Landis Gyr UTTR900M Meter with Utilinet transmitter User Manual Users manual
Landis + Gyr, Inc. Meter with Utilinet transmitter Users manual
Users manual
Landis+Gyr S4e UtiliNet User Manual Bulletin Revision A Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose without the express written permission of Landis+Gyr Inc. © 2003, Landis+Gyr Inc All rights reserved. For further information, contact: Landis+Gyr Inc 2800 Duncan Road Lafayette, IN 47904 USA Tel. 800-777-2774 Fax 765-742-0936 DOCUMENT HISTORY Bulletin: Revision Level Date Issued Description Bulletin Number: 20031201 Rev A S4e-UtiliNet User Manual Page 1 of 13 Landis+Gyr SAFETY WARNINGS ........................................................................................................... 3 FCC INFORMATION ............................................................................................................ 4 INTRODUCTION .................................................................................................................. 4 SYSTEM OVERVIEW ........................................................................................................... 5 S4E METER OVERVIEW...................................................................................................... 6 UTILINET MODULE OVERVIEW ....................................................................................... 6 CONFIGURATION OF THE UTILINET MODULE............................................................. 7 METER SETUP ...................................................................................................................... 7 METER INSTALLATION ...................................................................................................... 9 TROUBLE SHOOTING GUIDE..........................................................................................10 USE OF EXTERNAL ANTENNAS.......................................................................................10 TECHNICAL FEATURES OF THE S4E UTILINET...........................................................12 Bulletin Number: 20031201 S4E-UtiliNet User Manual Page 2 of 13 Landis+Gyr Safety Warnings The following safety precautions must be observed during all phases of operation, service, and repair of this device. Failure to comply with these precautions or with specific warnings elsewhere in these instructions violates safety standards of design, manufacture, and the intended use of the metering instrument. Landis+Gyr Inc assumes no liability for the customer's failure to comply with these requirements. • • • • Warning: Any work on, or near, energized meters, meter sockets, or other metering equipment can present a danger of electrical shock. All work on this product should be performed only by qualified electricians and metering specialists in accordance with local utility safety practices, utility requirements and procedures outlined in Chapter 14 of The Handbook for Electricity Metering (9th edition). The information contained within this manual is intended to be an aid to qualified metering personnel. It is not intended to replace the extensive training necessary to handle metering equipment in a safe manner. Remove the meter from service prior to installing the antenna isolation kit and/or remote external antennas. Be aware that dangerous voltages exist at several points within the meter when this product is installed on a meter socket. Always disconnect power before meter disassembly, soldering, or replacing components. The S4e meter is connected directly to line potential. Due to the possibility of the potential lines being reversed, points accessible with the cover off may be at line voltage. LINE POTENTIAL IS PRESENT ON THE INCOMING CONNECTORS ON THE MEASUREMENT BOARD INCLUDING THE BATTERY CONNECTOR. The connectors have full-length insulators crimped onto each connector, which are shielded by the housing. However, pulling the connector loose will expose the battery terminals, which may be at line potential. The option board is connected directly to the main board and may be at a high potential. A Mylar shield prevents touching the option board. Removing the Mylar shield exposes line voltage. The above warning label affixed to the meter frame identifies hazards in the meter. Failure to follow all instructions may result in an unsafe product that could cause injury or death CAUTION: DO NOT OPERATE METER WITHOUT ANTENNA ATTACHED. OPERATION WITHOUT ANTENNA MAY CAUSE PERMANENT DAMAGE TO THE UTILINET MODULE. Bulletin Number: 20031201 Rev A S4e-UtiliNet User Manual Page 3 of 13 Landis+Gyr FCC Information This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Landis+Gyr could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult Landis+Gyr or an authorized technician for help. LAN Address FCC ID Number Introduction Bulletin Number: 20031201 Rev A S4e-UtiliNet User Manual Page 4 of 13 Landis+Gyr The S4e UtiliNet is Landis+Gyr’s latest polyphase meter product targeting advanced communications for commercial and industrial metering needs. The S4e UtiliNet is a marriage of Landis+Gyr’s 4th generation solid-state commercial and industrial meter with an under-glass UtiliNet module. It provides the following benefits: • Low operational cost AMR solution • Cumulative, Interval, Registers and Event Data • On Demand or On Schedule Reads • Supports small to large deployments System Overview The S4e UtiliNet system looks as follows: RTscada Network Take-out point BLT Bridge WanGate Radio S4e under glass radio Focus residential meter & Cellnet end points Data acquisition can be provided by a hosted service for small to large meter deployments or an own and operate solution. The UtiliNet network provides secure, packet based data transfer. The Landis+Gyr designed UtiliNet module supports the following system services: • • • Uses Device Control Word (DCW) programming language Spread Spectrum Frequency Hopping Technology Utilizes an Unlicensed Frequency Band Bulletin Number: 20031201 Rev A S4e-UtiliNet User Manual Page 5 of 13 Landis+Gyr • • • Devices act as end devices and repeaters Utilizes packet switching data transmission Increase coverage by adding more radios S4e Meter Overview All S4e meters include wide-dynamic voltage application capability, forms reduction, Service Scan automatic service recognition, and GyrBox installation diagnostics and monitoring. The S4e is available with several register types, providing the right functionality for any metering application. The S4e UtiliNet can be ordered with the following register configurations: AX AXR 32K AXR 128K RX RXR 32K RXR 128K Active Active Active Active Active Active energy, Demand or TOU energy, with a 32K byte load profile recorder energy, with a 128K byte load profile recorder and reactive measurement, Demand or TOU and reactive measurement with 32K byte load profile recorder and reactive measurement with 128K byte load profile recorder An optional input/output board provides up to 2, form C, solid-state relays and up to one external inputs for recording pulses from a remote source. The 4 relay option board is not available with the S4e UtiliNet meter. One external input can also be used for real-time rate changes or self-read actuation. The board can be easily added in the field without the need for special tools or soldering. For additional information on the S4e meter, consult the S4/S4e Solid State Meter Instruction/Technical Manual. UtiliNet Module Overview The S4e meter is modular in its design. The UtiliNet module occupies the communications board slot in an S4e meter. Bulletin Number: 20031201 Rev A S4e-UtiliNet User Manual Page 6 of 13 Landis+Gyr Configuration of the UtiliNet Module The S4e UtiliNet meter is programmed using 1132Prog/1132Com. The UtiliNet module is factory programmed with a LAN Address. Meter Setup The Utilinet module relies on certain inputs from relay 4 for its operation. As a result there are a few minimum programming requirements for the S4 (using 1132Prog). The load control relay activates the relay upon power up. This relay triggers the UtiliNet module to power up. If the meter is not programmed as shown below the UtiliNet module will not operate as expected. A special tool, Utilinet Radio Tool, was developed to query and reboot the UtiliNet module. Relays: Set Relay 4 to Load Control (“LC”), “Used” in Normal Mode and Normal Off State to “Closed”. Bulletin Number: 20031201 Rev A S4e-UtiliNet User Manual Page 7 of 13 Landis+Gyr TOU Rates Schedule: Set AX/RX Only? to “Yes”, and Schedule Relay? to “Yes” Bulletin Number: 20031201 Rev A S4e-UtiliNet User Manual Page 8 of 13 Landis+Gyr Also, Set all Switchpoints to “OFF” in the Rates Schedule Meter Installation Step 1. Installing S4e UtiliNet Meter If existing meter is present, follow company procedures for meter removal and installation. (Note: Meter removal and installation should only be performed by a properly trained technician.) During communication the LCD will flash P/R in the alphanumeric segments. Bulletin Number: 20031201 Rev A S4e-UtiliNet User Manual Page 9 of 13 Landis+Gyr Step 2. Verifying the S4e UtiliNet Communicates Over the Network Trouble shooting Guide Symptom Possible Causes S4e Meter LCD Display Blank UtiliNet Not Communicating UtiliNet communicates but not connecting to host UtiliNet communicates but no load profile sent Check voltage to meter Check Module to Meter Connection Verify correct DCW