LANKE XUNTONG TECHNOLOGY DTR6818 Bluetooth 4.0 module User Manual rev 2
LANKE XUNTONG TECHNOLOGY CO.,LTD Bluetooth 4.0 module rev 2
User Manual-rev 2
DTR6818 --Bluetooth 4.0 Module Coin-size Ultra Low Power Bluetooth 4.0 Low Energy RF Module Features Complete Bluetooth low energy solution (Bluetooth 4.0),single mode compliant,Integrated Bluetooth low energy stack/profiles. 2.4 GHz transceiver om • -93 dBm sensitivity in Bluetooth® low energy mode, -96 dBm sensitivity@250kbps, .c • TX Power -20 to +4 dBm in 4 dB steps • 13 mA peak RX, 10.5 mA peak TX (0 dBm) ARM® Cortex™-M0 32 bit processor, 256 kB flash memory, 16 kB RAM. • 150 μA/MHz running from RAM • Serial Wire Debug (SWD) hi • 275 μA/MHz running from flash memory Ultra low current consumption , Flexible Power Management qc na • RSSI (1 dB resolution) • Supply voltage range 1.8 V to 3.6 V • 2.5 μs wake-up using 16 MHz RCOSC fr • 0.4 μA @ 3 V OFF mode • 0.5 μA @ 3 V in OFF mode + 1 region RAM retention ww w. • 2.3 μA @ 3 V ON mode, all blocks IDLE Flexible real-time counter and Two 16 bit and one 24 bit timers with counter mode AES Coprocessor, Random Number Generator ,Watchdog Timer ,Temperature sensor Rich set of Peripheral: ADC, SPI, 2-wire , and UART. Programmable Peripheral Interconnect(PPI) Internal RC Oscillator 32.768 kHz(± 250 ppm). Configurable I/O mapping (I/O signals can use any pin, Simple layout of external application) Ultra small size(smaller than CR2032 coin battery), about 15mmx15mmx2.5mm with Antenna. COPYRIGHT ©2015 ALL RIGHTS RESERVED LANKE XUNTONG TECHNOLOGY CO.,LTD TEL: +86 755 26674742 +86 755 26675941 E-mail: nrf@freqchina.com Typical Applications: om - 2.4 GHz Bluetooth low energy systems - Proprietary 2.4 GHz systems - Sports and leisure equipment - Mobile phone accessories - Health Care and Medical - Consumer Electronics, Game pads - Human Interface Devices, Remote control - Building environment control / monitoring - RFID, Security Applications Name P0.08 P0.09 P0.12 SWDIO SWCLK P0.17 P0.18 P0.19 GND VDD P0.25 P0.26 P0.27 P0.28 P0.29 Description I/O I/O I/O Debug and flash programming I/O Debug and flash programming I/O I/O I/O I/O Power Ground Power Suply(1.9~3.6V) I/O I/O I/O I/O I/O Note ww w. Pin No. 10 11 12 13 14 15 fr qc hi na Pin Description of Module(Top View): .c ADC IN 0 ADC IN 1 COPYRIGHT ©2015 ALL RIGHTS RESERVED LANKE XUNTONG TECHNOLOGY CO.,LTD TEL: +86 755 26674742 +86 755 26675941 E-mail: nrf@freqchina.com fr qc hi na .c om Block diagram: HW debug and flash programming of Module : Pin Flash Program interface Debug and flash programming I/O SWCLK Debug and flash programming I/O ww w. SWDIO This is the hardware debug and flash programming of module, J-Link Lite support, pleas refer www.segger.com. COPYRIGHT ©2015 ALL RIGHTS RESERVED LANKE XUNTONG TECHNOLOGY CO.,LTD TEL: +86 755 26674742 +86 755 26675941 E-mail: nrf@freqchina.com Performance Data: om Transmitter specification: qc hi na .c Receiver specification: ww w. fr Radio current consumption: COPYRIGHT ©2015 ALL RIGHTS RESERVED LANKE XUNTONG TECHNOLOGY CO.,LTD TEL: +86 755 26674742 +86 755 26675941 E-mail: nrf@freqchina.com om CPU current consumption: fr qc hi na .c Power management: For more detail information, please refer nRF51822 datasheet. ww w. PCB Layout(TOP VIEW): COPYRIGHT ©2015 ALL RIGHTS RESERVED LANKE XUNTONG TECHNOLOGY CO.,LTD TEL: +86 755 26674742 +86 755 26675941 E-mail: nrf@freqchina.com unit: mil PIN Description NO PIN INPUT\ OUTPUT Description EN TX UART TX RX UART RX — — Not used — — Not used Input signal to wake up MCU (Optional) 0:Means module’s sending data to MCU , Master’s ready to receive data from Module 1:Means no data sending to MCU, or Module data sending Finished RTS ww w. .c na hi qc CTS fr om Enabled Pins,External Pull up: Falling Edge:Module starts Broadcasting, and connect with device Raising Edge:No matter what status of the module, the