Kyocera KWC-M200 Transmitter Module User Manual 82 M8862 1

Kyocera Communications, Inc Transmitter Module 82 M8862 1

user manual part 3

Download: Kyocera KWC-M200 Transmitter Module User Manual 82 M8862 1
Mirror Download [FCC.gov]Kyocera KWC-M200 Transmitter Module User Manual 82 M8862 1
Document ID513259
Application IDKb2O+G6LqUs8zCQ0MGEuSg==
Document Descriptionuser manual part 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize105.62kB (1320274 bits)
Date Submitted2005-02-08 00:00:00
Date Available2005-02-08 00:00:00
Creation Date2005-02-08 10:11:44
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2005-02-08 10:11:59
Document Title82-M8862-1.book
Document CreatorFrameMaker 6.0

jçÇìäÉ=qÉëíáåÖ=~åÇ=fåíÉÖê~íáçå
UOJjUUSOJN=oÉîK=MMP
11. Conical - Dual-Band for PCS & GPS
68
Manufacture: QUALCOMM Inc.
Model Number: CV90-53293
Rated Gain: 1 dBi at 1850 Mhz / 1.6 dBi at 1990 Mhz
Kyocera 200 Module Data Book
Kyocera Proprietary
UOJjUUSOJN=oÉîK=MMP
jçÇìäÉ=qÉëíáåÖ=~åÇ=fåíÉÖê~íáçå
12. Multi Mode/Multi Band for Cellular, PCS & GPS
Manufacture: QUALCOMM Inc.
Model Number: CV90-J2108
Rated Gain: 2.9 dBi at 1850 / 4dBi at 1990 Mhz
Module Testing and
Integration
Kyocera Proprietary
Kyocera 200 Module Data Book
69
jçÇìäÉ=qÉëíáåÖ=~åÇ=fåíÉÖê~íáçå
UOJjUUSOJN=oÉîK=MMP
c~Åíçêó=íÉëíë
Each Module undergoes functional testing per specifications using the RF test
connector. No radiated tests are performed. The 50 ohm coaxial RF interfaces are
verified. The manufactured end item needs to be verified for functionality of the
antenna system and audio circuits if used.
oÉÖ~êÇáåÖ=ÇÉîÉäçéãÉåí=~åÇ=íÉëíáåÖ=çÑ=lbj=ÇÉîáÅÉ=ìëáåÖ=jçÇìäÉW
OEM must follow standards for voice and data as indicated by TIA.
OEM must follow standards for AT commands to send data to the Module/phone.
OEM may require constant activation of device by desired carrier for ongoing
testing.
oÉÖ~êÇáåÖ=ÅÉêíáÑáÅ~íáçå=çÑ=ÇÉîáÅÉ=çå=Å~êêáÉêDë=åÉíïçêâ=Ñçê=rKpK=ã~êâÉíW
Upon accepting the Module as a tested component to the OEM’s device, the
carrier provides direction to the OEM as to further testing that may be required
on the OEM’s part.
Please note that service providers may require the OEM’s product to pass some
basic over-the-air testing before it can be active on a provider’s network. This will
ensure the service provider that the network will not be adversely affected
during an OEM’s product development.
70
Kyocera 200 Module Data Book
Kyocera Proprietary
NO
jçÇìäÉ=aÉîÉäçéÉêÛë háí
The Module Developer’s Kit (MDK) is used to assist in development of end-user
applications for the CDMA Module. The MDK facilitates integration through the
serial and digital codec pulse code modulation (PCM) interface options. Contents
of the MDK are illustrated below.
Module and
Interface Board
9-pin RS 232
Cable Assembly*
(qty: 2)
Audio Headset*
Travel Charger*
Module Documentation**
CD-ROM
MMCX-to-SMA
Adapter (qty: 2)
Module Developer’s Kit
* Kit may include alternate components.
** Documentation includes Data Book (this document), User’s Guide, and
Reference Guide.
Kyocera Proprietary
Kyocera 200 Module Data Book
71
jçÇìäÉ=aÉîÉäçéÉêÛë háí
UOJjUUSOJN=oÉîK=MMP
It should be clearly understood that the software in the MDK (specifically, the
code in the Kyocera 200 Module User’s Guide, 82-M8863-1) is provided for
sample purposes only. The MDK software is not warranted as the basis for a
deployed implementation.
72
Kyocera 200 Module Data Book
Kyocera Proprietary
Warranty and Product
Support
NP
t~êê~åíó=~åÇ=mêçÇìÅí=pìééçêí
The KWC CDMA Module Developer’s Kit arrives having been tested as described
in the Module Testing & Integration chapter. Testing should be duplicated at the
integrator’s/customer’s facility. KWC can provide advice as to the type of test
equipment needed.
