Keyence 1399B Communication Unit User Manual Short Term Confidential
Keyence Corporation Communication Unit Short Term Confidential
Keyence >
(Short-Term Confidential) User Manual
 Precautions on LED products 96M13817 Handheld Code Reader CAUTION HR-100B HR-101B Series Instruction Manual Precautions on Proper Use Communication Unit HR-UC1 Desktop holder HR-PU1 CAUTION Introduction NOTICE Read this instruction manual before using the product in order to achieve maximum performance. Keep this instruction manual in a safe place after reading it so that it can be used at any time.  Symbols The following symbols alert you to important messages. Be sure to read these messages carefully. DANGER It indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING It indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION It indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Important Controls or adjustments other than those specified in this manual may result in a hazardous amount of LED exposure. Make sure to observe the following instructions. Otherwise, injury to the human body (eyes, skin, etc.) may result. ⢠Do not directly stare into the laser beams or specularly reflected light. ⢠This product is not equipped with a mechanism to stop laser emission when disassembled. Never disassemble this product. ⢠Do not directly stare into the laser beams using an optical apparatus. If you observe the laser beams with certain types of optical apparatus (e.g. loupe, magnifying glass, microscope) within the distance of 100 mm, injury to eyes may result. ⢠When using the HR-UC1/PU1, make sure to use the optional AC adaptor (OP-87530/88046). Using AC adaptors other than these may result in fire, electric shock, or product failures. ⢠Do not disassemble or modify the HR-100B Series. Doing so may damage the unit. ⢠The HR-100B Series is a precision instrument. Dropping this product or subjecting it to shock may cause damage. Be careful when carrying or using this unit. ⢠Do not allow water, oil, dust, or other foreign substances to stick to the scanner of the HR-100B Series. This may cause read errors. Use a soft, dry cloth to wipe any substance from the scanner. (Do not use a cloth dipped in alcohol or other cleaning substance.) ⢠Place cables as far away as possible from high-voltage lines and power lines. Otherwise, generated noise may cause product failure or operation errors. ⢠Do not hold the HR-100B Series by its cable. The main unit may strike the wall and may be damaged. Also due to the stress on the cables, the wires may break. ⢠Be sure to periodically clean the power connection part of AC adaptor connected to the OP-87530/88046 as it tends to catch dust. Tracking phenomenon may result in fire. Also, disconnect the AC adaptor from the outlet if not using for a long period of time. ⢠Use AC power cords that fit shapes of plugs used in each country and/ or region. Also, check if such cords comply with the relevant regulations and standards in each country and/ or region. Precautions on regulations and Standards  CE Marking Keyence Corporation has confirmed that this product complies with the essential requirements of the applicable EC Directive(s), based on the following specifications. Be sure to consider the following specifications when using this product in the Member States of European Union. It indicates a situation which, if not avoided, could result in product damage as well as property damage. It indicates cautions and limitations that must be followed during operation. z R&TTE Directive Point Reference It indicates additional information on proper operation. HR-100B, HR-101B and HR-UC1 comply with the requirements of the R&TTE Directive ⢠Declaration of Conformity for each country in accordance with the R&TTE Directive are listed at the end of this document. It indicates tips for better understanding or useful information. indicates the reference pages in this manual or the reference pages in separate manuals.  