GENERAL DESCRIPTION
OVERVIEW
The LARCAN model TTS250M solid-state VHF translator has been designed to
operate conservatively at 250W peak sync visual power, and 25W average aural power.
The translator is completely housed in a 52” high cabinet using standard 19” EIA panels.
The translator is designed for operation from nominal 230V single phase 60Hz
power. Transformer taps are provided to adjust the amplifier power supply for on-site
nominal voltages between 200V and 240V.
AMPLIFIER
The amplifier design is similar to that employed in LARCAN’s high power model
‘M’ series transmitters. The RF amplifier is located in a self-contained slide out drawer.
The power output stage use a pair of dual FET RF power transistors operating Class
‘AB’. Strip line power splitters and combiners are used at the input and output
respectively.
Cooling is provided by a squirrel cage type blower mounted on the rear of the
slide out drawer. Air is drawn through a filter in the rear door of the cabinet, blown
through the amplifier heatsink and exhausted through a grill at the front of the amplifier.
No provision is made for ducting exhaust air.
Metering is provided for voltage, current and RF power. The amplifier is VSWR
protected with an automatic cutback circuit.
The power supply is a conventional linear design, with regulators located in the
amplifier drawer.
All individual assemblies are modular in design, and easy to access for
maintenance and testing. Full interlocking and telemetry facilities are provided.
CIRCUIT DESCRIPTION AND SET UP PROCEDURE
PRE-CORRECTION
The pre-correction circuit used by the amplifier has been set up at the factory and
should not require re-adjustment. Technical personnel should be aware that any
adjustments performed on these circuits should be slight and may have to be repeated
until the desired correction is achieved.
Pre-corrector
The Pre-correction board comprises three separate sections: an input attenuator, a
phase corrector and an output amplifier. The input attenuator is made up of R1 through
R3. The adjustable phase corrector comprises L1, CR1, and R4. U1 is an amplifier IC
and receives power from voltage regulator U2. The amount of correction is controlled by
the adjustment of L1. Typically the adjustment is set to correct for the amount of
differential phase introduced by the PA stages and this should correspond to
approximately unity gain through the Pre-correction board.
Linearity Corrector
The Linearity Corrector board provides a slight amount of linearity correction
needed for intermodulation distortion in the PA stages. R2 and C2 control the amount of
correction by allowing the signal to be shunted to ground by diodes CR1 and CR2. A
higher level signal will cause the diodes to conduct more, shunting more signal to ground.
R3 acts as a fine control by varying the bias on CR1 and CR2 through emitter follower
Q1.
IPA MODULE
CIRCUIT DESCRIPTION
The amplifier consists of two stages of amplification, a linear hybrid IC and a
transistor power stage. Both stages are biased for Class A operation and each has its own
set of three terminal regulators for voltage or current regulation.
The signal is first applied to a form of variable attenuator consisting of R2, R6
and R12. The first stage of amplification is a CA2842 hybrid IC; this amplifier provides
approximately 22dB of gain. A coaxial cable jumper is provided between this stage and
the next to allow for troubleshooting.
The second stage of amplification is a Class A biased MRF325 transistor
amplifier. The input section consists of an attenuator/matching network to transform the
50ohm impedance to values needed for optimum transistor performance. Similarly, a
matching network at the output of the transistor provides the impedance match to the
50ohm output. C6 and C19 are DC blocking capacitors at the input and output of the
amplifier respectively.
DC power to the hybrid stage is provided by a three terminal voltage regulator IC
(VR1). This serves to remove hum from the power supply as well as provide an
interlocking circuit for other applications. This interlocking function is not used in the
250W amplifier application and thus E2 should have a jumper to ground. The DC power
to the output stage is also provided by a three terminal voltage regulator. VR2 is
configured as a 1.5A constant current source. The current is set by the voltage drop
across R11. The zener diode VR3 will conduct at approximately 22V and forward bias
the transistor.
Set up Procedure
•
•
•
•
•
•
Set up a power supply to 30V; current limited to 3.5A.
Connect the power supply to E1 of the IPA. The current drawn should be
approximately 1.75A.
Remove the coax jumper.
Apply a sweep signal to the preamplifier input, being careful not to
overdrive the test equipment. The gain should be at least 18dB to 20dB
and the return loss better than 15dB in the frequency range of interest.
