Kenmore Elite 8 0 Cu Ft Steam Electric Dryer Measurement Cheat Sheet

2015-03-28

: Kenmore Kenmore-Kenmore-Elite-8-0-Cu-Ft-Steam-Electric-Dryer-Measurement-Cheat-Sheet-671166 kenmore-kenmore-elite-8-0-cu-ft-steam-electric-dryer-measurement-cheat-sheet-671166 kenmore pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

26-8110X.PDF
26-81102/1/0, 26-91102/1/0
Page 1 of 2
Effective 04/25/11
03311
Due to Sears policy of continuous improve ment on its products, Sears
reserves the right to change materials and specifications without notice.
Before installing, consult installation instructions packed with product
for current dimensional and installation data.
Shown with washer 26-41102 and optional drawer pedestals 26-58892
SELECTION ELITE
Electric Dryers:
White 26-81102
Lemongrass 26-81101
Blackberry 26-81100
Gas Dryers:
White 26-91102
Lemongrass 26-91101
Blackberry 26-91100
DRYER FEATURES STEAM
Capacity (cu. ft.) 8.0
Steam Care
Soft Heat Technology 8 Cycles
Temperature Selections 5
Sensor Drying System 4 Moisture Sensor Bars
CYCLES AND OPTIONS 15 / 12
Specialty Cycles and Options
Heavy Duty, Allergen, Sanitize
(NSF® Certified), Khaki / Jeans,
Towels, Bulky Bedding, Delicates,
Mixed Load, Normal / Casual,
Touch Up, Install, Automatic Dry
Steam Cycles and Options Steam Refresh
Timed Drying Up to 60 Minutes
Express Dry
Extra Dry
Air Dry
Wrinkle Guard®Up to 60 Minutes
More Time / Less Time
Add Steam
CONVENIENCE FEATURES
Drying Rack Included
Check Vent
Time Remaining Display
Status Indicator(s)
Damp Dry Signal
Drum Light LED
Control Lock
Venting Electric / Gas
4-Way Kitless Rear Venting /
4-Way Kitless Rear Venting
Rear Venting Duct Elbow #49609
GENERAL FEATURES
Controls Electric LED SmoothTouch
Stainless Steel Drum
Door Configuration Reversible
See-Through Window
Optional Pedestals 26-58890 / 1 / 2
Stackable Installation Kit Included
Electric Volts / Hz / Amps 240 / 60 / 30
Electric Dryer Circuit
Requirements (60Hz)
30 Amp Circuit Breaker
Time Delay Fuse
Gas Dryer Rating: Volts / Hz / Amps 120 / 60 / 15
Gas Burner BTU / Hour 20,000
LP Gas Conversion Kit 26-38239
Gas Pipe Size (O.D. Inches) 3/8
DIMENSIONS / WEIGHT
Product Dimensions (Inches)
(H x W x D x D with Door Open) 38 x 27 x 31 1/2 x 53 1/2
Item Weight (Approx. Lbs.) 130
Shipping Weight (Approx. Lbs.) 130
WARRANTY
1-Year Limited Warranty –
Mechanical and Electrical Parts Parts & Labor
If used for other than private family purposes, warranty applies for only 90 days.
Kenmore Elite Front-Loading Steam Dryer
Electric Dryer Gas Dryer
White 26-81102 White 26-91102
Lemongrass 26-81101 Lemongrass 26-91101
Blackberry 26-81100 Blackberry 26-91100
• 8.0 cu. ft. capacity
• Steam Care with direct water hook up
• Electronic LED SmoothTouch controls
• 15 drying cycles and 12 drying options
• Sensor drying with 4 moisture sensor bars in the drum
• Steam Refresh cycle
• NSF® Certified sanitize cycle
• Drying rack
• Stainless steel drum
• LED drum light
• Reversible side-swing door with see-through window
• 4-way electrical / gas kitless rear venting
26-49387, 26-49787 26-49388, 26-49788
*Complies with 1/1/96 NEC code revision for new construction and remodeling
All Electric Dryers Require Cord
Order Wire Length
26-49387 3 4 ft.
26-49787 3 6 ft.
26-49388* 4 4 ft.
26-49788* 4 6 ft.