This Module testing should be separate from the testing to be performed on the
end product (with the Module installed). KWC offers a warranty for the CDMA
Module, from the date of shipment from KWC’s facility. This warranty provides
the customer with a remedy for defective Modules within the warranty period
and subject to all other warranty provisions.
KWC requests that the integrator retain several Modules as backup in case of
failure. It is assumed that you maintain a first level of returned Module testing in
your QA department prior to returning the Module to KWC. This alleviates the
question of whether the failure is in the Module or the end product. “No trouble
found” (NTF) occurrences on Modules returned to KWC will result in fees. KWC
reserves the right, at its own discretion, to repair, replace, or issue a trade credit
for any defective Module under warranty.
Warranty repair excludes warranty claims on products that have been subject to
misuse, neglect, improper storage or installation, or that have been repaired,
modified, or altered by a facility other than a KWC-authorized service center or a
KWC-certified repair center. In all cases, the final testing of the KWC line is the
sole controlling determination of Module performance.
Kyocera Proprietary
Kyocera 200 Module Data Book
73
t~êê~åíó=~åÇ=mêçÇìÅí=pìééçêí
74
Kyoera 200 Module Data Book
UOJjUUSOJN=oÉîK=MMP
Kyocera Proprietary
jÉÅÜ~åáÅ~ä=péÉÅáÑáÅ~íáçåë
Mechanical
Specifications
NQ
j~íáåÖ=ÅçååÉÅíçêë
The following connectors mate with the Module.
Module RF Connector Mate
Standard MMCX plug, available from
several manufacturers including Amp,
Radiall, and Telegartner
Module Interface Connector Mate
Manufacturer: MOLEX Inc., www.molex.com
Manufacturer’s Part Number: 54230-0509
Kyocera MCN: 449-24545-0509
Mechanical
Specifications
Mechanical
Specifications
54230-0509 is the tape and reel version with only a fitting nail/solder tab for
retention. 54230-0508 is the tape and reel version with fitting nail and pcb peg
(goes into the pcb and helps pick and place alignment). Although the -0509 is not
on the Molex Web site, it is available.
Parts can be ordered based on the manufacturer’s part number, not Kyocera’s
internal MCN (Material Control Number).
Other suppliers for this part are:
Mechanical
Specifications
eeParts, Inc., http://www.eeparts.com
1150 Hayden Dr, Ste 100
Carrolton, TX 75006
Phone: 469-574-2333/Fax: 469-574-2389
Mechanical
Specifications
Sager Electronics, http://www.sager.com
97 Libbey Industrial Pkwy
Weymouth, MA 02189
Phone: 800-SAGER-800
aê~ïáåÖë
The following technical drawings are included in this chapter:
Kyocera Proprietary
Land pattern and pin assignment for Module interface mating connector
Mounting hole and land pattern placement guidelines with recommended
mounting hardware
Module overall dimensioned drawing
Module exploded view
Kyocera 200 Module Data Book
75
jÉÅÜ~åáÅ~ä=péÉÅáÑáÅ~íáçåë
UOJjUUSOJN=oÉîK=MMP
Land pattern and pin assignment for the Module interface mating connector
76
Kyocera 200 Module Data Book
Kyocera Proprietary
jÉÅÜ~åáÅ~ä=péÉÅáÑáÅ~íáçåë
Mechanical
Specifications
1.00
.039
51.80
2.039
UOJjUUSOJN=oÉîK=MMP
57.00
2.244
Mechanical
Specifications
Keep area clear of components
and conductive traces
33.75
13.29
4x
2.40
0.94
2x
31.75
1.250
Mechanical
Specifications
2x
Mechanical
Specifications
0.00
50.80
2.000 53.80
2.118
2x
29.17
1.148
3.00
.118
Pin 1
Mechanical
Specifications
0.00
8.00
.315
Mounting hole and land pattern placement guidelines
