Larcan MX100U Translator User Manual BZ5MX100U

Larcan Inc Translator BZ5MX100U

BZ5MX100U

Download: Larcan MX100U Translator User Manual BZ5MX100U
Mirror Download [FCC.gov]Larcan MX100U Translator User Manual BZ5MX100U
Document ID231638
Application IDfSwDBiK/rvgylyAz43sfhA==
Document DescriptionBZ5MX100U
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize15.64kB (195538 bits)
Date Submitted2002-03-18 00:00:00
Date Available2002-05-24 00:00:00
Creation Date2002-02-19 10:11:13
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2002-02-19 10:17:04
Document TitleBZ5MX100U
Document CreatorAcrobat PDFMaker 5.0 for Word
Document Author: ramejia

PUBLICATION TSM 20-308
TECHNICAL MANUAL
100 WATT UHF AMPLIFIER
FOR MX100U SERIES
TV TRANSMITTER/TRANSLATOR
LARCAN INC.
228 AMBASSADOR DRIVE
MISSISSAUGA, ONTARIO
CANADA L5T 2J2
PHONE:
FAX:
(905) 564-9222
(905) 564-9244
Rev 0: November 9, 1999
MX Series - 100 Watt UHF AMPLIFIER
Section
Title
Page
NOTICES, ETC. ...............................................................................................................................3
SAFETY AND HEALTH WARNINGS ............................................................................. 4&5
GENERAL SERVICE INFORMATION
1) Parts Lists Explained..........................................................................................5
2) Interpreting LARCAN Drawing Numbers............................................................5
3) The LARCAN Assembly Prefix Numbering System ...........................................6
4) List of Prefix Numbers for the 100 W Amplifier ..................................................7
5) Production Changes...........................................................................................7
INTRODUCTION .................................................................................................................8
GENERAL DESCRIPTION..................................................................................................8
SPECIFICATIONS.............................................................................................................10
ABOUT THIS MANUAL .....................................................................................................11
PUBLICATIONS LIST for MX series 100W UHF Amplifier:
PUB99-30 100W UHF Amplifier Installation:
1.
General Information..............................................................................30-1
2.
Grounding and Ground Loops..............................................................30-2
3.
Lightning and other Transient Protection .............................................30-4
4.
Power Wiring ........................................................................................30-9
5.
Ventilation and Air Conditioning .........................................................30-10
6.
Fire Protection ....................................................................................30-11
7.
Unpacking ..........................................................................................30-12
8.
Transmitter External Interlock Connections .......................................30-12
9.
On Site: First Time Start-up................................................................30-13
PUB99-31 100W UHF Amplifier (Prefix 2):
1.
Amplifier Chassis Description...............................................................31-1
TSM 20-308 rev 1: April 3, 2000
100 W UHF Amplifier
MX Series - 100 Watt UHF AMPLIFIER
Section
Title
Page
PUB99-32 Heatsink Assembly:
1.
Heatsink Assembly Description............................................................32-1
2.
Front End Module.................................................................................32-2
3.
IPA1 Module.........................................................................................32-2
4.
IPA2/PA Module ...................................................................................32-4
5.
Two-way Splitter/Combiner ..................................................................32-5
6.
+28V Voltage Regulator .......................................................................32-5
PUB99-33 RF Output Metering Board (Prefix 4):
1.
RF Metering Board Description ............................................................33-1
2.
RF Metering Board Test and Calibration..............................................33-2
PUB99-34 100W UHF Power Supply (Prefix 1):
1.
Power Supply Chassis Description ......................................................34-1
2.
Control Panel .......................................................................................34-2
3.
Control Board Assembly Description ...................................................34-2
PUB99-35 100W UHF Basic Transmitter Maintenance:
1.
General.................................................................................................35-1
2.
Daily .....................................................................................................35-1
3.
Weekly..................................................................................................35-2
4.
Monthly.................................................................................................35-2
5.
Semi-annually and Annually.................................................................35-2
6.
Transmitter Cooling System .................................................................35-2
7.
Static 1, Equipment 0: A brief Static Tutorial........................................35-3
8.
FET and Surface Mount Replacement .................................................35-4
9.
Replacement Parts...............................................................................35-7
10.
Spare Parts Recommendations ...........................................................35-9
CADCO M-369 Manual
CADCO P-379 Manual
TSM 20-308 rev 1: April 3, 2000
100 W UHF Amplifier
MX100 Series - 100 Watt UHF AMPLIFIER
NOTICES, ETC.:
THIS EQUIPMENT USES STATIC-SENSITIVE CMOS INTEGRATED CIRCUITS. Observe proper
handling precautions (indicated in Maintenance Sections) at all times when working with this equipment.
TOXIC MATERIALS NOTICE... IMPORTANT...
Effective thermal management in certain semiconductor devices in this equipment is possible only through
the use of Beryllium Oxide ceramic materials. This equipment contains devices made with Beryllium
Oxide!
Beryllium and its compounds is a POISON if taken into the body in any manner.
To reduce your risk, remember: In case of accidental breakage of any kind of semiconductor
device, DO NOT INHALE THE DUST, and AVOID GETTING DUST IN YOUR MOUTH; it could contain
Beryllium. DO NOT LET BERYLLIUM DUST INTO YOUR BLOODSTREAM THROUGH CUTS OR
OPEN WOUNDS!
Seek and obtain IMMEDIATE medical attention if the dust enters your body in any manner.
Avoid cuts by wearing gloves while picking up the pieces. Wash your hands thoroughly after
replacing devices. Dispose of defective devices only through approved toxic waste disposal
facilities.
Remember too, after cleaning up an accidental breakage, avoid inhaling the dust while replacing or
emptying vacuum cleaner filter bags, and wash your hands well after servicing the vacuum
cleaner.
All material in this manual is copyright © LARCAN INC. and reproduction in whole or in part in any form for
any purpose other than exclusive use of the equipment owner, without prior written authorization from
LARCAN INC. is prohibited.
Trademarks are the property of their respective owners and are mentioned in the text for discussion
purposes; any such mention is not necessarily an endorsement of the trademark or its owner. Parts lists
may also contain trademarked vendor names as an aid in procurement of spare parts. We apologize for
any inadvertent omission of trademark acknowledgement; any such omission was completely accidental.
Although the following pages contain as much information about the 100W UHF Amplifier as it is
reasonably possible to provide, nevertheless we must state that these instructions do not purport to cover
all details or variations in equipment nor to provide for every possible contingency to be met in connection
with its installation, operation, or maintenance. It is assumed that fully competent technical personnel will
be responsible for the maintenance and repair of the equipment that is described in this manual. Should
further information be desired, or should particular problems arise which are not covered sufficiently herein
for the purchaser's purposes, or should replacement parts be required, the matter should be referred to us.
LARCAN INC.
228 Ambassador Drive,
Mississauga, Ontario, Canada L5T-2J2.
Telephone (905) 564-9222, FAX (905) 564-9244
TSM 20-308 rev 1: April 3, 2000
100 W UHF Amplifier
MX100 Series - 100 Watt UHF AMPLIFIER
TRANSMITTER SAFETY PRECAUTIONS:
AC VOLTAGES USED FOR THE OPERATION OF THIS EQUIPMENT ARE DANGEROUS TO HUMAN
LIFE!
This instruction manual has been written for the general guidance and information of operation,
maintenance and service personnel who are aware of, and are familiar with, the hazards of working with
high powered electronic circuits.
This manual does not purport to detail all of the safety precautions that should be observed when servicing
this or any other electronic equipment. Servicing by inadequately trained or inexperienced personnel may
expose such personnel to serious risks that could result in personal injury or death, and/or damage to this
equipment. All personnel concerned with the servicing of this equipment should be thoroughly familiar
with standard first aid procedures for the treatment of electrical burns and shock.
The equipment has been designed to protect operating personnel from accidental contact with voltages
dangerous to human life, either by means of distance (where it is necessary to deliberately reach to make
contact with live terminals) or with shielding. It is therefore of prime importance that any protective
covering devices are kept in place at all times.
While all practical safety precautions have been adopted to safeguard personnel from possible injury, in
times of off-air emergency there is often a strong tendency to act without due regard for normal caution;
for this reason, both supervisory and operating personnel are urged to ENSURE THAT THE SAFETY
RULES DETAILED BELOW ARE FOLLOWED AS AN ESTABLISHED ROUTINE at all times.
1.
KILL THE AC POWER BEFORE IT KILLS YOU
Under no circumstance should any person reach within the cabinets for the purpose of servicing or
adjusting the equipment without first disconnecting the AC power, or without the immediate presence of
another person capable of rendering aid. Use of the buddy system is encouraged for transmitter work.
2.
DO NOT TAMPER WITH INTERLOCKS OR SAFETY SHIELDS
Under normal circumstances no safety shield should be removed.
3.
REMOVE PERSONAL JEWELRY WHEN WORKING ON THE EQUIPMENT
The 48 volt power supply in this transmitter, although overload protected, is able to deliver currents
capable of heating metallic tools or personal jewellery such as a watchband, bracelet, or ring. Accidental
short circuits from such metallic objects can cause them to heat sufficiently to result in serious personal
injury.
4.
KNOW FIRST AID, AND KEEP FIRST AID SUPPLIES AVAILABLE
Illustrated first aid instructions for the treatment of electrical shock and burns should be displayed in a
prominent location adjacent to the equipment. In rendering first aid, the timeliness and effectiveness of
the treatment are vitally important to the recovery of the injured person.
Without exception, all personnel should thoroughly familiarize themselves with the procedures involved.
One person, whose regular duties place him or her at the transmitter site often, should be delegated and
given the complete responsibility and authority to ensure that first aid supplies are kept on site and
maintained fresh and up to date.
Prominently display a list of emergency telephone numbers. This list should include the telephone
numbers of the nearest ambulance, hospital, doctor, and fire department paramedics; and the public
works (highways or county roads) department in case the former persons need access to the site during
inclement weather.
TSM 20-308 rev 1: April 3, 2000
100 W UHF Amplifier
MX100 Series - 100 Watt UHF AMPLIFIER
TSM 20-308 rev 1: April 3, 2000
100 W UHF Amplifier
MX100 Series - 100 Watt UHF AMPLIFIER
HEALTH WARNINGS:
1.
Non-metallic coverings of some coaxial cables used in this equipment are FLAMMABLE and may
transmit fire when ignited. Other wire coverings are not capable of supporting combustion, but
any non-metallic covering when heated sufficiently may emit dense smoke and acid gases which
can be highly TOXIC and often CORROSIVE.
2.
Be careful when replacing RF power transistors. Thermal transfer properties in these devices are
achievable only by the use of Beryllium Oxide ceramics. We stated it earlier but we will
emphatically repeat it again and again, Beryllium Oxide is a TOXIC substance. If the ceramic
or other encapsulation is opened, crushed, broken or abraded, the Beryllium Oxide dust can be
hazardous if taken into the body in any manner. Use caution in replacing these devices.
3.
Solvents such as alcohol, ketones, aliphatic or aromatic hydrocarbons, halogenated
hydrocarbons, etc. as found in glues, paints, paint thinners, paint removers, and/or cleaning fluids,
may emit TOXIC VAPOURS and some may be FLAMMABLE. Read and understand the
directions on their containers, and ensure that they are used only in well-ventilated locations.
GENERAL SERVICE INFORMATION
1.
Parts List Layout - EXPLAINED
Parts lists for manuals are computer-generated out of the LARCAN materials management database.
They are presented in hierarchical or family tree order.
The computer is input with the parent parts list number, in this case the amplifier model 40D2206G1 which
it designates as level 0. The computer first checks the parent list for major subassemblies, then each
subassembly list for more subassemblies, etc., and arranges these lists in order of hierarchy beginning
with level 0, then 1, then 2, etc., then prints each in the order in which they were found. In these booklets
which together describe the PARTS of the amplifier, we have used the computer's electronic data output
to allow us to more easily integrate the relevant parts list with the text.
The line of text immediately above the horizontal line on the first page of each list provides the number
and name of the relevant assembly that the list represents.
An "R" followed by a dash and a number indicates revision status. This information is meaningful to our
Renewal Parts and/or Customer Service people, and in order that these people can be most helpful, they
should be advised of this revision number especially if renewal parts are needed.
2.
Interpreting LARCAN Drawing Numbers
Engineering drawings at LARCAN are based on the concept that an assembly or subassembly is simply a
GROUP of component parts, thus when a G appears on a list, it means an "assembly". Thus a circuit
board loaded with parts may be referenced in this manual as "21B1389G1". In this example, G1 is the
amplifier used in the IPA2 stage while G2 is the amplifier used in the PA stage. Furthermore, the `P’ in
21B1389P1 indicates that this is a part in itself (a printed circuit board) with no parts in it. In this case this
part is called up in 21B1389G1 parts list. The `S’ in 21B1389S indicates that this is a schematic diagram.
In some cases the schematic diagram may be a completely different number.
TSM 20-308 rev 1: April 3, 2000
100 W UHF Amplifier
MX100U Series - 100 Watt UHF AMPLIFIER
2.
GENERAL SERVICE INFORMATION
Interpreting LARCAN Drawing Numbers (continued).
