USER MANUAL
TWINDRIVE ®
TD4 Advanced
To learn more about LINAK, please visit:
www.linak.com
Page 1 of 28
Page 2 of 28
Contents
Preface.................................................................................................................................................. 4
Important information....................................................................................................................... 5
Safety instructions..............................................................................................................................
Safety issues....................................................................................................................................
Before installation, reinstallation or troubleshooting.........................................................................
Before start-up................................................................................................................................
During operation..............................................................................................................................
Misc................................................................................................................................................
Only for EU markets............................................................................................................................ 10
Only for Non EU markets................................................................................................................... 10
Misuse ................................................................................................................................................. 10
Informations importantes.................................................................................................................. 11
Consignes de sécurité.........................................................................................................................
Avant l´installation, ré-installation ou le dépannage..........................................................................
Avant de démarage..........................................................................................................................
Pendant le fonctionnement..............................................................................................................
Divers..............................................................................................................................................
11
12
12
12
12
Seulement pour les marchés au sein de l´UE................................................................................... 13
Seulement pour les marchés hors UE............................................................................................... 13
Utilisation abusive.............................................................................................................................. 13
Repairs.................................................................................................................................................. 14
Misc. on the TWINDRIVE® TD4 Advanced system............................................................................ 15
Description of the TWINDRIVE® TD4 Advanced system.................................................................. 15
Mounting instructions for the TWINDRIVE® system....................................................................... 16
TD4 Advanced - Start-up (How to pair Bluetooth connection).....................................................
1. Pairing your control......................................................................................................................
2. Pairing your smartphone or tablet.................................................................................................
3. Pairing another device later..........................................................................................................
Mechanical emergency lowering.......................................................................................................
Electrical emergency lowering..........................................................................................................
Cable strain relief.............................................................................................................................
17
17
18
19
20
21
21
Functional description........................................................................................................................ 22
Labels ................................................................................................................................................. 23
Disposal of LINAK products............................................................................................................... 24
Main groups of disposal..................................................................................................................... 25
Disposal of batteries.......................................................................................................................... 25
Drawing appendix............................................................................................................................... 26
LINAK application policy.................................................................................................................... 26
Addresses............................................................................................................................................. 28
Page 3 of 28
Preface
Dear User,
We are delighted that you have chosen a product from LINAK®.
LINAK systems are high-tech products based on many years of experience in the manufacture and development of
actuators, electric control boxes, controls and chargers.
This User Manual does not address the end-user. It is intended as a source of information for the manufacturer
of the equipment or system only, and it will tell you how to install, use and maintain your LINAK electronics. It
is the responsibility of the manufacturer of the end-use product to provide a User Manual where relevant safety
information from this manual is passed on to the end-user.
We are sure that your LINAK product/system will give you many years of problem-free operation.
Before our products leave the factory they undergo full function and quality testing. Should you nevertheless
experience problems with your LINAK product/system, you are always welcome to contact your local dealer.
LINAK subsidiaries and some distributors situated all over the world have authorised service centres, which are
always ready to help you.
LINAK provides a warranty on all its products. This warranty, however, is subject to correct use in accordance with
the specifications, maintenance being done correctly and any repairs being carried out at a service centre, which is
authorised to repair LINAK products.
Changes in installation and use of LINAK products/systems can affect their operation and durability. The products
are not to be opened by unauthorised personnel.
The User Manual has been written based on our present technical knowledge. We are constantly working on
updating the information and we therefore reserve the right to carry out technical modifications.
LINAK A/S
Page 4 of 28
Important information
Important information on LINAK® products can be found under the following
headings:
Warning!
Failure to comply with these instructions may result in accidents involving
serious personal injury.
Failing to follow these instructions can result in the product being damaged
or being destroyed.
Safety instruction
General
Safe use of the system is possible only when the operating instructions are read
completely and the instructions contained are strictly observed.
Failure to comply with instructions marked with the ”NOTE” symbol may result in
serious damage to the system or one of its components.
It is important for everyone who is to connect, install, or use the systems to
have the necessary information and access to this User Manual. Follow the
instructions for mounting – risk of injury if these instructions are not followed.
The appliance is not intended for use by young children or infirm persons
without supervision.