Connect a 30dB attenuator to the output of the amplifier.
Apply a low level sweep to the amplifier and measure the gain (be sure to
take into account the 30dB pad). Gain should be about 13dB to 14dB.
POWER AMPLIFIER MODULE
CIRCUIT DESCRIPTION
The PA modules used in the 250W amplifier employ dual FET RF transistor
packages in push-pull configuration. The transistors operate Class AB and are biased for
0.6A static drain current per transistor.
The input to the PA module is applied at J1 from the power splitter board.
Transformer T1 divides the input into two equal and opposite signals. Capacitors C3, C4
and the associated strip line circuitry form an impedance matching network to the gates
of the FETs. C1 and C2 are DC isolation (blocking) capacitors. Capacitors C13 and C16
and associated strip line inductors form an output impedance matching network and T2
combines the out of phase signals at the output J2. C14 and C15 also act as blocking
capacitors.
The 50V DC supply is connected to each drain through the 5A fuses and
decoupling inductors L4 and L5. Two resistive divider networks comprising R1 through
R10 apply gate bias voltage to the FETs to set the static drain current. Zener diodes CR1
and CR2 provide a constant voltage source +20V for the bias voltage adjustment. The
FET gate bias required for the recommended 0.6A of quiescent drain current may be
anywhere between 2V and 5V depending on the individual FET. Capacitors C6, C7, C9
through C12, C17 and C18 are RF bypass capacitors.
Set up Procedure
•
•
•
Set up a 50V power supply; current limited to 1.2A.
Turn both bias potentiometers for maximum resistance.
Apply the supply to the one transistor at a time (one- half package) and
adjust the corresponding bias resistor for 0.6A drain current. This setting
•
•
•
is a starting value. It will be re-adjusted during test for minimum
intermods and FM noise.
Connect a 30dB, 20W attenuator to the output of the amplifier.
Apply B+ to both supply connections of the amplifier module.
Apply a low level sweep to the module and measure the gain (be sure to
take into account the 30dB pad). Gain should be about 21dB to 24dB.
VOLTAGE REGULATOR BOARD
CIRCUIT DESCRIPTION
The Voltage Regulator board comprises two identical regulator circuits. One is
described below; the description for the second is the same except for the component
numbers.
The voltage regulated is based on a monolithic regulator IC MC1723CP and a
pass transistor for current handling capability. The regulator IC compares a sample of the
output voltage to an on-chip reference. The sample is applied to pin 4 through a resistive
divider consisting of R7, R9 and R11. Varying R7 changes this sample thus changing the
output voltage. The output of the IC (pin 10) drives the PNP transistor U2 through a
Darlington transistor Q3.
Short circuit protection is provided by Q1 and Q4. Q4 shunts the drive away from
the base of U2 when the output current causes the voltage across R6 and R10 to rise high
enough to open transistor Q1. Supply voltage for the IC is via R8 and CR3 from the 30V
supply.
Metering outputs are provided for the supply as well as those for current drawn
from each regulator and the total current from the 30V supply. The voltage metering
outputs have calibration pots whereas the current metering outputs are preset with fixed
resistors.
Set up Procedures
•
•
•
•
•
Set up one power supply for 65V; current limited to 1A and another
supply for approximately 30V, also current limited to 1A.
Apply the voltages to the appropriate inputs, 65V to E1 and E13; 30V
to E12.
Adjust R7 for a voltage of 50V at E4. Adjust R24 for 50V at E16.
Check for 30V output at E11 (the same as that applied to E12).
Reset the 65V supply current limit to approximately 7A, and apply
sufficient load (to draw approximately 5A at 50V) to E4 and to E16
alternately, to check the regulation of the supply. The output at either
one should not drop more than 1V under load.
OVER-VOLTAGE PROTECTION BOARD
CIRCUIT DESCRIPTION
The Over-voltage Protection board consists of an op-amp comparator U2 which
compares the incoming raw supply voltage to a reference voltage set up by CR1. The
input to the comparator is adjustable via R2. If the input voltage rises above the
reference level, the output of the comparator drops to a low value, which lights CR2, an
on-board LED. The output of the op-amp is OR-ed with the amplifier’s muting input,
using diodes CR3 and CR4 so that if an over-voltage condition occurs, the drive to the
amplifiers would be greatly decreased thus reducing the load on the regulator pass
transistors (thereby cutting the power dissipation of these devices).
