9758639

HOME APPLIANCES
R

Part No. 9758639

Tip Over Hazard
A child or adult can tip the range and be
killed.
Connect

anti=tip bracket to rear range foot.

Reconnect
is moved.

the anti=tip bracket, if the range

Failure to follow these instructions can
result in death or serious burns to children
and adults.

I
a

these

30" (76.2

O_So

iMPORTANT :
Installer: Leave installation instructions
with the homeowner.
Homeowner: Keep installation
instructions and anti:tip bracket
template for future reference.
Save installation Instructions for local
electrical inspector's use.

F
\

with

semf-cmeaning

thermal/convection

oven

Before

Cabinet

you start...

Your safety and the safety of others
are very important.
We have provided many important safety messages in
this manuaIand on your appliance. Always read and
obey all safety messages.
This is the safety aIert symb0i.

opening

dimensions

25" (63.5 cm) countertop depth (with or without backsplash)
and 24" (61 cm) base cabinet depth, 36" (91.4 cm) countertop

height

Freestanding

This symb0t aierts you to potential hazards
that can kiii or hurt you and others.
Ati safety messageswiii f0ii0w the safety alert symbol
and either the word "DANGER"or "WARNING". These
words mean:

"_ _3" (33 cm) max.
pper cabinet depth j

///_...._

_,_j.

30" (76.2 cm) cabinet

For minimum
clearance to

opening w_dth

***Note
cooktop, see

18" (45.7 cm)
upper side cabinet
to countertop

30" (76.2 cm)

(7.3,,cm_.t.._,_

opening width
(22.9 cm)

You can be killed or sed0usly injured if you don't
f0H0w instructions.
AII safety messageswilI teli you what the p0tentiai
hazard is, teli you how to reduce the chance of injury,
and teii you what can happen if the instructions are not
followed.

4" (10.2 cm) min. clearance
from both sides of range to
side wall or other
combustible material.
!

(I5.2 cm)

Gas line opening can be
located within this
area.

WARNING: _f the information
in this
manual is not followed exactmy, a fire
or expmosion may resuJt causing
property
damage, personal
injury or
death.

(25.4 cm) Outlet
located should
within be
the 18" x
10" (45.7 cmx 25.4 cm)

2" (5.1 cm)__

shaded area. 1
2-1/2" (6.4 cm)
floor gas line
opening if directly
below regulator

TO DO iF YOU SMELL

_

_h._//
I /

7/8" (2.2 cm) min.
required between
cabinet opening
and door or hinge
opening.

- Do not store or use gasoline or
other flammabme vapors and miquids in
the vicinity
of this or any other
appliance.
-WHAT

1

"_\

GAS

o Do not try to _ight any appliance.
o Do not touch

any e_ectrica_ switch

o Do not use any phone
building.

in your

o Immediately call your gas supplier
from a neighbor's
phone.
Follow the
gas supplier's
instructions.
o if you cannot reach your gas
supplier,
call the fire department.
- Installation and service must be
performed
by a qualified
instalmer,
service agency or the gas supplier.

30" (76.2 cm)
opening width

4 (10 2 cm) mln

other combustible

mater_i

--\

_//

(22.9 cm)

IMPORTANT:
Rear vent must be
installed on all slide-in
models for proper
ventilation. See Step 7,
Panel D.

(15.

3 _

(7.6 cm)

Countertop opening dimensions that are shown
must be used. Given dimensions provide required
clearances.
To eliminate the risk of burns or fire by reaching
over heated surface units, cabinet storage space
located above the surface units should be avoided.
If cabinet storage is to be provided, the risk can be
reduced by installing a range hood that projects
horizontally a minimum of 5 inches beyond the
bottom of the cabinets.

Gas line opening should
be located within this
shaded area.
floor gas line opening if
directly below regulator

(61 cm)

7/8" (2.2 cm) min. required between
pening and door or hinge
opening.