If there is visible damage on the product it must not be installed.
Note that during construction of applications, in which the actuator is to be
fitted, there must be no possibility of personal injury, for example squeezing
of fingers or arms.
Assure free space for movement of the application in both directions to avoid
blockade.
Only the power supply type SMPS001, SMPS002 or SMPS006, shall be used
with the system (TD4 Advanced).
The power supply shall not be covered while operating to allow sufficient
cooling of this appliance.
Page 5 of 28
Furthermore take care about the connecting wires from the power supply to
the TD4 Advanced, don’t damage this by overrun.
Assure free space for movement of application in both directions to avoid
blockade.
The appliance is only to be used with the power supply unit provided with the
appliance.
Safety issues
The builder of the equipment shall ensure that the use of the component
complies with relevant standards – like the Machine Directive. Care must be
taken to avoid squeezing of cables as it can cause movement of the system!
The SMPS001/002/006 must not be packed in heat insulating material, but
must be placed so that it can emit waste heat to the surroundings. There are
no ventilation holes to consider, the SMPS emits heat through its surface.
Only the power supply type SMPS001, SMPS002 or SMPS006, shall be used
with the system (TD4 Advanced).
It is possible only to use 1 power supply (SMPS001, SMPS002 or SMPS006)
for 2 TD4 systems. Remember speed may decrease when running 2 systems at
the same time.
Page 6 of 28
This device complies with part 15 of the
FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful
interference, and
(2) This device must accept any
interference received, including
interference that may cause
undesired operation
• Statement – for all intentional and unintentional radiators:
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
• Statement for digital devices for Class B:
NOTE: This equipment has been tested and found to comply with the limits for
a Class B diwgital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions it may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
Page 7 of 28
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux
appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes :
(1) l’appareil nedoit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en compromettre le fonctionnement.
Labeling Requirements:
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Page 8 of 28
Before installation, de-installation or troubleshooting:
• Stop the TD4 Advanced.
• Disconnect the power supply.
• Relieve the TD4 of any loads, which may be released during the work.
Before start-up:
• Make sure that the system has been installed as instructed in this User Manual.
• Make sure that the voltage is correct before the system is connected to the mains.
(See TD4 label in the appendix).
• System connection. The individual parts must be connected before connecting to
the mains.
During operation
• If the control box makes unusual noise or smells, switch off the mains voltage
immediately.
• Take care that the cables are not damaged.
• Unplug the mains cable on mobile equipment before it is moved.
Misc:
The actuator system has a sound level below 55dB(A) in typical applications.
Updated manuals and declarations can always be found here:
www.linak.com/HOMELINE
Electromagnetic fields (EMF):
This LINAK appliance complies will all standards regarding electromagnetic fields (EMF). If handled properly and according to
instructions in this user manual, the appliance is safe to use based on scientific evidence available today.
Page 9 of 28
Only for EU markets
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
Only for Non EU markets
Persons who do not have the necessary experience or knowledge of the
product/products must not use the product/products. Besides, persons with
reduced physical, sensory or mental abilities must not use the product/
products, unless they are under surveillance or they have been thoroughly
instructed in the use of the apparatus by a person who is responsible for the
safety of these persons.
Moreover, children must be under surveillance to ensure that they do not
play with the product.
Misuse
Do not overload the actuators – this can cause danger of personal injury and
damage to the system.
Do not use the actuator system for lifting persons. Do not sit or stand on a
table while operating – risk of personal injury.
Do not use the system in environments other than the intended indoor use
Page 10 of 28
Informations importantes
Les informations importantes sur les produits LINAK® peuvent être trouvées dans
les rubriques suivantes:
Attention!
Le non respect de ces instructions peut entraîner des accidents impliquant
des blessures graves.
Ne pas suivre ces instructions peut entraîner l´endommagement ou
destruction du produit.
Consignes de sécurité
Géneral
Le non respect de ces instructions peut entraîner des accidents impliquant des
blessures graves.
Ne pas suivre ces instructions peut entraîner l´endommagement ou destruction du
produit.
L´utilisation en toute sécurité du système n´est possible que si l´intégralité des
instructions ont été lues et ont été strictement suivies.
Le non respect de se conformer aux instructions marquées du symbole “note”
peut entraîner de graves dommages au système ou à un de ses composants.
Il est important pour tout individu qui connecte, installe, ou utilise le système
d´avoir les informations nécessaires et l´accès à ce mannuel d´utilisation.
Suivez les instructions pour le montage – risque de blessure si ces instructions
ne sont pas suivies.
L´appareil n´est pas destiné à être utilisé par des enfants ou des personnes
handicapées sans surveillance.
S´il y a des dommages visibles sur le produit, l´installation ne doit pas être
effectuée.
Prendre en compte lors de la construction du matériel, dans lequel l´actionneur
est incorporé, qu´il ne doit y avoir aucune possibilité de blessures corporelles,
telles que la compression des doigts ou des bras.
Assurez un espace libre autours du materiel pour éviter tout blocage.
Page 11 of 28
Avant l´installation, ré-installation ou le dépannage:
• Arrêtez TD4 Advanced
• Retirez la prise du secteur
• Soulagez TD4 Advanced des toutes charges qui pourraient être émises lors de
l´utilisation
Avant de démarage:
• Assurez-vous que le système a été installalé comme indiqué dans le mannuel
d´utilisateur.
• Assurez-vous que la tension du boîtier de contrôle est correcte avant que le
système soit connecté sur le secteur.
• Système de connection. Les différentes pièces doivent être connectées entre elles
avant que le boîtier de contrôle soit connecté au secteur. Consultez le manuel
d´utilisation si nécessaire.
Pendant le fonctionnement:
• Si le boîtier de contrôle émet un bruit ou odeurs inhabituelles, éteignez la tension
immédiatement.
• Veuillez à ce que les cables ne soient pas endommagés.
• Débranchez le cable d´alimentation sur l´équipement mobile avant qu´il ne soit
déplacé.
• Les produits ne doivent-être utilisés que dans un environement qui correspond à
leur IP.
Divers:
Le système d´actionneur présente un niveau sonore inférieur à 55dB (A) dans des
applications typiques.
Les mises à jours des manuels et autres informations peuvent-être trouvées sur
www.linak.com/homeline
Electromagnetic fields (EMF):
This LINAK appliance complies will all standards regarding electromagnetic fields (EMF). If handled properly and according to
instructions in this user manual, the appliance is safe to use based on scientific evidence available today.
Page 12 of 28
Seulement pour les marchés au sein de l´UE:
Cet appareil peut-être utilisé par des enfants âgés de 8 ans et plus, ainsi
que les personnes dont les capacités physiques, sensorielles ou mentales
sont réduites ou ayant un manque d´expérience et de connaissance si elles
ont bénéficié d´une surveillance ou d´instructions concernant l´utilisation de
l´appareil en toute sécurité et compris les risques encourus.
Les enfants ne doivent pas jouer avec l´appareil. Le nettoyage et l´entretien ne
doivent pas être rèalisés par des enfants sans surveillance.
Seulement pour les marchés hors UE.
Les personnes qui n´ont pas l´expérience ou les connaissances nécessaires
sur le ou les produit(s) ne doivent pas le ou les utiliser. Par ailleurs, les
personnes ayant des capacités physiques, sensorielles ou mentales réduites
ne doivent pas utiliser le ou les produit(s), sauf si elles sont sous surveillance
ou ont suivi une formation approfondie de l´utilisation de l´appareil par
l´individu responsable de la securité de ces personnes.
De plus, les enfants doivent-être sous surveillance afin de s´assurer qu´ils ne
jouent pas avec le produit.
Utilisation abusive:
Ne surchargez pas les actionneurs – cela peut engendrer un risque de
blessures corporelles et endommager le système.
Ne pas utiliser les actionneurs pour soulever des personnes. Ne pas s´asseoir
ou se tenir debout sur une table en fonctionnement – risque de blessures.
Ne pas utiliser le système dans dans des environnements autres que
l´utilisation intérieure prévue.
Page 13 of 28
Repairs
In order to avoid the risk of malfunction, all TWINDRIVE® repairs must only be carried out by authorised LINAK workshops or
repairers, as special tools must be used and special gaskets must be fitted. TWINDRIVE under warranty must also be returned
to authorised LINAK workshops.
