. 13)
should fit snug into the center of burner head and be level.
Refer to Figs. 14 & 15 for correct and incorrect burner cap
placement.

Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and obligation
of the customer to have it replaced with a properly
grounded three-prong wall receptacle.

Preferred

cap placement.

gr_

Burner cap
receptacle

supply
cord with
3-prong
grounding
plug

"_Burnelr

Fig. 12
Grounding

Fig. 13

cap lip

Correct

burner

cap placement

Fig. 14

instructions:

The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong grounding wall receptacle to minimize the
possibility of electric shock hazard from this appliance. The
customer should have the wall receptacle and circuit
checked by a qualified electrician to make sure the
receptacle is properly grounded and polarized.
Fig. 16

Incorrect

burner

cap placement

Fig. 15
8

Check ignition of surface
burners.
Operation of electric igniters should be checked after range
and supply line connectors have been carefully checked for
leaks and range has been connected to electric power.
a.

•% ,,,

To check for proper ignition, push in and turn a
surface burner knob counterclockwise
to the LITE

other

position. You will hear the igniter sparking.
b.

Visually check that burner has a flame. Once the
burner ignites, the control knob should be turned out
of the LITE position.

d.

Try each surface control knob separately until all
surface burners have been checked. Each burner

Push in and turn control to LITE until burner ignites.

b.

Push in and quickly turn knob to lowest position.

c.
d.

If burner goes out, reset control to OFF.
Remove the surface burner control knob.

Check ignition of oven burners.
The operation of oven igniters should be checked after
range and supply line connectors have been carefully
checked for leaks and range has been connected to
electric power. Be sure all packing materials and
literature are removed from oven.
The oven burner is equipped with an electric control
system as well as an electric oven burner igniter. If your
model is equipped with an upper oven burner, it will also
have an electric burner igniter. These control systems
require no adjustment. When the oven is set to operate,
current will flow to the igniter. It will "glow" similar to a light
bulb. When the igniter has reached a temperature sufficient
to ignite gas, the electrically controlled oven valve will open
and flame will appear at the oven burner. There is a time
lapse from 30 to 60 seconds after the thermostat is turned
ON before the flame appears at the oven burner. When the
oven reaches the set temperature, the glowing igniter will
cycle off. The burner flame will turn off in 20 to 30 seconds
after the igniter turns off. To maintain any set oven
temperature, this cycle will continue as long as the oven
control is set to operate.

For all burner styles (except Dual or Twin burner):
e. Insert a thin-bladed screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame size
can be increased or decreased with the turn of the
screw. Turn counterclockwise to increase flame size.
Turn clockwise to decrease flame size. (See Figs. 17
& 19).
Adjust flame until you can quickly turn knob from LITE
to lowest position without extinguishing the flame.
Flame should be as small as possible without
extinguishing.
For Dual or Twin burner style adjustment
e.

5/8"

Fig. 19

be adjusted:

a.

Fig. 18

Cooktop

Adjust the LOW setting of surface
burner valves (linear flow).
should

J
for Dual or Twin burner only

Burner flame size _

location is equipped with a separate electrode.

Test to verify if LOW setting

burners

Fig. 17

The surface burner should ignite when gas is available
to the burner. Purge air from supply lines by leaving
knob in the LITE position until burner ignites. Each
burner should light within four (4) seconds in normal
operation after air has been purged from supply lines.

c.

surface

To check oven burner ignition:
a. Set oven to Bake at 300°F. See User's Manual for

only:

The inner portion (Simmer) of the twin burner flame
size can be increased or decreased with the turn of
screw A. Use screw B to adjust the flame size of the
outer portion of the Twin Burner (See Fig. 18). Turn
the screw counterclockwise to increase flame size.
Turn clockwise to decrease flame size. Adjust flame
size until you can quickly turn the knob from LITE to
lowest position without extinguishing the flame.

operating instructions.

Note: Air mixture adjustments are not required on surface
bumers.
9

b.

Within 60 seconds the oven burner should ignite.
Check for proper flame, and allow the burner to cycle
once. Reset control to OFF.

c.

If your model is equipped with a waist-high broiler, set
oven to Broil. See User's Manual for operating
instructions.

d.

Within 60 seconds the broil burner should ignite.
Check for proper flame. Reset control to OFF.

Adjust air shutter - lower oven.

Make sure range is level.

To determine if the oven burner flame is proper, remove the
oven bottom panel and lower burner baffle (Refer to Fig.
20) and set the oven to Bake at 300°F. The approximate
flame length of the lower oven burner should be 1 inch with
a distinct inner blue flame.

Level the range by placing a level horizontally on an oven
rack. Check diagonally from front to back, then level the
range by either adjusting the leveling legs or by placing
shims under the corners of the range as needed.
Note: After installation is complete, make sure all controls
are left in the off position.

To remove the lower oven bottom, remove oven bottom
hold down screws at rear of oven bottom panel. Pull up at
rear, disengage front of oven bottom from oven front frame,
and pull the oven bottom out of the oven. Remove lower
burner baffle to observe oven burner flame.

Care, cleaning

Refer to the User's manual for detailed cleaning
instructions. If removing the range is necessary for
cleaning or maintenance, shut off gas supply. Disconnect
the gas and electrical supply. If the gas or electrical supply
is inaccessible, lift the range slightly at the front and pull out
away from the wall. Pull out only as far as necessary to
disconnect the gas and electrical supply. Finish removing
the range for servicing and cleaning. Reinstall in reverse
order making sure to level the range and check gas
connections for leaks. Be sure to read and follow step 1 for
properAnti-tip installation.

If the flame is yellow in color, increase the lower oven air
shutter opening size. If the flame is a distinct blue, reduce
the air shutter opening size.

1
-'J

Upper oven burner
(some models)

Before

-°
;_=_=

-

Lower

oven

Lower
bottom

oven
panel

you call for service

Read the "Before You Call" and operating instruction
sections in your Use & Care Guide. It may save you time
and expense. The list includes common occurrences that
are not the result of defective workmanship or materials in
this appliance.

Upper oven burrler air
(some models)

burner baffle

and maintenance

/

Refer to the warranty in your Use & Care Guide for our tollfree service number and address. Please call or write if you
have inquiries about your range product and/or need to
order parts.

burner
a!r (rem°vab Ie)
shutter

Fig. 20 - oven burner locations

Model and serial number
To adjust lower oven air shutter
loosen lock screw (See Fig. 21 ),
reposition air shutter, and
tighten lock screw. When
finished adjusting replace
burner baffle and oven bottom

The identification plate is located on the right-hand surface
of the oven front frame. To access this plate, open the
storage drawer (some models), warmer drawer (some
models) or broiler drawer (some models) (See Fig 22).
When ordering parts for or making inquires about your
range, always be sure to include the model and serial
numbers and a lot number or letter from the identification

Orifice hood

panel.

location

Oven burner

plate on your range. Your identification plate also tells you
the rating of the burners, the type of fuel and the pressure
the range was adjusted for when it left the factory.

Fig. 21 - typical oven
burner air shutter

Adjust air shutter - upper oven.
(some models).
The approximate flame length of the upper (broil) burner
should be 1 inch having a distinct inner, blue flame. To
determine if the upper broil burner flame is proper, set the
oven to Broil. If the flame is yellow, increase upper oven
air shutter opening size. If the flame is a distinct blue,
reduce the air shutter opening size.
To adjust the upper air shutter loosen lock screw (See Fig.
21), reposition air shutter, and tighten lock screw.

Fig. 22
10



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 10
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Fri May 24 07:03:45 2013
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu