Keymat Technology DS60 AXS Series S60 iClass SE PIN-Multiclass Contactless Reader User Manual S60 Engineering Manual

Keymat Technology Ltd AXS Series S60 iClass SE PIN-Multiclass Contactless Reader S60 Engineering Manual

Contents

Users manual

Download: Keymat Technology DS60 AXS Series S60 iClass SE PIN-Multiclass Contactless Reader User Manual S60 Engineering Manual
Mirror Download [FCC.gov]Keymat Technology DS60 AXS Series S60 iClass SE PIN-Multiclass Contactless Reader User Manual S60 Engineering Manual
Document ID3031765
Application IDU/OeiWJy+O50A5e197S3Lg==
Document DescriptionUsers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize52.66kB (658303 bits)
Date Submitted2016-06-17 00:00:00
Date Available2016-06-17 00:00:00
Creation Date2016-04-28 11:19:10
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2016-04-28 11:19:10
Document TitleMicrosoft Word - S60 Engineering Manual
Document CreatorPScript5.dll Version 5.2.2
Document Author: johns

Engineering Manual for
AXS Series S60 Keypads
AXS SERIES S60 iCLASS SE® PIN-Contactless Reader: This integrated keypad and contactless reader is rated for
continuous outdoor use in exposed, unsupervised locations. Featuring genuine HID® iCLASS SE®, Seos®, contactless
technology, this access control keypad offers enhanced security by dual factor authentication. Authorized access
through a secured door or barrier can be gained by entry of a valid PIN and/or presentation of an authorized 13.56
MHz contactless card, token or Seos® device.
Additionally available with HID® multiCLASS SE® for 13.56MHZ &125kHz credentials..
This manual is available from www.storm-interface.com/downloads.
Each product includes a datasheet with the essential information for installation.
Contents
Page
Product Range / Supported Credentials 2
Exploded View……………………….…
Dimensional Details …………………...
Installation ……………………………...
Removal ………………………………..
Typical Wiring ………………………….
Wiegand Format Configuration ………
Configuration …………………………..
Change History ………………………..
10
Specifications ………………………….
11
Regulatory Info / F.A.Q’s……………..
12
Whilst every effort is made to ensure details are correct at time of print, specifications are subject to change without notice.
HID ®, Seos® and iCLASS SE® are trademarks of HID Global Corporation / ASSA ABLOY AB.
Storm, Storm Interface and Storm AXS are trademarks of Keymat Technology Ltd.
Storm Interface products include technology protected by international patent and design registration.
Storm Interface is an ISO9001 registered company. Storm is a trading name of Keymat Technology Ltd
S60 Engineering Manual
Rev 1.5 Apr 2016
Page 1 of 12
www.storm-interface.com
© Copyright Storm Interface. 2016. All rights reserved
Engineering Manual for
AXS Series S60 Keypads
Product Range
Four products are included in the range. The S60, which has metal keys, and the S60i, which has illuminated white
polymer keys. The multiclass versions are correspondingly S60M and S60iM
Order Code
Description
DS601K20
DS602W20
DS601K2P
DS602W2P
AXS Series S60 iClass keypad, metal keys, mullion format
AXS Series S60i iClass keypad, illuminated keys, mullion format
AXS Series S60M Multiclass keypad, metal keys, mullion format
AXS Series S60iM Multiclass keypad, illuminated keys, mullion format
Supported Credentials
The following credentials are supported out of the box.
iCLASS® Seos®
16KB
ISO14443A
iCLASS SE®
SE (32K, 2K)
ISO15693
ISO14443B
iCLASS®
Legacy (16K, 32K. 2K/2 )
ISO15693
iCLASS®
SR (32K, 2K/2)
ISO15693
MIFARE®
Classic (4K, 1K )
ISO14443A
(requires config card)
SE (32K, 4K, 2K)
SR (32K/2)
NXP Ultralight
DESFire®
EV1 (8K SE, 4K, 2K, 1K)
ISO14443A
And additionally on Multiclass products
HID Prox
No ISO std for Prox
Additional options are available either factory set or via the use of a configuration card
(for example it is possible to read Sector instead of CSN on Mifare and Desfire cards). Contact us for details
S60 Engineering Manual
Rev 1.5 Apr 2016
Page 2 of 12
www.storm-interface.com
© Copyright Storm Interface. 2016. All rights reserved
Engineering Manual for
AXS Series S60 Keypads
Exploded View
The product is supplied as below, note this product is designed to be installed onto a smooth surface (not a brick wall).
FRONT ASSEMBLY
REAR PLATE (with sticky gasket)
FITTING KIT & DATASHEET
2 X POZI CSK SCREW #8
x ¾ inch
CABLE
ENTRY
PORT
1 X RELEASE TOOL
TAMPER
CONNECTION
S60 Engineering Manual
Rev 1.5 Apr 2016
Page 3 of 12
www.storm-interface.com
© Copyright Storm Interface. 2016. All rights reserved
Engineering Manual for
AXS Series S60 Keypads
Dimensional Details
For a CAD model of product / panel fix detail go to www.storm-interface.com/downloads
S60 Engineering Manual
Rev 1.5 Apr 2016
Page 4 of 12
www.storm-interface.com
© Copyright Storm Interface. 2016. All rights reserved
Engineering Manual for
AXS Series S60 Keypads
Installation
Mark and drill the cable hole and screw fix positions. Remove the release liner and stick the rear plate to the wall.
Fix the rear plate to the wall with 2 x countersink
Strip the cable ends
| 34mm | |6mm|
Make the wiring connections to the keypad.
#8 x ¾”
screws (on 150mm centres) , and feed through the cable
CONNECTIONS
+12 V
LED
BEEPER
USE 18-24AWG SOLID OR STRANDED
WIRE
STRIP WIRE TO 6MM BARE ENDS
PRESS DOWN ON CONNECTOR AS
SHOWN USING RELEASE TOOL
THEN PUSH IN WIRE
THEN RELEASE CONNECTOR TO
CLAMP WIRE
0V
TAMPER
WG0
WG1
Set the rear halo illumination switch SW13 to either ON (1) , OFF (2)
Fit the keypad to the rear plate : locate at top and then push at the bottom to engage clip
Recommended locations and wiring methods shall be in accordance with the National Electrical Code, ANSI/NFPA 70.
Use shielded cable
S60 Engineering Manual
Rev 1.5 Apr 2016
Page 5 of 12
(factory default shown is Position 1 : ON )
www.storm-interface.com
© Copyright Storm Interface. 2016. All rights reserved
Engineering Manual for
AXS Series S60 Keypads
Removal
Insert the release tool in the slot at the bottom of the product.
Push to release the spring clip at the base.
S60 Engineering Manual
Rev 1.5 Apr 2016
Page 6 of 12
www.storm-interface.com
© Copyright Storm Interface. 2016. All rights reserved
Engineering Manual for
AXS Series S60 Keypads
Typical Wiring
Below is a typical wiring schedule – in this case between the S60 and a Kantech KT-300 Controller
The S60 is shown connected to control Door 2.
Where there is an LED connection, usually the GREEN LED connection is appropriate
S60
+12V
LED
Buzzer
KT-300
READER PWR +12V
OUT DOOR 2 LED
OUT DOOR 2 BUZ
0V
READER PWR GND
TAMPER
Wiegand Data 0
Wiegand Data 1
READ2 Green
READ2 White
Shield
EGND
Do Not
Connect
Keypad
S60 Engineering Manual
Rev 1.5 Apr 2016
Page 7 of 12
www.storm-interface.com
© Copyright Storm Interface. 2016. All rights reserved
Engineering Manual for
AXS Series S60 Keypads
Weigand Formats
For Cards
The reader’s Wiegand output easily interfaces with most existing Wiegand protocol access control panels.
The reader reads standard HID format data and will output data as encoded.
For MIFARE® cards the default setting is that the card data will be output as 32 bit. However, it can be configured if
required by the use of a separate CONFIG card (supplied by Storm Interface on request) to output 26-bit, 32-bit,, 37bit, 56-bit, or 64-bit Wiegand formats, based on the card serial number.
For PIN
The keypad supports 4, 8, 26, 32, 4/32 and 8/32 bit wiegand format for the PIN data (factory default is 4 bit).
In 4 or 8 bit mode : for each key press the appropriate wiegand code is transmitted. (NB: no site code is sent)
In 26 or 32 bit mode : the entry code (up to 5 digits) is transmitted together with the site code.
(NB : if your entry code is less than 5 digits you must press #, this adds leading zeros.
For example, if you press 131#, then 00131 will be transmitted)
In 4/32 or 8/32 bit mode, then the key presses will be transmitted in 4 or 8 bit Wiegand format.
Alternatively, you can force the output to 32 bit Wiegand format (no site code) using the following sequence



