Kubota 7780 Users Manual
2015-02-09
: Kubota Kubota-7780-Users-Manual-569101 kubota-7780-users-manual-569101 kubota pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | ![]() |
Open PDF In Browser | View PDF |
7780-8P英文 05.5.25 11:36 AM ページ1 High Speed Refrigerated Centrifuge 7780 F m rinted in Japan Th sw sp op the CERTIFIED KUBOTA MFG. CORP. 7780-8P英文 05.5.25 11:37 AM ページ1 Max. 22,000 rpm/52,490 xg Max. 4 Liters Features ■ High Capacity Rotor Aluminium Rotor of 4 x 1 Liter at 15,760 xg ■ Auto Interlock Lid Lid can be opened/closed using one hand. • To close lid Push slightly and the lid locks automatically by an electrical interlock system • To open lid Press the lid open key and the lid opens automatically after releasing the interlock. A foot switch (optional) also enables hands-free lid opening. ■ Easy-to-use and convenient functions • Memory flashing function for easy spin-down (Patent pending) Automatically memorizes the duration of spin-down operation ranging from 1 to 90 seconds. Merely pressing the key the next time starts the spin-down procedure for the memorized duration. • Twenty (20) operation condition memory settings are available, with one-touch saving, access and operation possible. • Equipped with a tachometer port to comply with GMP requirements. Actual rotor speed is easy to check. • Acceleration and deceleration curve can be varied in three steps according to the type of sample and experimental conditions. • RCF (xg)-set operation function and stepped centrifugal force function • Integrator function that can attain optimization of centrifuging conditions. G·sec value (integrated RCF value) can be measured and the operation with this value set is possible. • The timer can be set up to 990 minutes or seconds. During hold operation, the elapsed time of operation is displayed. • Pre-cooling function enables the rotor to reach low temperatures before the experiments. Foot switch (Optional) The lid opens automatically when the switch is pressed. A newly designed gas spring produces smooth and quick opening, while hands-free opening makes the experiments easier. AG-1K4 Fixed Angle Rotor 4 x 1 Liter Light weight (made of Aluminium) (30% less than AG-5006 6x500mL in weight) CERTIFIED KUBOTA MFG. CORP. 7780-8P英文 05.5.25 11:32 AM ページ1 Specifications 64 cm width, 78 cm depth, 86 cm Height. Model Maximum Speed Maximum RCF Maximum Capacity Control system abnormality detected display ■ Safety pursued Acceleration / Deceleration Speed setting Speed indication RCF setting RCF indication Integrator setting and indication Timer setting and indication Acceleration and deceleration characteristics • 7780 conforms to International safety standard IEC 61010-2020. • The various alarm detector sensors secure operation. When the alarm is detected, the operation stops. • Safety is increased by a rotor setup condition sensor that detects whether or not the rotor is properly set on the driver shaft. (Patent pending) • Automatic rotor identification. (Patented, Patent pending) Rotor type is automatically identified. Acceleration and deceleration curves can be varied in three steps according to the type of sample and experimental conditions. Acceleration and/or deceleration commencement speed can be selected for the sample easy to stir. Density gradient method is also possible. Acceleration/deceleration characteristics graph ■ Sample temperature kept at 4°C ■ Design incorporates friendliness to the global environment and recycling A limited amount of plastic is used to reduce the load on the environment. Refrigerant Power requirements Rated voltage and Rated current Power consumption and Heat output Dimensions, weight Test standard (✳1) Those of projections are not included. All specifications and external appearance subjec * On Model 7780 only use KUBOTA made rotor * The rotor mentioned in the catalogue is usable o * Follow instructions given in the relevant Instruc rpm Speed (At the ambient temperature of 25°C. Please refer to the rotor.) Temperature setting and indication Rapid deceleration Slow deceleration 1,000 Super slow acceleration Super slow deceleration (Natural deceleration) Slow acceleration Rapid acceleration Time • For the super slow acceleration and the super slow deceleration, a characteristic change-over speed Na and Nb can be set from 0 to 22,000 rpm. • Natural deceleration starts at the change-over speed Nb. “TEMP LIMIT” lamp “TEMP” display “PROGRAM” key “TEMP” knob “SPEED” knob “SPEED” display “TIME” knob “TIME” key “TIME” display Safety Precautions For yo the ins operat Always discontinue use when phenomena listed DISCONTINUE at right appear. USE “MEMORY” “NORMAL” key display “STEP” key “Pre-cooling” key “DECEL” key “ACCEL” key “OPEN” key “FLASHING” key “PROGRAM” selection key “OPEN” lamp “STOP” key “START” key http://www.centrifuge. 29-9 Hongo 3-chome, Bunkyo Tel +81 3 3815 1331 Fax +81 E-mail: f-trade@kubotacorp.co Note: This catalogue is not for distribution in products shown are not for sale in these coun 7780-8P英文 05.5.25 11:32 AM ページ2 High RCF 36,530 xg ~ 21,000 xg Fixed Angle Rotor 250mL~1,000mL Cap support structure enables high g-force centrifugation without tube breakage. (excluding AG-6512C) (Patent pending) High g-force enables separation of sticky protein. Speed down or special tube is not necessary to prevent tube from breakage. Tube size diam. x length mm Max. Speed rpm Max. RCF xg At keeping 4℃ * Max. Speed Max. RCF rpm xg *showing maximum speed and RCF when keeping the sample at 4°C. (At the ambient temperature 25°C) AG-508CA 8x50mL Conical tube 8x15mL Conical tube * 30x117 17x121 16,500 16,500 36,530 35,920 15,200 15,200 30,990 30,480 11,500 11,500 21,000 17,590 11,500 11,500 21,000 17,590 *Adaptor (Code No.055-1250) is necessary. AG-6512C *3 12x50mL Conical tube 12x15mL Conical tube 30x117 17x121 ●50 mL conical tube (PP) with cap of 36 mm diameter or less made by BIO-BIK, CORNING, FALCON, GREINER, IWAKI, NUNC and SARSTEAD can be accommodated. 35 mL Oak ridge conical tube (PC, PPCO) made by NALGE NUNC is acceptable. ●AG-508CA can accommodate 15 mL conical tubes (PP) made by BIO-BIK, CORNING, FISHER and GREINER. AG-6512C can accommodate 15 mL conical tube (PP) made by any company. Plate Rotor Shield cover is useful for prevention against contamination. Useful for DNA extraction & purification, ethanol precipitation, purification of PCR product in PCR plate, elimination of Dye-terminator. Max.Size of Plate mm Max. Speed rpm Max. RCF xg 86(W)x128(D)x90(H) 5,000 4,390 RS-751GS *3,7 12x microplate 4x deepwell plate *Tray (Code No.055-6380) is necessary. with shield cover Sealing Adaptor fo RS-745GS *3,7 12x microplate 4x deepwell plate 86(W)x128(D)x90(H) 4,200 3,100 *Tray (Code No.055-6380) is necessary. Tray Code No.055-6380 (Optional) with shield cover High Speed Rotor AG-506R・AG-508R・AG-1008A・ AG-5004・AG-5006 12x 96 well plate 4x deepwell plate 4x squarewell plate 2 deepwell plate + filter plate 2x PCR plate Code No.* Nominal Capacity 055-4280 10mL Oak ridge type tube 055-4290 50mL Oak ridge type tube 055-4510 250mL Bottle RMP-89G 8x microplate 4x deepwell plate 86(W)x130(D)x89(H) 2,400 1,080 *Tray (Code No.055-6370) is available (optional). * Adaptor is made of Polyathetale and the FEP: Teflon FEP, PSF: Polysulfone, PC: 7780-8P英文 05.5.25 11:34 AM ページ2 250mL~1,000mL Large Volume Fixed Angle Rotor 7m Tube size diam. x length mm F Max. RCF xg At keeping 4℃* Max. Speed Max. RCF rpm ×g *showing maximum speed and RCF when keeping the sample at 4°C. (At the ambient temperature 25°C) AG-2506 6x250mL mple Max. Speed rpm 60∼62.4x119∼137 13,000 26,830 12,500 24,810 11,000 20,700 11,000 20,700 10,000 18,890 10,000 18,890 9,000 15,760 9,000 15,760 ●Tube adaptor is available for various capacities. As for details, please contact your dealer. AG-5004 *2,3 4x500mL 69∼70.2x155∼170.5 ●Tube adaptor is available for various capacities. As for details, please contact your dealer. UNC can AG-5006 *2,3 6x500mL 69∼70.2x155∼170.5 ●Tube adaptor is available for various capacities. As for details, please contact your dealer. on F AG-1K4 *3 4x1,000mL 95.5x198.5 sary. Sealing Adaptor for Biohazard-proof Sealing adaptor for high speed fixed angle rotor Available for 10 mL and 50 mL Oak ridge type tubes and 250 mL bottles. Autoclavable (121°C). sary. onal). for 10mL Oak ridge type tube Code No.055-4280 High Speed Rotor AG-506R・AG-508R・AG-1008A・ AG-5004・AG-5006 Code No.* Nominal Capacity 055-4280 10mL Oak ridge type tube FEP PSF PC PPCO 3114-0010 3115-0010 3118-0010 3119-0010 16.0x81.5 16.0x82.0 16.1x81.7 16.0x81.4 055-4290 50mL Oak ridge type tube FEP PSF PC PPCO 3114-0050 3115-0050 3118-0050 3119-0050 28.8x107.7 29.0x107.7 28.8x107.0 28.8x106.7 055-4510 250mL Bottle PPCO 3120-0250 PC 3122-0250 61.8x127.7 61.8x127.6 Tube Tube size Dia x length mm * Adaptor is made of Polyathetale and the cap of acrylic FEP: Teflon FEP, PSF: Polysulfone, PC: Polycarbonate, PPCO: Polypropylene copolymer for 50mL Oak ridge type tube Code No.055-4290 for 250mL bottle Code No.055-4510 Rotor Max. Speed rpm Max. RCF xg AG-506R 22,000 49,240 AG-508R 19,000 41,170 AG-1008A 15,500 34,110 AG-5004 11,000 20,160 AG-5006 10,000 18,450 7780-8P英文 05.5.25 11:36 AM ページ2 7mL~100mL Middle Volume Fixed Angle Rotor Micro Tube size diam. x length mm Max. Speed rpm Max. RCF xg At keeping 4℃* Max. Speed Max. RCF rpm ×g *showing maximum speed and RCF when keeping the sample at 4°C. (At the ambient temperature 25°C) e AG-716 *3 16x7mL 15.9∼16.4x60∼64 22,000 48,700 21,000 44,370 15.9∼16.4x103∼109 22,000 51,950 20,500 45,100 15.9∼16.4x103∼105 18,500 42,860 17,000 36,190 28.7∼29x103∼109 22,000 52,490 19,500 41,240 19,000 43,590 17,000 34,900 15,500 35,190 14,000 28,710 3,500 2,270 3,500 2,270 AG-1212 12x12mL AG-1224 *1,3 24x12mL AG-506R Swing *2 6x50mL ●Tube adaptor is available for various capacities. As for details, please contact your dealer. AG-508R *2 8x50mL 28.7∼29x103∼109 ●Tube adaptor is available for various capacities. As for details, please contact your dealer. AG-1008A *2,3 8x100mL 38x114 ●Tube adaptor is available for various capacities. As for details, please contact your dealer. RA-360G *3 24x15mL 16x126 ✽1 The RCF figure As to RCF of th ✽2 Sealing cap an your dealer for ✽3 Please confirm ✽4 RS-410G can ✽5 S17019 tube ra 12x15 mL coni 7780-8P英文 05.5.25 11:37 AM ページ2 Micro Rotor 4℃* Max. RCF ×g g the sample 44,370 Tube size diam. x length mm Max. Speed rpm Max. RCF xg Bucket Code No. Tube Rack Adaptor Code No. 9.5∼11.0x36∼42 7.0∼7.9x25∼34 5.4∼6.1x26∼48 5.9∼6.3x20∼24 22,000 22,000 22,000 15,000 44,370 39,500 43,830 16,100 ― ― ― ― ― 055-7590 055-7580 055-0500 9.5∼11.0x36∼42 7.0∼7.9x25∼34 5.4∼6.1x26∼48 5.9∼6.3x20∼24 13,500 13,500 13,500 13,500 24,250 *1 24,040 *1 23,640 *1 20,580 *1 ― ― ― ― ― 055-7590 055-7580 055-0500 AG-224 24x2mL 24x0.5mL 24x0.4mL 24x0.2mL PCR RA-159G *3 72x2mL 72x0.5mL 72x0.4mL 72x0.2mL PCR 45,100 RS-35G swinging bucket rotor 16x2mL 4x0.5mL 20x0.5mL 36x0.4mL 16x0.2mL PCR 36,190 *3 9.5∼11.0x36∼42 7.0∼7.9x25∼34 7.0∼7.9x25∼34 5.4∼6.1x26∼48 5.9∼6.3x20∼24 15,000 15,000 15,000 15,000 15,000 18,360 16,100 16,100 18,360 11,820 053-5130 053-5130 053-5140 053-5150 053-5130 ― ― ― ― 055-0500 28.7∼29x103∼109 11,500 20,700 ― ― Swinging Bucket Rotor RS-200G *3 4x50mL ●Tube adaptor is available for various capacities. As for details, please contact your dealer. 41,240 RS-410G *3,4 Sealing cap is available and is biohazard-proof. 48x2mL 10.7x42 48x5mL RIA tube 12.5x55∼75 48x7mL 12∼12.5x100∼112 28x7mL blood collecting tube 12.5∼13x75∼106 12x15mL Conical tube *5 16.5x120.6 12x15mL Conical tube *5 16.5x120.6 28x10mL blood collecting tube/15mL 15.5∼17x87∼110 4x50mL 34x110 4x50mL 27∼35.8x82∼110 4x50mL Conical tube 29.5x117 4x100mL 44∼45x110 4x200mL 56.5x104 Autoclavable (121°C) 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 4,160 attached to rotor S17008 4,160 attached to rotor S17006 4,160 attached to rotor S17007 4,160 attached to rotor S17027 4,160 attached to rotor S17019 4,470 *8 S13130 ― 4,160 attached to rotor S17015 4,160 attached to rotor S17050 4,160 attached to rotor 055-5670 4,160 attached to rotor S17049 4,160 attached to rotor S17100 4,160 attached to rotor ― 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 2,290 *8 2,190 *8 2,260 2,330 2,300 2,300 2,300 2,330 2,330 2,330 2,330 2,330 2,330 2,330 2.380 *8 34,900 RS-720G 28,710 80x2mL 9.5∼11x36∼42 96x6mL RIA tube 10∼12.3x65∼95 80x10mL 12.5∼13.8x65∼95 48x10mL blood collecting tube/15mL 15∼17.2x81∼110 68x5/7mL blood collecting tube *9 12.5∼13.7x62∼110 68x10mL blood collecting tube/15mL 15∼17.2x52∼110 28x15mL Conical tube 17x121 32x15mL Conical tube 17x121 8x50mL 27∼36.4x85∼110 16x50mL Conical tube 30x117 4x100mL 38∼46.5x75∼120 4x175mL Conical tube *6,8 61x118 4x200mL Conical tube *6,8 61x130 4x225mL Conical tube *6,8 61x137 4x250mL 60∼61.8x100∼130 053-5820 053-5820 053-5820 053-5820 053-5840 053-5840 053-5840 053-5820 053-5820 053-5820 053-5820 053-5820 053-5820 053-5820 053-5820 055-4800 055-4730 055-4740 055-4750 055-0260 ― ― 055-4780 055-4760 055-6070 055-4770 055-4850 055-4850 055-4850 055-4850 ― ― RS-1400GA *3 4x250/350mL 2,270 67∼71x100∼128 ✽1 The RCF figure shows RCF of the outer tube. As to RCF of the inside, please contact your local dealer. ✽2 Sealing cap and sealing adaptor for bio-hazard proof are available. Please contact your dealer for details. ✽3 Please confirm the delivery schedule with your dealer. ✽4 RS-410G can accommodate sealing cap (Code No.S17111) (optional). ✽5 S17019 tube rack cannot be accommodated with the sealing cap. Code No.S13130 12x15 mL conical bucket can accommodate sealing cap (Code No.S17111) (optional). 5,000/4,000 4,810/3,080 ✽6 175 mL conical tube is made by Falcon (Catalog No.352076) and requires a cushion (Catalog No.352090). 200 mL conical tube is made by Nalge Nunc (Catalog No. 376813) and requires a cushion (Catalog No.377585). 225 mL conical tube is made by Falcon (Catalog No.352075) and requires a cushion (Catalog No.352090). ✽7 Please check the strength of plates before using the centrifuge. The plate at the bottom may be damaged. ✽8 As to RCF display, please refer to Instruction and Service manual. ✽9 INSEPACK II 5/7 mL of Sekisui, VENOJECT II 5/7 mL of Terumo, NEOTUBE 5/7 mL of Nipro and VACUTAINER 5/7 mL of Beckton Dickenson can be used. 7780-8P英文 05.5.25 11:34 AM ページ1 Specifications Model 7780 Maximum Speed¡ Maximum RCF¡ Maximum Capacity¡ Control system¡ abnormality detected display¡ Acceleration / Deceleration¡ Speed setting¡ Speed indication¡ RCF setting¡ RCF indication¡ Integrator setting and indication¡ Timer setting and indication¡ Temperature setting and indication¡ Refrigerant¡ Power requirements¡ Rated voltage and Rated current¡ Power consumption and Heat output¡ Dimensions, weight¡ Test standard¡ 22,000rpm 52,490xg 4,000mL Micro-processor control (Brushless motor) Speed, RCF, Time, g·sec, Temperature, Acceleration & Deceleration, 20 channel memories Lid open, Imbalance, Over speed, Abnormally high temperature, Rotor mounting abnormality Function for detecting an occurrence of electrical abnormality in motor, inverter, lid interlock, speed sensor and temperature sensor. Three-level selectors; Rapid, Slow and Super Slow From 300 to 22,000rpm, 10rpm increments Digital display, From 0 to 22,500rpm, 10rpm increments From 10 to 52,490xg, 10xg increments Digital display, From 0 to 54,900xg, 10xg increments Digital display, From 1.00 to 9.99x10 9 g·sec Digital display, with Hold and Memory Flashing from 1 sec to 100 sec, in 1 sec increment from 100 sec to 990 sec, in 10 sec increments from 1 min to 100 min, in 1 min increment from 100 min to 990 min, in 10 min increments Digital display, 1˚C increments, Pre-cooling Temperature setting range –20˚C to +40˚C Temperature indication –20˚C to +43˚C R 404A Single phase AC220V±10%, 230V±10%, 50/60Hz, 30A 220/230V, 50/60Hz, 12A 3500W, 13MJ/h 64(W) x 78(D) x 86(H)cm✳1, 235kg IEC 61010-2-020 Class 1 (✳1) Those of projections are not included. All specifications and external appearance subject to change without notice. * On Model 7780 only use KUBOTA made rotor, adapter and tube rack. Do not attempt use rotors, adapters or tube racks made by other manufacturers. * The rotor mentioned in the catalogue is usable on other KUBOTA centrifuge models. For details, refer to the catalogues relevant to each model. * Follow instructions given in the relevant Instruction & Service Manual for operating centrifuges. Safety Precautions For your safe use of the equipments, be sure to read the instruction manual carefully before you start its operation. Parts may be adversely affected by heat, humidity and specimens or deteriorated by aging resulting in functional failures or may even lose their safety characteristic to cause accidents. •The rotor or bucket has been found to be damaged or corroded. Always discontinue •A burnt smell comes out of the equipment. use when •You receive a minor electrification when you touch the IMPORTANT phenomena listed equipment body by a naked hand. DISCONTINUE at right appear. •Some other abnormality or failure has been found occurring. USE To prevent occurrences of functional failures or accidents, turn off the power switch, pull out the power cable plug from the plug socket and be sure to contact your nearest Kubota Dealer, or an office of Kubota Corporation when there is no Kubota Dealer in your neighbourhood. http://www.centrifuge.jp 29-9 Hongo 3-chome, Bunkyo-ku, Tokyo 113-0033, Japan Tel +81 3 3815 1331 Fax +81 3 3814 2574 E-mail: f-trade@kubotacorp.co.jp Note: This catalogue is not for distribution in the USA, Canada, Mexico and Australia as products shown are not for sale in these countries. Copyright © 2005 KUBOTA CORPORATION F4, Printed in Japan
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2005:05:25 02:34:42Z Modify Date : 2005:05:25 15:24:24+09:00 Page Count : 8 Creation Date : 2005:05:25 02:34:42Z Mod Date : 2005:05:25 15:24:24+09:00 Producer : Acrobat Distiller 5.0 for Macintosh Metadata Date : 2005:05:25 15:24:24+09:00EXIF Metadata provided by EXIF.tools