Trademarks  Precautions on Bluetooth ⢠Microsoft, Windows, Windows Vista/7/8 and Excel are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. WARNING Remove the main battery of HR-100B Series near locations where using wireless devices is banned at medical institutions or near electric devices for medical purposes. Carry and use the product away from an implanted cardiac pacemaker. Safety Precautions Important  General cautions DANGER ⢠This product is only intended to detect object(s). Do not use this product for the purpose to protect a human body or a part of human body. ⢠This product is not intended for use as an explosion-proof product. Do not use this product in a hazardous location and/or potentially explosive atmosphere. CAUTION ⢠At startup and during operation, be sure to monitor the functions and performance of this product and confirm normal operation. ⢠Take substantial safety measures to avoid any damage in the event that this product malfunctions. ⢠Using this product in applications other than specified in this manual is prohibited. Fire, electric shock or product failure may occur. NOTICE ⢠KEYENCE cannot guarantee the functionality or performance of units that have been modified or used with specifications other than those described in this manual. ⢠When the KEYENCE products are used in combination with other devices, functions and performance may be degraded, depending on the operating conditions and surrounding environment. ⢠Depending on the environment, communication may be impossible. Before starting actual operation, be sure to test the operation. ⢠If this product is used near devices with the same frequency band, such as a wireless LAN device, microwave oven, heating equipment for industrial use, high-frequency equipment for medical use, etc., radio wave interference may occur and the communication speed will become slow or communication may become impossible. ⢠Communication may be impossible at locations near metallic objects, locations surrounded with metallic walls or where there is a lot of metallic powder. ⢠Possible communication distance is approx. 10 m of vision, however, even within 10 m, communication may become impossible depending on the environment. Check the communication availability before using. ⢠With the frequency band for this unit, premise radio stations (license required), specified low power radio stations (license not required) and amateur radio stations (license required) for identifying mobile objects are operating. Those mobile objects are used for industrial, scientific and medical equipment, and also used for factory production lines. 1. Before using this unit, be sure to check that premise radio stations, specified low power radio stations and amateur radio stations for identifying mobile objects are not operating in the vicinity. 2. If radio wave interference occurs from the this unit against premise radio stations for identifying mobile objects, change the usable frequency immediately or stop the electric wave generation, and then contact the below phone number in regard to taking necessary measures (e.g. setting a partition) to avoid interference. E HR-100B-IM [Japan] ⢠Never disassemble or modify this unit as this conduct is prohibited by the Radio Act. This unit is specified radio equipment based on Japan's Radio Act, and has obtained a certification of construction type according to the standard specified by the Radio Act. [China]  Checking the Package   Main unit (HR-100B or HR-101B) . . .1  Instruction manual . . .1   Precautions on LED products 96M13817 Handheld Code Reader CAUTION HR-100B HR-101B Series Instruction Manual  Ŝ 使ç¨é˘çďź*+] Ĺś çćĺ ¨ĺčžĺ°ĺç (,53 ďź Â Read this instruction manual carefully prior to operating the HR-100B Series Handheld Code Reader.  Keep this manual in a safe place for future reference. NOTICE Introduction  Read this instruction manual before using the product in order to achieve maximum performance. Keep this instruction manual in a safe place after reading it so that it can be used at any time.  