Read electrical and carpentry instructions.
Proper installation is your responsibility. A qualified
technician must install this range. Make sure you
have everything necessary for correct installation. It
is the customer's responsibility to make sure that
the countertop has been properly prepared and that
the installation clearances specified on the
model/serial rating plate are met. The model/serial
rating plate is located on the oven frame behind the
oven drawer.
Check location where range will be installed. The
range should be located for convenient use in the
kitchen. Recessed installations must provide
complete enclosure of the sides and rear of range.
All openings in the wall or floor where range is to be
installed must be sealed.
IMPORTANT: Some cabinet and building materials
are not designed to withstand the heat produced by
the oven for baking and self-cleaning. Check with
your builder or cabinet supplier to make sure that
the materials used will not discolor, delaminate or
sustain other damage.
It is the customer's responsibility:
To contact a qualified electrical installer.

Outlet should be
located within
the 18" x 10"
(45.7 x 25.4 cm)
shaded area.

To assure that the electrical installation is adequate
and in conformance with National Electrical Code,
ANSI/NFPA 70 -- latest edition*, or CSA Standard
C22.1, Canadian Electrical Code, Part 1 --latest
edition**, and all local codes and ordinances.
NOTE: This appliance is manufactured for use with
Natural Gas. Conversion to LR Gas can be made
using the kit included in your literature package.
NOTE: The metal chassis of the range must be
grounded in order for the control panel to work. If
the metal chassis of the range is not grounded, no
keypads will operate. Check with a qualified
electrician if you are not sure the range is
grounded.

IMPORTANT: Observe all governing codes and
ordinances.
Grounded electrical outlet is required. See
"Electrical requirements," Panel C.
Cabinet opening dimensions that are shown must
be used.
Do not pinch the power supply cord between the
range and the wall.
Do not seal range to side cabinets.
Copies of the standards listed may be obtained from:
*National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant'Valley Road
Cleveland, Ohio 44131-5575
*** NOTE: 24" (61 cm) min. when bottom of wood or
metal cabinet is protected by not less than 1/4"
(6.4 mm) flame retardant miltboard covered with not
tess than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020"
(0.5 mm) copper.
30" (76.2 cm) rain. clearance between the top of the
cooking platform and the bottom of an unprotected
wood or metal cabinet.

Panel A

ran

countertop
30

for

es:

preparation

ation:

_

(76.2 cm)
opening,
width

Assemble the required tools and parts before starting
instaiJation. Read and follow the instructions provided
with any tooJs listed here.
level

1/2"

p"

Phillips scewdriver

(63.5 cm)

flat-blade screwdriver or 5/16""(7.9 mm) nut driver

30-7/8"
(78.4 cm)
.

Formed or tiled countertop
trimmed 1/2" (1.3 cm)back
at front corners of
countertop opening.

/

3/8" ( 9.5 mm) ratchet
adjustable wrench
Cooktop sides of range fit over
edges of countertop opening.

The cooktop sides of the siidedn range fit over
the cutout edge of your countertop.

if countertop opening width is greater than
30" (76.2 cm), adjust the 1/2" (1.3 cm) dimension.

if you have a square finish (flat) countertop and
the opening width is 30" (76.2 cm), no
countertop preparation is required.

Countertop must be level. Place level on
countertop, first side to side; then front to back.
if countertop is not level, range will not be level
Oven must be level for satisfactory baking
conditions.

Formed front-edged countertops: Must have
molded edge shaved flat 1/2" (1.3 cm) from
each front corner of opening.
Tile countertops may need trim cut back
1/2" (1.3 cm) from each front corner andlor
rounded edge flattened.

measureing tape or ruler
hand or electric drill
wood floor: 1/8" (0.3 cm) drill bit
concrete/ceramic floor: 3116" (0.48 cm) carbidetipped masonry drill bit
• LR gas conversion requires: pin pick up (claw
attachment)
• 5/16" nut driver

ied for

arts sup
n:

uct dimensions
Freestanding

pliers
hammer

• burner grates and caps
• vent cap
• LR conversion orifice spud kit:

Range

1 - 0.95 mm (0.0374") cooktop (blue)
30" (76.2 cm)
range width

2 - 0.67 mm (0.0264") cooktop (bJack)
1 - 1.05 mm (0.0413") cooktop (green)
1 -#65

(0.0350") broil burner

36-1/8"
(91.8 cm)
cooktop
height

anti)-tig
_

44-3/8"
(112.7 cm)

-4
28

30" (76.2 cm)
rear vent width

(Bracket must be securely mounted to sub-floor.
Thickness of flooring may require longer screws to
anchor the bracket to sub-floor.)

j Jar

home installation

The installation of this range must conform to the
Manufactured Home Construction and Safety
Standards, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD, Part 280); or when such
standard is not appJicabJe,the Standard for
Manufactured Homes installations (Manufactured
Home Sites, Communities and Setups), ANSI
A225.1/NFPA 501A*, or with local codes.