Kyocera Proprietary
Kyocera 200 Module Data Book
77
jÉÅÜ~åáÅ~ä=péÉÅáÑáÅ~íáçåë
UOJjUUSOJN=oÉîK=MMP
56.4
48.2
64.85
11.42
Module interface connector
Mounting holes (4X)
Module outside dimensions (mm)
78
Kyocera 200 Module Data Book
Kyocera Proprietary
UOJjUUSOJN=oÉîK=MMP
jÉÅÜ~åáÅ~ä=péÉÅáÑáÅ~íáçåë
Mechanical
Specifications
Label
Top cover
Mechanical
Specifications
Cover screws (6x)
CCA
Mechanical
Specifications
Mechanical
Specifications
Mounting holes (4X)
Module exploded view
Mechanical
Specifications
Kyocera Proprietary
Kyocera 200 Module Data Book
79
jÉÅÜ~åáÅ~ä=péÉÅáÑáÅ~íáçåë
80
Kyocera 200 Module Data Book
UOJjUUSOJN=oÉîK=MMP
Kyocera Proprietary
Assignments and Signal
Definitions
NR
^ëëáÖåãÉåíë=~åÇ=páÖå~ä=aÉÑáåáíáçåë
Assignments and Signal
Definitions
=páÖå~ä=ÇÉÑáåáíáçåë=çÑ=RMJéáå=jçÇìäÉ=áåíÉêÑ~ÅÉ=ÅçååÉÅíçê
EfåéìíLçìíéìí=~êÉ=áå=êÉÑÉêÉåÅÉ=íç=jçÇìäÉKF
Comment
Modem Signal Level
Type
VPH_PWR
Power to the CDMA
transceiver
3.6 VDC min to 4.2 VDC max
Power input(6)
GND
Signal and power return
GROUND
VPH_PWR
Power to the CDMA
transceiver
3.6 VDC min to 4.2 VDC max
GND
Signal and power return
GROUND
VPH_PWR
Power to the CDMA
transceiver
3.6 VDC min to 4.2 VDC max
GND
Signal and power return
GROUND
VPH_PWR
Power to the CDMA
transceiver
3.6 VDC min to 4.2 VDC max
GND
Signal and power return
GROUND
VPH_PWR
Power to the CDMA
transceiver
3.6 VDC min to 4.2 VDC max
10
GND
Signal and power return
GROUND
11
VEXT#
Indicates that external
power is being used
0 to VPH_PWR max
Analog control
12
N/C
No connection
13
N/C
No connection
14
LED_EN#
Enable external LED
0 to VPH_PWR max
Analog control
15
N/C
No connection
16
LED_DRV
External LED drive
10 mA LED drive
Analog output
Kyocera Proprietary
Power input(6)
Power input(6)
Power input(6)
Power input(6)
Kyocera 200 Module Data Book
81
Assignments and Signal
Definitions
Pin # Signal Name
Assignments and Signal Assignments and Signal
Definitions
Definitions
50-pin Module interface connector pin assignments (viewed looking down on connector)
^ëëáÖåãÉåíë=~åÇ=páÖå~ä=aÉÑáåáíáçåë
UOJjUUSOJN=oÉîK=MMP
=páÖå~ä=ÇÉÑáåáíáçåë=çÑ=RMJéáå=jçÇìäÉ=áåíÉêÑ~ÅÉ=ÅçååÉÅíçê
EfåéìíLçìíéìí=~êÉ=áå=êÉÑÉêÉåÅÉ=íç=jçÇìäÉKF
Pin # Signal Name
Comment
Modem Signal Level
Type
17
N/C
No connection
18
XCVR_DET
Indicates that transceiver
is on
19
N/C
No connection
20
N/C
No connection
21
XCVR_EN#
CDMA transceiver primary 0 to VPH_PWR max
power enable
Analog input
22
MSM_DP_TXD
UART1 - transmit data
VOH(min) = 2.4V,
VOL(max) = 0.5V
Digital output(1)
23
MSM_DP_RXD
UART1 - receive data
VIH(min) = 1.9V,
VIL(max) = 0.9V
24
MSM_DP_CTS#
UART1 - clear to send
VIH(min) = 1.9V,
VIL(max) = 0.9V
25
MSM_DP_RTS#
UART1 - ready for receive
VOH(min) = 2.4V,
VOL(max) = 0.5V
Digital output(1)
26
MSM_DP_DTR#
UART1 - data terminal
ready
VIH(min) = 1.9V,
VIL(max) = 0.9V
Digital
input(2,3)
27
MSM_DP_RI#
UART1 - ring indicator
VOH(min) = 2.4V,
VOL(max) = 0.5V
28
MSM_DP_DCD#
UART1 - data carrier detect VOH(min) = 2.4V,
VOL(max) = 0.5V
Digital output(1)
29
HS_PRES#
Headset detection input to
MSM
VIH(min) = 1.9V,
VIL(max) = 0.9V
Digital
input(2,3)
30
GND
Signal and power return
GROUND
31
MSM_DP_TXD2
UART2 - transmit data
VOH(min) = 2.4V,
VOL(max) = 0.5V
32
MSM_DP_RXD2
UART2 - receive data
VIH(min) = 1.9V,
VIL(max) = 0.9V
33
MSM_DP_CTS2#
UART2 - clear to send
VIH(min) = 1.9V,
VIL(max) = 0.9V
34
MSM_DP_RTS2#
UART2 - ready for receive
VOH(min) = 2.4V,
VOL(max) = 0.5V
35
GND
Signal and power return
GROUND
36
CAR_SCL
Analog Carkit SCL line
VOH(min) = 2.4V,
VOL(max) = 0.5V
37
CAR_SDA