Symbols CAUTION The following symbols alert you to important messages. Be sure to read these messages carefully. DANGER WARNING CAUTION NOTICE Point Keyence Corporation has confirmed that this product complies with the essential requirements of the applicable EC Directive(s), based on the following specifications. Be sure to consider the following specifications when using this product in the Member States of European Union. indicates the reference pages in this manual or the reference pages in separate manuals. ÂCommunication cable   HR-1C3UN USB 3 m straight  HR-UC1 Desktop holder  HR-PU1  IC (Industry Canada) Regulations The HR-100B, HR-101B and HR-UC1 comply with the following regulations specified by the IC. ⢠Applicable regulation ICES-003 Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. L'exploitation est autorisĂŠe aux deux conditions suivantes : (1) l'appareil  ne doit pas produire de brouillage, et  (2) l'utilisateur de l'appareil doit accepter tout brouillage radioĂŠlectrique subi, mĂŞme si le brouillage est susceptible d'en compromettre le fonctionnement. Battery pack  HR-B1  Explanation of symbols AC adapter  OP-87530 This symbol indicates a separate collection for WEEE.  This symbol indicates the polarity of the power plug. E HR-100B-IM  KEYENCE cannot guarantee the functionality or performance of units that have been modified or used with specifications other than those described in this manual.  When the KEYENCE products are used in combination with other devices, functions and performance may be degraded, depending on the operating conditions and surrounding environment. Remove the main battery of HR-100B Series near locations where using wireless devices is banned at medical institutions or near electric devices for medical purposes. Carry and use the product away from an implanted cardiac pacemaker.  Depending on the environment, communication may be impossible. Before starting actual operation, be sure to test the operation.  If this product is used near devices with the same frequency band, such as a wireless LAN device, microwave oven, heating equipment for industrial use, high-frequency equipment for medical use, etc., radio wave interference may occur and the communication speed will become slow or communication may become impossible.  Communication may be impossible at locations near metallic objects, locations surrounded with metallic walls or where there is a lot of metallic powder.  Possible communication distance is approx. 10 m of vision, however, even within 10 m, communication may become impossible depending on the environment. Check the communication availability before using.  With the frequency band for this unit, premise radio stations (license required), specified low power radio stations (license not required) and amateur radio stations (license required) for identifying mobile objects are operating. Those mobile objects are used for industrial, scientific and medical equipment, and also used for factory production lines. 1. Before using this unit, be sure to check that premise radio stations, specified low power radio stations and amateur radio stations for identifying mobile objects are not operating in the vicinity. 2. If radio wave interference occurs from the this unit against premise radio stations for identifying mobile objects, change the usable frequency immediately or stop the electric wave generation, and then contact the below phone number in regard to taking necessary measures (e.g. setting a partition) to avoid interference. E HR-100B-IM  HR-1C5UC USB 5 m curl type Communication unit ⢠When using the HR-UC1, be sure to attach the ferrite core the nearest position of HR-UC1 to the communication cable and AC adapter. * Please use the following product for the ferrite core. Ferrite core(Manufacturer) : ZCAT3035-1330(TDK) The number of times of the turn : 2 turns ⢠When using the HR-UC1, be sure to provide Class D ground for installation location.  