FyrewatchTM Battery Operated Smoke Alarm Model i9030 (formerly Model 0913) Test Button Tests unit’s electronic circuitry, horn, and battery function Red LED Flashes every 30-40 seconds to indicate that the smoke alarm is receiving power Description Features and Benefits The Fyrewatch i9030 smoke alarm is a full size battery operated smoke alarm. The Fyrewatch unit utilizes ionization technology that protects against fast flaming fires and other types of fires. The i9030 is powered by a 9V battery, providing continuous protection, even during power outages. This easy to install unit includes a test button to verify the detection electronics are working as intended. The tamper resist feature makes your smoke alarm somewhat tamper resistant. This helps deter theft or tampering. • Test Button – Tests unit’s electronic circuitry, horn, and battery function. • Tamper Resist Locking Pin – Helps deter theft or tampering. • Battery Operated – Protects even during power outages. FyrewatchTM Battery Operated Smoke Alarm Model i9030 Architectural and Engineering Specifications Technical Specifications Model: i9030 The smoke alarm shall be Kidde Unit Number i9030 (part number 900-0159) or approved equal. It shall be powered by a 9V battery. The unit shall incorporate an ionization smoke sensor with nominal sensitivity of .64-1.35%/ft. The temperature operating range shall be between 40˚F and 100˚F (4˚C and 38˚C) and the humidity operating range shall be up to 85% relative humidity. The alarm can be installed on the surface of any wall or ceiling following the UL/NFPA/Manufacturer’s recommended placement guidelines. The unit shall provide optional tamper resistance that deters removal of the unit from the wall or ceiling. The alarm shall include a test button that will electronically simulate the presence of smoke and cause the unit to go into alarm. This sequence tests the unit’s electronics, battery and horn to ensure proper operation. The unit shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. In a smoke incident, the horn will sound in the repetitive manner – three (3) beeps, a pause, three (3) beeps, a pause. The unit shall also indicate a low battery warning utilizing a brief alarm chirp every 30-40 seconds for a minimum of seven (7) days. The unit shall at a minimum meet the requirements of UL217, NFPA72, (chapter 11 2002 edition) The State of California Fire Marshall, NFPA101 (One and two family dwellings) Federal Housing Authority (FHA). It shall also include a 3-year manufacturer’s limited warranty. Power Source: 9V Battery (included) Audio Alarm: 85dB at 10ft Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C) Humidity Range: up to 85% relative humidity (RH) Sensor: Ionization Size: 5” in diameter x 1.5” depth Weight: 1lb Interconnects: No LED: Red, normal operation Warranty: 3 year limited Ordering Information Includes 9V Carbon Zinc Battery Ordering Number UPC I 2 of 5 Pack Config. Pack Quantity Dimensions (w x d x h inches) Case Weight Cases per pallet 900-0159-006 0-47871-00159-0 100-47871-00159-7 CLAM Cut Case (6 Units) 6.10 x 11.70 x 7.60 3.25 lbs 140 **Not for sale by individual unit 1 1 UNIT 1016 Corporate Park Drive Mebane NC 27302 1-800-880-6788 www.kidde.com 6 MASTER PACK UNIT 20 CUT CASE 40 6 MASTER PACK CUT CASE Distributed by: KL-i9030 sheet Rev. 01-12-09
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23 Instance ID : uuid:83310a78-aa2e-dd4e-9671-c7af45c85228 Document ID : adobe:docid:indd:28083eb7-dcaf-11dd-a561-88aec3175518 Rendition Class : proof:pdf Derived From Instance ID : 28083eb6-dcaf-11dd-a561-88aec3175518 Derived From Document ID : adobe:docid:indd:7108a9a8-d1e9-11dd-a1b4-c164824339d5 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00, 72.00, 300.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00, 72.00, 300.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:487b5e00-51ae-bb45-907e-2f49abc265b8, uuid:c2250f46-d867-6846-9c2c-61ac5e365ed3, uuid:9D9E3138A7D7DD118A06DBC6C75FD2C6, uuid:8ACC8FE9B5D8DD1184449D90AB6965AD, uuid:bf7521cf-01d3-5b4c-860d-ded8f45f2f5b, uuid:487b5e00-51ae-bb45-907e-2f49abc265b8 Manifest Reference Document ID : uuid:8395CA79247411DBA45DA2BD062FD869, uuid:638C2C38E8C1DD11BC01A7A676AA7DE5, uuid:0AF8187F431411DB8C1CCB5260D5DCA1, uuid:301AACFAB3D8DD1184449D90AB6965AD, uuid:65F6BC6B2BE2DD11B7049AB6E41CC53B, uuid:8395CA79247411DBA45DA2BD062FD869 Create Date : 2010:04:08 13:27:32-04:00 Modify Date : 2010:04:08 13:28:01-04:00 Metadata Date : 2010:04:08 13:28:01-04:00 Creator Tool : Adobe InDesign CS3 (5.0) Thumbnail Format : JPEG Thumbnail Width : 1024 Thumbnail Height : 1024 Thumbnail Image : (Binary data 86770 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 2 Creator : Adobe InDesign CS3 (5.0)EXIF Metadata provided by EXIF.tools