Other assemblies may be shown as a number of separate assemblies (Parts 1, 2, 3, 4, or 5), on several
sheets of a single drawing. The drawing "parts" all are assembled the same way, but vary in quantity and
type of components.
For vendor components such as resistors and capacitors, often a generic drawing describing basic
specifications, but having many "parts", will be used.
As an example, Drawing 3R152: Resistor, composition, ¼ watt. Drawing 3R152 describes a ¼ W resistor,
but the drawing PART number calls for the value and tolerance of the resistor wanted. The first two digits
after the "P" are the first two significant figures of the resistance, the third digit is the number of following
zeroes in the resistance value, and a J is 5% tolerance, or K is 10% tolerance. Some example part
numbers are: 47 Ω, ±10%, ¼W, is "3R152P470K"; and "3R152P243J" specifies 24 kΩ, ±5%, ¼W. For
resistance values between 1 Ω and 10 Ω, a letter "R" will appear in the part number to indicate the decimal
place; for instance a 5.6 Ω, ±5%, ¼W resistor will be designated as "3R152P5R6J".
Often the letter "R" appears on schematics or in parts lists where it specifies the decimal place when
referring to resistances, such as "51R" or "75R" or "5R6", and sometimes the letter "k" will appear in the
same context, such as "3k3". This practice is deplored by old-timers in our midst who attended North
American tech schools and therefore learned about component values that are specified with the use of
decimal notation, but schematics drawn this way are common in other parts of the world. In a parts list,
moreover, an R followed by a dash and a number indicates a revision, but you will be able to recognize
the difference from the layout framework of the list.
3.
The LARCAN Assembly Prefix Numbering System
Because a transmitter is a complex device, a referencing system for unique identification of component
parts reduces the chaotic situation that would otherwise result from the natural numbering system found in
every parts list, in which the first capacitor is designated C1 and the first resistor is likewise designated R1,
but when several assemblies using capacitors or resistors appear together, the entire question then
becomes "which C1 or R1 are we talking about?"
The LARCAN prefixing system and its "undocumented features" represent a beginning and evolving
solution to some of these problems. It begins by assigning a distinct assembly prefix number to each
subassembly.
Prefix 2, the amplifier chassis assembly, has other subassemblies, which are uniquely prefixed such as
the metering board, which is prefixed 4. This sub assembly could have a C1, an R1, etc. Identification of
each component in full is done by simply adding the prefix number to the component designator, thus 4C1,
4R1, etc.
Prefix designation is great for written communications such as letter or FAX, but when talking about it
during a phone conversation, it is probably more natural to simply say "C1 in the preamp board" or "R7 in
the output amplifier" than to go through the routine of looking up the prefix number.
TSM 20-308 rev 1: April 3, 2000
100 W UHF Amplifier
MX100U Series - 100 Watt UHF AMPLIFIER
GENERAL SERVICE INFORMATION
4.
List of Assembly Prefixes
PREFIX 1
Main Power Supply Chassis Assembly
Sub-assembly prefix 1PS1 +12VDC Control power supply
Sub-assembly prefix 2 Control Board
PREFIX 2
Main Amplifier Chassis Assembly
Sub-assembly prefix 3 Status Display Board
“
“ 4 Metering Board
“
“ 5 Voltage Regulator
“
“ 6 Front End Module
“
“ 7 IPA1 Module
“
“ 8 IPA2 Module
Sub-assembly prefix 9A, 9B PA Modules
5.
Production Changes
From time to time, it may become necessary that changes be made in the equipment described in this
manual. Such changes are usually made either to provide improved performance, or to accommodate
component substitutions necessitated by vendor product availability. A revision letter or number may
follow the model or group number marked on the nameplate, chassis, or circuit board; or on the parts list
(where it is an "R" followed by a dash and a number). Whenever a revision letter or number appears, it
should be quoted in any correspondence or communication regarding the equipment.
TSM 20-308 rev 1: April 3, 2000
100 W UHF Amplifier
MX100 Series - 100 Watt UHF AMPLIFIER
GENERAL DESCRIPTION
INTRODUCTION
This manual describes the LARCAN 100 watt UHF amplifier which is designed to operate on channels 14
through 69. This solid state 100 W UHF amplifier was designed to operate conservatively at 100W peak
sync visual RF power, and 10W average aural carrier RF power, with superb performance, reliability and
operating economy. This amplifier accepts an on-channel internally diplexed (in a 10:1 ratio vis to aur)
composite driving signal of about 10mW peak visual RF as input to its RF chain.
The 100W amplifier and channel processor chassis’ are designed to fit in a single 19" customer-provided
cabinet rack, and require 15.75" (9RU) of vertical panel space for a complete transmitter or translator
system. Alternatively, a 19" customer-provided tabletop cabinet could be substituted if the site requires it.
The RF amplifier heatsink has its own integral cooling fans, and other sub-assemblies are convection
cooled. The simplicity of design, the deployment of all modular and other subassemblies, and the use of
standard readily available components, also enhances serviceability.
Peak forward and reflected power are displayed on an analog percent power meter located on the front
panel of the amplifier unit.
AMPLIFIER CHAIN
The internally diplexed composite RF output of the channel processor or exciter is fed to a conservatively
designed broadband solid-state Front-End amplifier. This amplifier requires no tuning or adjustment.
Simplicity of operation, reduced maintenance costs and increased reliability are a few of the major benefits
derived from this amplifier.
The amplifier chain consists of four stages of amplification. These are the Front End, IPA1, IPA2 and PA
stages. The first two stages operate in class A and the last two in class AB. The overall gain of the system
is about 42dB.
The Front-End module acts as a pre-amplifier as well as an RF level control of the RF chain. It accepts
control voltages from the AGC and VSWR cutback circuits for maintaining and power cutback purposes
respectively. The 100W transmitter uses a single RF chain, consequently quadrature phasing and
combining are not needed, however, if the need arises the Front End module also has gain and
quadrature phasing controls that can be made available.
The next stage is the IPA1 module. It is based on the MRF181 transistor. This broadband amplifier
delivers about 1W sync peak to the IPA2 module. This amplifier does not require optimizing in the system,
which means that it is not frequency dependent at the RF level it is operating.
The IPA2 and PA modules are functionally identical modules. Physically, the only difference is that the
IPA2 module has input and output SMA connectors, and the PA modules do not. Under RF operation the
bias on both IPA2 and PA modules are adjusted to optimize the overall intermodulation products and
differential gain.
TRANSMITTER CONTROL
Interlocking in the 100W simply consists of a jumper as a default connection. The terminals are marked
INTRLK on 1TB1. Antenna or dummy load interlock can be substituted for this jumper.
All control wiring of the transmitter passes through a control circuit board (prefix 2 of the P/S chassis), and
facilities can be provided on this board for telemetry, status, and control connections to and from a remote
control system.
A thermostat is provided in the PA heatsink to open the interlock chain and shut down the power supply
TSM 20-308 rev 1: April 3, 2000
100 W UHF Amplifier
MX100 Series - 100 Watt UHF AMPLIFIER
GENERAL DESCRIPTION
should an unlikely overheating condition occur.
The amplifier chassis requires 120VAC and+35Vdc. They come from the power supply chassis assembly.
In the amplifier chassis, this +35Vdc is fed to a dual regulator board which supplies regulated +28Vdc to
the amplifier modules. The amplifier cooling fans requires the 120Vac.
The control's 12Vdc linear power supply is rated for 0.9A and is powered upon closing of the power supply
`POWER’ circuit breaker.
TSM 20-308 rev 1: April 3, 2000
10
100 W UHF Amplifier
MX100 Series - 100 Watt UHF AMPLIFIER
GENERAL DESCRIPTION
ELECTRICAL AND MECHANICAL SPECIFICATIONS
NTSC
Power Output: ................................................................................................ Visual 100 W peak, Aural 10W
Diplexing: ......................................................................................................................internally, 10:1 V to A
Frequency Range: ................................................................................. 470-806 MHz (channels 14 thru 69)
Amplifier Output Impedance: .................................................................................................................. 50 Ω
Output Connector: ............................................................................................................................... type N
Amplifier Input Impedance: ..................................................................................................................... 50 Ω
Output Regulation: ................................................................................................... 3% (black-white picture)
Output Variation: ................................................................................................................ 2% (over 1 frame)
Amplitude/Frequency Response
-0.75 MHz to +4.75 MHz (Relative to Visual Carrier) .................................................................. +0.5/-1.0 dB
Harmonic Radiation: ............................................................................................................................ -60 dB
Spurious Emission (fv-4.5MHz, fv+9.0 MHz) without a Bandpass Filter: ............................................ -30 dB
Intermodulation Distortion:.................................................................................................................... -50 dB
ELECTRICAL AND MECHANICAL SPECIFICATIONS
ELECTRICAL
AC Line Input: ................................................................................................................................... 120VAC
Power Consumption, black picture + 10% aural: ................................................................... 920VA (typical)
ENVIRONMENTAL
Ambient Temperature: ...............................................................................................................0°C to +45°C
Humidity: ....................................................................................................................................... 0% to 90%
Altitude: ...............................................................................................................................................7500 ft.