AC adapter polarity mark WARNING Important   HR-1C3UC USB 3 m curl type   HR-1C3RB RS-232C type for HR-UC1 HR-100B, HR-101B and HR-UC1 comply with the following regulations specified by the FCC. ⢠Applicable regulation FCC Part 15 Subpart B ClassB FCC Part 15 Subpart C ⢠This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interface, and (2) this device must accept any interference received, including interference that may cause undesired operation. This symbol indicates a direct current.  At startup and during operation, be sure to monitor the functions and performance of this product and confirm normal operation.  Take substantial safety measures to avoid any damage in the event that this product malfunctions.  Using this product in applications other than specified in this manual is prohibited. Fire, electric shock or product failure may occur. Options ÂÂFCC Regulations   This product is only intended to detect object(s). Do not use this product for the purpose to protect a human body or a part of human body.  This product is not intended for use as an explosion-proof product. Do not use this product in a hazardous location and/or potentially explosive atmosphere. [Thai] This telecommunication equipment conforms to NTC technical requirement.  WEEE DANGER CAUTION NOTICE 使ç¨ĺžŽĺçć çşżçľčŽžĺ¤ďźĺż 饝ĺżĺĺç§ć çşżçľä¸ĺĄç嚲ć°ć塼ä¸ăç§ĺŚĺĺťçĺş ç¨čŽžĺ¤çčžĺ°ĺš˛ć°ďź ä¸ĺžĺ¨éŁćşĺćşĺşéčżä˝żç¨ă   Precautions on Bluetooth Safety Precautions  General cautions 使ç¨ćśä¸ĺžĺŻšĺç§ĺćłçć çşżçľé俥ä¸ĺĄäş§çć厳嚲ć°ďźä¸ćŚĺç°ć嚲ć°ç°čąĄ ćśďźĺşçŤĺłĺć˘ä˝żç¨ďźĺšśéĺćŞć˝ćśé¤ĺš˛ć°ĺćšĺŻçť§çťä˝żç¨ďź  DC Mark HR-100B, HR-101B and HR-UC1 comply with the requirements of the R&TTE Directive  Declaration of Conformity for each country in accordance with the R&TTE Directive are listed at the end of this document.  Trademarks ä¸ĺžć čŞć´ćšĺĺ°é˘çăĺ 大ĺĺ°ĺç ĺ ćŹé˘ĺ¤ĺ čŁ ĺ°é˘ĺçćžĺ¤§ĺ¨ ďźä¸ĺžć čŞĺ¤ćĽĺ¤Šçşżććšç¨ĺ śĺŽĺĺ°ĺ¤Šçşżďź CAUTION It indicates cautions and limitations that must be followed during operation. It indicates additional information on proper operation. It indicates tips for better understanding or useful information.  Microsoft, Windows, Windows Vista and Excel are registered trademarks or trademarks of Microsoft Corporation in the United  States and other countries. Ĺś č˝˝é˘ĺŽšéďźSSP Ĺś ććŁĺĺ° čžĺ° ĺç 寚ĺşč˝˝ćł˘Âĺ俥éĺ¸ŚĺŽ˝äťĽĺ¤ ďź Â Â When using the HR-UC1/PU1, make sure to use the optional AC adaptor (OP-87530/88046). Using AC adaptors other than these may result in fire, electric shock, or product failures.  CE Marking It indicates a situation which, if not avoided, could result in product damage as well as property damage. z R&TTE Directive Important Reference ÂG%PN+] 0+] ÂG%PN+] *+] ÂG%P0+] *+] ÂG%P0+] *+] ÂG%P0+] ĺ śĺŽ*+]  Do not disassemble or modify the HR-100B Series. Doing so may damage the unit.  The HR-100B Series is a precision instrument. Dropping this product or subjecting it to shock may cause damage. Be careful when carrying or using this unit.  Do not allow water, oil, dust, or other foreign substances to stick to the scanner of the HR-100B Series. This may cause read errors. Use a soft, dry cloth to wipe any substance from the scanner. (Do not use a cloth dipped in alcohol or other cleaning substance.)  Place cables as far away as possible from high-voltage lines and power lines. Otherwise, generated noise may cause product failure or operation errors.  Do not hold the HR-100B Series by its cable. The main unit may strike the wall and may be damaged. Also due to the stress on the cables, the wires may break.  Be sure to periodically clean the power connection part of AC adaptor connected to the OP-87530/88046 as it tends to catch dust. Tracking phenomenon may result in fire. Also, disconnect the AC adaptor from the outlet if not using for a long period of time.  