Laerdal Medical AS 20430250 Link Box PLUS User Manual

Laerdal Medical AS Link Box PLUS Users Manual

Contents

Users Manual

SimPad PLUS
Link Box PLUS
Important Product Information
EN
www.laerdal.com
English
SimPad PLUS / Link Box PLUS - Regulatory Information English
SimPad PLUS / Link Box PLUS - Regulatory Information
2 3
Read these instructions thoroughly before
connecting the equipment to the power
source. Observe all warnings, precautions
and instructions on the SimPad PLUS,
in the User Guide and in this Important
Product Information booklet. Retain this
booklet for future reference.
These declarations also apply when using
the following manikins in conjunction with
SimPad PLUS system:
MegaCode Kelly Advanced
Megacode Kelly Basic ECG Only
Megacode Kid Advanced
Megacode Kid Basic ECG Only
Nursing Anne
Nursing Kid
Nursing Baby
Resusci Anne QCPR
Resusci Baby QCPR
Resusci Anne Simulator
Resusci Anne Advanced Skill Trainer
Premature Anne
SimMan ALS
Warnings and Cautions
A Warning states a condition, hazard, or
unsafe practice that can result in serious
personal injury or death.
A Caution states a condition, hazard, or
unsafe practice that can result in minor
personal injury or damage to the manikin.
Operating Conditions
Water and Moisture
Cautions
Do not operate the device under or near
water - for example near a bathtub,
kitchen sink, or laundry tub, in a wet
basement, near a swimming pool or in
other areas with high humidity.
Never install jacks for communication
cables in wet locations.
Do not operate the product with
wet hands.
Lightning
Never use this device, or connect/
disconnect communication cables or
power cables during lightning storms.
Dust
Do not operate the device in areas with
a high concentration of dust.
Cleaning and Maintenance
Cleaning
Unplug the device from communication
lines, mains power outlet or any power
source before cleaning or polishing.
Do not use liquid cleaners or aerosol
cleaners. Use a lint-free cloth lightly
moistened with water for cleaning the
exterior of the device.
Servicing
Refer all servicing to qualified
service personnel.
Warnings
Do not attempt to service the device
yourself. Opening or removing covers may
expose you to dangerous voltages or other
hazards, and will void the warranty.
WiFi Connections
Please ensure that your settings of the
device adhere to any regional restrictions
on the use of WiFi channels.
Accessories
Use only accessories specified by the
manufacturer, or sold with the apparatus.
The RJ-45 jack should not be used for
telephone line connection.
Internal Battery Pack in SimPad PLUS
Cautions
Use only the SimPad battery with
SimPad PLUS.
Do not expose to high temperatures, such
as in direct sunlight or in a car parked in
the sun.
Only charge SimPad PLUS using
the supplied battery charger or a
recommended charging device that can
charge the battery.
Dispose of used battery pack promptly
and according to local legislations.
Do not dispose of in water.
Warnings
Do not disassemble, crush, puncture, or
short external contacts and do not allow
metal objects to come into contact with
the battery terminals.
Do not try to repair the battery, it may
cause an explosion.
Do not incinerate or dispose of in re,
the battery may explode or release toxic
materials.
Risk of explosion if battery is replaced by
an incorrect type.
If the internal battery pack in
SimPad PLUS is mishandled, it can burst,
cause a re or even chemical burns.
Power Connection and
Hazardous Voltage
Cautions
Never attempt to open this product, or any
peripherals connected to it, if this action
requires a tool.
If any parts of the product have visual
damage, never attempt to connect main
power, or any other power source, before
consulting service personnel.
Route the power cord to avoid it being
walked on or pinched by items placed
upon or against it. Pay particular attention
to the plugs, receptacles and the point
where the cord exits from the device.
Do not tug the power cord.
Warnings
The product or its accessories may have a
hazardous voltage inside.
The product should always be powered
from an earthed power outlet.
If the provided plug does not t into your
outlet, consult an electrician.
English
SimPad PLUS / Link Box PLUS - Regulatory Information English
SimPad PLUS / Link Box PLUS - Regulatory Information
4 5
US
Federal Communications
Commission (FCC) Statement
This device complies with part 15 of the
FCC rules. Operation is subject to the
following two conditions:
(1) This device may not cause
harmful interference.
