La Crosse Technology TX186 RF wireless remote sensor User Manual TCM FUNKGESTEUERTE TEMPERATURSTATION

La Crosse Technology Ltd. RF wireless remote sensor TCM FUNKGESTEUERTE TEMPERATURSTATION

Users Manual

Download: La Crosse Technology TX186 RF wireless remote sensor User Manual TCM FUNKGESTEUERTE TEMPERATURSTATION
Mirror Download [FCC.gov]La Crosse Technology TX186 RF wireless remote sensor User Manual TCM FUNKGESTEUERTE TEMPERATURSTATION
Document ID1534372
Application IDrhu42oL6jW32rVUvlyomzg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize3.43kB (42858 bits)
Date Submitted2011-09-01 00:00:00
Date Available2011-09-01 00:00:00
Creation Date2011-08-26 09:23:25
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2011-08-26 09:23:29
Document TitleTCM FUNKGESTEUERTE TEMPERATURSTATION
Document CreatorAcrobat PDFMaker 7.0 for Word
Document Author: ME8

WIRELESS THERMO-HYGROMETER SENSOR (W186-E)
Owner’s Manual
NAME AND FUNCTIONS OF BUTTONS:
Functions
Tx
Press to transmit RF signal to the receiver
C/F
Toggle degree C & F unit
Channel 1, 2, 3
Slide to select channel 1, 2 or 3
SETTING UP THE WIRELESS THERMO-HYGROMETER SENSOR
Loosen the screws on the battery door with a small screwdriver, insert 2 pieces of AAA batteries
according to the polarity indicated
Set Channel 1 for the first wireless sensor. Set channel 2 and channel 3 for the 2nd and 3rd sensor
Press [C/F] button to change the temperature unit displayed on the wireless sensor
Follow the operation in the users’ manual of the main unit (receiver) to enter the RF searching
mode. (You may also reset the main unit by removing and reinstalling main unit’s batteries in
order to enter the RF searching mode)
Press [TX] button to transmit RF signal to the main unit
When RF connection is established, the respective temperature reading of the selected channel
will appear on the main unit
Note: Make sure the transmission is within range and path is clear of obstacles and RF interferences.
Shorten the distance between the main unit & wireless sensor if RF connection cannot be established.
Then follow the above procedure to setup the sensor again.
LOW BATTERY INDICATION
Low battery indication is available on the wireless sensor. Replace the batteries and follow the setup
procedure in this instruction manual.
BATTERY DISPOSAL
Replace only with the same or equivalent type recommended by the manufacturer.
Please disposal of old, defective batteries in an environmentally friendly manner in accordance with
the relevant legislation.
SPECIFICATIONS
Temperature range
0℃ to 60℃(32 F to +140 F)
Humidity range
20% - 99% RH
Channel
max. 3 channels
Transmission frequency
434 MHz
Power
3VDC(2 x 1.5 VDC size AAA)
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
NOTE:
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV
INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER AUTHORITY TO
OPERATE THE EQUIPMENT.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Company                         : MKTG
Source Modified                 : D:20110826012310
Create Date                     : 2011:08:26 09:23:25+08:00
Creator Tool                    : Acrobat PDFMaker 7.0 for Word
Modify Date                     : 2011:08:26 09:23:29+08:00
Metadata Date                   : 2011:08:26 09:23:29+08:00
Document ID                     : uuid:0b2a9b52-650c-45d8-a0da-38112175d609
Instance ID                     : uuid:68cc5fe6-c5f0-4e18-b021-d1b31e476e67
Version ID                      : 5
Format                          : application/pdf
Title                           : TCM FUNKGESTEUERTE TEMPERATURSTATION
Creator                         : ME8
Subject                         : 
Headline                        : 
Page Count                      : 2
Page Layout                     : OneColumn
Author                          : ME8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OMOTX186

Navigation menu