Use AC power cords that fit shapes of plugs used in each country and/ or region. Also, check if such cords comply with the relevant regulations and standards in each country and/ or region. Precautions on regulations and Standards It indicates a hazardous situation which, if not avoided, will result in death or serious injury. It indicates a hazardous situation which, if not avoided, could result in death or serious injury. It indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.  夊线ĺ˘çďźG%LćśďźÂP:ćÂG%P Ĺś ć大ĺçč°ąĺŻĺşŚďź 夊线ĺ˘çďźG%LćśďźÂG%P0+] (,53 Controls or adjustments other than those specified in this manual may result in a hazardous amount of LED exposure. Make sure to observe the following instructions. Otherwise, injury to the human body (eyes, skin, etc.) may result.  Do not directly stare into the laser beams or specularly reflected light.  This product is not equipped with a mechanism to stop laser emission when disassembled. Never disassemble this product.  Do not directly stare into the laser beams using an optical apparatus. If you observe the laser beams with certain types of optical apparatus (e.g. loupe, magnifying glass, microscope) within the distance of 100 mm, injury to eyes may result. Precautions on Proper Use Communication Unit HR-UC1 Desktop holder HR-PU1  Mark for opening and closing the lid. This symbol indicates the rotation direction to open or close the battery lid.  OP-88046  Part Names and Functions Buzzer Removing the battery cover Operation status LED: indicates the operation status. Rotate the screw counterclockwise to loosen it. Push the cover up and at an angle with your thumb to remove it. Reading window: Emits LED light and aimer and receives the reflected light. Trigger switch: Use this switch to read a code.  Operation status LED The operation status LED lights up as below according to the operation status. LED color Green Red Inserting the battery and securing the cover LED light-up timing ⢠When a code is read ⢠When a setting code is read in the setting mode Insert the battery straight in as shown in the figure below. Attach the cover to the hook and close it. ⢠When an operation error occurs when an operation is specified ⢠When an invalid setting code is read while reading a setting code Basic Operations Bring the reading window to the code and press the trigger switch. The LED light and the aimer indicating the reading position are emitted, and the code is read. Rotate the screw clockwise to secure the cover. Hook ⢠When the code is read, the operation status LED (green) lights up and the buzzer sounds. (The operation status LED and the buzzer can be disabled.) ⢠The read code data is sent to the connected PC or other equipment. Return the metal loop used to rotate the screw to the flat position. E HR-100B-IM [Communication unit] Connecting the communication cable Ĺś FCC Regulations Insert the connector straight in with the tab facing outward. HR-100B, HR-101B and HR-UC1 comply with the following regulations specified by the FCC. ⢠Applicable regulation FCC Part 15 Subpart B ClassB FCC Part 15 Subpart C ⢠This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interface, and (2) this device must accept any interference received, including interference that may cause undesired operation. [Communication unit/Desktop holder] Connecting the power cable Insert the AC cable into the AC adapter. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Insert the connector of the AC adapter as shown in the figure below. Pairing Read the barcode on the back of the communication unit. ăťThis equipment complies with FCC radiation exposure limits set forth for an controlled environment and meets the FCC radio frequency (RF) Exposure Guidelines. This equipment has very low levels of RF energy that is deemed to comply without testing of specific absorption rate(SAR). After a series of short beeps, a tone sounds if pairing is successful. ⢠When using the HR-UC1, be sure to attach the ferrite core the nearest position of HR-UC1 to the communication cable and AC adapter. * Please use the following product for the ferrite core. Ferrite core(Manufacturer) : ZCAT3035-1330(TDK) The number of times of the turn : 2 turns ⢠When using the HR-UC1, be sure to provide Class D ground for installation location. ăťFCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the userâs authority to operate the equipment. Ĺś IC (Industry Canada) Regulations The HR-100B, HR-101B and HR-UC1 comply with the following regulations specified by the IC. ⢠Applicable regulation ICES-003 ⢠This device complies with Industry Canadaâs licence-exempt RSSs. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. ⢠Le prĂŠsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.L'exploitation est autorisĂŠe aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioĂŠlectrique subi, mĂŞme si le brouillage est susceptible d'en compromettre le fonctionnement. ⢠This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment and meets RSS-102 of the IC radio frequency (RF) Exposure rules. This equipment has very low levels of RF energy that are deemed to comply without testing of specific absorption rate (SAR). ⢠Cet ĂŠquipement est conforme aux limites dâexposition aux rayonnements ĂŠnoncĂŠes pour un environnement non contrĂ´lĂŠ et respecte les règles dâexposition aux frĂŠquences radioĂŠlectriques (RF) CNR-102 de lâIC. Cet ĂŠquipement ĂŠmet une ĂŠnergie RF très faible qui est considĂŠrĂŠe comme conforme sans ĂŠvaluation du dĂŠbit dâabsorption spĂŠcifique (DAS). E HR-100B-IM General specifications  Handheld Code Reader Model Type Light-receiving part Light-emitting part (light and aimer) HR-101B High resolution type Sensor CMOS image sensor Number of pixels 838Ă640 pixels Light source Red LED LED class Exempt group (IEC62471) 2D Code QR, MicroQR, DataMatrix (ECC200) PDF417, MicroPDF417, GS1 Composite (CC-A/CC-B/CC-C), MaxiCode, AztecCode Barcode CODE39, ITF, 2of5 (Industrial 2of5), NW-7 (Codabar), CODE128, GS1-128, GS1 DataBar, CODE93, JAN/EAN/UPC, MSI, Postal, CODE11, 2of5 Supported symbol Reading specifications HR-100B Standard type Minimum resolution Reading distance (Typical examples) 2D code 0.169 mm 0.127 mm Barcode 0.127 mm 0.076 mm 2D code 15 mm to 180 mm (Cell size: 0.254 mm) 0 mm to 114 mm (Cell size: 0.254 mm) Barcode 25 mm to 115 mm (Narrow bar width: 0.127 mm) 0 mm to 96 mm (Narrow bar width: 0.127 mm) Focal distance Field of view in focal distance 100 mm 50 mm 106 mm Ă 80 mm 64 mm Ă 49 mm Standard Bluetooth Ver 2.1 Frequency Wireless 2.4 GHz bandwidth Broadcast output Class 2 Communication distance Approx. 10 m with few obstructions Baud rate Max 1 Mbps Ambient temperature 0°C to 50°C Ambient storage temperature -40°C to 70°C Ambient humidity Environmental resistance 5 to 95% (No condensation) Storage ambient humidity 5 to 95% (No condensation) Ambient luminance Sunlight: 10,000 lx, fluorescent lamp: 2,000 lx Drop impact resistance Concrete 1.8 m, 50 times Operating environment No dust or corrosive gas present Enclosure rating IP41 Model Battery HR-B1 Continuous usage time (typical value:1scan/s) 14 hours Approx. 4.5 hours with AC adapter Approx. 9 hours through USB bus power Charging time Dimension 161 mm Ă 86 mm (Head) Ă 71 mm (Head) Weight Approx. 225 g  Communication unit/Desktop holder Model HR-UC1 HR-PU1 Communication unit Desktop holder Bluetooth Ver 2.1 ASCII code â â â â â â â â â 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps â Type Standard Frequency Wireless 2.4 GHz bandwidth Broadcast output Class 2 Communication distance Approx. 10 m with few obstructions Baud rate USB Max 1 Mbps Standard USB Ver 1.1 (USB-HID, USB-COM) Supported OS Windows 8, 7, Vista, XP Synchronization method Asynchronous Transmission code Communication RS-232C Baud rate Data length 7/8 bit Parity check None/Odd/Even Stop bit length 1/2 bit Approx. 4.5 hours with AC adapter Approx. 