Keri Systems MS 3000 QSG Micro Star Reader Product Guide Quick Start
User Manual: Keri Systems MS-3000 MicroStar Reader Product Guide Product Guide
Open the PDF directly: View PDF
.
Page Count: 8
| Download | |
| Open PDF In Browser | View PDF |
MS-3000 MicroStar Reader The MS-3000 MicroStar Reader is intended for installation on a window mullion or a door frame, on or off metal, in proximity applications where an unobtrusive reader is required. The reader provides an audible beeper and a multi colored LED to annunciate the reader's status when used with a PXL-250, PXL-100, or IntelliProx. • • • Amber - to indicate normal operation awaiting an access event Green - to indicate a valid card has been presented or the door has been unlocked for access Red - to indicate an invalid card has been presented or the door is in an alarm condition The MS-3000 MicroStar Reader is housed in a black, weatherproof, shock resistant package. The reader provides optimum performance when mounted on aluminum; read range is slightly reduced if the reader is not mounted on aluminum. 1.0 Specifications 1.1 Dimensions • • Quick Start Guide The MS-3000 MicroStar Reader 3.25 inches High x 1.41 inches Wide x 0.375 inches Deep 8.26 cm High x 3.95 cm Wide x 0.96 cm Deep MS-3000 Figure 1: MS–3000 Dimensions 2305 Bering Drive San Jose, CA 95131 USA (800) 260-5265 (408) 435-8400 FAX (408) 577-1792 Web: www.kerisys.com E-mail: sales@kerisys.com 01815-001 Rev. H Page 1 of 8 Quick Start Guide MS-3000 MicroStar Reader 1.2 • 5v to 14v DC @ 50 ma 1.3 • Operating Voltage Cable Specifications up to 500 feet using six conductor, shielded, stranded AWG 24 wire (such as Belden 9536) 2.0 Mounting Instructions Three holes need to be drilled to mount the MicroStar Reader (see Figure 1). One large hole (0.875" - 7/8") accommodates the beeper and the reader cable. Two small holes are for mounting the reader on the mullion or door frame (hole size is dependent upon the size of the mounting screw). NOTE: Do not mount the reader near sources of Electromagnetic Interference (EMI) such as a computer monitor. EMI degrades a reader's read range. 3.0 Connections MS-3000 The MicroStar Reader does not require configuration; there are no switches or jumpers to set. The MicroStar Reader is normally connected to a PXL-250, PXL-100, or IntelliProx, but can be connected to an alternative host controller/alarm panel through an IntelliProx used in its Wiegand input device mode. All connections needed to support the reader are made through the reader's cable. Please consult the tables on pages 2 and 3 for specific connection instructions. 2305 Bering Drive San Jose, CA 95131 USA (800) 260-5265 (408) 435-8400 FAX (408) 577-1792 Web: www.kerisys.com E-mail: sales@kerisys.com 01815-001 Rev. H Page 2 of 8 MS-3000 MicroStar Reader PXL-250 Connections The "A" reader connects to TB5, pins 1 through 6 (TB5 has a seventh pin, but no connection is made to that pin). The "B" reader connects to TB6, pins 1 through 6 (TB6 has a seventh pin, but no connection is made to that pin). Connecting to the PXL-250 – TB5 or TB6 Pin # Function Wire Color 1 2 3 4 4 5 6 7 Reader Antenna Beeper Reader Power Reader Ground Shield Green LED Red LED no connection Blue Green Red Black Silver Brown White – Quick Start Guide 3.1 MS-3000 Figure 2: PXL-250 Connections 2305 Bering Drive San Jose, CA 95131 USA (800) 260-5265 (408) 435-8400 FAX (408) 577-1792 Web: www.kerisys.com E-mail: sales@kerisys.com 01815-001 Rev. H Page 3 of 8 3.2 Design 5 PXL-100 Connections The "A" reader connects to TB2, pins 14 through 19. The "B" reader to TB3, pins 20 through 25. Connecting the PXL-100 – TB2 Connecting to the PXL-100 – TB3 Pin # Function Wire Color Pin # Function Wire Color 14 15 16 17 17 18 19 Green LED Beeper Reader Power Reader Ground Shield Reader Antenna Red LED Brown Green Red Black Silver Blue White 20 21 22 23 23 24 25 Green LED Beeper Reader Power Reader Ground Shield Reader Antenna Red LED Brown Green Red Black Silver Blue White MS-3000 Quick Start Guide MS-3000 MicroStar Reader Figure 3: Design 5 PXL-100 Connections NOTE: Please contact customer support at Keri Systems for information regarding connecting a Reader to a Design 4 PXL-100. A Design 4 PXL-100 can be identified by the location of its power connection made at the middle of the left edge of the printed circuit board. 2305 Bering Drive San Jose, CA 95131 USA (800) 260-5265 (408) 435-8400 FAX (408) 577-1792 Web: www.kerisys.com E-mail: sales@kerisys.com 01815-001 Rev. H Page 4 of 8 MS-3000 MicroStar Reader IntelliProx Connections The reader connects to TB1, pins 1 through 6. Connecting to the IntelliProx – TB1 Pin # Function Wire Color 1 2 3 4 5 6 6 Reader Antenna Beeper Green LED Red LED Reader Power Reader Ground Shield Blue Green Brown White Red Black Silver Quick Start Guide 3.3 MS-3000 Figure 4: IntelliProx Connections 2305 Bering Drive San Jose, CA 95131 USA (800) 260-5265 (408) 435-8400 FAX (408) 577-1792 Web: www.kerisys.com E-mail: sales@kerisys.com 01815-001 Rev. H Page 5 of 8 Quick Start Guide MS-3000 MicroStar Reader 4.0 Installation Verification The following information applies to an installation with a Keri Systems controller or IntelliProx unit. When used with an alternative host controller/alarm panel through an IntelliProx used in its Wiegand input device mode, the actions of the reader's LED and beeper are controlled by the alternative host controller/alarm panel and might not match those of a Keri Systems controller. The reader's power is provided by the controller, so the reader is powered on when the controller is powered on. The reader's normal state is to display a constantly on Amber LED as it waits for a card or tag to be presented. To verify the reader is functioning