Analog Carkit SDA line
VOH(min) = 2.4V,
VOL(max) = 0.5V
38
CAR_MIC+
Analog carkit microphone
input
VIH(min) = 1.9V,
VIL(max) = 0.9V
Analog input(2)
39
CAR_SPKR+
Analog Carkit Speaker
output
VOH(min) = 2.4V,
VOL(max) = 0.5V
Analog
output(1)
40
GND
Signal and power return
GROUND
82
Kyocera 200 Module Data Book
Digital output(2)
Digital input(2)
Digital input(2)
Digital output(1)
Digital output(1)
Digital input(2)
Digital input(2)
Digital output(1)
Input/output
Input/output(1)
Kyocera Proprietary
UOJjUUSOJN=oÉîK=MMP
^ëëáÖåãÉåíë=~åÇ=páÖå~ä=aÉÑáåáíáçåë
Assignments and Signal
Definitions
=páÖå~ä=ÇÉÑáåáíáçåë=çÑ=RMJéáå=jçÇìäÉ=áåíÉêÑ~ÅÉ=ÅçååÉÅíçê
EfåéìíLçìíéìí=~êÉ=áå=êÉÑÉêÉåÅÉ=íç=jçÇìäÉKF
Modem Signal Level
Type
41
HS_SPEAKER
Headset speaker audio
output
1.5Vpp, 8.8mW into 32 ohm
load
Analog
output(1)
42
GND
Signal and power return
GROUND
43
MAIN_MIC+
Main microphone positive
input
1.8VDC nominal, -3Mv rms
44
MAIN_MIC-
Handset microphone
negative terminal
GROUND
45
GND
Signal and power return
GROUND
46
EAR_SPKR+
Main speaker positive
audio output
1.2VDC nominal,
3V pp with pin 47
47
EAR_SPKR-
Main speaker negative
audio terminal
1.2VDC nominal,
3V pp with pin 46
48
HS_MIC+
Headset microphone input 1.8VDC nominal, ~3Mv rms
49
GND
Ground for headset
microphone
GROUND
50
LSPKR_ON
Loudspeaker amp control
output
VOH(min) = 2.4V,
VOL(max) = 0.5V
Electret
microphone
input(4)
Bridge amp
output(5)
Electret
microphone
input(4)
Digital output(2)
Notes:
1. Input connected directly to MSM. Do not exceed V(max) of 3.1V; damage to MSM may result.
2. Output connected directly to MSM. Do not exceed V(max) of 2.8V; damage to MSM may result.
3. 10K ohm pull-up resistor inside Module.
4. Input for standard electret microphone. 1.8V supplied via 2.2K ohm resistor inside Module.
5. Pins 46 and 47 are bridge (differential) amp outputs capable of driving 35 mW into a 32 ohm speaker
connected between these pins.
6. 1200 mA required for full analog transmission capabilities.
Assignments and Signal Assignments and Signal
Definitions
Definitions
Comment
Assignments and Signal
Definitions
Pin # Signal Name
Assignments and Signal
Definitions
Kyocera Proprietary
Kyocera 200 Module Data Book
83
^ëëáÖåãÉåíë=~åÇ=páÖå~ä=aÉÑáåáíáçåë
84
Kyocera 200 Module Data Book
UOJjUUSOJN=oÉîK=MMP
Kyocera Proprietary
Module Developer’s Kit
Schematic
NS
jçÇìäÉ=aÉîÉäçéÉêÛë=háí=pÅÜÉã~íáÅ
Module Developer’s Kit
Schematic
There are two earlier versions of the Module Developer’s Kit (MDK) interface
board.
If the interface board in your MDK has an identifier of either K4020 or K4021,
you may request a schematic diagram by emailing
module-support@kyocera-wireless.com.
Module Developer’s Kit
Schematic
Module Developer’s Kit
Schematic
Module Developer’s Kit
Schematic
Kyocera Proprietary
Kyocera 200 Module Data Book
85
jçÇìäÉ=aÉîÉäçéÉêÛë=háí=pÅÜÉã~íáÅ
86
Kyocera 200 Module Data Book
UOJjUUSOJN=oÉîK=MMP
Kyocera Proprietary

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2005:02:08 10:11:59-05:00
Create Date                     : 2005:02:08 10:11:44-05:00
Title                           : 82-M8862-1.book
Creator                         : FrameMaker 6.0
Producer                        : Acrobat Distiller 4.0 for Windows
Page Count                      : 19
Mod Date                        : 2005:02:08 10:11:59-05:00
Creation Date                   : 2005:02:08 10:11:44-05:00
Metadata Date                   : 2005:02:08 10:11:59-05:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OVFKWC-M200

Navigation menu