9 hours through USB connection (HR-UC1 only) Charging time Ambient temperature (When not charging) 0°C to 50°C Ambient temperature (When charging) Environmental resistance 5°C to 40°C Ambient storage temperature -40°C to 70°C Ambient humidity 5 to 95% (No condensation) Storage ambient humidity 5 to 95% (No condensation) Drop impact resistance Concrete 1 m, 50 times Operating environment No dust or corrosive gas present Enclosure rating IP41 Power supply voltage Rating â â â DC 4.5 V to 5.5 V Current consumption (USB) 500 mA Current consumption (AC adapter) â 1000 mA Dimension 81 mm Ă 132 mm Ă 101 mm Weight Approx. 180 g E HR-100B-IM  Battery pack Model HR-B1 Type Lithium ion rechargeable battery Nominal output voltage 3.75 V Nominal capacity 2400 mAh Ambient storage temperature Environmental resistance -20°C to 60°C Storage ambient humidity 45 to 85% (No condensation) Dimension 21 mm x 22 mm x 100 mm Weight Approx. 65 g  Communication cable Model HR-1C3UN Cable type HR-1C3UC HR-1C5UC Straight Cable length Approx. 3 m Interface Connector Weight HR-1C3RB Curl Approx. 130 g Approx. 5 m Approx. 3 m USB RS-232C USB (A type) D-sub 9 pin (female) Approx. 130 g Approx. 200 g Approx. 160 g  AC adapter Model Rating OP-87530 Input Output OP-88046 AC100 to 240 V 50/60 Hz 0.27 to 0.17 A DC5 V Max. 2 A Ambient temperature Ambient storage temperature Dimension Weight E HR-100B-IM DC5 V Max. 2.5 A 0°C to 40°C -20°C to 60°C -10°C to 70°C 72 mm Ă 47 mm Ă 27 mm (excluding cables) 81 mm Ă 50 mm Ă 31 mm (excluding cables) Approx. 140 g Approx. 175 g  HR-1C3RB Dimensional Outline Drawings (Unit: mm)  HR-100B/101B Ď5 (34) 86 (34) 71 250Âą25(RETRACTED) 1650Âą150(EXTENDED) (Unit: mm) (Ď19) 250Âą20 (45) 43 (45) 910Âą20 220 (30) (15)  HR-UC1/PU1 161 (Unit: mm) 30  HR-1C3UN (16) (Ď19) Ď5 132 (Unit: mm) (45) 81 101  HR-B1 (33) (Unit: mm) 22 2980Âą20  HR-1C3UC (Unit: mm) 100 250Âą20 205Âą25(RETRACTED) 1650Âą150(EXTENDED) Ď5 21 (Ď19) (45)  OP-87530 (16) (26) Ď3.5 (47) (Unit: mm) (Ď8) (27) (72) 1800 (28) (33)  OP-88046 910Âą20 (Unit: mm)  HR-1C5UC (Unit: mm) 31 81 250Âą20 (16) 540Âą40(RETRACTED) 4300Âą150(EXTENDED) Ď5 50 (Ď19) (45) (33) 250Âą20 E HR-100B-IM Declaration of Conformity for Each Country in Accordance with the R&TTE Directive cs KEYENCE CORPORATION tĂmto prohlaĹĄuje, Ĺže tento HR-100B/HR-101B/ HR-UC1 je ve shodÄ se zĂĄkladnĂmi poĹžadavky a dalĹĄĂmi pÄĂsluĹĄnĂ˝mi ustanovenĂmi smÄrnice 1999/5/ES. da Undertegnede KEYENCE CORPORATION erklĂŚrer herved, at følgende udstyr HR-100B/HR-101B/HR-UC1 overholder de vĂŚsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Ă˝esky [Czech] Dansk [Danish] de Deutsch [German] et Eesti [Estonian] en English es EspaĂąol [Spanish] Käesolevaga kinnitab KEYENCE CORPORATION seadme HR-100B/ HR-101B/HR-UC1 vastavust direktiivi 1999/5/EĂ pĂľhinĂľuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. Hereby, KEYENCE CORPORATION, declares that this HR-100B/HR-101B/ HR-UC1 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Por medio de la presente KEYENCE CORPORATION declara que el HR-100B/HR-101B/HR-UC1 cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. ČÇź ČÇžČ ČÇšČČ ČČÇš KEYENCE CORPORATION ǝǞČČČǟǿ Č ČÇż HR-100B/ HR-101B/HR-UC1 ČČČČČ ČÄČČÇźČǚǿ ČČČ Č ČÇżČ Č ČČÇżČÇťÇźÇżČ ÇšČǚǿČÇžČÇźÇżČ Čǚǿ ČÇżČ ČČ ÇżČÇźČ ČČÇźČÇżČÇźČ ÇťÇżÇšČÇšČÇźÇżČ ČÇžČ Č ÇťÇžÄŤÇżÇšČ 1999/5/ÇźČ. fr Par la prĂŠsente KEYENCE CORPORATION dĂŠclare que l'appareil HR-100B/ HR-101B/HR-UC1 est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. it Con la presente KEYENCE CORPORATION dichiara che questo HR-100B/ HR-101B/HR-UC1 è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. lv Ar ĹĄo KEYENCE CORPORATION deklarĆ, ka HR-100B/HR-101B/HR-UC1 atbilst DirektĆŻvas 1999/5/EK bÇtiskajĆm prasĆŻbĆm un citiem ar to saistĆŻtajiem noteikumiem. lt Ĺ iuo KEYENCE CORPORATION deklaruoja, kad ĹĄis HR-100B/HR-101B/ HR-UC1 atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. nl Hierbij verklaart KEYENCE CORPORATION dat het toestel HR-100B/ HR-101B/HR-UC1 in overeenstemming is met de essentiĂŤle eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. mt Hawnhekk, KEYENCE CORPORATION, jiddikjara li dan HR-100B/HR-101B/ HR-UC1 jikkonforma mal-ĆŤtiĆĽijiet