Slide-in Range

1-1/2"
(3.8 cm)

(#10 x 1-1/2")

Mobile

_

(71.1 cm)
depth
with
handle

anchors
2 plastic

In Canada, the installation of this range must conform
with the current standards CAN/CSA-Z240 -- latest
edition**, or with local codes.

I

iMPORTANT:
Rear vent must not
be obstructed for
proper ventilation on
aJl sJidedn models.
See Step 7, Panel D.
36-1/8"
(91.8 cm)
cooktop
height

When this range is installed in a mobile home, it must
be secured to the floor during transit. Any method of
securing the range is adequate as long as it conforms
to the standards listed above.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
**CSA International
8501 East Pleasant'Valley Road
Cleveland, Ohio 44131-5575

(2.54 cm)
spacer
30"
(76.2 cm)
width
28"

(71.1 cm) ...
depth "_
with
handle

PaneJ B

The floor anti-tip bracket must
be instaJJed.To instaJJthe anti-tip
bracket shipped with the range,
see PaneJ D and the anti-tip
bracket template.

Gas supply
requirements

Explosion

Hazard

Use a new AGA or CSA approved
supply line.
install a shutoff vatve.
Securely tighten

If local codes permit, a new AGA/CSA
design=certified, 4=5 foot (122 =152.4 cm)
long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D.,
flexible metal appliance connector is
recommended for connecting this range to the gas
supply line. Do Not kink or damage the flexible
tubing when moving the range. A 1/2" (1.3 cm)
male pipe thread is needed for connection to
pressure regulator female pipe threads.

Electrical

gas

Plug into a grounded
shutoff valve -_

all gas connections.

of a qualified

person

include:

licensed heating personnel,
authorized gas company personnel,
authorized service personnel.

and

Failure to do so can result in death,
explosion, or fire.

in the State of Massachusetts,
installation instructions apply:

to gas s

• installations and repairs must be performed by
a qualified or licensed contractor, plumber, or
gasfitter qualified or licensed by the State of
Massachusetts.

frgdppo
s g:ssu

line, a combination of pipe fittings
must be used to obtain an in-line
connection to the range. All strains must be
removed from the supply and fuel lines so range
will be level and in line.

• If using a bali valve, it shall be a T=handle
type.
• A flexible gas connector, when used, must not
exceed 3 feet.

ge

The supply line shall be equipped with an
approved shutoff valve. This valve should
be located in the same room, but external
to the range, and should be in a location that
allows ease of opening and closing. Do Not block
access to shutoff valve.

the following

The regulator setting must be checked at
a minimum of 1 inch water column above
the manifold pressure. The inlet pressure
to the regulator should be as follows for operation:

Observe all governing codes and ordinances.

Natural gas:

IMPORTANT: Range must be connected to a
regulated gas supply.

Manifold pressure -- 5 inches
Maximum pressure -- 14 inches
LR gas:

This installation must conform with local
codes and ordinances. In the absence of
local codes, installations must conform
with American National Standard, National Fuel
Gas Code ANSI Z223.1 -- latest edition or CANI=
B149 --latest edition* installation codes.

Input ratings shown on the modeVsedal
rating plate are for elevations up to 2,000
feet (609.6 m). For elevations above
2,000 feet (609.6 m), ratings are reduced at a rate
of 4% for each 1,00O feet (304.8 m) above sea
level. (Not applicable for Canada.)

This range is equipped for use with
Natural gas. It is design=certified by
AGA/CSA for Natural and LR gas with
appropriate conversion. The model/serial rating
plate, located on the oven flame behind the
drawer, has information on the type of gas that can
be used. If this information does not agree with the
type of gas available, check with your KitchenAid
dealer.
Provide a gas supply line of 3/4" (1.9 cm)
rigid pipe to the range location. A smaller
size pipe on long runs may result in
insufficient gas supply. Pipe=joint compounds
appropriate for use with LR gas must be used.
With LR gas, piping or tubing size can be 1/2"
(1.3 cm) minimum. LR gas suppliers usually
determine the size and materials used on the
system.
Copies of the standards listed may be obtained from:
* CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575

Panel C

Shock Hazard
3oprong outtet.

Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.

"open" positio

ifconnected to L.P,have a qualified
person
make sure gas pressure does not exceed
14" water column.
Examples

requ

Manifold pressure -- 10 inches

Faiture to follow these instructions can result
in death, fire, or electrical shock.
If codes permit and a separate ground wire is
used, it is recommended that a qualified electrician
determine that the ground path is adequate.
Check with a qualified electrician if you are not
sure whether the range is properly grounded.
Do not ground to a gas pipe.
A 120=volt, 60=Hz, ACoonJy, 15=ampere, fused
electrical circuit is required. A time=delay fuse or
circuit breaker is recommended. It is recommended
that a separate circuit serving only this range be
provided.
Electronic ignition systems operate within wide
voltage limits, but proper ground and polarity are
necessary. In addition to checking that the outlet
provides 120=volt power and is correctly grounded,
the outlet must be checked by a qualified
electrician to see if it is wired with correct polarity.
The wiring diagram is included in the literature
package. The wiring diagram can also be found on
the back of the range.
NOTE: The metal chassis of the range must be
grounded in order for the control panel to work. if
the metal chassis of the range is not grounded, no
keypads will operate. Check with a qualified
electrician if you are in doubt as to whether the
metal chassis of range is grounded.

Maximum pressure -- 14 inches

Line pressure testing:
Testing above 1/2 psi (gauge): The range
and its individual shutoff vaN'e must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures greater than 1/2 psig (3.5 kPa).
Testing at 1/2 psi (gauge) or lower: The range must
be isolated from the gas supply piping system by
closing its individual manual shutoff valve during
any pressure testing of the gas supply piping
system at test pressures equal to or less than
1/2 psig (3.5 kPa).

Recommended

ground

method

For personal safety, this range is equipped with a
power supply cord having a 3=prong ground plug.
To minimize possible shock hazard, the cord must
be plugged into a mating 3=prong, ground=type
outlet, grounded in accordance with the National
Electrical Code, ANSVNFPA 70 -- latest edition*
or CSA Standard C22.1, Canadian Electrical Code,
Part 1, -- latest edition** and all local codes and
ordinances. If a mating outlet is not available, it is
the personal responsibility and obligation of the
customer to have a properly grounded, 3=prong
outlet installed by a qualified electrician.
WARNING : improper connection of the equipment=
grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or
servicemen if you are in doubt as to whether the
appliance is properly grounded. Do not modify the
plug provided with the appliance = if it will not fit the
outlet, have a proper outlet installed by a qualified
electrician.
power
suppty
cord.
....\

3-prong
ground-type

O
3-prong
ground plug

\
ground
prong

outlet

ow start...
W{th range in kitchen.
Put on safety glasses and gloves.
Remove shipping materials, tape and
protective film from range. Keep
cardboard bottom and shipping base under range.
Remove oven racks and parts package from inside
oven. If you have a slidezin range, remove back
vent package from range top. See Step 7 for
installation.

Tip Over Hazard
A chitd or adult can tip the range and be
killed.
Connect

antFtip

Reconnect
is moved.
cardboard
corner
posts

bracket to rear range foot.

the antFtip

bracket, if the range

Failure to follow these instructions
can
result in death or serious burns to cMIdren
and adults.

Take 4 cardboard corner posts from the
carton. Stack one cardboard corner post
on top of another. Repeat with the other
two corner posts. Place corner posts lengthwise on
the floor in back of range so corner posts will
support outer side edges of range as shown.

Excessive Weight Hazard
Use two or more people to move and install
range.
Faiture to follow this instruction can result
in back or other injury.
Firmly grasp the range and gently lay it on
its back on the cardboard corner posts.

Pull cardboard bottom and shipping base
firmly to remove.