Programming. Use UtiliNet Radio Tool to check UtiliNet programming status. Verify that S4e meter recorder is programmed. Using 1132Com perform a View Data and check that meter device type detected as AXR or RXR and that the load profile settings are correct. Use of External Antennas S4e UtiliNet equipped meters are manufactured with an internal antenna. However, some meter locations have less than optimal RF reception. Many meter services are ungrounded. Examples of these types of services include single-phase form 2S, as well as floating 3-wire delta services, 12S and 45S/5S. To improve the reliability and safety of these floating services, Landis+Gyr has developed an interface for remotely mounted antennas that allows RF reception under these service conditions. The High Voltage antenna coupling system protects UtiliNet components from transients reaching up to 7,000 volts. The Landis+Gyr External Antenna Isolation Solution needs to be installed in the S4e meter in accordance with Landis+Gyr Specifications. Contact the factory for more information regarding ordering and installing approved external antenna solutions. See the diagram on the next page. Bulletin Number: 20031201 Rev A S4e-UtiliNet User Manual Page 10 of 13 Landis+Gyr Signal OEM2284 Internal Antenna Meter Cable Bracket OEM2232 Bulletin Number: 20031201 Rev A S4e-UtiliNet User Manual Page 11 of 13 Landis+Gyr Technical Features of the S4e UtiliNet S4e and UtiliNet Specifications Applicable Standards ANSI C12.1-2001 ANSI C12.10-1987 ANSI C12.20-1998 CAN3-C17-M84 CAN3-Z234.4-79 FCC Industry Canada NOM Application Information Frequency Nominal Voltage Operating Voltage Operating Temperature Meter UtiliNet Radio Humidity for electricity metering for watt-hour meters for solid-state electricity meters Canadian Specs for approval of electrical meters Canadian Specs for all-numeric dates and times Certified Part 15.247 RSS 210 121-SCTI-1994 50 or 60 Hz +/- 5% 120-480 VAC ranging 80-115% of nominal -40 to +85 C under cover -40 to +60 C under cover Meter Less than or equal to 95% relative humidity, non-condensing UtiliNet rated 650 C at 90% relative humidity, non-condensing Meter Rated Accuracy at Unity Power Factor Transformer-Rated/ Self Contained Meters +/- 0.2% K-Base Meters +/- 0.5% Over voltage Withstand Temporary (.5 sec) 150% rated voltage Continuous (5 hours) 120% rated voltage Starting Load: Class 20 0.004 amps Class 200 0.050 amps Class 320 0.050 amps Available Meter Forms Base Transformer Rated Class 20 S-Base 3, 9/8, 45(5)*, 36(6)*, 29, 56 A-Base 10/8, 45(5)*, 36(6)* Class 120 Class 200 Class 320** 2, 12, 25, 16/15/14 2, 12, 16/15/14 Class 480 16/15/14 K-Base 12, 16/15/14, and 27 *36S/36A replaces the traditional 6S/6A, 45S/45A replaces the traditional 5S/5A **Class 320 Meters are referred to as SE base Bulletin Number: 20031201 Rev A S4e-UtiliNet User Manual Page 12 of 13 Landis+Gyr UtiliNet Specifications General Frequency Range Channels Channel Spacing Raw RF Data Rate Spreading Technique Hopping Technique Hopping Patterns Network Address Receiver Type Dynamic Range Packet Error Rate IF Selectivity 45 MHz IF Rejection Frequency Stability 902-928 MHz 240, 25kHz wide 100 kHz 9600 bps Frequency Hopping Pseudo Random, Asynchronous 65,536 (Unique per Network) Latitude/Longitude Coordinates Double Conversion Superheterodyne; 1st IF 45 MHz, 2nd IF 455 kHz -104 to -20 dBm 1x10-2 (1x10-6 BER) 6 dB down @ 30 kHz <90 dB 2.5 ppm (0.00025%) @ -30° to +75° 5 ppm (0.0005%) @ -40° to +85° Transmitter RF Output Min (at antenna conn.) +17 dBm (50 mW) RF Output Typical +20 dBm (100 mW) Out-of-Band Spurious Radiation < -55 dBc (1kHz bandwith) Deviation ±5.5 kHz ±10% Module Bandwith 25 kHz Modulation Standard FSK Output Impedance 50 Ohms Frequency Stability 2.5 ppm (0.00025%) @ -30° to +75° 5 ppm (0.0005%) @ -40° to +85° Bulletin Number: 20031201 Rev A S4e-UtiliNet User Manual Page 13 of 13
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2004:07:13 13:53:02-04:00 Create Date : 2004:07:13 11:12:53-05:00 Company : Siemens Metering, Inc. Source Modified : D:20040713161237 Page Count : 13 About : uuid:743f84bc-4458-4c1f-a6c3-2e11abf8ca7f Producer : Acrobat Distiller 6.0 (Windows) Mod Date : 2004:07:13 13:53:02-04:00 Creation Date : 2004:07:13 11:12:53-05:00 Author : Richard G. Pate Headline : Creator Tool : Acrobat PDFMaker 6.0 for Word Metadata Date : 2004:07:13 13:53:02-04:00 Keywords : Document ID : uuid:d98c9256-ffc2-42b7-8309-422bc1daa6ab Version ID : 39 Format : application/pdf Title : Specific steps are required to insure that the pager is not damaged when installing a meter equipped with an external antenna Creator : Richard G. Pate Subject : Tagged PDF : YesEXIF Metadata provided by EXIF.tools