POWER CORDS FOR ELECTRIC DRYERS ONLY
Gas Dryer Connector – Stainless Steel
26-49590 1/2" - 3/8" Flex, 5 ft.
26-49585* 3/8" - 3/8" Flex, 5 ft.
*Los Angeles only
26-8110X.PDF
26-81102/1/0, 26-91102/1/0
Page 2 of 2
Effective 04/25/11
03311
Due to Sears policy of continuous improve ment on its products, Sears
reserves the right to change materials and specifications without notice.
Before installing, consult installation instructions packed with product
for current dimensional and installation data.
4-WAY VENTING KIT
Call Sears Parts
1–800-225-2864
38020
26-98379 — Vent Hood
Aluminum body and plastic
molded hood with a 4" opening.
4" Clearance Behind the Dryer is Preferred for Best Airflow.
2" Clearance is Achieved With Periscopes.
Clamps are recommended for wall
and dryer connections. Steel clamps
designed to resist stretching, with
phillips/hex head screw are included
one each on elbows and periscopes.
DRYER VENTING RECOMMENDATIONS 4" CLEARANCE BEHIND DRYER
26-49900 — Over-The-Top Kit
Universal solution, 8 foot length. Kit includes two 4 ft.
pipe sections with attached elbows, two close elbows,
clamps and wall plate.
26-49608 — Flexible Pipe
4" x 6' with snap-lock fittings, 90˚ turn takes 1 foot
length and 6 inch clearance.
26-49609 — Close Elbow
Turns 90˚ within 4", rotating collars and snap-lock
fittings.
VENT HOOD TYPE
Number
of 90°
Turns 4"
4"
2 1/2"
4" 4"
2 1/2"
4" 4"
2
1
/
2
"
0125 ft 125 ft 110 ft
Max. Length
of 4" Dia.
Rigid Heavy
Metal Vent
1115 ft 115 ft 100 ft
2105 ft 105 ft 90 ft
395 ft 95 ft 80 ft
485 ft 85 ft 70 ft
IMPORTANT NOTE:
Do not use non-metal flexible duct. Also, when
installing the venting system, do not exceed the
specified length for the vent duct. Venting systems
which are longer than specified will accumulate
lint, increase drying time and energy use and
shorten the life of the dryer.
2" CLEARANCE BEHIND DRYER
26-49908 — Periscope 0-18"
For outlets that overlap or are very close
26-49904 — Periscope 18-29"
Reaches side of most dryers
26-49905 — Periscope 29-50"
Reaches top of most dryers
WASHER AND DRYER DIMENSIONS / OPTIONAL PEDESTALS / STACKING KITS
Washer
Washer Dimensions W x H x D
(Depth with Door Open) Dryer
Dryer Dimensions W x H x D
(Depth with Door Open) Color Stacking Kit Pedestal Pedestal Dimensions W x H x D
26-41102 27" x 38" x 31 12" (53 12") 26-8/91102 27" x 38" x 31 12" (53 12") White Included 26-58892 27" x 15" x 27"
26-41101 27" x 38" x 31 12" (53 12") 26-8/91101 27" x 38" x 31 12" (53 12") Lemongrass Included 26-58891 27" x 15" x 27"
26-41100 27" x 38" x 31 12" (53 12") 26-8/91100 27" x 38" x 31 12" (53 12") Blackberry Included 26-58890 27" x 15" x 27"
26-38239
LP Kit Dryers
INSTALLATION OPTIONS
*Connection of water inlet hose on steam dryer adds 3/4 in. to installation depth.
1Power supply cord length on gas dryer approximately 60 inches.
2 Hot and cold inlet hose length on washer approximately 48.5 inches.
3Drain hose length on washer approximately 59 inches.
4Power supply cord length on washer approximately 60 inches.
53 1/2"*
to clear
open door 27"
electrical
supply on
rear of unit4
centerline
height for
rear vent
19"
3 7/10"
1 1/2"
3 3/4"
38"
17"
gas
supply
pipe on
rear of
gas unit
13 1/2"
to center of rear vent
freestand
dryer on floor
floor line
floor line
dryer mounted on
optional pedestal
53 1/2"*
to clear
open door
75 3/4"
27"
centerline
height for
rear vent
41"
39"
water
supply
connection
on rear
of unit1
drain hose
on rear
of unit3
electrical
supply
on rear
of unit4
power
cord on
rear of
unit2
gas supply
pipe on rear
of gas unit
floor line
53 1/4"
31 1/2"*
to front of closed door
31 1/2"*
to front of closed door
*Connection of water inlet hose on steam dryer adds 3/4 in. to installation depth.