25" (63.5 cm)
countertop over
24" (61 cm)
cabinet

.]
Line up holes in anti4ip bracket with mounting
holes in floor. Use the screws provided to fasten
anti-tip bracket to floor.
NOTE: Anti4ip bracket must be mounted securely
to the sub41oor. Depending on the thickness of
your flooring, longer screws may be necessary to
anchor the bracket to the sub-floor. Longer screws
are available from your local hardware store.

Move range close to cabinet opening.
Remove cardboard or hardboard from
under range.

anti-tip
bracket
template

E_

lace the anti4ip bracket template on the
floor in the cabinet opening so that the
left edge is against cabinet and the top
edge is against the rear wall, molding or cabinet.
If countertop is deeper than 25 inches (63.5 cm),
measure and mark a distance 25 inches (63.5 cm)
in from front of countertop opening and align
template with mark (or subtract 25 inches (63.5
cm) from the countertop depth and add the
difference to the corresponding dimension).

X

Press on front of storage drawer and
release to open. Pull open to first stop
position. Lift front of drawer to clear
white wheels in drawer guides. Remove drawer
and set it aside on a protected surface.

Countertop overhangs
cabinet side.
A = Difference between
couetertop depth and 25"
(63.5 cm).

Use an adjustable wrench to loosen the
leveling legs 1zl/2 turns.
_A

Place cardboard or hardboard in front of
range. Stand range back up onto
cardboard or hardboard.

Rear vent must
be installed.

anti-tip bracket
template

If countertop is not flush to the side of the cabinet
opening, align the left side of the template to allow
for the countertop overhang. Tape the freestanding
range anti-tip bracket template in place.

Carefully move range into final position.
Look under range (a flashlight may be
needed) to check that left rear leveling
leg is engaged in the anti-tip bracket. If leveling leg
is not properly engaged, remove and reposition the
anti-tip bracket to ensure that the leveling leg fits
properly in the anti-tip bracket.

Contact a qualified floor covering installer for the
best procedure of drilling mounting holes through
your type floor covering.
Before moving, slide range onto cardboard or
hardboard.
If you have a slideqn range, remove the
outside screws from rear trim on range.
Use screws to attach rear vent to range.

Check that the type of gas supply is
correct for this range. (See model/serial
rating plate.)

Place rack in oven. Place level on rack,
first side to side; then front to back. If
the range is not level, pull range
forward until the rear leveling leg is removed from
the anti-tip bracket. Adjust the leveling legs up or
down. Then slide range back into position. Check
that leveling leg is engaged in anti-tip bracket.

If connecting to LR Gas, follow directions in
Conversion Kit included in your literature package.
If connecting to Natural gas, go to Step 9.

NOTE: Oven must be level for satisfactory baking
conditions.

To mount anti4ip bracket to wood floor,
use the anti-tip bracket template to
E mark where to drill mounting holes. Use
a drill with a 1/8" (0.3 cm) drill bit to drill the two
mounting holes. Remove template from floor.
To mount anti-tip bracket to concrete or ceramic
floor, use the anti4ip bracket template to mark
where to drill mounting holes. Use a drill with a
3/16" (0.5 cm) masonry drill bit to drill the two
holes. Remove template from floor. Tap plastic
anchors into mounting holes in floor with hammer.

Panel D

AN connections must be wrench-tightened.
I2
___

3

m] flames
(some
models)
Adjust the
height
of top burner

pressure regulator
and valve assembly
3" (7.6 cm)
flexible
connector
connector

.......

manual
shutoff valve

The cooktop LOW burner flame should be a steady
blue flame approximately 1/4" (0.64 cm) high. It
can be adjusted using the adjustment screw in the
center of the valve stem. The valve stem is located
directly underneath the control knob.
if the LOW flame needs to be adjusted:
a. Remove the control knob.