Page 14 of 28
Misc. on the TWINDRIVE® TD4 Advanced system
This system is a TWINDRIVE system developed for leisure beds and for indoor use in private homes.
Warranty
There is 36 months’ warranty on the TWINDRIVE® products against manufacturing faults calculated from the production
date of the individual products (see label). LINAK A/S’ warranty is only valid in so far as the equipment has been used and
maintained correctly and has not been tampered with. Furthermore, the system must not be exposed to violent treatment. In
the event of this, the warranty will be ineffective/invalid. For further details, please see standard terms of sale and delivery for
LINAK A/S.
Maintenance
Clean dust and dirt on the outside of the system at appropriate intervals and inspect them for damage and breaks.
Inspect the connections, cables and plugs and check for correct functioning as well as fixing points.
The cleaners and disinfectants must not be highly alkaline or acidic
(pH value 6-8).
It is not allowed to use solvents for cleaning up.
Max. load running back and leg end motors at the same time in upward direction is
280 Nm on back motor, and 200 Nm on leg end motor.
For customers in the US/Canada:
The mains cable for this product has a polarised plug (one blade is wider than the other). It will only fit in a polarised
outlet one way. If it does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician
to install a proper outlet. Do not change the plug in any way.
Description of the TWINDRIVE® TD4 Advanced system
Each TWINDRIVE® TD4 Advanced unit consists of 2 internal motors and a built-in control box, which makes it a very
compact unit. The mains cable is exchangeable. Only the handset must be paired.
Application of the TWINDRIVE® TD4 Advanced system:
Irrespective of the load the Duty cycle: 10% ~ max. 1 min. at continous use followed by 9 min. not in use.
Do not turn on the system if it is not mounted in a bed.
TD4 is a Bluetooth® based system, which means you can use hand controls based on Bluetooth®.
LINAK® offers a range of compatible hand controls: HC05BL, HC10BL, HC20BL and HB10BL. Alternatively an App can be
downloaded to use a smartphone as handset.
You can pair four hand controls to one TD4. You can also pair both hand controls and app controls to the same TD4
Advanced, but only 4 controls in total. If you pair more hand controls than the TD4 Advanced can manage, the first paired
hand control will be forgotten.
This user manual will give you a detailed description on how to pair your hand controls with your TD4 Advanced.
Page 15 of 28
Mounting instructions for the TWINDRIVE® system:
Mounting is made by pushing the TD4 unit into the bed bracket and thereafter slide the closing devices on. It is IMPORTANT to
be completely sure that the closing devices are in place before using the TD4.
Do not drive the TD4 Advanced system without the closing devices mounted
The bed brackets must have a smooth surface without burs and welding blops in the area where the TD4 Advanced is
mounted.
Push the TD4 Advanced unit into the bed bracket
Lead the closing device in place			
Page 16 of 28
3 Press the closing device in final position
TD4 Advanced - Start-up (How to pair Bluetooth connection)
It is possible to pair multiple devices to the TD4 via Bluetooth®. See following instructions:
1. Pairing your control
Connect the TD4 to the mains via the connection cable. Now the TD4 will be in pairing mode in 3 minutes and the
Under Bed Light will blink to indicate this.
Take you hand control and press the Back “Up” and “Down” buttons at the same time. Now the light will blink a
little bit longer to indicate that the control and the TD4 paired up. The TD4 will stay in pairing mode and it is possible
to connect more controls using the same procedure as above. Be aware; you have to wait 5 seconds after pairing
control 1 until you can pair control number 2. To get the system out of pairing mode – simply press any button on an
already paired device.
When you operate the TD4 with the two controls you need to wait 5 seconds from operating with control 1 until you
can operate control 2.
Page 17 of 28
2. Pairing your smartphone or tablet
Connect the TD4 to the mains via the connection cable. Now the TD4 will be in pairing mode in 3 minutes and the
Under Bed Light will blink to indicate this.
Enable Bluetooth® on your smartphone/tablet. Open the TD4 app and a “search bed” page will be displayed. A list
of previously connected Twindrives and Twindrives in pairing mode will appear. Find the TD4 you wish to connect
on the list and tap to connect. The smartphone/tablet and the TD4 are now paired up and the app will display the
operation page.