essenzjali u ma provvedimenti oĆŤrajn relevanti li hemm fid-Dirrettiva 1999/5/EC. hu AlulĂrott, KEYENCE CORPORATION nyilatkozom, hogy a HR-100B/ HR-101B/HR-UC1 megfelel a vonatkozĂł alapvetĂľ kĂśvetelmĂŠnyeknek ĂŠs az 1999/5/EC irĂĄnyelv egyĂŠb elĂľĂrĂĄsainak. Français [French] Italiano [Italian] Latviski [Latvian] LietuviÇ [Lithuanian] Nederlands [Dutch] Malti [Maltese] Magyar [Hungarian] pt PortuguĂŞs [Portuguese] KEYENCE CORPORATION izjavlja, da je ta HR-100B/HR-101B/HR-UC1 v skladu z bistvenimi zahtevami in ostalimi relevantnimi doloĂžili direktive 1999/5/ES. sk KEYENCE CORPORATION tĂ˝mto vyhlasuje, Ĺže HR-100B/HR-101B/ HR-UC1 spÄÄa zĂĄkladnĂŠ poĹžiadavky a vĹĄetky prĂsluĹĄnĂŠ ustanovenia Smernice 1999/5/ES. fi KEYENCE CORPORATION vakuuttaa täten että HR-100B/HR-101B/ HR-UC1 tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. sv Härmed intygar KEYENCE CORPORATION att denna HR-100B/HR-101B/ HR-UC1 stĂĽr I Ăśverensstämmelse med de väsentliga egenskapskrav och Ăśvriga relevanta bestämmelser som framgĂĽr av direktiv 1999/5/EG. is HĂŠr meĂ° lĂ˝sir KEYENCE CORPORATION yfir ĂžvĂ aĂ° HR-100B/HR-101B/ HR-UC1 er Ă samrĂŚmi viĂ° grunnkrĂśfur og aĂ°rar krĂśfur, sem gerĂ°ar eru Ă tilskipun 1999/5/EC. no KEYENCE CORPORATION erklĂŚrer herved at utstyret HR-100B/HR-101B/ HR-UC1 er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF. Slovensky [Slovak] Suomi [Finnish] Svenska [Swedish] Ăslenska [Icelandic] Norsk [Norwegian] BUYER'S TRANSFER OBLIGATIONS: If the Products/Samples purchased by Buyer are to be resold or delivered to a third party, Buyer must provide such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written information provided to Buyer pertaining to the Products/Samples. E 1101-3 KEYENCE CORPORATION declara que este HR-100B/HR-101B/HR-UC1 estĂĄ conforme com os requisitos essenciais e outras disposiçþes da Directiva 1999/5/CE. sl Slovensko [Slovenian] (1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples. Any Products found to be defective must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any action of Buyer, including but not limited to improper installation, improper interfacing, improper repair, unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Components which wear are not warranted. (2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are only suggestions, and it is Buyer's responsibility to ascertain the fitness of the Products for Buyerâs intended use. KEYENCE will not be responsible for any damages that may result from the use of the Products. (3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be used internally in humans, for human transportation, as safety devices or fail-safe systems, unless their written specifications state otherwise. Should any Products/Samples be used in such a manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage whatsoever arising out of any misuse of the Products/Samples. (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTYâS CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply. Hiermit erklärt KEYENCE CORPORATION, dass sich das Gerät HR-100B/ HR-101B/HR-UC1 in Ăbereinstimmung mit den grundlegenden Anforderungen und den Ăźbrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet. el ÇźČČČČČČČ [Greek] WARRANTIES AND DISCLAIMERS Copyright (c) 2015 KEYENCE CORPORATION. All rights reserved. E HR-100B-IM 13817E 1115-1 96M13817 Printed in Japan
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : KEYENCE CORPORATION Create Date : 2015:12:25 15:45:56+09:00 Modify Date : 2015:12:25 15:45:56+09:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2015:12:25 15:37:49+09:00 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : Handheld Code Reader HR-100B HR-101B Series Instruction Manual 96M13817 Creator : KEYENCE CORPORATION Document ID : uuid:3324701a-455e-4c14-a563-c9f5d8435eb2 Instance ID : uuid:10b7416a-255b-4700-a708-f69baba395f3 Producer : Acrobat Distiller 10.1.2 (Windows) Page Count : 8EXIF Metadata provided by EXIF.tools