Kidde I9030 Brochure

Fyrewatch 0913 Data_Sheet_Kidde_i9030_ENG

2015-06-12

: Kidde Kidde-I9030-Brochure-748882 kidde-i9030-brochure-748882 kidde pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadKidde Kidde-I9030-Brochure-  Kidde-i9030-brochure
Open PDF In BrowserView PDF
FyrewatchTM
Battery Operated Smoke Alarm
Model i9030

(formerly Model 0913)

Test Button
Tests unit’s electronic circuitry, horn, and
battery function
Red LED
Flashes every 30-40 seconds to indicate that
the smoke alarm is receiving power

Description

Features and Benefits

The Fyrewatch i9030 smoke alarm is a full size battery
operated smoke alarm. The Fyrewatch unit utilizes
ionization technology that protects against fast flaming
fires and other types of fires. The i9030 is powered by a
9V battery, providing continuous protection, even during
power outages. This easy to install unit includes a test
button to verify the detection electronics are working
as intended. The tamper resist feature makes your
smoke alarm somewhat tamper resistant. This helps
deter theft or tampering.

•	 Test Button – Tests unit’s electronic circuitry,
	 horn, and battery function.
•	 Tamper Resist Locking Pin – Helps deter theft
	 or tampering.
•	 Battery Operated – Protects even during
	 power outages.

FyrewatchTM
Battery Operated Smoke Alarm

Model i9030

Architectural and Engineering
Specifications

Technical Specifications
Model:	

i9030

The smoke alarm shall be Kidde Unit Number i9030 (part
number 900-0159) or approved equal. It shall be powered
by a 9V battery. The unit shall incorporate an ionization
smoke sensor with nominal sensitivity of .64-1.35%/ft. The
temperature operating range shall be between 40˚F and
100˚F (4˚C and 38˚C) and the humidity operating range shall
be up to 85% relative humidity.
	 The alarm can be installed on the surface of any wall or
ceiling following the UL/NFPA/Manufacturer’s recommended
placement guidelines. The unit shall provide optional tamper
resistance that deters removal of the unit from the wall or
ceiling.
	 The alarm shall include a test button that will electronically simulate the presence of smoke and cause the unit to
go into alarm. This sequence tests the unit’s electronics,
battery and horn to ensure proper operation.
	 The unit shall include a piezoelectric horn that is rated
at 85 decibels at 10 feet. In a smoke incident, the horn will
sound in the repetitive manner – three (3) beeps, a pause,
three (3) beeps, a pause.
	 The unit shall also indicate a low battery warning utilizing a brief alarm chirp every 30-40 seconds for a minimum
of seven (7) days.
	 The unit shall at a minimum meet the requirements
of UL217, NFPA72, (chapter 11 2002 edition) The State
of California Fire Marshall, NFPA101 (One and two family dwellings) Federal Housing Authority (FHA). It shall also
include a 3-year manufacturer’s limited warranty.

Power Source:	

9V Battery (included)

Audio Alarm:	

85dB at 10ft

Temperature Range:	 40˚F (4.4˚C) to 100˚F (37.8˚C)
Humidity Range:	

up to 85% relative humidity (RH)

Sensor:	

Ionization

Size:	

5” in diameter x 1.5” depth

Weight:	

1lb

Interconnects:	

No

LED:	

Red, normal operation

Warranty:	

3 year limited

Ordering Information
Includes 9V Carbon Zinc Battery
Ordering	
Number	

	
UPC	

	
I 2 of 5	

Pack	
Config.	

Pack	
Quantity 	

Dimensions	
(w x d x h inches)	

Case	
Weight	

Cases
per pallet

900-0159-006	

0-47871-00159-0	

100-47871-00159-7	

CLAM	

Cut Case (6 Units)	

6.10 x 11.70 x 7.60	

3.25 lbs	 140

**Not for sale by individual unit

1

1
UNIT

1016 Corporate Park Drive
Mebane NC 27302
1-800-880-6788
www.kidde.com

6
MASTER PACK

UNIT

20
CUT CASE

40

6
MASTER PACK

CUT CASE

Distributed by:

	

KL-i9030 sheet	

Rev. 01-12-09



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23
Instance ID                     : uuid:83310a78-aa2e-dd4e-9671-c7af45c85228
Document ID                     : adobe:docid:indd:28083eb7-dcaf-11dd-a561-88aec3175518
Rendition Class                 : proof:pdf
Derived From Instance ID        : 28083eb6-dcaf-11dd-a561-88aec3175518
Derived From Document ID        : adobe:docid:indd:7108a9a8-d1e9-11dd-a1b4-c164824339d5
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 300.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 300.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:487b5e00-51ae-bb45-907e-2f49abc265b8, uuid:c2250f46-d867-6846-9c2c-61ac5e365ed3, uuid:9D9E3138A7D7DD118A06DBC6C75FD2C6, uuid:8ACC8FE9B5D8DD1184449D90AB6965AD, uuid:bf7521cf-01d3-5b4c-860d-ded8f45f2f5b, uuid:487b5e00-51ae-bb45-907e-2f49abc265b8
Manifest Reference Document ID  : uuid:8395CA79247411DBA45DA2BD062FD869, uuid:638C2C38E8C1DD11BC01A7A676AA7DE5, uuid:0AF8187F431411DB8C1CCB5260D5DCA1, uuid:301AACFAB3D8DD1184449D90AB6965AD, uuid:65F6BC6B2BE2DD11B7049AB6E41CC53B, uuid:8395CA79247411DBA45DA2BD062FD869
Create Date                     : 2010:04:08 13:27:32-04:00
Modify Date                     : 2010:04:08 13:28:01-04:00
Metadata Date                   : 2010:04:08 13:28:01-04:00
Creator Tool                    : Adobe InDesign CS3 (5.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 1024
Thumbnail Height                : 1024
Thumbnail Image                 : (Binary data 86770 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS3 (5.0)
EXIF Metadata provided by EXIF.tools

Navigation menu