Page 18 of 28
3. Pairing another device later
If you wish to connect another control or a smartphone/tablet to the TD4 later, just disconnect, wait 2 minutes and
connect the TD4 to the mains to get it in pairing mode again. See instructions 1 or 2 above to find out how to pair
the device, you want.
The TD4 will be in pairing mode every time the system has been out of power and connects again. To get the system
out of pairing mode – simply press any button on an already paired device.
If you wanted to pair a device, but did not make it in the 3 minutes pairing mode, please disconnect the TD4 from the
mains. Connect the TD4 to the mains again – now the TD4 will be in pairing mode for 3 minutes.
Page 19 of 28
Mechanical emergency lowering
Emergency lowering is meant for lowering the bed if a power failure occurs and the bed needs to be driven down into
horizontal position.
Disconnect the TD4 from the mains. Take the hex key on the side of the TD4. Underneath the TD4 are two gaps for
mechanical lowering – simply place the hex key in the gap, one end at a time, and turn the hex key in the direction
the arrow indicates.
It is important to turn the key in the direction indicated on the housing. Turning the key in the wrong direction can
wreck the inner hex and make mechanical emergency lowering impossible.
Do not use an electric screwdriver for lowering, use the enclosed hex key on the TD4.
Page 20 of 28
Electrical emergency lowering
Connection of emergency lowering:
1. Remove the SMPS from the mains.
2. Notice! If a locking device is mounted on the SMPS remove it now.
3. Unplug the connection cable from the SMPS
4. Connect the connection cable to the battery box for emergency lowering.
Cable strain relief
It is important to use the cable relief on the TD4. By using the relief you avoid that the connection cable plug is pulled
out of the TD4 resulting in a malfunction.
Page 21 of 28
Functional description
Hand Control HB10BL:
Up – down back motor
Up – down leg motor
Common operation up/down (option)
Light Button
Hand Control HC05BL:
Up – down back motor
Up – down leg motor
Common operation up/down (option)
Light Button
Hand Control HC10BL:
Up – down back motor
Up – down leg motor
Common operation up/down (option)
Light Button
Hand Control HC20BL:
Up – down back motor
Up – down leg motor
up to 3 extra channels
Common operation up/down (option)
Memory positions (3 positions)
Store Button
Light Button
Torch - Light Button
Page 22 of 28
Label for TD4 Advanced
Label for HB10
Label for HC05
Label for HC10
Label for HC20
Page 23 of 28
Disposal of LINAK products
As LINAK customers often ask us how our products can be disposed of or scrapped we have prepared this guidance that
enables a classification to different waste fractions for recycling or combustion.
Guidance
We recommend to disassemble our product into as many fractions as possible at the disposal and try to make it recycable. As
examples of main groups within waste fractions we can mention:
Metal, plastic, cable shoe, combustible waste and collection for recovery.
Some of these main groups can be subdivided, e.g. metal can be divided into iron, stainless steel and aluminium and alloy
steel. Plastic can e.g. be divided into ABS, PA, PE and PP.
As an example of sorting, please find below a list stating in which recycling groups the different components of LINAK
products ought to be placed:
Product
Components
Recycling group
Actuator:
Spindle and motor
Plastic housing
Cable
Scrap
Plastic recycling or combustion
Cable scrap or combustion
Massage motor:
Plastic housing
Cable
Plastic recycling or combustion
Cable scrap or combustion
TWINDRIVE:
PCB
Plastic housing
Cable
Transformer Scrap
Batteries
Spindle and motor
Electronics scrap
Plastic recycling or combustion
Cable scrap
Plasic housing
PCB
Batteries
Plastic recycling or combustion
Electronics scrap
Recovery
Handset/Control:
Recovery
Scrap
By now almost all our casted plastic parts are supplied with an interior code for plastic type and fibre contents, if any.
Page 24 of 28
Main groups of disposal
Product main
groups
TD4
Scrap
Cable
scrap
Electronics
scrap
Plastic recycling
or combustin
HB10BL
HC05
HC10BL
HC20BL
Comments
Disposal of batteries
Details regarding safe disposal of used and leaking batteries:
Batteries should be disposed in accordance with appropriate federal, state and local regulations. LINAK recommends that used
or leaking batteries are disposed through the local recycling system. Please do not throw used or leaking batteries in normal
household waste or in nature. This will cause damage to the enviroment.