(2) This device must accept any interference
received, including interference that
may cause
undesired operation.
This equipment has been tested and found
to comply with the limits for a Class B
digital device, pursuant to Part 15 of the
FCC rules. These limits are designed to
provide reasonable protection against
harmful interference in a residential
installation. This equipment generates, uses,
and can radiate radio frequency energy
and, if not installed and used in accordance
with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that
interference will not occur in a particular
installation. If this equipment does cause
harmful interference to radio or television
reception, which can be determined by
turning the equipment off and on, the
user is encouraged to try to correct
the interference by one or more of the
following measures:
Reorient or relocate the receiving
antenna.
Increase the separation between the
equipment and receiver.
Consult the dealer or an experienced
radio/TV technician for help.
Connect the equipment into an outlet
on a circuit different from that to which
the receiver is connected.
SimPad PLUS
FCC ID : QHQ-20430150
Link Box PLUS
FCC ID : QHQ-20430250
Cautions
This transmitter must not be co-located
or operating in conjunction with any other
antenna or transmitter
Any changes or modications not expressly
approved by the party responsible for
compliance could void the user’s authority
to operate this equipment.
The use of shielded I/O cables is required
when connecting this equipment to any and all
optional peripheral or host devices. Failure to do
so may violate FCC rules.
For Portable Device Usage
(<20cm from body/Specific Absorption
Rate (SAR) needed))
Radiation Exposure Statement:
This device meets the government’s
requirements for exposure to radio waves.
This device is designed and manufactured
not to exceed the emission limits for
exposure to radio frequency (RF) energy set
by the FCC of the U.S. Government.
The exposure standard for wireless device
employs a unit of measurement known
as the Specific Absorption Rate, or SAR.
The SAR limit set by the FCC is 1.6W/kg.
Tests for SAR are conducted using standard
operating positions accepted by the FCC
with the device transmitting at its highest
certified power level in all tested frequency
bands.
For Country Code Selection Usage
(WLAN Devices)
Notes
The country code selection is for non-US
model only and is not available to all
US model. Per FCC regulation, all WiFi
product marketed in US must xed to US
operation channels only.
Changes or modications not covered
in this manual must be approved in
writing by the manufacturer’s Regulatory
Engineering Department. Changes or
modications made without written
approval may void the user’s authority to
operate this equipment
Canada
Industry Canada Rules
This device complies with Industry Canada
license-exempt RSS standard(s). Operation
is subject to the following two conditions:
(1) This device may not cause interference,
and
(2) This device must accept any
interference, including interference that
may cause undesired operation of the
device.
Le présent appareil est conforme aux CNR
d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de
brouillage, et
(2) l’utilisateur de l’appareil doit accepter
tout brouillage radioélectrique subi,
même si le brouillage est susceptible
d’en compromettre le fonctionnement.
Canadian ICES-003 Statement
This Class B digital apparatus complies with
Canadian ICES-003.
Cet appareil numérique de la classe B est
conforme à la norme NMB-003 du Canada.
(1) This equipment complies with IC RSS-102
radiation exposure limits set forth for an
uncontrolled environment.
(2) This device and its antenna(s) must not
be co-located or operating in conjunction
with any other antenna or transmitter, except
tested built-in radios
(1) Cet équipement est conforme aux limites
d’exposition aux rayonnements définies par la
norme IC RSS-102 pour un environnement
non contrôlé.
(2) Cet appareil et son ou ses antenne(s) ne
doivent pas être placés à proximité d’un autre
émetteur ou d’une autre antenne, exception
faites des radios intégrées qui ont été testées.
The County Code Selection feature is
disabled for products marketed in the US/
Canada.
La fonction de sélection du code de pays est
désactivée pour les produits distribués aux
États-Unis ou au Canada.
SimPad PLUS
IC ID: 20263-20430150
Link Box PLUS
IC ID: 20263-20430250
EU
Radio and Telecommunication
Terminal Equipment (R&TTE)
Directive
This product is in compliance with the
essential requirements and other relevant
provisions of EU Council directive 1999/5/EC.
English
SimPad PLUS / Link Box PLUS - Regulatory Information
6 7
English
SimPad PLUS / Link Box PLUS - Regulatory Information
Symbol Glossary
CE Mark
Li-Ion batteries should be
recycled.
Dispose of in accordance with
your country’s
recommendations
Australian Radiocommunica-
tions and EMC Compliance
Mark
UL Listed
FCC Declaration of
Conformity label
Korea Certification
Japanese MIC Certification
Chinese Compulsory
Certificate (CCC)
Japanese Voluntary Control
Council for Interference
by Information Technology
Equipment (VCCI)
This Class 2 radio apparatus
product employs a frequency
band that is not harmonised
throughout the European
Community. Restrictions on
the use of the apparatus may
exist in one or more member
states.
Serial number
Warning/Caution
IP Classification IP32
WEEE
This appliance is marked according to
the European directive 2012/19/EC on
Waste Electrical and Electronic Equipment
(WEEE).
By ensuring this product is disposed of
correctly, you will help prevent potential
negative consequences for the environment
and human health, which could otherwise be
caused by inappropriate waste handling of
this product.
The symbol on the product, or on the
documents accompanying the product,
indicates that this appliance may not be
treated as household waste. Instead it
shall be handed over to the applicable
collection point for the recycling of electrical
and electronic equipment. Disposal must
be carried out in accordance with local
environmental regulations for waste disposal.
For more detailed information about
treatment, recovery and recycling of this
product, please contact your local city office,
your household waste disposal service or
Laerdal representative.
Warranty
Refer to the Laerdal Global Warranty for
terms and conditions. For more information
visit www.laerdal.com.
SimPad PLUS Specifications
Operating temperature 0 °C to 35 °C (32 °F to 95 °F), Humidity 5 to 90% RH non-condensing
Storage temperature -20 °C to 60 °C (-4 °F to 140 °F)
Size 158 x 126 x 25 mm (6.22 x 4.96 x 0.98 in)
Operating Altitude 5000 m Maximum
Weight 450 g (1lb)
LCD display High Resolution Color LCD display, 5.7 in, 480 x 640 pixels
Battery type Li-Ion 3.7 V, capacity: 16 Wh
Battery time 3 - 4 hours continuous use with 50% display brightness
Battery charging DC input 12V 0.7A max. USB OTG input, 5V 500 mA max
Charging time 10 – 80%, approximately 50% / hour from DC input 80% - 100%, 1 hour
Communication WiFi 802.11 a/b/g/n 2.4G + 5GHz, Link Box PLUS
Only: MIMO Bluetooth v4.0
SimPad PLUS Connections
DC input 12V DC, 3.33 A minimum. (for power adapter*),
or 7.2V DC, 4.4A (for battery)
Ethernet RJ45 connector
USB USB on the go input/output
Audio 3.5 mm audio jack with TRRS input. Microphone on sleeve
(compatible with iPhone headset)
Link Box PLUS
Operating temperature 0 °C to 45 °C (32 °F to 113 °F),
Humidity 5 to 90% RH non-condensing
Size 140 x 90 x 30 mm (5.51 in x 3.54 in x 1.18 in)
Operating Altitude 3500 m Maximum
Weight 200 g (0.44 lb)
Communication WiFi 802.11 b/g (2.4 - 5.0 GHz) Bluetooth
Ethernet 10/100 MB
*This product is intended to be supplied by a Listed Power Adapter. Contact Laerdal for further
assistance with purchasing the power source.
English
SimPad PLUS / Link Box PLUS - Regulatory Information
8
Link Box PLUS Connections
DC input 12V DC, 3.33 A minimum. (for power adapter**),
or 7.2V DC, 4.4A (for battery)
Ethernet RJ45 connector
Future Connector for future use
Manikin Power and signals to manikin. Pulse, sounds etc
Battery #1 Connector for Laerdal Li-Ion Battery
Blood Pressure Cuff pressure input: 0 - 300 mm Hg
USB USB A input / output
Audio in 3.5 mm jack with TRS input. Line in or microphone level
Audio out 3.5 mm jack with TRS output. Line out level
Battery #2 Connector for Laerdal Li-Ion Battery
Li-Ion Battery
Battery type Li-Ion, 4 cells
Cell type LIC 18650-22PC
Voltage 7.2 V nominal
Capacity 4.4 Ah typical (32 Wh)
Size 98 x 78 x 28.1 mm (3.86” x 3.07” x 1.11”)
Weight 270 g (0.6 Ib) approximately
Battery Charging
Charging voltage input 9 - 15V DC, 1.6 A max
Charging method Constant Current + Constant Voltage
Constant current 1.33A typ.
Expected cycle life 700 cycles for ≥ 1400mAh (cell)
Charging time: 0 - 80%: 30% per hour
80% - 100%: 1 hour
Charging Indicator 1. The charging indicator is only active when there is a charging voltage present
2. Charging: Steady yellow light
3. Charged: Steady green light
**This product is intended to be used with a Listed Power Adapter or DC power source marked
“L.P.S.”. Contact Laerdal for further assistance with purchasing the power source.
For SimPad PLUS FCC ID: QHQ-20430150
Radiation Exposure Statement:
This device meets the government’s requirements for exposure to radio waves.
This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal
Communications Commission of the U.S. Government.
The exposure standard for wireless device employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the
FCC is 1.6W/kg.
*
Tests for SAR are conducted using standard operating positions accepted by the FCC with the device transmitting at its highest
certified power level in all tested frequency bands.
For Link Box PLUS FCC ID: QHQ-20430250
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and
operated with minimum distance 20cm between the radiator & your body.
--------------------------------------------------------------------------------------------------------------------------------------
For SimPad PLUS IC: 20263-20430150
Radiation Exposure Statement:
The product complies with the Canada portable RF exposure limit set forth for an uncontrolled environment and are safe for intended operation as
described in this manual. The further RF exposure reduction can be achieved if the product can be kept as far as possible from the user body or set the
device to lower output power if such function is available.
Déclaration d'exposition aux radiations:
Le produit est conforme aux limites d'exposition pour les appareils portables RF pour les Etats-Unis et le Canada établies pour un environnement non
contrôlé.
Le produit est sûr pour un fonctionnement tel que décrit dans ce manuel. La réduction aux expositions RF peut être augmentée si l'appareil peut être
conservé aussi loin que possible du corps de l'utilisateur ou que le dispositif est réglé sur la puissance de sortie la plus faible si une telle fonction est
disponible.
For Link Box PLUS IC: 20263-20430250
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated
with minimum distance 20cm between the radiator & your body.
Déclaration d'exposition aux radiations:
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être
installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
For SimPad PLUS IC: 20263-20430150
For Link Box PLUS IC: 20263-20430250
Caution :
1) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile
satellite systems;
2) the maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall comply with the e.i.r.p. limit; and
3) the maximum antenna gain permitted for devices in the band 5725-5825 MHz shall comply with the e.i.r.p. limits specified for point-to-point and
non point-to-point operation as appropriate.
4) the worst-case tilt angle(s) necessary to remain compliant with the e.i.r.p. elevation mask requirement set forth in Section 6.2.2(3) shall be clearly
indicated.
5) Users should also be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and
5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices.
Avertissement:
1) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de
brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux;
2) le gain maximal d’antenne permis pour les dispositifs utilisant les bandes 5250-5350 MHz
et 5470-5725 MHz doit se conformer à la limite de p.i.r.e.;
3) le gain maximal d’antenne permis (pour les dispositifs utilisant la bande 5725-5825 MHz) doit se conformer à la limite de p.i.r.e. spécifiée pour
l’exploitation point à point et non point à point, selon le cas.
4) les pires angles d’inclinaison nécessaires pour rester conforme à l’exigence de la p.i.r.e. applicable au masque d’élévation, et énoncée à la section 6.2.2
3), doivent être clairement indiqués.
5) De plus, les utilisateurs devraient aussi être avisés que les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux (c.-à-d.,
qu’ils ont la priorité) pour les bandes 5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages
aux dispositifs LAN-EL.
© 2016 Laerdal Medical AS. All rights reserved.
Manufacturer: Laerdal Medical AS
P.O. Box 377
Tanke Svilandsgate 30, 4002 Stavanger, Norway
T: (+47) 51 51 17 00
Printed in Norway
20-09823 Rev A
www.laerdal.com

Navigation menu