1/2" (1.3 cm) flare union adapters
Assemble the flexible connector from
the gas supply pipe to the pressure
regulator, located in the lower [eft side
of the storage drawer area, in this order: shutoff
valve, 1/2" (1.3 cm) flare union adapter, flexible
connector, 1/2" (1.3 cm) flare union adapter. Sea[
aN openings in floor or wan wherever range is
instaNed.

with LRcompounds
gas to sealappropriate
aNgas
j for
Useuse
pipe-joint
m connections. If flexible connectors are
used, be certain connectors are not kinked.

b. Hold the knob stem with a pair of pliers. Use
a smaN flat-head screwdriver to
turn the screw located in the
center of the control knob stem
until the flame is the proper
size.
c. Replace the control adjustment
knob.
screw,
d. Test the flame by
turning the control from
"LO" to "HI", checking the
flame at each setting.
Top burner flame

high flame

conducted
to the
following
Test for gasaccording
leaks. Leak
testing
shaN be
m instructions:Test aN connections by
brushing on an approved non-corrosive leakdetection solution. Bubbles win show a leak.
Correct any leak found.

Check the operation of the
oven broil burner. Close the oven door.
Press the "BROIL:' pad. "500°F '' will
appear in the temperature display. Press the "Start"
pad. The oven broil burner should light in 50 to 60
seconds. This delay is normal. The oven safety
valve requires a certain time before it will open and
aNow gas to flow. The first time broil burner is
lighted, it may take longer to Nght because of air in
gas line. The first few times burner is used sparks
may appear. This is normal.
NOTL_:Oven door must be shut for broil burner to
operate.

Look through oven window to check
broil burner for proper flame. The flame
should have a uniform, light blue
appearance around the burner surface. No yellow
tips, blowing or lifting of the flame should occur.
NOTE: The first few times the broil burner is used,
yellow sparks may appear in the flame. This is
normal and will stop after burner has been used a
few times.

appearance:
towflame

line.
Wait avalve
few minutes
for the
i supply
Open the
shutoff
in the gas
m gas to move through the gas line.

Push "CANCEL/OFF" pad. Insert oven
bottom tabs into slots in oven burner
area. Check that tabs are correctly
placed in slots. If the oven bottom is not positioned
properly, poor baking performance could occur.
Replace oven racks.

Remove the oven rack. Remove the
oven bottom and place it on a protected
surface.

Press the "CANCEL/OFF" pad. If the
broil burner flame needs adjustment,
contact your KitchenAid dealer or
authorized service company for assistance.

B "8888"
should
appear in
clock display.
Plug into
a grounded
3 prong
outlet.
Push the
"BAKE"
padoven
and
j burner.
Checktheop
eration
of the
m ,350OF,, will appear in the temperature
display. Press the "Start" pad. "LO" will appear in
the display; then "170°R '' The oven burner should
light in 50 to 60 seconds. This delay is normal. The
oven safety valve requires a certain time before it
will open and allow gas to flow.

i25

2

vent
cap,
cooktop
burner
caps
mli Remove
and grates
from
parts
package.
Align
notches in burner caps with pins in
burner base. Burner caps should be level when
properly positioned. Place burner grates over
burners and caps. Place vent cap over vent dome.

/
,__

_\

burner
jgrate

vent

/9)Y" cap

#X

Electric ignitors are used to light the oven and broil
burners.
Do not insert any object into the opening of the
protective shield that surrounds the ignitor.
Do not clean the area.

vent

Insert storage drawer into slide rails
on sides of drawer opening. Lift front
of drawer slightly and push firmly to
close drawer.

dome

as conversion

oven

Electronic

Ignition

System

E

No attempt shall be made to convert the range
from the gas specified on the model/serial rating
plate for use with a different gas without consulting
the servicing gas supplier. An LR Gas Conversion
Kit is included in your literature package.

rear

Initial lighting and gas flame adjustments.
Cooktop and oven burners use electronic ignitors
in place of standing pilots. When the cooktop
control knob is turned to the "LITE" position, the
system creates a spark to light the burner. This
sparking continues as long as the control knob is
turned to "LITE".
When the oven control is turned to the desired
setting, a glow bar heats up bright orange and
ignites the gas. No sparking occurs and the glow
bar remains on while the burners operate.

OFF

locking screw

air shutter
rotate to
adjust for
proper
flame

oven burner
airshutter
tocation

'_o

_,4_9
LO

If burners do not light properly> turn cooktop control
knob to the "OFF" position. Check that the power
supply cord is plugged in and the circuit breaker or
fuse has not blown. Check that the gas shutoff
valves are set to the "OPEN" position. Repeat Step
22. If a burner does not light at this point, contact
your KitchenAid dealer or authorized service
company for assistance.

