Activate & Pair
Activate Battery
1. Use a coin to rotate the battery cover to the “OPEN” position (g. 1).
2. Remove the plastic tab , then place the battery back in position (g.
2).
3. Replace the battery cover and then rotate to the “CLOSE” position.
(g.6). The Key Fob will start to scan for the network and the LED
will ash 3 times.
Pair & Register
1. Follow the instructions that came with your Touchstone Hub to add
the new Key Fob (CHK-001). During pairing mode, the status LED
will ash until the Key Fob is connected (g. 4).
Notes: A scan is performed every 5 seconds.
The LED ashes 3 times when each scan is initiated.
The Key Fob sleeps between scans to conserve battery.
If after 20 scans a network is not found, the sensor enters sleep mode
indenitely.
The Key Fob resumes scanning the next time a zone status change
occurs (fault, restore, tamper, tamper restore, test button pressed,
etc.). This allows user interaction to cause the sensor to resume
scanning.
Battery Replacement
1. Use a coin to rotate the battery cover to the “OPEN” position (g. 5).
2. Remove old battery and replace with CR2032 type battery (g. 6).
3. Replace the battery cover and then rotate to the “CLOSE” position.
(g. 7).
Factory Reset
1. While holding down any 2 buttons, install battery. LED should
illuminate.
2. Release buttons prior to the LED turning o. The LED will blink to
indicate that unit Has been restored to factory defaults.
Note: If more than one button is pressed and they are NOT released before
the LED turns o, the device will turn on as usual.
Panic Button Conguration
On boot with no buttons pressed, the LED lights for 2 seconds, then
either starts blinking indicating it is looking for a network or if it is
already paired, the LED just turns o and the panic conguration is not
changed.
• If the “arm stay” button is the only button pressed, panic is
congured to send a police panic.
• If the “arm away” button is the only button pressed, panic is
congured to send a re panic.
• If the “disarm” button is the only button pressed, panic is
congured to send a medical panic.
Checking System Status
1 Press to show the current status of the security system.
The LED ashes red once to indicate that it has contacted the
system, then:
• Lights green for 3 seconds if the system is disarmed
• Lights red for 3 seconds if the system is armed
• Lights orange for 3 seconds if the system is not ready to be
armed (for example, a door is open)
Arm Away
Press for about 2 seconds to arm the system in Arm Away mode (the
home is unoccupied).
The LED ashes red once to indicate that it has contacted the system,
then lights red for 1 second. The exit delay starts.
Arm Stay
Press for about 2 seconds to arm the system in Arm Stay mode (there
are still people on the premises).
The LED ashes red once to indicate that it has contacted the system,
then lights red for 1 second. The exit delay starts.
Disarming the System
Before entering the premises in armed state, press for about 2
seconds to disarm the system without entering the premises.
The LED ashes green once to indicate that it has contacted the system,
then lights green for 1 second indicating that the system is disarmed
Panic Button
Press and hold for 3 seconds to send an alarm to central monitoring,
the actual type of alarm, police, re, depends on how the panic button
is congured. The LED ashes orange to indicate that the alarm has
been sent.
Key Fob (CHK-001) User Guide
g. 4
g. 1 g. 2 g. 3
g. 5 g. 6 g. 7
LED indications
LED Status Description
Illuminated the LED is on
Blinking the LED should turn on for 300 mS and then
turn o for 300 m
O the LED is turned o
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which
can be determined by turning the equipment o and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
You are cautioned that changes or modications not expressly
approved by the party responsible for compliance could void your
authority to operate the equipment.
FCC RF Radiation Exposure Statement:
1. This Transmitter must not be co‐located or operating in
conjunction with any other antenna or transmitter.
2. This equipment complies with FCC RF radiation exposure limits set
forth for an uncontrolled environment. This equipment should be
installed and operated with a minimum distance of 20 centimeters
between the radiator and your body.
IC Statement
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept
any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible
d'en compromettre le fonctionnement.
Industry Canada - Class B
This digital apparatus does not exceed the Class B limits for radio noise
emissions from digital apparatus as set out in the interference-causing
equipment standard entitled “Digital Apparatus,” ICES-003 of Industry
Canada.
Cet appareil numérique respecte les limites de bruits radioélectriques
applicables aux appareils numériques de Classe B prescrites dans la
norme sur le matérial brouilleur: “Appareils Numériques,” NMB-003
édictée par l’Industrie.
Operation is subject to the following two conditions: (1) this device may
not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the
device.
L'opération est soumise aux deux conditions suivantes: (1) cet appareil
ne peut causer d'interférences, et (2) cet appareil doit accepter toute
interférence, y compris celles susceptibles de provoquer
fonctionnement du dispositif.
To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically
radiated power (e.i.r.p.) is not more than that permitted for successful
communication.
An de réduire les interférences radio potentielles pour les autres
utilisateurs, le type d'antenne et son gain doivent être choisie que la
puissance isotrope rayonnée équivalente (PIRE) est pas plus que celle
premise pour une communication réussie.
RF exposure warning: The equipment complies with RF exposure limits
set forth for an uncontrolled environment. The antenna(s) used for this
transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
Avertissement d'exposition RF: L'équipement est conforme aux limites
d'exposition aux RF établies pour un incontrôlés environnement.
L'antenne (s) utilisée pour ce transmetteur ne doit pas être co-localisés
ou fonctionner en conjonction avec toute autre antenne ou
transmetteur.
Avertissement d'exposition RF: 1. Cet emetteur ne doit pas n'etre
coimplante ou operation en meme temps qu'aucune autre antenne ou
emetteur. 2. Cet equipement est conforme aux limites d'exposition de
rayonnement de la FCC rf determinees pour un environnement non
controle. Cet equipement devrait etre installe et actionne avec une
distance minimum de 20 centimetres entre le radiateur et votre corps.
CAN ICES-3 (B)/NMB-3(B)