module will enter into deep sleep mode. (420 nA) Data output request to wake up module 0:Means MCU will send data out, and Module is waiting for the data from MCU 1:Means no data sending to module, or MCU data sending finished FLOW_CTR UART Flow Control: 0:UART can send data to module 1:Module is busy, UART can’t send data to Module Note:TO Prevent UART data from losing, suggest to check the pin status before MCU sending data, waiting for a falling edge , then send data out ( wait for no longer than a broadcasting or an interval ) , see the Chart 3-1 for reference. GND — Power Ground 10 VCC — Power Supply’ Positive(3 ~ 3.6V) COPYRIGHT ©2015 ALL RIGHTS RESERVED LANKE XUNTONG TECHNOLOGY CO.,LTD TEL: +86 755 26674742 +86 755 26675941 E-mail: nrf@freqchina.com 12 BAUD_0 13 BAUD_1 CNITV_0 15 CNITV_1 Set Connection Interval(Under Simple Mode),Internal Pull down: CNITV_0, CNITV_1: 00: 20ms 01: 100ms 10: 500ms 11: 1000ms hi 14 Set Baud Rate(Under Simple Mode),Internal Pull down: BAUD_0, BAUD_1: 00: 9600 01: 19200 10: 38400 11: 115200 om .c CFG_MODE na 11 Select Parameter configuration mode, interval pull up 0:Simple mode: Input level to set Baud Rate through BAUD_0、BAUD_ Input level to set Connection Interval through CNITV_0、CNITV_1 1:AT command mode: Sending AT command through UART to set Baud Rate and Connection Interval 。 qc Pls note that ; ww w. fr 1. This User Manual is a guide for OEM /Integrators , is Limited for OEM/Integrator installations Only. 2. The OEM integrator is responsible for ensuring that the end-user has no manual instruction to remove or install module 3. Separate approval is required for all other operating configurations, including portable configurations with respect to Part 2.1093 and different antenna configurations 4. The authorized antennas per Part 15.204 (including antenna specification). COPYRIGHT ©2015 ALL RIGHTS RESERVED LANKE XUNTONG TECHNOLOGY CO.,LTD TEL: +86 755 26674742 +86 755 26675941 E-mail: nrf@freqchina.com Warning: om This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Please notice that if the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains FCC ID: 2AA72-DTR6818” any similar wording that expresses the same meaning may be used. na .c between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The module is limited to OEM installation ONLY. The OEM integrator is responsible for ensuring that the end-user has no manual instruction to remove or install module. ww w. fr qc hi The antenna must employ a ‘‘unique’’ antenna coupler as mentioned below form the module manufacturer (at all connections between the module and the antenna, including the cable). COPYRIGHT ©2015 ALL RIGHTS RESERVED LANKE XUNTONG TECHNOLOGY CO.,LTD TEL: +86 755 26674742 +86 755 26675941 E-mail: nrf@freqchina.com Important Notice: Reserves the right to make corrections, modifications, and/or improvements to the product and/or its specifications at any time without notice. Assumes no liability for the user’s product and/or applications. Products are not authorized for use in safety-critical applications, including but not limited to life-support applications. om ATTENTION! ww w. fr qc hi na .c Electrostatic Sensitive Device Observe Precaution for handling. COPYRIGHT ©2015 ALL RIGHTS RESERVED LANKE XUNTONG TECHNOLOGY CO.,LTD TEL: +86 755 26674742 +86 755 26675941 E-mail: nrf@freqchina.com 10
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Administrator Create Date : 2016:01:11 08:57:05+08:00 Modify Date : 2016:01:11 08:57:05+08:00 Title : Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2016:01:11 08:57:05+08:00 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Creator : Administrator Document ID : uuid:5fe20c1a-0cf2-4aad-ac64-6c585871ec87 Instance ID : uuid:c0be7cfb-9f7a-4a3a-92bd-a17a53934b32 Producer : Acrobat Distiller 9.0.0 (Windows) Page Count : 9EXIF Metadata provided by EXIF.tools