Press *
Press your entry code (up to 10 characters maximum)
Press #
For example:
S60 Engineering Manual
Rev 1.5 Apr 2016
*123# will output 123 as 32 bit Weigand code (without site code)
Page 8 of 12
www.storm-interface.com
© Copyright Storm Interface. 2016. All rights reserved
Engineering Manual for
AXS Series S60 Keypads
Configuration
For 32 bit Wiegand, the site code
must be less than or equal to
‘65535’.
On power-up, you have the option to
For 26 bit communication the site
code must be less than or equal
to ‘00255’.
change the wiegand format,
change the site code, or
reset to defaults.
Power up and press the ‘#’ key within 3 sec and the red led will start flashing, then enter the engineering code ‘#725’.
On acceptance, the green LED will be displayed for 2 seconds and the buzzer will sound a confirmation beep.
If the unit is left unattended during programming then after 10 seconds it will timeout and drop back into Entry Mode.
Power up and press
# within 3 seconds
To Enter Programming Mode, press
# 725
To change
Wiegand format
Press
To select
4 bit format
Press
To select
8 bit format
Press
To select
26 bit format
Press
To select
32 bit format
Press
To select
4/32 bit format
Press
To select
8/32 bit format
Press
To reset to factory
defaults
Press
To change
Site Code
Press
Enter the new 5
digit site code

To exit programming menu
Press
Keypad is back in
Entry Mode , RED LED
is on
S60 Engineering Manual
Rev 1.5 Apr 2016
Page 9 of 12
www.storm-interface.com
© Copyright Storm Interface. 2016. All rights reserved
Engineering Manual for
AXS Series S60 Keypads
Specifications
Card Compatibility
iClass®, Mifare® serial number
Card Read Range
2-11 cm (depending on card)
Card Security
V1 Security (Elite security by special order only)
Coupling Frequency
13.56 MHz or 13.56MHz / 125kHz
Power supply
12V +/- 15% DC 500mA
Tamper detection
Normally closed (N.C.) to 0V tamper switch
Status Indication
RED/GREEN LED and/or BEEP as driven by the attached Controller
Dimensions
200mm H x 45mm W x 21mm D (max).
Packed Dims & Weight
225mm H x 55mm W x 80mm D. 160 grams
Operational Temperature
-35°C to +65°C
Weather Resistance
IP65
Vibration & Shock
ETSI 6M3
Impact Resistance
IK09 (10J Rating)
Immunity (ESD)
15kV air & contact
Cable distance to host
150m max, always use shielded cable.
Certifications
CE / FCC / UL294
S60 Engineering Manual
Rev 1.5 Apr 2016
ISO15693, ISO14443A&B (full list on page 2)
FCC ID 2AEEZ-DS60
Page 10 of 12
(Metal Key Version 200 grams)
IC 20014-DS60
www.storm-interface.com
© Copyright Storm Interface. 2016. All rights reserved
Engineering Manual for
AXS Series S60 Keypads
Change History
Engineering Manual
Date
Jan 2016
1 Apr 2016
Version
1.0
1.5
Details
Provisional Release
First Production Release
Product Firmware
Date
Version
4 Bit Version 1
8 Bit Version 1
Details
First Production Release at Rev 1
i.e. S604V01 is 4 bit version 1
1 Apr 2016
S60 Engineering Manual
Rev 1.5 Apr 2016
Page 11 of 12
www.storm-interface.com
© Copyright Storm Interface. 2016. All rights reserved
Engineering Manual for
AXS Series S60 Keypads
Regulatory Information
This device complies with Part 15 of the FCC Rules and Industry Canada licence exempt RSS standard(s).
Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d'en compromettre le fonctionnement.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment
F.A.Q’s
Q: The illumination on my S60 is not steady : it flickers noticeably.
A : Powering the S60 via long ( > 30m) cable lengths can lead to flicker on the keypad and backlight illumination
This is because the cable resistance causes voltage drops which are modulated by the HID module scanning
for a card
You can mitigate the flickering as follows:
1)
2)
3)
4)
Use lower resistance cable
Parallel wire two cables for the +12V connection and two cables for the Ground connection
Provide power locally to the S60
Switch off the blue backlight illumination’
S60 Engineering Manual
Rev 1.5 Apr 2016
Page 12 of 12
www.storm-interface.com
© Copyright Storm Interface. 2016. All rights reserved

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : johns
Create Date                     : 2016:04:28 11:19:10+01:00
Modify Date                     : 2016:04:28 11:19:10+01:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Format                          : application/pdf
Title                           : Microsoft Word - S60 Engineering Manual
Creator                         : johns
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:0d021f7b-93e7-499a-8152-465661335649
Instance ID                     : uuid:6372df77-f4eb-4aac-874c-1775231e31f7
Page Count                      : 12
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AEEZ-DS60

Navigation menu