How to deal with leaking batteries
Leaking batteries should be disposed as described above.
If leaking batteries are discovered in the product the batteries must be removed at once to minimise damage to the product. If
leaking batteries are left in the product, it may become defective.
It is recommended to use plastic gloves when handling leaking batteries. The contents of leaking batteries can cause chemical
burns and respiratory irritation.
If exposed to the contents of a leaking battery, please wash with soap and water. If irritation persists, please seek medical
attention. In case of eye contact, please flush eyes thoroughly with water for 15 minutes and seek medical attention.
LINAK APPLICATION POLICY
The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as
hardware, software, technical advice, etc. related to an existing or a new customer application.
LINAK products as defined above are applicable for a wide range of applications within the Medical, Furniture, Desk, and
Industry areas. Yet, LINAK cannot know all the conditions under which LINAK products will be installed, used, and operated, as
each individual application is unique.
The suitability and functionality of the LINAK product and its performance under varying conditions (application, vibration,
load, humidity, temperature, frequency, etc.) can only be verified by testing, and shall ultimately be the responsibility of the
LINAK customer using any LINAK product.
LINAK shall be responsible solely that the LINAK products comply with the specifications set out by LINAK and it shall be the
responsibility of the LINAK customer to ensure that the specific LINAK product can be used for the application in question.
Page 25 of 28
DRAWING APPENDIX
g No.: TD4_ADVANCED
TWINDRIVE® TD4 System Advanced
76
105
19
25.6
581 1
76
723
Page 26 of 28
HB10BL Hand Control
47
140
14
Drawing No.: HC05
HC05BL Hand Control
13.5
100
2.9
34
1.3
HC10BL Hand Control
HC20BL Hand Control
Page 27 of 28
FACTORIES
CHINA
LINAK (Shenzhen) Actuator Systems, Ltd.
Phone: +86 755 8610 6656
Fax:
+86 755 8610 6990
E-mail: sales@linak.cn
www.linak.cn
DENMARK
SLOVAKIA
LINAK A/S - Group Headquarters, Guderup
Phone: +45 73 15 15 15
Fax:
+45 74 45 80 48
Fax:
+45 73 15 16 13 (Sales)
E-mail: info@linak.com
www.linak.com
LINAK Slovakia s.r.o.
Phone: +421 51 75 63 414
Fax:
+421 51 75 63 410
E-mail: jp@linak.sk
www.linak.com
USA
LINAK U.S. Inc.
North and South American Headquarters
Phone: +1 502 253 5595
Fax:
+1 502 253 5596
E-mail: info@linak-us.com
www.linak-us.com
SUBSIDIARIES
DENMARK
ITALY
NORWAY
SWITZERLAND
LINAK Australia Pty. Ltd
Phone: +61 3 8796 9777
Fax:
+61 3 8796 9778
E-mail: sales@linak.com.au
www.linak.com.au
LINAK Danmark A/S
Phone: +45 86 80 36 11
Fax:
+45 86 82 90 51
E-mail: linak@linak-silkeborg.dk
www.linak.dk
LINAK Italia S.r.l.
Phone: +39 02 48 46 33 66
Fax:
+39 02 48 46 82 52
E-mail: info@linak.it
www.linak.it
LINAK Norge AS
Phone: +47 32 82 90 90
Fax:
+47 32 82 90 98
E-mail: info@linak.no
www.linak.no
LINAK AG
Phone: +41 43 388 31 88
Fax:
+41 43 388 31 87
E-mail: info@linak.ch
www.linak.ch
AUSTRIA
FINLAND
JAPAN
POLAND
TAIWAN
LINAK Repräsentanz
Österreich (Wien)
Phone: +43 (1) 890 7446
Fax:
+43 (1) 890 744615
E-mail: info@linak.de
www.linak.at
LINAK OY
Phone: +358 10 841 8700
Fax:
+358 10 841 8729
E-mail: linak@linak.fi
www.linak.fi
LINAK K.K.
Phone: 81-45-533-0802
Fax:
81-45-533-0803
E-mail: linak@linak.jp
www.linak.jp
LINAK Polska
Phone: +48 (22) 500 28 74
Fax:
+48 (22) 500 28 75
E-mail: dkreh@linak.dk
www.linak.pl
BELGIUM & LUXEMBOURG
FRANCE
MALAYSIA
REPUBLIC OF KOREA
LINAK A/S Taiwan Representative Office
Phone: +886 2 27290068
Fax:
+886 2 27290096
Mobile: +886 989292100
E-mail: michael.chen@linak.com.tw
www.linak.com.tw
LINAK France E.U.R.L
Phone: +33 (0) 2 41 36 34 34
Fax:
+33 (0) 2 41 36 35 00
E-mail: linak@linak.fr
www.linak.fr
LINAK Actuators Sdn. Bhd.
Phone: +60 4 210 6500
Fax:
+60 4 226 8901
E-mail: info@linak-asia.com
www.linak.my
LINAK Korea Ltd.
Phone: +82-(0)2-6231-1515
Fax:
+82-(0)2-6231-1516
E-mail: scully@linak.kr
www.linak.kr
GERMANY
NETHERLANDS
RUSSIAN FEDERATION
LINAK GmbH
Phone: +49 6043 9655 0
Fax:
+49 6043 9655 60
E-mail: info@linak.de
www.linak.de
LINAK Actuator-Systems B.V.
Phone: +31 76 5 42 44 40
Fax:
+31 76 5 42 61 10
E-mail: info@linak.nl
www.linak.nl
000 LINAK
Phone: +7 495 280 14 26
Fax:
+7 495 687 14 26
E-mail: info@linak.ru
www.linak.ru
INDIA
NEW ZEALAND
SPAIN
LINAK A/S India Liaison Office
Phone: +91 120 4734613
Fax:
+91 120 4273708
E-mail: info@linak.in
www.linak.in
LINAK New Zealand Ltd.
Phone: +64 9580 2071
Fax:
+64 9580 2072
E-mail: nzsales@linak.com.au
www.linak.co.nz
LINAK Actuadores, S.L.u
Phone: +34 93 588 27 77
Fax:
+34 93 588 27 85
E-mail: esma@linak.es
www.linak.es
LINAK Do Brasil Comércio De Atuadores Ltda.
Phone: +55 (11) 2832 – 7070
Fax:
+55 (11) 2832 – 7060
E-mail: info@linak.com.br
www.linak.com.br
CANADA
LINAK Canada Inc.
Phone: +1 502 253 5595
Fax:
+1 416-255-7720
E-mail: info@linak.ca
www.linak-us.com
LINAK İth. İhr. San. ve Tic. A.Ş.
Phone: + 90 312 4726338
Fax:
+ 90 312 4726635
E-mail: info@linak.com.tr
www.linak.com.tr
UNITED KINGDOM
LINAK UK Limited
Phone: +44 (0)121 544 2211
Fax:
+44 (0)121 544 2552
E-mail: sales@linak.co.uk
www.linak.co.uk
IRELAND
SWEDEN
LINAK UK Limited - Ireland
Phone: +44 (0)121 544 2211
Fax:
+44 (0)121 544 2552
+44 (0)796 855 1606 (UK Mobile)
+35 387 634 6554 (Republic Of Ireland Mobile)
E-mail: sales@linak.co.uk
www.linak.co.uk
LINAK Scandinavia AB
Phone: +46 8 732 20 00
Fax:
+46 8 732 20 50
E-mail: info@linak.se
www.linak.se
ARGENTINA
COLOMBIA
IRAN
SOUTH AFRICA
Novotec Argentina SRL
Phone: 011-4303-8989/8900
Fax:
011-4032-0184
E-mail: info@novotecargentina.com
www.novotecargentina.com
MEM Ltda
Phone: +[57] (1) 334-7666
Fax:
+[57] (1) 282-1684
E-mail: servicioalcliente@memltda.com.co
www.memltda.com.co
Bod Inc.
