Kenmore 5200 Btu Room Air Conditioner Installation Guide
25370051015 25370051015 KENMORE ROOM AIR CONDITIONER - Manuals and Guides 1206660L View the owners manual for your KENMORE ROOM AIR CONDITIONER #25370051015. Home:Heating & Cooling Parts:Kenmore Parts:Kenmore ROOM AIR CONDITIONER Manual
2015-03-28
: Kenmore Kenmore-Kenmore-5200-Btu-Room-Air-Conditioner-Installation-Guide-670651 kenmore-kenmore-5200-btu-room-air-conditioner-installation-guide-670651 kenmore pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
READ BEFORE INSTALLING UNIT MSII Window Mounting (5~8K BTU) To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed: Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time. Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins on front and rear coils. Make sure air conditioner does not fall during installation. f Mounting • SAVE CARTON and these INSTALLATION INSTRUCTIONS for future reference. The carton is the best way to store unit during winter, or when not in use. Hardware Qty. 1/2" screws 7 lock frame 2 (For Wooden windows) lock frame • DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED HERE. (For Vinyl-Clad windows) • FOR SAFETY REASONS, THE TOP RAIL MUST BE SECURELY FASTENED WITH ALL FOUR (4) SCREWS. sashlock weather seals (6"X3/4"X1/12") window sash seal foam Some assembly is required. Please read these instructions carefully. Top Rail Hardware TOOLS NEEDED Qty. 3/8" Screw 4 • Top Rail 1 • Drill (If pilot holes are needed) Philips Screwdriver Before installing, the top rail must be assembled on the unit. A. Remove the air conditioner from the carton and place on a flat surface. B. Remove top rail from the rear of the packaging material as shown in Fig. A C. Align the hole in the top rail with those on the top of the unit as shown in Fig. B D. Secure the top rail to the unit with the 3/8" Screws as shown in Fig. C Fig. A Packac _ Fig. B [ _. )p Rail 2020211A1447 LEFT + RIGHT FILLER PANEL ASSEMBLY NOTE: Top Rail and Side Panels at each side are offset to provide the proper pitch to the rear of (5/16"). This is necessary for proper condensed water utilization and drainage, if you are not using the Side Panels for any reason, this pitch to the rear must be maintained! Place unit on floor, a bench or a table. There is a Left and Right side Filler Panels - be sure to use the proper panel for each side. When installed, the flange for securing the panel in place to the window sill will be facing into the room. A. Hold the side Panel in one hand and gently pull back the center to free the open end. See FIG. 1. B. Slide the free end "r' section of the panel directly into the cabinet as shown in FIG. 2. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet. C. Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet. See FIG. 3. D. Slide the panel all the way in and repeat on the other side. FIG. 1 FIG. 2 'T' section FIG. 3 Top Rail : ...... ........... :%:7 r'_ _J _/ JJ it ] J_ Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches (584 mm to 914 mm) (FIG. 4A _ FIG. 4B). Lower sash must open sufficiently to allow a clear vertical opening of 14 inches (356 mm ). Side louvers and the rear of the air conditioner must have clear air space to allow enough airflow through the condenser, for heat removal. The rear of the unit must be outdoors, not inside a building or garage. OFI Fig. 4A EXTERIOR WALL _1 EXTERIOR 23"to36"IIII I mn to llL WALL Wooden Windows Vinyl-Clad Windows Storm Window: FIG. 5 If the air conditoner is blocked by Storm Window, add wood as shown in FIG. 5, or remove storm window before air conditioner is installed. If Storm Window Frame must remain, be sure the drain holes or slots are not caulked or painted shut. Accumulated Rain Water or Condensation must be allowed to drain out. SASH Storm window frame or other obstruction. 1-1/2" min (38 mm) Board thickness as required, for proper pitch to rear, along entire sill. "_ Fasten with nails or screws. Keepa firmgripontheairconditioner, carefullyplacetheunitintothewindowopeningsothebottomoftheair conditioner frameis againstthewindowsill(FIG.6A& FIG.6B).Carefullyclosethewindowbehindthetop rail oftheunit. FIG. 6B I OUTSIDE OUTSIDE INSIDE 1 Wooden Windows Vinyl-Clad Windows Extend the side panels out against the window frame (FIG. 7A for wooden windows), windows). FIG. 7A (FIG. 7B for Vinyl-Clad FIG. 7B window frame Place the frame lock between the frame extensions and the window sill as shown (FIG. 8A for wooden windows), (FIG. 8B for Vinyl-Clad windows). FIG. 8A FIG. 8B wooden windows: Vinyl-Clad windows: Drive locking screws: A: For wooden windows: Drive 1/2" (12.7 mm) locking screws through the frame lock and into the sill (FIG. 9A). NOTE:To prevent window sill from splitting, drill 1/8" (3mm) pilot holes before driving screws. Drive 1/2" (12.7 mm)locking screws through frame holes into window sash (FIG. 9B). B: For Vinyl-Clad windows: Drive 1/2" (12.7 mm) locking screws through the frame lock and into the window sash (FIG. 9B). NOTE: Before driving the screws, use a drill to drill 5 holes through the holes in the frame lock and frame extensions into the windows sash as shown ( FIG. 9B). FIG. 9B FIG. 9A /_ To secure lower sash in place, attach right angle sash lock with 1/2" (12.7 mm) screw as shown (FIG. 10). NOTE: It is difficult to lock the windows with the sash lock for Vinyl-Clad windows, so you can use lock by window itself. Cut foam window seal and insert it into the space between the upper and lower sashes (FIG. 11). FIG. 10 FIG. 11 After the completion of the installation, please check the machine's lean as shown (FIG. 12A & FIG. 12B). It's necessary for proper condensed water utilization and drainage. FIG. 12A FIG. 12B \ I o OUTSIDE ® e 5 OUTSIDE INSIDE -H2 about 1/4"~1/2 '' Rail Rail 1/4"~1/2" H 1_ _ ]___Bottom I Wooden Window Vinyl-Clad Window Trim the weather seal (6"X3/4"X1/12") with a proper length, peel off the protective backing and plug any gaps if needed as shown FIG.13. Removing the air conditioner From Window Turn the air conditioner off, and disconnect power cord. Remove sash seal from between windows, and unscrew sash lock. Remove screws installed through frame and framelock, o..... / Close (slide) side panels into frame. ! i Keeping a firm grip on air conditioner, raise sash and \ carefully remove. Be careful not to spill any condensate water while lifting unit from window. Store parts WITH air conditioner. FIG. 13
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 4 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Wed Jul 04 04:14:52 2012 Author : Title : Subject :EXIF Metadata provided by EXIF.tools