1Power supply cord length on gas dryer approximately 60 inches.
2 Hot and cold inlet hose length on washer approximately 48.5 inches.
3Drain hose length on washer approximately 59 inches.
4Power supply cord length on washer approximately 60 inches.
53 1/2"*
to clear
open door 27"
electrical
supply on
rear of unit4
centerline
height for
rear vent
19"
3 7/10"
1 1/2"
3 3/4"
38"
17"
gas
supply
pipe on
rear of
gas unit
13 1/2"
to center of rear vent
freestand
dryer on floor
floor line
floor line
dryer mounted on
optional pedestal
53 1/2"*
to clear
open door
75 3/4"
27"
centerline
height for
rear vent
41"
39"
water
supply
connection
on rear
of unit1
drain hose
on rear
of unit3
electrical
supply
on rear
of unit4
power
cord on
rear of
unit2
gas supply
pipe on rear
of gas unit
floor line
53 1/4"
31 1/2"*
to front of closed door
31 1/2"*
to front of closed door
*Connection of water inlet hose on steam dryer adds 3/4 in. to installation depth.
1Power supply cord length on gas dryer approximately 60 inches.
2 Hot and cold inlet hose length on washer approximately 48.5 inches.
3Drain hose length on washer approximately 59 inches.
4Power supply cord length on washer approximately 60 inches.
53 1/2"*
to clear
open door 27"
electrical
supply on
rear of unit4
centerline
height for
rear vent
19"
3 7/10"
1 1/2"
3 3/4"
38"
17"
gas
supply
pipe on
rear of
gas unit
13 1/2"
to center of rear vent
freestand
dryer on floor
floor line
floor line
dryer mounted on
optional pedestal
53 1/2"*
to clear
open door
75 3/4"
27"
centerline
height for
rear vent
41"
39"
water
supply
connection
on rear
of unit1
drain hose
on rear
of unit3
electrical
supply
on rear
of unit4
power
cord on
rear of
unit2
gas supply
pipe on rear
of gas unit
floor line
53 1/4"
31 1/2"*
to front of closed door
31 1/2"*
to front of closed door
1" 0"
0"
0"
60 sq. in.
60 sq. in.
3"
3"
Closet Door
Installation in a recess or closet
1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same closet as the gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. Closet door ventilation required: a minimum of 120 square inches of opening, equally
divided at the top and bottom of the door, is required. Openings should be located 3 inches
from bottom and top of door. Openings are required to be unobstructed when a door is installed.
A louvered door with equivalent air openings for the full length of the door is acceptable.
1" 0"
0"
0"
60 sq. in.
60 sq. in.
3"
3"
Closet Door
Installation in a recess or closet
1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same closet as the gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. Closet door ventilation required: a minimum of 120 square inches of opening, equally
divided at the top and bottom of the door, is required. Openings should be located 3 inches
from bottom and top of door. Openings are required to be unobstructed when a door is installed.
A louvered door with equivalent air openings for the full length of the door is acceptable.
1" 0"
0"
0"
60 sq. in.
60 sq. in.
3"
3"
Closet Door
Installation in a recess or closet
1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same closet as the gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. Closet door ventilation required: a minimum of 120 square inches of opening, equally
divided at the top and bottom of the door, is required. Openings should be located 3 inches
from bottom and top of door. Openings are required to be unobstructed when a door is installed.
A louvered door with equivalent air openings for the full length of the door is acceptable.
1" 0"
0"
0"
60 sq. in.
60 sq. in.
3"
3"
Closet Door
Installation in a recess or closet
1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same closet as the gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. Closet door ventilation required: a minimum of 120 square inches of opening, equally
divided at the top and bottom of the door, is required. Openings should be located 3 inches
from bottom and top of door. Openings are required to be unobstructed when a door is installed.
A louvered door with equivalent air openings for the full length of the door is acceptable.

Navigation menu