properly, pass a Keri Proximity Card or a Keri Key Tag within a few inches of the reader. The reader will beep and either the Green or Red LED will flash (depending upon whether or not the card/tag has been enrolled at the controller) and then return to steady Amber. To verify the reader's read range, hold a Keri Proximity Card or a Keri Key Tag parallel to the reader, about 1 foot away and slowly draw the Card/Tag in toward the reader. Note the distance when the reader recognizes the card. The MicroStar reader's range will be up to 4 inches for a card and 2 inches for a tag depending upon the installation conditions, the material on which the reader is mounted, and whether it is a card or a tag being read. Due to the physical size difference between cards and tags, tags provide approximately 50% less read range than cards. MS-3000 Refer to the Troubleshooting the Reader Installation section beginning on page 7 if the reader is not functioning properly. 2305 Bering Drive San Jose, CA 95131 USA (800) 260-5265 (408) 435-8400 FAX (408) 577-1792 Web: www.kerisys.com E-mail: sales@kerisys.com 01815-001 Rev. H Page 6 of 8 MS-3000 MicroStar Reader Troubleshooting the Reader Installation Problem The reader does not recognize a card/tag (no beep, no LED flash). Probable Cause 1. One or more of the reader's wiring connections are incorrect. Corrective Action • 2. The reader is not • receiving proper power from the controller. 3. The reader is mounted • too close to a device that radiates electromagnetic interference. 4. A jumper is not set correctly on the controller. • • Devices such as computer monitors radiate electromagnetic interference that affects read range. When possible, relocate either the reader or the device to provide a greater distance between the two. For a PXL-250: Verify there is a jumper across pins 1 and 2 of JP4 (refer to the Technical Reference manual for more information - Keri p/n 01836-001). For a PXL-100: If the controllers are using TAPTM software, verify JP1 on the controller and the jumper on the Receiver card1 are installed across both jumper pins. If the controllers are using DoorsTM software, verify JP1 on the controller and the Receiver card1 are not installed across both pins (typically the jumper will be installed onto one of the pins to keep it available). For an IntelliProx: Verify there is not a jumper across pins 1 and 2 of JP1 (typically the jumper can be installed onto one of the pins to keep it available). MS-3000 • Power down the controller and verify the wiring connections are correct for the reader/ controller combination per the instructions provided in the Connections section on pages 2 and 3. Verify the voltage supplied to the reader is between 5 and 14 VDC. Quick Start Guide 5.0 – continued on next page – 1. The receiver board's jumper is on the underside of the board. Gently pull the receiver board away from the controller, verify the jumper setting is correct per your application, carefully align the connectors on the receiver board with the pins on the controller, and gently push the receiver board back into place. 2305 Bering Drive San Jose, CA 95131 USA (800) 260-5265 (408) 435-8400 FAX (408) 577-1792 Web: www.kerisys.com E-mail: sales@kerisys.com 01815-001 Rev. H Page 7 of 8 MS-3000 Quick Start Guide MS-3000 MicroStar Reader Problem Probable Cause 5. You are using an incorrect type of card. 6. The reader is unable to read the card. The reader has a 1. The reader's controller short read range. is not properly grounded. Corrective Action • • • 2. The shield wire for the • reader's cable has opened somewhere between the reader and the controller. 3. The reader is mounted • too close to a device that radiates electromagnetic interference. 4. The controller is mounted too close to a device that radiates electromagnetic interference. • 5. The reader is powered by a switching power supply. • Make sure you are using an access card that is compatible with the reader. Verify there is nothing that can interfere between the reader and the access card. Ensure there is a quality earth ground connection made to the controller. Refer to the controller's documentation for specific information regarding the earth ground connection. Verify the shield line from the controller to the reader is one continuous, connected line. Refer to the controller's installation documentation and verify the shield line is correctly connected to the controller. Devices such as computer monitors radiate electromagnetic interference that affects read range. When possible, relocate either the reader or the device to provide a greater distance between the two. Devices such as computer monitors radiate electromagnetic interference that affects the performance of the receiver board on the controller. When possible, relocate either the controller or the device to provide a greater distance between the two. Switching power supplies are EMI sources. Change to a linear, regulated power supply. 2305 Bering Drive San Jose, CA 95131 USA (800) 260-5265 (408) 435-8400 FAX (408) 577-1792 Web: www.kerisys.com E-mail: sales@kerisys.com 01815-001 Rev. H Page 8 of 8
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Tagged PDF : Yes Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c320 44.293068, Sun Jul 08 2007 18:10:11 Format : application/pdf Title : MS-3000 QSG.fm Creator : GGRIGSBY Create Date : 1999:07:19 13:37:55Z Creator Tool : FrameMaker 8.0 Modify Date : 2010:10:07 13:04:05-07:00 Metadata Date : 2010:10:07 13:04:05-07:00 Producer : Acrobat Distiller 9.3.3 (Windows) Document ID : uuid:7193c284-c6e5-4992-a772-f46db75d2bb8 Instance ID : uuid:c9cbd6db-cc32-428c-ba72-2963807b1926 Page Count : 8 Author : GGRIGSBYEXIF Metadata provided by EXIF.tools