Phone: +98 2188998635-6
Fax:
+98 2188954481
E-mail: info@bod.ir
www.bod.ir
Industrial Specialised Applications CC
Phone: +27 11 312 2292 or +27 11 2077600 (Switch Board)
Fax:
+27 11 315 6999
E-mail: gartht@isagroup.co.za
www.isaza.co.za
AUSTRALIA
INDIA
RUSSIAN FEDERATION
UNITED ARAB EMIRATES
Ballarat Industrial Supplies
www.ballind.com.au
Mechatronics Control Equipments India
Pvt Ltd
Phone: +91-44-28558484/85,
E-mail: bala@mechatronicscontrol.com
www.mechatronicscontrol.com
000 FAM
Phone: +7 812 3319333
Fax:
+7 812 3271454
E-mail: purchase@fam-drive.ru
www.fam-drive.ru
Mechatronics
Phone: +971 4 267 4311
Fax:
+971 4 267 4312
E-mail: mechtron@emirates.net.ae
www.mechatronics.ae
INDONESIA
SINGAPORE
Pt. Himalaya Everest Jaya
Phone: +6 221 544 8956/8965,
Fax:
+6 221 619 4658/1925
E-mail: hejplastic-div@centrin.net.id
www.hej.co.id
Servo Dynamics Pte. Ltd.
Phone: +65 6844 0288
Fax:
+65 6844 0070
E-mail: servodynamics@servo.com.sg
www.servo.com.sg
For contact details on other countries please visit www.linak.com or contact:
CZECH REPUBLIC
LINAK C&S S.R.O.
Phone: +420581741814
Fax:
+420581702452
E-mail: ponizil@linak.cz
www.linak.cz
DISTRIBUTORS
BL Shipways & Co
www.blshipway.com.au
Gas Strut Marine and Industrial
www.gasstrutmarine.com.au
Prime Motion & Control
www.primehyd.com.au
West Vic Industrial Supplies
www.westvicindustrial.com.au
Terms of use
The user is responsible for determining the suitability of LINAK products for specific application. LINAK takes great care in providing
accurate and up-to-date information on its products.
However, due to continuous development in order to improve its products, LINAK products are subject to frequent modifications and
changes without prior notice. Therefore, LINAK cannot guarantee the correct and actual status of said information on its products.
While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as mentioned above, guarantee the availability of
any particular product. Therefore, LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its
catalogues or other written material drawn up by LINAK.
All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof, please contact LINAK.
Page 28 of 28
LINAK INTERNATIONAL
Phone: +45 73 15 15 15
Fax:
+45 74 45 90 10
Fax:
+45 73 15 16 13 (Sales)
E-mail: info@linak.com
www.linak.com
LINAK A/S reserve the right to make technical alterations
BRAZIL
TURKEY
©
LINAK Actuator-Systems NV/SA
Phone: +32 (0)9 230 01 09
Fax:
+32 (0)9 230 88 80
E-mail: beinfo@linak.be
www.linak.be
Copyright LINAK 2016.01 MA-M9-02-631
AUSTRALIA

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c111 79.158366, 2015/09/25-01:12:00
Create Date                     : 2016:04:14 14:08:08+02:00
Modify Date                     : 2016:04:14 14:11:19+02:00
Metadata Date                   : 2016:04:14 14:11:19+02:00
Creator Tool                    : Adobe InDesign CC 2015 (Windows)
Version ID                      : 1
Instance ID                     : uuid:0aa010ed-67a8-483e-9219-f20048497489
Original Document ID            : adobe:docid:indd:da47af09-eebf-11de-aaf7-9f3ac035b9f6
Document ID                     : xmp.id:243fb384-abad-e243-bdb8-c0b3b21fffeb
Rendition Class                 : proof:pdf
Contributor Resources Document ID: uuid:d40e06db-d2be-4c86-96a2-d4577df41026
Derived From Instance ID        : xmp.iid:5884e513-658c-064a-b0e3-ba367616b7c7
Derived From Document ID        : xmp.did:86d8f2be-d284-4444-9b13-38d2cacef5f3
Derived From Original Document ID: adobe:docid:indd:da47af09-eebf-11de-aaf7-9f3ac035b9f6
Derived From Version ID         : 1
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Windows)
History Changed                 : /
History When                    : 2016:04:14 14:08:08+02:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 28
Creator                         : Adobe InDesign CC 2015 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XBE-HC10BL

Navigation menu