COOLING
Two 4” muffin fans push air into the heatsink and through the front panel perforations.
DIMENSIONS
The Amplifier, Power Supply, and Channel Processor chassis’ are standard 19" rack wide units;
Height: Amplifier= 7" (4U); P/S=7” (4RU); Ch. Processor=1.75” (1RU); TOTAL HEIGHT=15.75” (9RU)
Depth is 19" including a 3" allowance for connectors.
The MX100U series amplifier is marketed on the assumption that the customer prefers to provide the
cabinet or enclosure for it.
SHIPPING WEIGHT
Combined weight of Power Supply and Amplifier:……………………………….………Approximately 100
lbs.
TSM 20-308 rev 1: April 3, 2000
11
100 W UHF Amplifier
MX100 Series - 100 Watt UHF AMPLIFIER
GENERAL DESCRIPTION
ABOUT THIS MANUAL
It will be observed that this manual consists of a collection of separate publications, each one of which
describes its own module or section of the equipment. Parts lists, applicable alignment instructions, and
illustrations which generally consist of assembly diagrams and schematics are included in each of these
booklets, which are identified by a "PUB" number and revision.
These mini-publications represent our attempt to assure quality of our documentation and at the same
time maintain the material as current as possible. In the usual large manual or handbook, a change made
to a single module might require a sentence or even several paragraphs be added, with the result that all
text following the change will shift, consequently requiring renumbering of all pages and subsequent
reprinting. These operations create an undesirable delay between the release of the revision to the
equipment and the re-issue of its manual, despite our extensive use of computers. It is our hope that this
republication delay will be reduced because revisions are nearly always done on one module at a time,
and a few pages pertinent to one module are obviously simpler to revise and reprint than the many pages
of a handbook.
Each section or module of the equipment is described in its own booklet. For each booklet, the format
generally consists of a block diagram where applicable, then the relevant specifications, then the circuits
are described, then test/alignment procedures are defined, and then the parts list is presented. Finally, the
Figures (illustration drawings in 11" x 17" size) complete the booklet.
The Parts Lists in all booklets have been compiled by, and then extracted from, the LARCAN materials
management computer system, and are current as of the date of issue of the booklet.
We have attempted to present our circuit descriptions in such a way that they would be meaningful to the
competent technician whose main objective is to look after the equipment. We have therefore minimized
the inclusion of material usually found in engineering textbooks, professional papers, and doctoral theses,
because much of the information from such sources, although meaningful to the EE, can be too heavy and
overdone for the beleaguered technician who is desperately trying to put a transmitter back on the air.
3-ring binders are used for LARCAN manuals as a courtesy to our customers because a 3-ring binder
enables assembly drawings and/or equipment schematics to be temporarily extracted and used in a more
convenient place when necessary. (Before their joining LARCAN, several of our staff technical people
were previously broadcast station engineering technicians, whose custom was to temporarily tape their
schematics to the transmitter cabinet doors for convenient reference when working inside the equipment).
Drawings whose numbers begin with 30C, 31C, 40D, 41D, 50E, or 51E may have been reduced in size or
even split into several sheets to fit into the booklet's 11" x 17" format. Should any reduced drawings as
presented in our manuals be found difficult to read, full size engineering blueprints are available at no
charge by simply writing, calling or FAXing our Customer Service department and requesting the
referenced drawing and revision wanted.
LARCAN INC.
228 Ambassador Drive,
Mississauga, Ontario, Canada L5T 2J2
Phone (905)-564-9222; FAX (905)-564-9244.
TSM 20-308 rev 1: April 3, 2000
12
100 W UHF Amplifier
MX100 Series - 100 Watt UHF AMPLIFIER
GENERAL DESCRIPTION
Notes:
TSM 20-308 rev 1: April 3, 2000
13
100 W UHF Amplifier

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2002:02:19 10:17:04-05:00
Create Date                     : 2002:02:19 10:11:13-05:00
Page Count                      : 14
Creation Date                   : 2002:02:19 10:11:13-05:00
Mod Date                        : 2002:02:19 10:17:04-05:00
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : ramejia
Metadata Date                   : 2002:02:19 10:17:04-05:00
Creator                         : ramejia
Page Mode                       : UseNone
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BZ5MX100U

Navigation menu