Panel E

flame
shouldburner
have for
a 1t2"
(1.3flame.
cm)
I2 6
1 This
Check
the oven
proper
m long inner cone of bluish:green, with an
outer mantle of dark blue, and should be clean and
soft in character. No yellow tips, blowing or lifting of
flame should occur.

I

I operation
Check the of
m the cooktop
burners. Push in and
turn each control knob
to the "LITE" position.
The flame should light
within 4 seconds. The
first time a burner is
lighted it may take
longer than 4 seconds
to light because of air in
gas line.

oven burner

oven burner

brass orifice
hood (nut)

locate the air shutter near the center
j If the °ven flame needs t° be adjusted'
m rear of range. Loosen the locking screw
and rotate the air shutter until the proper flame
appears. Tighten locking screw.

i27

To get the most efficient use from
your new range, read your Use and
Care Guide. Keep Installation
Instructions
and Guide close to
range

for easy reference.

If range does not
operate...
• Check that the circuit breaker is not tripped or the
house fuse blown.
• Check that the power supply cord is plugged into
the wall receptacle.
• Check that the gas supply is on.
• Check that the regulator shutoff valve is in the
"OPEN" position.

For cleaning

maintenance...

and

If removing the range is ever necessary for
cleaning or maintenance, shut off gas supply to
range. Disconnect the gas and electrical supply
If the gas or electrical supply is inaccessible, lift
the range slightly at the front and pull the range out
away from the wall. Pull the range out only as far
as necessary to disconnect the gas and electrical
supply lines.

If you need service...
In the event that your KitchenAid appliance should
need service, call the dealer from whom you
purchased the appliance or a KitchenAid-authorized
service company. A KitchenAid-authodzed service
company is listed in the Yellow Pages of your
telephone directory under "Appliances -- Household
-- Major -- Service and Repair"
You can also obtain the service company's name
and telephone number by dialing, free, within the
continental United States, the KitchenAid Consumer
Assistance Center telephone number,
1-800-422-1230. A special operator will tell you the
name and number of your nearest KitchenAidauthorized service company

If you need assistance...
The KitchenAid Consumer Assistance Center will
answer any questions about operating or
maintaining your range not covered in the
Installation Instructions. The KitchenAid Customer
Interaction Center is open 24 hours a day, 7 days a
week. Just dial 1-800-422-1230 -- the call is free
within the continental United States.
When you call, you will need the range model
number and serial number. Both numbers can be
found on the model/serial rating plate located on
the oven flame behind the oven drawer.
Part No. 9758639
@ 2004 KitchenAid.
@ Registered Trademark of KitchenAid, U.S.A.

1. Remove the storage drawer.
2. Shut off the gas supply to the range.
3. Slide range forward, away from the wall, just far
enough to disconnect the gas and electric supply
lines.
4. Slide range forward to complete cleaning or
maintenance.

Maintain the quality built into your KitchenAid appliance
-- call a KitchenAid-authorized service company

Moving

the range...

anti-tip bra_

range foot

Remove the range to complete cleaning or
maintenance.
Move range back into operating position. Remove
drawer. Level the range. Connect gas line to range
and check for leaks. Plug in range or reconnect
power. Make sure that left rear leveling leg is
engaged in the anti-tip bracket.

When moving range, slide range onto cardboard or
hardboard to prevent damaging the floor covering.
If removing the range is necessary for cleaning or
maintenance:

5. Making sure the anti=tip bracket is installed:
• Look for the anti=tip bracket securely attached
to floor.
• Slide range back so rear range foot is under
anti=tip bracket.
Tip Over Hazard
A child or adult can tip the range and be
killed.

6. Check that range is level.

Connect

8. Plug in range or reconnect power.

anti-tip

Reconnect
is moved.

7. Reconnect gas line to range and check for
leaks.

bracket to rear range foot.

the anti-tip

9. Reinstall storage drawer.

bracket, if the range

Failure to foltow these instructions
can
result in death or serious burns to chitdren
and adults.

tche

®
HOME APPUANCES

Prepared by KitchenAid, Benton Harbor, Michigan 49022

Printed in U.S.A.
03/2004



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 7
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Fri Apr 20 14:51:36 2007
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu