Landis Gyr Technology ER1R1S6 5252 Ampy Module User Manual 14 0210 Exhibit Cover

Landis+Gyr Technology, Inc. 5252 Ampy Module 14 0210 Exhibit Cover

Manual

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598Certification ExhibitFCC ID: R7PER1R1S6FCC Rule Part: 15.247ACS Project Number: 14-0210Manufacturer: Landis+Gyr Technology, Inc.Model: 5252 Comm ModuleManual
LANDIS+GYR CONFIDENTIAL INFORMATIONGridstream RFEnhanced Series IVAMPY 5252BEndpoint User GuidePublication: 98-1745 Rev AADraft 7.30.14
Limitation on Warranties and LiabilityInformation in this document is subject to change without notice. This manual or any part of it thereof may not be re-produced in any form unless permitted by contract or by written permission of Landis+Gyr.In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost prof-its) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised, knew, or should have known of the possibility of such damages.© 2014 Landis+Gyr, Inc. All Rights ReservedGridstream RF Enhanced Series IV AMPY 5252B Endpoint User GuidePublication: 98-1745 Rev AARevision HistoryModification Date Revision Description Author07/30/2014 AA Pending Kim Utesch© 2014 Landis+Gyr • All rights reserved.Draft 7.30.14
User Guide 98-1745 Rev AA 3Table of ContentsChapter 1:  Endpoint Overview   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5Enhanced Series IV AMPY 5252B Endpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Endpoint Usage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Required Software  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Features and Functions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Communicating via Meter to Endpoint Connection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Auto-Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Retrieving Data   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Demand Reset   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Time Synchronization  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Power Outage/Restoration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Supporting Passwords  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Downloading Firmware    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Encrypting Data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Configuration Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Theory of Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10FCC Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10FCC Class B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10RF Exposure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Chapter 2:  Command Center Deployment/Configuration   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13Deployment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Auto Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Endpoint Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14Meter Manufacturer Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Import Installation File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Import Information File CSV Format requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17Time Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   17Tracking and Deployment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Deployment Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18RF Installation Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19Endpoint Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Packet Definitions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Alarm Definitions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Meter Configuration Groups  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Add Meters to a Meter Configuration Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Chapter 3:  Using Endpoint Testing Manager (ETM)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  29How To Use ETM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29Access to Endpoint Test Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Setting Up Access to the Command Center Server  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Adding a New Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30Selecting an alternate existing server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Modify an existing server   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31Draft 7.30.14
Table of Contents Landis+Gyr4 98-1745 Rev AA User GuideDelete an existing server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31Add additional servers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31After Login: Setup Cautions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32Certificate Attributes   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32Request MAT Certificate  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33ETM Sign In   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34Using the Bar-code Scanner  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35Navigating the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36Configuring a New Gridstream IWR Radio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36Meter Shop Best Practices Use Case - Proper IWR Configuration . . . . . . . . . . . . . . . . . . . .  37Authentication Server Connection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38Connecting to a Collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38Connection Tab  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39Baud Rate Selection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40Connecting to an Endpoint  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41Head End Radio Tab  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42Device Test Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44High Speed (115200 bps) Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47Multiple Meter Test Mode  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48Enabling Multiple Meter Test Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  48Editing Multiple Meter Test Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  49Firmware Download Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50Battery End Point Firmware Download  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52Module Tab  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52Optical Lockout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53Reporting Tab  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54Demand Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55Enabling Demand Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  56Demand Reset Lockout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  56Performing a Demand Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  56Command Scheduler Tab   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57Event Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59Command Schedule  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Universal Event Log Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61Service Limiting Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Service Limiting Modes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Read Program  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Service Limiting options  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  64Create a Service Limiting Program  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65Send an existing Service Limiting Program to an Endpoint  . . . . . . . . . . . . . . . . . . . . . . . . .  66Groups Tab   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Chapter 4:  Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69Enhanced Series IV AMPY 5252B Specs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69Draft 7.30.14
User Guide 98-1745 Rev AA 51Endpoint OverviewEnhanced Series IV AMPY 5252B Endpoint Figure 1 - 1. Gridstream RF Enhanced Series IV AMPY 5252B Meter and ModuleEndpoint UsageThe Gridstream RF Enhanced Series IV AMPY 5252B endpoint will be used for commercial and industrial metering applications. The communication module requires professional installation by qualified personnel.Draft 7.30.14
Chapter 1 - Endpoint Overview Landis+Gyr6 98-1745 Rev AA User GuideRequired SoftwareTo work with the endpoint, you need one of the following software tools:•Command Center version 6.2 or later.•RadioShop version x.x or later.•Endpoint Testing Manager version x.x or later.LabelsThe endpoint includes the following label. Figure 1 - 2. Label Identification1. LAN ID: XXXXXXXXNOTE: The LAN ID is a unique identifier for each endpoint. It always displays in hex. Landis+Gyr provides the LAN address. You cannot change the LAN ID of a radio.2. Model: 5252 COMM Module3. Meter FCC ID: U3R-5252-01 TYPE - 5252B4. Module FCC ID: R7PER1R1S6Features and FunctionsUsing the AMPY 5252B Meter with the Gridstream RF Enhanced Communication Module, you can:•Integrate the endpoint into the 240V, Form 25 AMPY 5252B meter.•Communicate via serial connection between the endpoint and the meter through the meter's provided interface.•Support all levels of meter passwords.•Download radio firmware.Communicating via Meter to Endpoint ConnectionThe serial connection is a 26-pin header that contains:Draft 7.30.14
Landis+Gyr Chapter 1 - Endpoint OverviewUser Guide 98-1745 Rev AA 7•Full duplex serial connection. The baud rate is 9600, 8 bits, 1 stop bit, no hardware hand-shaking.•Power fail indication signal from the meter that tells the endpoint to disconnect from drawing power from the meter.•DC power line which supplies power to the module from the meter.Auto-RegistrationEndpoint firmware version 9.04 or later and module Device Control Word (DCW) x.xx or later is required for auto-registration. After the meter/endpoint is installed in the field it will automatically register with the Head End System. No special tools are needed during installation as the normal Utility meter swap process can be utilized. The meter automatically sends in the registration information containing items on how the meter/communication module is configured so the host can properly interpret the incoming data. Some of the items contained in this are as follows:•Default Gridstream RF Collector destination•Reporting interval for Register Data•Reporting interval for Interval Data•Meter's AMR-level security password•Time Synchronization parameters•GMT offset•Periodic Register Data reporting•Periodic LP Data reporting•Meter configuration informationOnce this information has been sent the meter/communication module starts collecting and sending based on the default configuration loaded during manufacturing.Retrieving DataThe communication module performs data retrieval from the meter on request (ORR) or autonomously (periodically reported). Availability of the following features depends on meter configuration. On Request Reads (ORR) available with this communication module are:•Register Data which includes consumption, demand and TOU values•Load Profile or Interval Data•Revenue Integrity Services which includes instantaneous measurements related to line voltage, current and phase angleAvailability of the following features depends on meter configuration. Options for periodically reported data with this module include:•Register Data & Status Flags which includes consumption, demand, TOU values and meter status.Draft 7.30.14
Chapter 1 - Endpoint Overview Landis+Gyr8 98-1745 Rev AA User Guide•Load Profile or Interval Data & Status Flags (Standard Tables 64 & 3) which includes interval data and meter status.Demand ResetWhen Command Center delivers a Demand Reset command, the communication module passes the command to the meter, which performs the Demand Reset on the meter. The meter/communication module then passes the previous demand data captured by the meter to Command Center for processing.Time SynchronizationTime synchronization is the process of keeping the meter time synchronized with the Gridstream RF network time within a configurable limit. The communication module automatically keeps its time synchronized with the Gridstream RF network via periodic background process. The communication module reads the meter date/clock table periodically, determined by its configuration. If the time drift between the meter and communication module exceeds the configured threshold, it sends a time synchronization alert message to Command Center. Command Center schedules a time change event for the meter and sends it to the communication module. The time of the change is determined such that the meter’s data integrity is maintained. At the scheduled time, the communication module executes the standard procedure to change date/time on the meter.Power Outage/RestorationWhen an outage occurs, the meter uses an early power failure signal to alert the communication module to disconnect from the meter's power immediately. The communication module saves critical module data to non-volatile memory and creates and sends a power outage message. This message includes the following information:•LAN ID•Outage time•Reboot count.The communication module sends the message, then assists with routing other packets until the back-up energy source can no longer keep the radio alive. The time that this energy source is available varies with several factors, including amount of data packets being routed, environmental conditions and age of meter/communication module. Generally, a hold-up time of ~120 seconds is typical. At restoration, the communication module first acquires network connectivity. With network communications restored, the communication module sends a power restoration message that includes details such as: •LAN ID•Outage time•Restoration time•Reboot count.The communications module stores a history of up to the last five power outage and restoration event pairs. Command Center can request this data.Draft 7.30.14
Landis+Gyr Chapter 1 - Endpoint OverviewUser Guide 98-1745 Rev AA 9Supporting PasswordsThe meter/communication module supports passwords provided by the utility. See publication 98-1055 Gridstream 2-way Endpoint Testing Manager User Guide for information regarding loading password into module.Downloading Firmware Communications module firmware can be upgraded via Command Center or ETM.Encrypting DataThe Gridstream RF Network currently supports use of one encryption key per network. If you enable the Gridstream RF Enhanced with encryption, Command Center must have a matching encryption key.Configuration TablesThe Gridstream RF Endpoint Configuration structure passes the data to configure the endpoint. It is used for both C&I and Residential applications.This table is currently 55 bytes long. It contains information necessary to configure several services on the endpoint, such as firmware reads, autonomous data return configuration.The endpoint receives the packet, and using the data, configures its own operation. The host maintains a record of the endpoint’s configuration.Item OtherPacket Contents Identifies which elements in this packet are set. Elements that are not set are ignored. There still must be a place in the packet for it, though.Config Byte 1 Not UsedConfig Byte 2 Not UsedConfig Byte 3 Not UsedConfig Byte 4 Not UsedConfig Byte 5 Not UsedReporting Interval LP In Minutes.Pump Period Register In Minutes.Pump Period RIS In minutes.  The period for the RIS/Vector/Voltage data pump.Pump Period Status In minutes.  The period for the Device Status (SO3, typically) data pumpPump Period Snap ReadSnap Reads will be delivered at a pseudo-random time, which will occur in the first X hours of each day. X is the value that is provided here. It will default to 2. The process is: this value, which is in hours, will be converted to minutes. The LAN ID will be mod-ed with this minute value, and the result will be the minute of the day that the self read is transmitted. User ID 2 byte User ID used while running ANSI Logon ServiceDraft 7.30.14
Chapter 1 - Endpoint Overview Landis+Gyr10 98-1745 Rev AA User GuideTheory of OperationThe Gridstream RF Enhanced Series IV AMPY 5252B module is an electric endpoint with 900MHz Gridstream communications on a single PCB. This product will be integrated into the Ampy 5252 meter. The following figure shows the high-level block diagram of the module. Each functional block is described in the following sections. Figure 1 - 3. Block DiagramFCC ComplianceFCC Class BThis device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: Logon User 10 byte User Name that is used while running the ANSI Logon ServiceSecurity Password The full 20 bytes are required.Sustained Outage DurationDefines the number of seconds after which an outage will be classified as sustained. If less than this amount, the outage is momentary. A value of zero will cause all outages to be considered "sustained". Max Meter Time Drift The number of seconds that the meter clock can drift from the radio clock, after which an alarm is triggered.Meter Time Read Period The number of seconds that the meter clock can drift from the radio clock, after which an alarm is triggered.GMT Offset The GMT Offset in 15 minute increments. Signed.Item OtherDraft 7.30.14
Landis+Gyr Chapter 1 - Endpoint OverviewUser Guide 98-1745 Rev AA 111. This device may not cause harmful interference, and2. This device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Consult Landis+Gyr or an experienced radio technician for helpUWARNING: Changes or modifications to this device not expressly approved by Landis+Gyr could void the user’s authority to operate the equipment.RF ExposureThis equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.Draft 7.30.14
Draft 7.30.14
User Guide 98-1745 Rev AA 132Command Center Deployment/ConfigurationDeploymentAuto RegistrationLandis+Gyr RF radio is Plug & Play; meters equipped with Landis+Gyr endpoints arrive from the factory in operational mode, ready to be installed at a service location. Along with the meters, a Meter Manufacturer File is provided to the utility. This file contains meter number/serial number combinations; the file must be uploaded into Command Center prior to installation of endpoints in the field.A meter installer installs the endpoint at the service location.Once installed, the endpoint will begin the following auto-registration process:1. The endpoint listens for RF traffic and evaluates its neighbors, searching for the best possible path to the collector. The best path is the one with the fewest hops to the Collector and through an endpoint with the highest Receive Signal Strength Indicator (RSSI) (RSSI is the receive signal strength from the node. It is a rough indicator of how strong the signal is from the radio).2. Having identified the best path, the endpoint will transmit the following two packets:• RF Registration Packet: The RF Registration Packet identifies for the Collector the return path to the endpoint. This is achieved by each intermediary endpoint adding its LAN address to the endpoint’s RF Registration Packet as it travels to the Collector. Once the RF Registration Packet is received, the endpoint will transition to Discovered in Command Center. The RF Registration will continue to be sent until the SetWAN command is received from Command Center.•Init Push: The Init Push packet contains configuration information about the meter, that allows Command Center to understand the configuration of the meter.   The Init Push is transmitted until the SetWAN command is received from Command Center.3. Once the RF Registration Packet and Init Push are received, Command Center will validate the configuration and, if validated, begin accepting readings from the endpoint. The endpoint will remain in Discovered status until the SetWAN command is received by the endpoint.4. The SetWAN command is issued to the endpoint when Command Center receives latitude and longitude information AND the endpoint’s closest neighbor has a WAN address. The SetWAN command provides the endpoint with its WAN address. The WAN address is the radio’s physical location (Latitude and Longitude) expressed in degree, minutes and seconds. The SetWAN command achieves two way communication with the endpoint. The SetWAN tells the endpoint that we have received your configuration information and it is OK to stop sending it in.Draft 7.30.14
Chapter 2 - Command Center Deployment/Configuration Landis+Gyr14 98-1745 Rev AA User GuideNOTE: If Installation Data is received before an Init Push has been received, the installation record will be stored awaiting the Init Push from the device.Endpoint StatusEndpoints will move from one status to another during the deployment process. The following are various endpoint statuses:•Installed. Endpoints in the Installed status have been deployed in the field, but Command Center has not received the RF Registration packet.• Discovered. Endpoints in the Discovered status have transmitted an RF Registration Packet. The RF Registration Packet identifies for the Collector the return path to the endpoint. This is achieved by each intermediary endpoint adding its LAN address to the endpoint’s RF Registration Packet as it travels to the Collector.•Normal. Endpoints in the Normal status have transmitted an Init Push packet containing configuration information AND have acknowledged a SetWAN command from Command Center. The SetWAN command provides the endpoint with its WAN address. The WAN address is the radio’s physical location (Latitude and Longitude) expressed in degree, minutes and seconds.•Lost. Endpoints in the Lost status have reported an outage event. When the endpoint loses power, it will transmit a “Power Outage Event” to Command Center. Once power has been restored, the endpoint transmits a “Power Restore Event”. The endpoint will then transition back to Normal status.• Configure. Endpoints in the Configure status are endpoints that have been recently added to a new configuration group and have not yet confirmed the receipt of configuration commands.• Failed. Endpoints and/or meters in the Failed status have failed a re-configuration attempt or have failed a work flow process. Work flow processing will determine if configuration changes such as time zone updates, reconfiguring of endpoints, meter change programs have been successful. Endpoints must be manually removed from the Failed status, generally by attempting the work process again.•Archive. Endpoints in Archive status are no longer in use within the Mesh System, for example, damaged endpoints. Endpoints must be manually entered into Archive status.•Inventory. Endpoints in Inventory status have not yet been deployed in the field. These may be recently purchased meters or meters that have been removed from the field and are awaiting redeployment.Meter Manufacturer DataThe Meter Manufacturer Data screen allows the user to import an XML or CSV file supplied by the meter manufacturer so the utility does not have to key in meters and endpoints by hand.1. Click Operations > Import > Meter Manufacturer Data to display the Import Meter Manufacturer Data screen.Draft 7.30.14
Landis+Gyr Chapter 2 - Command Center Deployment/ConfigurationUser Guide 98-1745 Rev AA 15 Figure 2 - 1. Import Meter Manufacturer Data2. Click the Browse button to navigate to, and select, a file that was sent by the meter manufacturer.3. Click the Save button to import the file into the database.The Meter Manufacturer Data Import (Upload Complete) window will appear displaying the Error Summary (if applicable) and Successful Entries. Figure 2 - 2. Upload Complete WindowNOTE: Any entries under Error Summary will be red text. The usual reason for an entry under Errors is that the endpoint already exists in the system. If file parsing errors or other file-related errors occur, contact the meter manufacturer that supplied the file.4. Successful entries will be added to inventory and will be displayed on the dashboard as Inventory status.Import Installation FileMeter deployment details can be imported by use of an Installation File provided by the installer. Following is the procedure for importing the installation file.1. Click Operations > Import > Import Installation File to display the Import Installation File screen.Draft 7.30.14
Chapter 2 - Command Center Deployment/Configuration Landis+Gyr16 98-1745 Rev AA User Guide Figure 2 - 3. Import Installation File Screen2. Enter the Path to the file....or...3. Click the Browse button to navigate to, and select, a file containing the endpoint information.4. Click OK to upload the file. The information imported via the Installation File:Table 2-1. Installation File Fields Data Format Format/DescriptionUser ID* AlphaNum (30) Login assigned by the utility for the installer. Utility may elect to use “1” for System usage.Installation Date*DateMM/DD/YYYY12/26/2009Actual date the meter was installed. This date is used in various Command Center reports to track deployment statistics.Installation Time* T i m e  H H M M  A M / P M           11:12 AMActual time the meter was installed. This date is used in various Command Center Reports to track deployment statistics.Change Out meter number AlphaNum (20)The meter being replaced with a new meter. Meter change out information is displayed in the notes section of the endpoint information screen. Change Out meter kWh AlphaNum (20)The kWh reading on the meter being replaced Meter change out kWh information is displayed in the notes section of the endpoint information screen. Variable Character.Installed Meter Number* AlphaNum (20)Meter number of the new meter being installed. This meter must exist in Command Center prior to importing the Import Installation File. Must parse to Decimal format.Installed Endpoint Serial Number* Decimal (9)The serial number of the new meter being installed. Note: Endpoint serial numbers must be converted from Hex to Decimal.Installed Meter kWh Decimal (9) Initial reading of the new meter.Service Latitude Decimal (12,8) GPS latitude.* Indicates a required field.Draft 7.30.14
Landis+Gyr Chapter 2 - Command Center Deployment/ConfigurationUser Guide 98-1745 Rev AA 17Import Information File CSV Format requirementsACAUTION: Required fields are UserID, Installed Date, InstalledTime, InstalledMeterNo, and InstalledEndpointSN. If these fields are not populated, the file will not be processed. Service Location is required if the Latitude and Longitude fields are populated. Command Center will ignore the latitude and longitude values if Service Location is not provided.The Import Installation File window provides a CSV template link. Click this link to view the format requirements for the file. This template can be saved to a network location or local machine and provided to the installer.The Installation file must be of the following format:•The first line must be a header.•A comma is required to separate each item even if no data exists.•A Service location is required if the service latitude and longitude are provided.Time ZoneIn order to report reading time correctly, the endpoint must be programmed with the appropriate time zone; this is achieved by sending commands to the endpoint that indicates the time zone in which the endpoint is installed and whether Daylight Savings Time (DST) is observed in the given time zone.The Installation File should include the endpoint time zone. Clicking the Time Zone List link will open a document that displays a list of valid time zone designations by country. Figure 2 - 4. Time ZonesService Longitude Decimal (12,8) GPS longitude.Service Location AlphaNum (100) Meter service location.Service Time Zone See formatting below.The service time zone may be entered to specify the correct time zone for the service location.Table 2-1. Installation File Fields (Continued)Data Format Format/Description* Indicates a required field.Draft 7.30.14
Chapter 2 - Command Center Deployment/Configuration Landis+Gyr18 98-1745 Rev AA User GuideTracking and DeploymentDeployment StatusDeployment Status enables users to monitor the find process when endpoints are being deployed on a system.1. Click Network > Deployment Status to display the Deployment Status Report screen. Figure 2 - 5. RF Deployment Status Screen2. Choose the Selection Criteria:A. All...or...B. Collector. Select the desired collector from the drop-down menu.3. Select a Date Range:A. Start Date. Click the calendar icon, and then click on the desired start date.B. End Date. Click the calendar icon and then click the desired end date.4. Click the OK button to display the RF Deployment Status Report. Figure 2 - 6. RF Deployment Status ReportThe RF Deployment Status Report displays a graph representing 14 days of installation statistics and a chart. Time periods longer than 14 days may be selected, but will not be presented on the graph due Draft 7.30.14
Landis+Gyr Chapter 2 - Command Center Deployment/ConfigurationUser Guide 98-1745 Rev AA 19to space limitations. By clicking on a specific date, each endpoint registering that day displays installation, registered, normal and reading status for this date. Information on the report is updated as the information is received by Command Center on a rolling seven day basis. Installation information is populated from the RF Installation File Import process. Registered and Normal status updates are based on receipt of the two registration requests from the endpoints. Readings are based on the first reading received from the endpoint. Average deployment time is based on the time it takes to go from installed to normal.5. Click on the Date link to display the Gridstream Meters Deployed By Day report. Figure 2 - 7. RF Meters Deployed by DayRF Installation StatusThe RF Installation Status Report is intended to be used by utilities during mass deployment. It can be used as an installation tool to determine how many meters have been installed over a specified time frame and of those meters how many have been discovered, how many have moved to normal status, how many are sending readings, and how many have sent readings in the past 24 hours.Following is the procedure for viewing the RF Installation Status report:1. From Command Center, select Network > RF Installation Status. The RF Installation Status window will open. Figure 2 - 8. RF Installation Status2. Selection Criteria. Select All to view results for all collectors in the system...or...Select the desired collector from the drop down box to view results for only that collector.3. Date Range. Enter a Start Date and End Date. Select the Calendar icon to view a calendar and make date selections if needed.4. Click OK. The RF Installation Status report will be displayed, shown in Figure 2 - 9.Draft 7.30.14
Chapter 2 - Command Center Deployment/Configuration Landis+Gyr20 98-1745 Rev AA User Guide Figure 2 - 9. RF Installation Status ReportThe following information is displayed in the report:•Day. This number will increment for each day the used has selected to display.•Date. This will display the dates selected in generation of the report. Click the date link to view a list of all meters deployed on the selected date.• Daily Installed. This will display the number of endpoints installed for that particular day. The daily installed data is imported into Command Center via the Installation File.• Discovered. Of the total number of meters installed on the summary date, the total number of those that have transitioned into a Discovered state and the percentage                      (Discovered meters/Installed meters).•Normal. Of the number of meters installed on the summary date, the total of those meters that have transitioned to a normal state at that point in time and the percentage (Normal meters/Installed meters).• Readings. Of the total number of meters installed on that day, the number of those meters that have sent in a billable reading packet, and the percentage (meters that have sent a billable reading packet/total meters installed on that day).• Readings past 24 Hours. Of the meters that were installed on that day, the total number of meters that sent in a billable readings packet in the last 24 hours (from the point the report was generated) and the percentage (meters that sent in a billable readings packet in the last 24 hours/total meters installed on that day).• Cumulative installed. The total number of meters that have been installed up to that date.•Normal. The total cumulative number of meters that have transitioned to Normal status up to that date.The color-coded bar graph displays the following deployment information:•Cumulative number of meters installed for each date (Grey).•Current number of meters that have transitioned to Normal status (Green).Draft 7.30.14
Landis+Gyr Chapter 2 - Command Center Deployment/ConfigurationUser Guide 98-1745 Rev AA 21•Number of installed meters that have sent in a billable reading in the last 24 hours (Blue).Endpoint ConfigurationPacket DefinitionsCreating a packet definition is necessary to reconfigure the packet payload of an endpoint. Packet definitions can contain several different user-configurable data elements.NOTE: RF endpoints allow a user to return up to 6 registers. However, the more registers returned, the greater the strain on the network.1. Click Setup > Packet Definitions > RF ResidentialThe Packet Definitions screen will be displayed. Figure 2 - 10. Packet Definitions Screen2. In the Packet Definitions screen click the New button to display the Packet Definition window.Draft 7.30.14
Chapter 2 - Command Center Deployment/Configuration Landis+Gyr22 98-1745 Rev AA User Guide Figure 2 - 11. The Packet Definition Window3. Enter a name in the Packet Name field. The name should be unique to the organization.4. Click the Edit Description link to enter any desired notes for the packet definition. If any notes were entered, click the OK button to save them.5. Select a Packet Type from the drop-down.•On Demand. Used for RF Endpoints.• Daily Packet Type. Used for PLC Endpoints6. Select the Meter Type from the drop-down.7. Select the desired data options from the Available Data Options window on the left side of the screen.To view a description of each available data option, click once on the data element. A description of the data element will be displayed in the yellow shaded box in the lower-center area of the screen.NOTE: The available data options vary depending on the type of endpoint.8. Click the right pointing arrow to move the data option to the Selected Data window.As you select data options, monitor the Packet Capacity gauge on the right of the screen. Each selection will add to the percentage total. If your selections exceed 100 percent, a message will be displayed when you click the Save button indicating that packet capacity must be 100% or less and can contain six or fewer data items. You can remove selections from the Selected Data window by clicking to highlight the selection and then click the left pointing arrow to remove the selection.9. After selecting all of the desired data options, click the Save button to save the new packet definition.Draft 7.30.14
Landis+Gyr Chapter 2 - Command Center Deployment/ConfigurationUser Guide 98-1745 Rev AA 23Alarm DefinitionsAlarm Definitions determine what type of response the given Events will trigger, including Dashboard Alerts and Email Alerts. Alarm Definitions must be created prior to Meter Configuration Groups in order to be programmed to a module.1. Click Setup > Alarm Definitions and select the appropriate endpoint type to display the Alarm Definitions screen. Figure 2 - 12. Alarm Definitions screen2. Click the New button to display the Alarm Definition screen. Figure 2 - 13. Alarm Definition screen3. Enter an Alarm Definition name in the Name field.4. Choose the desired setting for each event. See below for setting descriptions.NOTE: The default Alarm Definition settings represent the recommendation of Landis+Gyr.5. Click the Save button.An Alarm Definition can only be edited if it is not already part of an existing Configuration Group.Available SettingsResult Disabled Log Only Advisory AlarmEvent is:Logged in module Available via request Included in next  Transmitted immediately Flagged on Dashboard Included in E-mail Alerts Draft 7.30.14
Chapter 2 - Command Center Deployment/Configuration Landis+Gyr24 98-1745 Rev AA User GuideMeter Configuration GroupsA Configuration Group is a type of Command Addressing Group. A meter can be a member of only one configuration group. All members of a configuration group must be assigned the same configuration settings. Configuration groups are used to drive group-based reconfigurations for multiple endpoints.Each endpoint type is manufactured with a default configuration group.The data transmitted by an RF module, how frequently the data is sent, and how the module responds to conditions in the field, is dictated by the endpoint’s Configuration Group.An RF Endpoint configuration consists of the following:• Packet Definitions that are built for various data elements to be captured by the endpoint.• Alarm Definitions that establish the priority associated with events that occur in the RF endpoints.• RF Network Settings that establish the outage wait and time synchronization settings.•A schedule that includes the commands and packet definitions, along with time settings and frequency settings associated with data transmission, that are stored in the endpoint.NOTE: During the Auto-registration process, the module transmits an Init Push packet which indicates its configuration. This enables Command Center to associate the endpoint with the appropriate configuration group. If the configuration transmitted does not match an existing configuration in Command Center, a new configuration group may be auto-generated to which the endpoint will be assigned. For this process to occur, the Auto Generate Meter Configuration Groups setting must be enabled in System Settings.1. Click Setup > Groups > Meter Configuration Groups and select the endpoint type.The Configuration Group screen will be displayed. Figure 2 - 14. Configuration Groups WindowIf you wish to view the details of an existing configuration group, perform the following steps.A. In the Configuration Group window click the View Meters icon for the Configuration Group you want to view to display the Group Summary window.Draft 7.30.14
Landis+Gyr Chapter 2 - Command Center Deployment/ConfigurationUser Guide 98-1745 Rev AA 25 Figure 2 - 15. Group Summary WindowThe group membership list window displays the following categories:• Status. Status is the current status of the meter.•Total Meters. Displays the total number of meters in each status.B. Click any of the meter number links to view the Endpoint Properties window for the selected meter.2. In the Configuration Groups window click the New button to display the Configuration Group Properties window. Figure 2 - 16. Configuration Group Properties Window3. Enter a Group Name. The name must be unique within the organization.4. Enter any desired Group Notes.5. To set up Scheduled Commands use the following steps:A. Select the desired packet definition from the Command drop-down.B. Select the Time at which the reading will be taken from the meter. Adjust the time by clicking on either the hours, minutes, or AM/PM and then using the up or down arrow.C. Select the Frequency with which the reading will be taken from the meter.If either Every n minutes or Every n hours is selected, an additional field, N, will be displayed. Figure 2 - 17. Frequency IntervalDraft 7.30.14
Chapter 2 - Command Center Deployment/Configuration Landis+Gyr26 98-1745 Rev AA User Guide•Select the desired interval from the Frequency drop-down.D. Click the Schedule Command icon to add the command to the Scheduled Commands list. Figure 2 - 18. Scheduled CommandsE. (Gridstream endpoints only) Select the Delayed check-box for a command.6. Repeat step 5 for any additional commands.7. Select the Endpoint Transmit Interval from the drop-down. This setting determines how often the endpoint will transfer its readings to Command Center.8. Select the appropriate RF Network Settings from the drop-down.9. Select an RF Alarm Definition from the drop-down.10. Click the Save button to save the new configuration group.Add Meters to a Meter Configuration GroupAdding meters to a configuration group initiates the configuration process.1. Click Setup > Groups > Meter Configuration Groups and select the endpoint type.The Configuration Group screen will be displayed.Table 2-2. RF Network Settings ParametersDefault RF Collector ConfigurationHunt RFS Residential Configuration AHunt RFS S4 Configuration AHunt RFS Gas ConfigurationRF Residential Configuration ALG AU Residential Network Configuration ALG RF Commercial Configuration AParameterOutage Wait Value* 6 6 6 30Tamper Threshold** 10 0 0 0 30 0 10Time Synchronization (X, Y)† 1,1 20, 60 20, 60 20, 60 20, 360 20, 60 20, 1*Outage Wait ValueThe length of time (in seconds) that an endpoint will wait during a power outage situation before sending an outage notification to Command Cen-ter.**Tamper Threshold The number of reverse pulses of -kWh an endpoint must see within an interval before triggering a "Tamper Alert".†Time SynchronizationThe number of seconds that the meter time may drift before an automated time synchronization must be performed (X), or an alert must be gener-ated and sent to Command Center (Y).Draft 7.30.14
Landis+Gyr Chapter 2 - Command Center Deployment/ConfigurationUser Guide 98-1745 Rev AA 27 Figure 2 - 19. Configuration Group Window2. Click the Add Meters icon for the Configuration Group to which you want to add meters in order to display the Add Meters to Group window. Figure 2 - 20. Add Meters to Group Window3. Click the Meter(s) radio button and enter individual meter numbers separated by spaces, commas, or semi-colons....or...4. Click the Meter File radio button and then the Browse button to browse for a .csv file containing all the necessary meter numbers.5. Click the Add button and then the Exit button to save the additions.After clicking the Add button, the user will receive feedback on how many meter numbers were successfully and/or unsuccessfully added. The reason for an unsuccessful message is that the meter number does not exist.NOTE: If a meter is already in a configuration group, the meter will be removed from the original and added to the new configuration group.Draft 7.30.14
Draft 7.30.14
User Guide 98-1745 Rev AA 293Using Endpoint Testing Manager (ETM)How To Use ETMEndpoint Testing Manager (ETM) software provides the user with the ability to verify accurate module-to-meter, meter-to-module, module-to-network, and network-to-module communications. This chapter provides detailed instructions for navigating the software.Access to Endpoint Test ManagerWith the release of Command Center 5.0, ETM users must be authenticated into Command Center prior to accessing the ETM application and communicating with devices in the network. The designated Security Administrator for the utility is responsible for configuring the connection to the Command Center server, and for providing log in credentials (including user names and passwords) for those who will require access to the software.Setting Up Access to the Command Center ServerBefore launching the ETM software, a link to the Command Center server must be created. Follow the steps below to create the link to the Command Center server.•Launch ETM software. The ETM Sign in screen will open. On an initial launch of ETM, the ETM user must be authenticated with the Command Center server. The Command Center server connection places an authentication token on the user’s computer. This token is valid for a time specified by the Command Center Administrator. On succeeding launches, the Server Name field may display Offline, and may display Offline during future logins. Users may login to ETM without Command Center server connection, as long as their authentication token is valid. Figure 3 - 1. Endpoint Testing Manager - Sign InDraft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr30 98-1745 Rev AA User Guide•If this launch of ETM is not connected to a server, click the Select a new server link. The Server List will appear. Figure 3 - 2. Server List•Click the name of the desired server in the Server column to highlight it.•Click Select. The Server List window will close and the selected server will be displayed on the ETM log in screen.Adding a New ServerClick Add on the Server List. The New Server window will open. Figure 3 - 3. Endpoint Testing Manager - New Server• Server Nickname: Enter a user-defined name for this server.• Server Location: Enter the physical location of the server.• Server FQDN: Enter the fully qualified domain name for the server. (see example in the New Server display). • Make this my default Authentication Server. Enable this setting to connect to this server   each time this instance of ETM starts.•Click Submit to add the new server.Selecting an alternate existing serverAn ETM instance may have multiple servers associated to it. When ETM is first started, the server that has been selected by default will be displayed on the log in screen. The user may choose a different server, if necessary.Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 31Following is the procedure for selecting an alternate server:From the ETM log-in screen, select the Select a new server link. The Server List window will appear. •Click the name of the desired server in the Server column.•Click Select. The Server List window will close and if ETM can connect to that server, the selected server will be displayed on the ETM login screen.Modify an existing serverIf it is necessary to make modifications to an existing server, this task may be performed in the Server List window, shown previously in Figure 3 - 2.From the ETM log-in screen, click the Select a new server link. In the Server List window, click the name of the server to be modified.•Select the Modify button. The New Server window will open.•Make desired changes.•Click Save to apply changes.•Click Close to close the Server List window and return to the ETM login screen.Delete an existing serverIf it is necessary to delete an existing server, this task may be performed in the Server List window.In the Server List window, click the name of the server to be deleted.•Select the Delete button. The selected server will be removed from the Server List.•Click Close to close the Server List window and return to the ETM login screen.Add additional serversIf it is necessary to add additional servers, this task may be performed in the Server List window.In the Server List window, click the Add button. The New Server window will open.• Server Nickname: Enter a user-defined name for this server.• Server Location: Enter the physical location of the server.• Server FQDN: Enter the fully qualified domain name for the server. (see example in the New Server display)• Make this my default Authentication Server. Enable this setting to connect to this server   each time this instance of ETM starts.•Click Submit to add the new server.•Click Close to close the Server List window and return to the ETM login screen.Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr32 98-1745 Rev AA User GuideAfter Login: Setup CautionsNOTE: When ETM is first launched, view the Connection tab. Click the checkboxes for both Display Scrolling Status and Enable Test Reports, and then click Save Settings. Until changed, these settings will remain the default each time the ETM application opens.ACAUTION: Upon launch, ETM will attempt connection to the computer’s first available serial port. If an Integrated WAN Radio (IWR) is not connected to that serial port, ETM will time out. After ETM times out, click the Connection tab to select the serial port connected to the IWR.Certificate AttributesThe current status of the Mobile Admin Tool (MAT) Certificate can be viewed in the Security display. Figure 3 - 4. Security Menu OptionsFrom the menu options, select Security > MAT Certificate Attributes.The Token Attributes displays the current status of the MAT Certificate received from Command Center.  Figure 3 - 5. Token Attributes• NetWork ID. The Network ID is the utility’s unique Network Identifier. (For endpoints with v6.x firmware, this parameter cannot be changed in ETM)• Token Sequence Number. The Certificate Sequence number uniquely identifies the certificate issued for the MAT session.• Lan Address Block. The LAN Address Block displays the set of LAN Addresses that the MAT has been provided to use to communicate with endpoints. LAN Address block consists of 16 addresses, and are provided each time a certificate is requested from Command Center.• Token Expiration Time Stamp. Indicates the date and time that the MAT certificate will expire. The default value is 1440 minutes (one day) and is established in Command Center Organization Information settings.Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 33• Keep Alive. This value specifies the amount of time that a session between a MAT and an endpoint can be inactive before the endpoint closes the session. The default value is 15 minutes.• User Priority. The user priority field allows a user of a higher or equal priority to preempt an existing MAT Certificate. Users with a lower priority cannot gain access if a higher priority is engaged with the endpoint device. This also provides a method for the system to lockout a rogue user if a problem is detected on the endpoint.• Signature Expiration Time Stamp. This indicates the signature expiration for the MAT Certificate. It is set to three times the MAT Certificate expiration interval by default. This allows the MAT user to attempt to access an endpoint using the certificate and get a response back from the MAT rather than no response for a reasonable period of time before the certificate expires. A signed certificate is only required when endpoints are in ECC mode.Request MAT CertificateIn the event that a MAT Certificate is reaching its expiration time, a new MAT Certificate may be requested from Command Center by selecting the MAT Certificate option from the Security sub-menu.From the Menu options, select Security > Request MAT Certificate. The Log-in window will open. Figure 3 - 6. ETM Login screen• User Name: Enter utility-provided user name.•Password: Enter utility-provided password.• Server Name: The Server name field will display the server to which ETM will connect by default. •Click OK. If the user is successfully authenticated by Command Center, and the user has the proper privileges (Access and Certificate Authorization), Command Center will issue a MAT Certificate consistent with the level of security that the utility is using. NOTE: If a user’s session is nearing expiration, the user may also log out of ETM and log back in to get a new Certificate. If the ETM either has no Certificate, or the current MAT Certificate expiration is less than 50% of the original time interval, the MAT requests a new MAT Certificate.Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr34 98-1745 Rev AA User GuideETM Sign InThe ETM user and the ETM tool must 1) be known to and 2) authenticated by Command Center. The user must have been provided privileges and user credentials in order to access the ETM software. If the user has not been provided with credentials, the user must contact the utility-designated Security Administrator. The process of authenticating with Command Center provides the user with a Mobile Admin Tool (MAT) Certificate. The MAT Certificate confirms and certifies ETM’s identity to the endpoints. ACAUTION: ETM login has two modes: one with and one without server access (off-line). In off-line environments, ETM users must go on-line and successfully authenticate themselves to Command Center once every seven days.Below is the procedure for logging into ETM:Launch ETM. The Login to ETM screen will open. Figure 3 - 7. Endpoint Test Manager - Sign In• User Name: Enter utility provided your User Name.•Password: Enter utility provided password• Server Name: The Server name field will display the server to which ETM will connect by default. If needed, click the Select a new server link to connect to a different server, as described above.•Click OK. If the user is properly authenticated by Command Center and the user has the proper privileges (Access and Certificate Authorization), Command Center will issue a MAT Certificate consistent with the level of security the utility is using. If the user name and/or password is not authenticated, a warning dialog box will appear. The user may attempt to log in a total of five times with incorrect credentials before being locked out of the system. The Security Administrator will need to clear the locked out status via Command Center.Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 35 Figure 3 - 8. Login ValidationEven though the user may have certificate privileges, this message indicates that certificate server is not properly set up. (Possible reasons include: the server might be down or the signing utility might not be set up). If the user clicks OK, ETM will launch and they will be able to communicate to meters that are not in ECC mode.  Figure 3 - 9. Login ValidationThe authentication process provides the user with the required MAT Certificate. The length of time that the MAT certificate is valid is configured by the utility in the Organization Information settings, with the default being 1440 minutes.ACAUTION: If a MAT Certificate is nearing expiration, the user may log out of ETM and log back in to get a new Certificate. If the ETM instance either has no Certificate, or the current MAT Certificate expiration is less than 50% of the original time interval, the MAT requests a new MAT Certificate.Using the Bar-code ScannerPlease read the following information before using the barcode scanner to scan meter information.UWARNING: The bar-code scanner contains a laser light. Do not stare directly into the beam.NOTE: Ensure that the bar-code scanner beam covers the length of the bar-code.The figure below illustrates the proper method for scanning a bar-code.Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr36 98-1745 Rev AA User Guide Figure 3 - 10. Using the Bar-code ScannerNavigating the SoftwareETM is an easy-to-use software application that allows you to perform specific configuration, verification, and testing procedures. The application is comprised of an upper menu bar, the tabs listed below, and a Security Status line at the bottom of the display that describes the server connection and displays the connected endpoint’s security status.•Connection•Head End Radio•Device Test•Firmware Download•Module•Reporting•Command Scheduler•HAN (ONLY appears when a compatible endpoint is connected)•Universal Event Log•Service Limiting (ONLY appears when a compatible endpoint is connected)•Groups•RF Gas/Water (ONLY appears when the appropriate key is added to the Settings.XML file)•Collector (ONLY appears when ETM is connected to a Collector)Use the upper menu bar for exiting ETM, File > Exit, or to display or request Security details (as specified in the following section).ETM can also be configured to display an Activity Log at the bottom of each screen that allows the user to view communication activities between the tool and the endpoint.Configuring a New Gridstream IWR RadioThese parameters can be set via the Head End Radio tab. To configure a new Gridstream IWR radio:1. Connect the IWR to the PCTable 3-1. Upper Menu Bar Security Details Field DescriptionMAT Certificate Attributes Displays details about the Mobile Admin Tool certificate received from Command Center.Request MAT Certificate Sends a request to Command Center for a Mobile Admin Tool Certificate. Login permissions will vary access to this feature.Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 372. Select the Head End Radio tab3. Click the Modify button4. Change the radio's Network ID to match the utility-specified Network ID (for endpoints with firmware version v6.x and higher, this parameter is managed by Command Center and cannot be changed by ETM)5. Disable the router bit6. Disable the timekeeper bit7. Enable the head-end bit8. Enable the operational bit9. Set the baud rate to 3840010. Enter the Latitude and Longitude in the LPP Address field11. Click Apply to save changes.NOTE: If only the CRC and baud rate are to be changed, a new Gridstream IWR can be configured using ETM’s Head-end management. Command Center is used to manage the CRC for endpoints with firmware v6.x and higher.Meter Shop Best Practices Use Case - Proper IWR ConfigurationThis procedure describes proper configuration for IWR radios being used by any technician where the radio is on a production network. Do not:•Set up your IWR as a router. This will only slow down process actions as the IWR will be busy routing packets unnecessarily. On a production network this will interfere with the local mesh when the radio is turned off.•Set up your IWR as a head-end. This will cause significant problems with the production mesh network.•Set up your IWR set as a timekeeper. This is will pass the time of your computer to other network devices.Using RadioShop, confirm the following settings.NOTE: For information on RadioShop see RadioShop® Getting Started Guide, Landis+Gyr publication 98-1054.•Control Byte 1 - 69 is correct for a mobile IWR. The best way to change Control byte 1 is by setting WAN address under configure. As you change from a Mobile IWR to Fixed IWR CB1 changes from 69 > 49.•Control byte 2 should be HEX 48.•Control byte 3 should be HEX 50.ACAUTION: Control byte 3 is important. It prevents your radio from advertising a path to the Collector and from trying to register with Command Center every time it is powered on or reset.Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr38 98-1745 Rev AA User Guide•Control byte 4 should be HEX 69.•Control Byte 4 with RF Filter enabled and wide mode enabled should be HEX 29.•Control Byte 4 with RF Filter disabled and wide mode enabled should be HEX 28.•Max LAN Nodes could be set to 28 or 86 depending on your environment. If you are on a deployed Normal meter network, 28 would be the best setting. If you are working in a LARGE meter shop environment handling meter returns, sample testing, and First Article Testing Max LAN Nodes value 56 (hex 86) would be best.NOTE: Series IV radios appear in Command Center by default.Authentication Server ConnectionIf the current instance of ETM is not connected to the Authentication Server, ETM will display Work Offline in the status bar. Figure 3 - 11. Login ValidationConnecting to a CollectorOn the Connection tab, click the Collector Settings button to add a Collector. The Collector List dialog box will appear. Figure 3 - 12. Collector List Dialog1. When adding a Collector to the Collector List, click the Add button. The Collector dialog will appear. Figure 3 - 13. Collector Dialog2. Type a unique name into the Collector Name field.Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 393. Type the Collector IP address into the IP Address field with the numbers between the periods.4. Click the OK button to add the Collector.The added Collector will appear in the Host: drop down box, located on the Connection tab.5. To connect to the Collector, click Use Collector from the drop-down box.6. In the Host: drop down box, highlight the name of the Collector you would like to connect to.7. Click Connect.When the connection is successful, the Collector tab will appear in the tab group, ETM will navigate to the Device Test tab, and your radio will be set to field mode.Use the Disconnect button on the Connection tab to break communications with the Collector and return to standard head-end radio communications using the COM port.Connection TabThe Connection tab allows the user to view and change the connection information for the radio or Collector connected to the meter being tested. The table below describes the fields on the Connection tab.Table 3-2. Connection Tab Field DescriptionConnection Settings<connected to a radio> <Connect/Disconnect> - Use COM1 - at <baud rate> drop-down arrowThis button allows the user to Connect or Disconnect, contains a drop down menu that allow the user to choose a COM port or Collector to interface with your radio, and contains another drop down menu (Figure 3 - 14.) to select connection speed for the COM port. The available baud rates are:9,60019,20038,400 (default)115,200 (for Series IV IWRs)RadioShop can identify the COM port and baud rate of the radio you are using.<connected to a Collector> <Connect/Disconnect> - Use Collector drop-down arrow - choose Host drop-down arrowThis button provides for Connect or Disconnect, selecting the Collector to connect with, and uses a drop-down menu to list collectors available to host the connected module. When ETM is connected to a Collector, a tab labeled “Collector” appears. Host Allows testing meters in the field by displaying available collectors in the drop down box.Collector Settings <button> Allows the user to point Endpoint Testing Manager to a specific Collector using the IP address for the desired Collector.Application SettingsDisplay Scrolling Status check-boxAllows the user to choose the amount of detail displayed in the Activity Log at the bottom of each screen.Enable Test Reports check-box Determines whether test results are saved to the Test Reports file on your PC. Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr40 98-1745 Rev AA User GuideBaud Rate SelectionThe Baud Rate drop-down menu sets connection communications speed.Enable Field Mode check-boxChecking this box will allow the user to change the mode of the meter being tested. Unchecking this box allows the user to ensure that meters are not accidentally put into field mode during a meter test and will hide the buttons on the Device Test tab.AMR Password (Utility) drop down boxThis drop down box determines which AMR password is set when the test is run and the DCW is sent to the meter. Clicking the Setup AMR Passwords button allows the user to manage the AMR passwords that are available in this drop down box.Polling Interval (Secs) drop down boxDetermines how often ETM polls the meter for data. Available intervals are:5 seconds (default)10 seconds15 seconds20 seconds25 seconds30 secondsThis parameter is also used (and multiplied according to command choice) for meter response time-out settings, except for WECO actions.Log Trace Level drop down boxEnables the user to specify the level of information that is logged. The choices are:Off: no loggingError: only logs critical exceptionsWarning: logs all exceptionsInfo: logs all messages on a high levelVerbose: logs all activity (default)Current Encryption Key drop down box Lists available Encryption Key choices.Timeout Period (Sec) drop down box Configures the timeout setting parameter for the WECO library.Import Security Key <button>Allows the user to import an encryption security key from RadioShop and tell ETM what encryption key is used to encrypt/decrypt the meters tested.Setup AMR Passwords <button>If the meter tested supports AMR passwords, the utility can use this feature to give the Gridstream module the same AMR password as the meter so the two can communicate.Save Settings <button> This button activates saving connection settings so that next time ETM is launched, the saved settings are restored.Activity LogInsert Comment <button> Allows a user to insert comments into the Activity Log. These comments will also post to the Log file.Table 3-2. Connection Tab (Continued)Field DescriptionDraft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 41 Figure 3 - 14. Connection Baud Rate Option Select Drop-down Menu Figure 3 - 15. Connection Tab Connected to a RadioConnecting to an EndpointThe user can connect to an endpoint either through the computer’s COM port or through a Collector. The Collector Settings button is separate from the endpoint selection process, and enables operator entry of Collector endpoint connection parameters by using the dialog buttons to fill in or edit table information. Figure 3 - 16. Connection Tab Collector Settings dialogWhen connecting to any endpoint, the user clicks the Use... drop-down and selects either Collector or the computer’s COM port.Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr42 98-1745 Rev AA User Guide Figure 3 - 17. Connection Selection drop-downAfter Collector has been selected, the endpoint drop-down populates with the previous connected endpoint’s identifier. To select a different Collector, click the drop-down arrow. Figure 3 - 18. Choosing a CollectorHead End Radio TabThe Head End Radio tab displays information about the head end radio currently in use. The Head End Radio tab can also be used to configure Head End radio settings..Table 3-3. Head End Radio Tab Field DescriptionCollector / Integrated WAN RadioRadio: Displays radio type.Encryption: Displays whether encryption is enabled or disabled.Head-end Can be Enabled or Disabled. Firmware Version: Firmware version for the head-end radio being tested.Routing: Displays whether routing is enabled or disabled.Operational: Displays Operational Bit status as enabled or disabled.LPP Address:WAN and LAN address for the radio used in the test. After Modify is clicked, clicking in this field opens the Configure WAN Address dialog (Figure 3 - 20) and permits the user to specify radio WAN Address parameters. If the radio is a mobile unit, Routing, Time Keeper, and Collector Bit values cannot be changed.Network ID: Network ID for the radio being tested.Baud Rate: Displays the baud rate of the communications channel.Typ e : Displays whether Endpoint Testing Manager is connected to a Serial Radio or a Collector.Time Keeper: Enables or disables setting the radio as the timekeeper for the networkDraft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 43 Figure 3 - 19. Head End Radio TabReboot <button> Clicking this button restarts the radio’s main board.Modify <button> According to radio type, clicking this button allows the user to edit radio parameters.<Connection Status>Displays the connection status. The different statuses are:Connection SuccessfulNot Supported Meter DeviceFailed ConnectionCommandsGet WAN Nodes List <button>Queries the radio for a list of neighbors and displays these statistics in a dialog box. Clear WAN Nodes List <button>Deletes all entries from the current WAN Nodes List so that the radio can refresh the roster of neighbor radios.Test Device <button>Allows users to test the head-end radio (whether it's a serial head-end or Collector head-end radio), after connecting to the head-end using the Connection tab. This button will test the link to the connected head-end. After the connection is confirmed, the user can perform other tasks with it i.e. FW/DCW downloads.Birth Chirp Information (only available if head-end radio is in field mode)Listen for Birth Chirp for <secs> <button>Allows you to power up a meter and test to see if your head end radio can communicate with the meter. If so, the Network ID and mode will be displayed to ensure accurate testing. Use this button to discover a meter’s CRC and operational mode.Activity LogInsert Comment <button> Allows a user to insert comments into the Activity Log. These time-stamped comments will also list in the Log file.Status BarConnected to... Identifies Authentication Server connection and Security Mode.MAT Certificate Countdown Displays a time-remaining countdown for the current MAT Certificate.Table 3-3. Head End Radio Tab (Continued)Field DescriptionDraft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr44 98-1745 Rev AA User GuideClicking the Modify button activates access to many configuration settings and options on this tab. Entering changes and clicking Apply will provision the radio’s configuration settings with the entered changes. The radio may also be Rebooted after the Modify button has been clicked. Clicking the Cancel button closes access to these settings without making any changes. Figure 3 - 20. Configure WAN Address DialogClicking the Get WAN Nodes List button opens a window that lists neighboring endpoints and various parameters of those endpoints. Figure 3 - 21. Get WAN Nodes ListRight-clicking on any radio listed in the WAN Nodes Information table offers the choice of Copy Module ID To Clipboard (for continuing multiple reference), Test This Module (for immediate Device Test launch of that specific radio), or Reboot.Device Test TabThe Device Test tab provides options for running a test on a meter. The table below describes the fields located in the Device Test tab. Note that many of these fields are not populated until after a test on a meter has successfully concluded.Table 3-4. Device Test tabField DescriptionIdentifiersScan Module ID Scan or manually enter the module ID of the meter that is to be tested.Scan Serial Number Scan or manually enter the serial number of the meter to be tested.Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 45Scan Meter ID Scan or manually enter the meter ID of the meter to be tested.“Find device” <>Opens the Find device dialog for entering the Network Address and used to locate a device that is a neighbor of the head-end. This function looks at the neighboring devices of the head-end radio to see if there is one device that has the same WAN address. If found, the function pulls the module ID of that device and displays it in the Scan Module ID box. Start Test <button> Click this button to begin a meter test.Reset Test <button> Clicking this button resets the input fields.Module Test Results (these fields will only be populated after the tested endpoint has passed the test and communicated parameters to ETM)Endpoint Type of meter that is currently under test.Firmware Version Module, HAN, and meter firmware versions for the endpoint that has been successfully tested.LPP Address The WAN and LAN address for the module of the meter tested.Encryption Displays module encryption status as either enabled or disabled.Routing Displays whether module routing is enabled or disabled.Network ID Network ID for the connected module in both decimal and hexadecimal formats.Take Out Point Address for the Take Out Point associated with the tested module.Mode Settings <Current Mode>Displays the current mode of the module. Will be displayed as either Shop, Field, or Installation.Shop Mode is a special test mode, used while in manufacturing and diagnostic troubleshooting, that is turned off at the end of the manufacturing line. (not available for Concentrators)Field Mode is for working with installed modules, and sets the module to listen on the Network ID displayed on the Head End radio tab.Installation Mode is a temporary state that initiates the first network synchronization, and the auto registration process.MeterMeter Serial Number Serial number for the meter tested.Meter ID Meter ID for the meter tested.Disconnect Switch (only visible when the tested meter has an integrated switch)Status Displays the status of the disconnect switch.Switch Displays the switch state: either Connected or Disconnected.Armed Status Displays the armed state. May also display N/A, according to meter and firmware version.Utility Voltage Voltage that the utility is providing to the meter.Customer Voltage If service is connected, will be the same as the Utility Voltage. If disconnected, will be near zero.Table 3-4. Device Test tab(Continued)Field DescriptionDraft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr46 98-1745 Rev AA User GuideMode SettingsCurrent ModeCurrent mode of the IWR connected to the meter under test. The user may change the mode as needed. (If you are connected through a Collector, your IWR is always in Field Mode.)Go to <Mode> <button> Sets the radio to Shop Mode or Field ModeSet Endpoint to <Mode> <buttons>Sets the endpoint to either Shop Mode, Field Mode, or Installation Mode (if Firmware version is 421 or above), depending on the current state.With v6.x firmware, Set to Installation is the only enabled mode. Setting an endpoint to Shop mode is only enabled by a key provided by Landis+Gyr.Endpoint SettingsSet AMR Password <button> This button allows you to set the AMR password for endpoints being tested.Configure Encryption <button>This button opens a dialog used to enable or disable encryption on the meter tested.Disable Routing <button> This button disables routing through the meter being tested.Service Connect/Disconnect (only visible when the tested meter has an integrated switch)Connect <button> Closes the switch (energizes).Arm <button> Prepares the switch to be closed.Disconnect <button> Opens the switch (deenergizes).Get Status <button> Populates the Disconnect Switch section.Activity LogInsert Comment <button> Allows a user to insert comments into the Activity Log. These time-stamped comments will also appear in the Log file.Table 3-4. Device Test tab(Continued)Field DescriptionDraft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 47 Figure 3 - 22. Device Test Tab with Endpoint and Service Settings activeHigh Speed (115200 bps) EnableHigh Speed operation (also referred to as Wide Channel Mode) refers to configuring communications for 115200 bits-per-second data transmission. Table 3-5. “Find Device” Dialog Parameter DetailsField DescriptionNetwork Address The ID number, in decimal and hex formats, of the network that the radio under test is currently connected to.WAN AddressLatitudeThe latitude of the radio, expressed in:deg — Degreesmin — Minutessec — Secondsmsec — MillisecondsN/S — North or SouthLongitudeThe longitude of the radio, expressed in:deg — Degreesmin — Minutessec — Secondsmsec — MillisecondsN/S — North or SouthColor The parameter that differentiates multiple radios installed at one location (that is, sharing one WAN address).Decimal Degrees The WAN address of the radio, expressed in decimal degrees.Encoded Value (six bytes)The same WAN address as that specified by the Latitude, Longitude, and Color values.Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr48 98-1745 Rev AA User GuideFor high speed-capable endpoints an indication will appear on ETM’s Device Test tab when the endpoint is connected, as seen in the following figure. Endpoints that do not support high speed functionality will display High speed incapable in the Speed: call out. The user has the option to enable high speed operation in a compatible endpoint by clicking the Enable High Speed button in the Endpoint Settings section of the Device Test tab. Figure 3 - 23. High Speed StatusAfter High Speed is enabled, the Speed: call out will display High speed enabled and the Enable High Speed button label will change to “Disable High Speed.” Clicking the Disable High Speed button will reset the endpoint to function in standard (“Narrow Channel”) mode.NOTE: If an endpoint is put into high speed (or “wide channel”) mode, then any other radios that are running firmware earlier than v5.56 will not be able to communicate with the high speed endpoint directly. Endpoints that function in standard (“narrow channel”) mode can only communicate with radios operating in high speed mode as long as the standard mode radios are running firmware v5.56 or higher.Multiple Meter Test ModeOnce enabled, the Multiple Meter Test Mode supports a single ETM instance testing a large number of meters in one session. Enabling Multiple Meter Test ModeTo enable Multiple Meter Test Mode, you must use Windows Notepad (or your preferred text editor) to add a special key (provided by your Landis+Gyr Program Advisor) to the Settings.XML file located at: •C:\ProgramData\Landis+Gyr\Gridstream\Tool Settings\Settings.XML on Vista or Win7 systems.•C:\Documents and Settings\All Users\Application Data\Landis+Gyr\Gridstream\Tool Settings\Settings.XML on WinXP systems.NOTE: The Landis+Gyr program advisor can provide the key required to activate the Multiple Meter Test Mode feature.Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 49 Figure 3 - 24. Settings.XML File DetailEditing Multiple Meter Test Configuration Figure 3 - 25.  Accessing Multiple Meter Test Configuration Figure 3 - 26. Edit Multiple Meter Test Configuration DialogThe Edit Multiple Meter Mode Test Configuration dialog allows users to select the fields that will appear on the Multiple Device Test Results screen. The Edit Multiple Meter Mode Test Configuration dialog also supports data filtering by allowing users to specify values to test against for a selected field. Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr50 98-1745 Rev AA User GuideFor example, if the user wants testing to confirm that the module firmware version is 07.06, this parameter can be specified in the Module Firmware field of the Edit Multiple Meter Mode Test Configuration dialog. When the test is run, ETM will read the module firmware version from the meter and compare it with the user-specified value. If these values do not match, an error will display.Clicking File | Multiple Meter Mode | Run Test will open the Multiple Device Test Results screen. Meters to be tested are entered using the Add button at the lower left of that screen.  Figure 3 - 27. Multiple Device Test Results ScreenWhen the Multiple Device Test screen opens, ETM waits for a device ID to be entered so that it can begin testing. Testing can be halted by clicking the Stop button. After a Module ID is added, testing begins on the first device in the list, continuing through the entire list.Devices that pass testing will populate the columns with data selected on the Edit Multiple Meter Test Configuration dialog. Modules that fail testing will display Fail in a red-highlighted cell in the Test Status column. If the user hovers their cursor over the Fail indication, the reason for the failure will appear.The user can Retry testing on the selected module by clicking that button. Pressing the Ctrl+A keys selects all modules in the list.When testing is not active, the user can use the buttons at lower right to Clear WAN Nodes in the test, and Close the Multiple Device Test screen.After testing concludes, a log file is created and placed under the Multiple Meter Testing folder in the ETM installation directory.Firmware Download TabThe Firmware Download tab allows you to view the current firmware on the module and download a new firmware. For Modular Focus AX meters running 5.13 module firmware and above, ETM now supports metrology firmware download over the air. This action functions in a manner similar to Module/HAN firmware download.For Integrated Focus AX meters, only the Module Firmware option appears. The metrology firmware upgrade occurs automatically within the build. Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 51The table below describes the fields on the Firmware Download tab.NOTE: Field visibility on the Firmware Download tab will vary according to current module firmware version. There may be limits on firmware administration access with endpoints running module firmware previous to v6.x. Figure 3 - 28. Firmware Download Tab Connected to an Endpoint with v6.x FirmwareTable 3-6. Firmware Download TabField DescriptionDownload StatusFirmware Download Progress Displays the percentage status of a firmware download after the Start Download button is clicked.Module: Version <Firmware Version Number> Upgrade To: Drop Down BoxDisplays the module firmware upgrade versions that are available to and supported by the endpoint tested.The current firmware version is displayed in the title of the field. For example, Module: Version 251581-06.08Download Delay Rate (In Secs) Drop Down BoxSpecifies the delay (in seconds) between sending firmware packets. For large files, you can break up the firmware information that is sent between the radio and the module and ensure that network bandwidth is not overwhelmed. Start Download <button> Clicking this button will begin downloading the firmware version specified in the Upgrade To: drop down box to the module.Meter: Version <Firmware Version Number>Upgrade To: Drop Down BoxDisplays the meter upgrade firmware versions that are supported by the endpoint tested, and a list of the minimum and maximum meter firmware versions that the connected meter must be running in order to download the metrology firmware.The current firmware version is displayed in the title of the field. For example, Meter: Version 5.34.3Download Delay Rate (In Secs) Drop Down BoxSpecifies the delay (in seconds) between sending firmware packets as described in Module <F/W Version #> above. Start Download <button> Clicking this button will begin downloading the firmware version specified in the Upgrade To: drop down box.Activity LogInsert Comment <button> Allows a user to insert comments into the Activity Log. These time-stamped comments will also post to the Log file.Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr52 98-1745 Rev AA User GuideBattery End Point Firmware DownloadNo meter specifics will be displayed on this tab when ETM is connected to a battery end point. Module version will be displayed, and firmware unique to the connected (battery end point) module will be found on the drop-down menu.Select the firmware for download by highlighting and click the Start Download button to launch the event.Module TabNOTE: Due to the differences in meter setup with integrated Focus AX meters, only the Module Firmware option appears on the Module tab when ETM connects to an integrated Focus AX meter. Metrology firmware upgrades occur automatically within the build; other fields on this screen are not necessary for endpoint configuration.The Module tab is comprised of the DCW Information, Timing, Current Time, Set Time, and Command fields. The fields on this tab are only enabled if a meter has been run with a status of Passed. The table below describes the fields on the Module tab.Table 3-7. Module Tab Field DescriptionDCW InformationGet DCW Information <button> Provides the most current DCW information of the endpoint tested.Install DCW <button>Allows you to load a DCW on the endpoint tested.The DCW available for download will be limited to the latest specified DCW for the firmware version on the meter.TimingModule Time (GMT) Displays the current module time.Meter Time (GMT) Displays the current meter time.Get Time Delta <button> Generates a report that displays the difference between the module time and the meter time. Closing the report enables the Sync Meter and Module buttonSet TimeSync Meter and Module Time <button>On connected meters with applicable firmware, this button is enabled after the Get Time Delta button is clicked and the resulting report is closed. Once enabled, clicking this button synchronizes meter time with module time. After Meter and Module Time are synchronized, “Time Sync Completed” will display in the Set Time box.CommandDraft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 53 Figure 3 - 29. Module TabOptical LockoutFor compatible endpoints (FOCUS AX with metrology version 5.36 or higher, etc.), a section that appears on ETM’s Module tab is active, as seen in the previous figure. (Endpoints that do not support this feature will display this function, but it will be “grayed out” to represent connection to an incompatible endpoint).This setting includes options to:•Get current status•Lock the port indefinitely•Unlock the port for <user-specified> minutes•Unlock the port indefinitelyAfter a choice has been selected from the drop-down menu, the Send button executes the command. An illustration for the available Optical Lockout functions appears below.Optical LockoutWhen connected to compatible meters with applicable firmware, allows the user/tester to configure the meter’s Optical Lockout parameter. This setting includes options to:Get current statusLock the port indefinitelyUnlock the port for <user-specified> minutesUnlock the port indefinitelyThere is also a button to Send the command to the connected meter. When the time parameter command is used, a data entry field appears for entering the Minutes parameter.Activity LogInsert Comment <button> Allows a user to insert comments into the Activity Log. These time-stamped comments will also post to the Log file.Table 3-7. Module Tab (Continued)Field DescriptionDraft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr54 98-1745 Rev AA User Guide Figure 3 - 30. Optical Lockout Drop-down MenuFor the “X Minutes” selection, a data entry field appears for the user to enter the desired value, after which pressing the Send button, as with the other options, executes the command.Reporting TabThe Reporting tab is comprised of the Meter Information, ANSI Tables and Reports fields. The fields on this tab are only enabled if a meter test has been run and has a status of Passed.The table below describes the fields on the Reporting tab.Table 3-8. Reporting Tab Field DescriptionMeter InformationMeter Configuration Check-boxLoads tables to display meter specific configuration parameters (e.g. load profile, interval length, channel selection).“Landis+Gyr Meter Configuration” Check-boxLoads information about proprietary configuration parameters (time sync configuration, etc.).LP Data Check-box Loads tables that display the last two blocks of load profile data (interval data).Energy and Demand / TOU Check-box Loads Time-Of-Use tables for meter register data.Demand Reset Data / TOU Check-box Loads Time-Of-Use tables for meter demand data.Meter History Log Data Check-box Loads tables that displays the meter history.Latest Snap Read Check-box Loads tables for meter time-of-use data.Vector Data Check-box Loads tables containing instantaneous meter data.Meter Event Log Data Check-box Loads tables that display the meter events that have occurred.Status Summary Check-box Loads a table that displays disconnect switch status and meter time sync information.ANSI TablesStandard 000 - 099 Selecting specific check-boxes will load the corresponding ANSI Standard tables.Manufacturing 000 - 099 Selecting specific check-boxes will load the corresponding ANSI Manufacturing tables.Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 55 Figure 3 - 31. Reporting TabDemand ResetDemand Reset is a function performed on the meter. The meter stores peak demand information. A demand peak is determined by taking the kWh (kilo-watt hours) used over a configured demand window and converting it to kW (kilo-watts). This is done by multiplying the kWh by 60 and dividing that number by the window length. This information is used to bill the utility customer. Demand Reset is determined by taking the difference of the peak demand value between the current time and the time of the last Demand Reset.The purpose of the Demand Reset is to capture peak demand values and the times at which those values were recorded since the last time the Demand Reset procedure was executed. The Demand Reset takes a snapshot of the current instantaneous values, along with the demand readings, and ReportsLoad Required Tables <button> Loads the tables that are required to run a report.Load Defaults <button> Loads any tables that have been saved as default.Save As Defaults <button> Clicking this button will save currently selected tables as defaults that will be brought up at a later time by clicking the Load Defaults button.Clear All <button> Clears any check-boxes that are selected.Demand Reset <button> Launches the function. See details in the Demand Reset heading below. Generate Reports <button> Generates reports for the tables selected.Activity LogInsert Comment <button> Allows a user to insert comments into the Activity Log. These time-stamped comments will also post to the Log file.Table 3-8. Reporting Tab (Continued)Field DescriptionDraft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr56 98-1745 Rev AA User Guidestores that information in a holding place on the endpoint. As part of this process, the five highest demand readings are reset to zero.NOTE: The program administrator can provide the key required to enable and configure Demand Reset features.The Demand Reset action can only be activated after the Meter Configuration report has been retrieved. Select (click the checkbox beside) the Meter Configuration report option and click the Generate Report button. Once this report is obtained, the Demand Reset button will be enabled.Enabling Demand ResetTo enable the Demand Reset feature, you must use Windows Notepad (or your preferred text editor) to add a special key (provided by your Landis+Gyr Program Advisor) to the Settings.XML file located at: •C:\ProgramData\Landis+Gyr\Gridstream\Tool Settings\Settings.XML on computers using either the Vista or Win7 operating systems.•C:\Documents and Settings\All Users\Application Data\Landis+Gyr\Gridstream\Tool Settings\Settings.XML on computers using the WinXP operating system.Demand Reset LockoutThe Demand Reset feature is limited by the lockout window parameter. The lockout window is a safety feature to ensure that Demand Reset data will not be lost by accidentally executing too many demand resets.Some meters have a meter-enforced lockout period. During this lockout period, the meter will return an error code and no Demand Reset will be performed. By default, the Demand Reset lockout window is set to 24 hours. If a different value is preferred, locate the Demand Reset Lockout parameter in the Settings file mentioned above and change the number to set the hour value for the desired Demand Reset lockout window parameter.Performing a Demand ResetClicking the Demand Reset button on the Reports tab launches a Demand Reset action. The Activity Log will display Waiting for Demand Reset Response, followed by progressive communication events. For a successful action, Demand Reset response received and then Demand Reset Status: Success will display in the ETM Activity Log.  Figure 3 - 32. Demand Reset Status: SuccessSimultaneously, a Demand Reset report will display. This report is similar to the Demand Reset Data/TOU report output, except that it shows the status of the Demand Reset operation as Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 57highlighted below. The Demand Reset report also lists the previous number of demand resets reported by the meter. A portion of that report is shown below. Figure 3 - 33. Demand Reset ReportThe Demand Reset Report’s File menu offers options to Print a hard copy or to Save the report in XML or HTML formats, along with a Page Setup choice.Demand Reset RestrictionA Demand Reset Action may only be performed once every 24 hours.Command Scheduler TabThe Command Scheduler tab, as shown in Figure 3 - 34, is comprised of the Event Mask, Command Schedule, and Activity Log fields.ACAUTION: When an endpoint is hosted by Command Center, all schedules are managed by Command Center. Endpoint Testing Manager should not be used to make changes to this command schedule.Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr58 98-1745 Rev AA User GuideThe table below describes the fields on the Command Scheduler tab.Table 3-9. Command Scheduler Tab Field DescriptionEvent Mask: over 100 choices are available for notification scheduling. Choices for event masking include: Disabled, Log Only, Advisory, and Alarm.Erase ControlEraseZero Always the best choice for this screen. This option makes no changes to existing parameters.EraseAll Never to be used unless a start-from-zero meter commissioning action is in-process.EraseCommands Clears commands that have been entered into the Command section of the Command Scheduler tab.Command Schedule<Command Type>Cached Reads /Passthru PDU command / Interval Data Pump /Snap Read Pump /Advisory Events /Init Push Message /Meter Events /Radio Virtual Memory Read (Short) / WAN Node Information Read /Predefined Memory ReadCommand chosen by the user for implementation and notification.Start Time Displays the user-selected date and time for launching the specified command.<Period Type>Run Minute based /Run Day basedUser-programmed test parameter types for command launch intervals.<Test Interval Setting>Cached Read /                     Run Randomized /NormalUser-programmed test parameter intervals for command launch.Period display The user-defined data field that displays the test interval.Accept / Cancel Clicking this button sets the changed parameter for the command being configured or cancels the change.<Buttons>Get Scheduled Commands Polls the meter to refresh the scheduled commands.Display Scheduled Commands Report Displays a report of the scheduled commands.Set Scheduled CommandsLoads all new commands into the meter. The user MUST click Get Scheduled Commands to verify that the new commands have loaded. Confirmation does not appear in the Activity Log.Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 59 Figure 3 - 34. Command Scheduler TabEvent MaskThe Event Mask interface of the Command Scheduler tab supports user notification for specified events. These events include Primary Power Down, Primary Power Up, Procedure invoked, Table Written To, Event log cleared, Rate Change, and many others. There are over 90 Event Mask choices available for notificatio.To view currently-loaded meter commands and their status, click the Get Scheduled Commands button. Figure 3 - 35. Command Scheduler Event Mask Notification Options Activity LogInsert Comment <button> Allows a user to insert comments into the Activity Log. These time-stamped comments will also post to the Log file.Table 3-9. Command Scheduler Tab (Continued)Field DescriptionTable 3-10. Event Mask Events Event Mask Field DescriptionDisabled No notification when the specified event occurs; the event is not stored and will not be reported.Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr60 98-1745 Rev AA User GuideCommand ScheduleThe Command Schedule interface provides the user with the ability to schedule up to 12 specific commands, stipulate parameters for the scheduled commands, and set the Erase Control (this value must be set before sending any command). Drop-down arrows next to each parameter allow these commands to be programmed for specific dates and times and set to function in varying ways. Figure 3 - 36. Some Command Scheduler Command Types Figure 3 - 37. Command Scheduler Calendar Figure 3 - 38. Command Scheduler Test Interval Types Figure 3 - 39. Command Scheduler Test Interval SettingsLog OnlyThe event will be stored in the event log; it will not be reported in alarm/alert messages; only an on-request read of the event log will retrieve these events.Advisory An advisory message is generated when the specified event occurs; the event will be stored in the event log and will only be reported the next time a periodic push is transmitted; the periodic push will track the last event pushed to the host and will only send events that have not yet been pushed.Alarm The event will be stored in the event log and an immediate alert message will be transmitted.Table 3-10. Event Mask Events (Continued)Event Mask Field DescriptionDraft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 61NOTE: Some test interval options do not apply to all command choicesUniversal Event Log TabThe Universal Event Log tab, shown in Figure 3 - 41, is only enabled on meters with version 422-J or higher software. This tab enables user-programmable log activities that result from meter events. This feature is not supported by endpoints with firmware versions prior to 422-J. Endpoints with earlier firmware will return the message below when the Universal Event Log tab is clicked. Figure 3 - 40. Universal Event Log Tab Support Message Figure 3 - 41. Universal Event Log TabTable 3-11. Universal Event Log TabField DescriptionStart Date The user-programmable start date parameter.Start Event ID This parameter can be set from 1 to 254.End Date The user-programmable end date parameter.End Event ID This parameter can be set from 1 to 254.Event Report Type Set by the user to specify either Log Only, Advisory Only, or Alarm Only Report Types for meter events.Generate Report <button> Generates a report based on meter events, with options for setting up report appearance and saving these reports.Activity LogInsert Comment <button> Allows a user to insert comments into the Activity Log. These time-stamped comments will also list in the Log file.Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr62 98-1745 Rev AA User Guide Figure 3 - 42. Generate Report Data ViewService Limiting TabNOTE: The Service Limiting option is only available for Focus AX meters.Service Limiting functionality allows the utility to place a limit on the power used on certain accounts during a time period when they cannot disconnect power completely. As an example, to avoid customer hazard during freezing weather, some localities prohibit utilities from completely disconnecting service. When ETM connects to an endpoint, the application will verify whether or not Service Limiting is available with the connected endpoint. Service Limiting can only be enabled after Landis+Gyr supplies a proprietary key to the endpoint. If ETM has the required validation, the Service Limiting tab will appear.Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 63 Figure 3 - 43. Service LimitingFrom the Service Limiting tab, the user has the ability to read the Service Limiting Program for which the endpoint is currently configured, modify the existing program, and create a report of the service limiting program.NOTE: During the meter testing process, if the endpoint is not capable of remote connect/disconnect, the Service Limiting tab will be visible, but disabled.Service Limiting ModesThe following modes are available for service limiting programs:•Manual or Comm Only. This mode provides the user with the ability to create a Service Limiting Program that will configure the endpoint’s switch so that the switch will only be operated via communications from either an AMR device or software application.•Service Limiter. If “Service Limiter” is selected, the switch will also open when a configured load threshold is exceeded at the end of the sample interval. In Service Limiter mode, the trigger is an average value measured over a configured interval.Read ProgramRead Program allows the user to view the current Service Limiting control settings of the meter being tested:Select the Read Program button. The Service Limiting screen will refresh, displaying the endpoint’s Service Limiting Program.NOTE: If the meter has no service limiting program applied, the result will be Manual or Comm Only.Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr64 98-1745 Rev AA User GuideProgram Information.•Program Name. The program name identifies the service limiting program. •Notes. This is an optional field that allows for providing further information about the new program. •Mode. •Manual or Comm Only.•Service LimiterService Limiting optionsService Limiting parameters will vary depending on the mode selected.A. Manual or Comm Only. Closure prevention.•Prevent Switch Closure if load side voltage is detected. When selected, the meter will reject commands to close the service disconnect switch when load side voltage exceeds the configured percentage of nominal voltage.•If the closure prevention is enabled and the configured threshold is set to 25% of nominal voltage (in this case, 240V), the meter will reject a command to close if it detects a load side voltage in excess of 60V. NOTE: The recommended closure prevention setting is 25 - 40%•Threshold Percent of Nominal Voltage. Enter the desired threshold. Legal Values: 0 to 60% of Nominal Voltage when enabled. A value of 0 will disable the check.B. Service Limiter If “Service Limiter” is selected, the switch will also open when a configured load threshold is exceeded at the end of the sample interval. In Service Limiter mode, the trigger is an average value measured over a configured interval.Closure prevention•Prevent Switch Closure if load side voltage is detected. When selected, the meter will reject commands to close the service disconnect switch when load side voltage exceeds the configured percentage of nominal voltage.•If the closure prevention is enabled and the configured threshold set to 25% of nominal voltage (in this case, 240V), the meter will reject a command to close if it detects in excess of 60V of load side voltage. NOTE: The recommended closure prevention setting is 25 - 40%•Threshold Percent of Nominal Voltage. Enter the desired threshold. Legal Values: 0 to 60% of Nominal Voltage when enabled. A value of 0 will disable the check.Fused Settings•Amps at Nominal Voltage. This setting is a number between 0 and 60 that sets a threshold beyond which the switch will be opened.Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 65•Cumulative Demand same as Demand Interval [checked]. If this box is checked, this automatically sets the interval to the same interval used elsewhere in Command Center for automatic meter reads. •Cumulative Demand same... box [not checked]. If this box is not checked, the user must select an interval from the Interval button drop-down menu. The options are: 1, 5, 10, 15, 30, and 60 minutes.Open Options•Open Time. If instantaneous power (measured in watts) reaches a (programmable) threshold value, the switch will open for a configurable period of time, generally 0 - 30 minutes. •After Open Time Expires. Select the operation to be performed when the Open Time has expired. The switch can either be Closed, or the switch will Arm itself. When Armed, the switch will remain Open until the Reconnect button is pressed.•Limited Repeated Triggers. Limit Repeated Triggers, when enabled, causes the service disconnect switch to remain Open for an extended period if a number of Soft Fuse operations occur within a time window. For example, if a meter is programmed to allow no more than two operations within a 24-hour period, after the switch was triggered for the third time in 24 hours, the meter would remain open for 24 hours. At the end of that time, it would perform the operation it was configured to perform when the Open Time expired. Legal Values: 1 to 48 operations within a 1 to 24-hour window.Create a Service Limiting ProgramNew Service Limiting Programs may be created and saved to file for future application to meters. Following is the procedure for creating a new service limiting program.1. Enter the following Program Information:• Program Name: The program name identifies the Service Limiting program. Best practice for naming is to provide a functionality descriptive of the program. The name field is limited to fifty characters and must be unique to the organization. This field must be changed when creating a new Service Limiting program, or the existing Service Limiting program will be overwritten when the file is saved.•Notes: This is an optional file that allows for including up to 255 characters of additional information about the new Service Limiting program.•Mode: Select from the following modes:•Manual or Comm Only•Service Limiter2. Configure the Service Limiting parameters. Refer to the descriptions above.3. Click the Save icon to save the Service Limiting program to a file. Draft 7.30.14
Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr66 98-1745 Rev AA User Guide Figure 3 - 44. Service Limiting Program Information - Save Icon4. A pre-defined program location folder will open.5.  Enter a unique name for the new Service Limiting program.6. Click Save.The new Service Limiting Program has now been saved, and will be available for sending to an endpoint.Send an existing Service Limiting Program to an EndpointThe user may choose from previously created Service Limiting programs for sending to the device. NOTE: Best practice for configuring service limiting in the endpoint is to use Command Center functionality. Using ETM to alter the service limiting program may cause the endpoint’s configuration to be incorrectly reflected in Command Center. Following is the procedure for sending an existing program to the device:1. Select the Open icon. Figure 3 - 45. Service Limiting Program Information - Open Icon2. The Service Programs folder will open Figure 3 - 46. Service Limiting Programs3. Select the desired Service Limiting program file and click Open.Draft 7.30.14
Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)User Guide 98-1745 Rev AA 674. The Service Limiting programs tab will now display the selected program.5. Click Modify Program. 6. The selected Service Limiting Program will be sent to the endpoint, and the M33 report will appear. Figure 3 - 47. Service Limiting M33 ReportThe M33 report displays the current Service Limiting configuration settings applied to the endpoint. This report may also be generated by clicking the Generate Report button.Groups TabThe Groups tab is only enabled on meters with version 422 or higher firmware. This tab allows organizing meters into groups so as to enable actions and activities that are group-based. NOTE: A meter can belong to no more than eight groups. Figure 3 - 48. Groups TabDraft 7.30.14
Draft 7.30.14
User Guide 98-1745 Rev AA 694SpecificationsEnhanced Series IV AMPY 5252B SpecsTable 4-1. Specifications Category Specification Value or RangeCompatible Meters AMPY Supported Meter FormsForm Voltage Class2S 240 200ElectricalVoltage 6V (from the meter’s power supply)Power Max: 350mATypical: 295mARF 900 MHzOutput Power +26 dBm +/-1 dBmAdjacent Channel Power 39 dBc Nominal (9600 bps)Transmit Frequency 902.2 to 927.9 MHz ISM unlicensed (FCC Part 15)Communication Protocol Gridstream Protocol for Command CenterReceive Sensitivity  -100 dBm minimumStandards ComplianceFCC Title 47 CFR Part 15 Radiated and Conducted Emissions (incl. intentional radiators)IEC 61000 4-2,3,4,5,11,12 Electromagnetic CompatibilityANSI C12.19 Compatible with Utility Industry End Device TablesANSI C12.20 National Standard for Electricity Meters - 0.2 and 0.5 Accuracy ClassesANSI C12.1 Code for Electricity Metering ANSI C37.90.1 (1989) Standard Surge Withstand Capability (SWC) TestsANSI C12.22 Transport of ANSI C12.19 Over Network TransmissionsEnvironmentalGeneral Environmental Outdoor, rain-protected, sunlight-exposedOperating Temperature Range -30° to +70° C (under meter cover)Humidity 0 to 85% relative humidity, non-condensingDraft 7.30.14