Set up Procedure
•
•
•
•
•
Set up a variable power supply to current limit at 1A or less.
Apply a voltage of 30V to pin 11 and a voltage of 67V (3% above
nominal) to pin 8 of the Over- voltage board. For installations in
sites where incoming line voltage regulation is poor (i.e. -15% /
+10%), set the pin 8 voltage at 71.5V which is 10% above
nominal.
Adjust R2 until the LED illuminates.
Important: Ensure that the primary taps on the power transformer
are set as near as possible to the nominal on-site line voltage. Of
course the system will operate with other tap settings, but the range
in which it will work will no longer be as wide. Taps are provided
for 200, 208, 220, 230 and 242 VAC.
Once the nominal voltage has been established and appropriate
primary tap selected, the raw DC input to the regulator measur ed at
the 20A fuse 7F1, should read about 65V, not 55V as shown on the
drawing in Figure 10. We regret the error.
This over-voltage setting procedure is not expected to compromise the reliability
of the regulator components under otherwise normal operating conditions within a 15% /
+10% line voltage range. It is suggested that if and when the power source regulation is
improved, R2 setting could then be decreased to a level appropriate to the improved
upward extreme in line voltage. Over-voltage settings in excess of +10% (71.5V) are not
recommended.
INPUT PIN ATTENUATOR
CIRCUIT DESCRIPTION
The Pin Attenuator board acts as a variable attenuator controlling the input level
to the preamplifier for AGC and cutback purposes. Operational amplifier U2B controls
the amount of attenuation in the circuit. Three inputs are summed at pin 6 from the
VSWR and AGC circuits and additionally from U2A which is a ‘mute’ type signal. R5
controls the threshold of control of these signals. The circuit configuration comprising
CR1, CR2 and CR3 form a matched attenuator, biased by the output of U2B, R2, R3, R7
and R8. As the output of U2B rises, the attenuation of the circuit decreases, thus
increasing the RF output as J2.
METERING BOARD
CIRCUIT DESCRIPTION
The Metering board detects forward and reflected power levels and processes
these signals to provide outputs for metering, telemetry, AGC and VSWR protection.
The forward and reflected power detectors are ‘visual only’ detectors. The
description that fo llows is for the forward detector portion only; the ‘reflected’ detector is
identical. CR1 and Q1 form a basic detector circuit and C3, C4 and L1 trap out the
4.5MHz aural components. CR3 and C7 act as a peak detector providing the buffer
circuit of U1 with a peak-level voltage.
The outputs of the peak detectors are applied to operational amplifiers U1B and
U2B which have a zeroing function and provide the drive for the metering circuit and
telemetry. These amplifiers also drive the AGC and VSWR circuits. Operation
amplifiers U1A and U2A compare the forward and reflected signals to preset levels and
provide an error signal to the Pin Attenuator board. An additional circuit consisting of
U3 acts as a comparator to drive an LED on the indicator board as the VSWR signal rises
about the preset level.
Set up Procedure for Metering, VSWR and AGC Circuits
•
•
•
•
•
•
•
Set the AGC/MAN Switch on the front panel to the MAN position.
Terminate the output of the amplifier into a suitable 50ohm load through a
thru- line wattmeter or equivalent.
Turn the visual and aural carrier switches on the exciter to the OFF
position.
Apply DC power to the amplifier. The blower should come on. There
should be no output power indication.
Turn the metering switch to the 35V position. Measure the voltage at E12
on the Regulator board and adjust R34 for a corresponding front panel
reading on the lower meter scale.
Turn the metering switch to the 50V position. Measure the voltage at E13
on the Regulator board and adjust R37 for a corresponding front panel
reading on the lower meter scale.
Turn the metering switch to the FWD position and adjust R18 on the
metering board for a zero reading on the front panel meter. This should
also correspond to a minimum voltage at TP1. Repeat this procedure for
the RFL position, R2 and TP2.
•
•
•
•
•
•
Turn the visual carrier switch on the exciter to the ON position. Slowly
bring the transmitter up to operating power.
Turn R33 on the Pin Attenuator board for maximum power out then trim it
back so the power just starts to drop (about 10%). Reset the output power.
Adjust R32 on the Metering board for a 100% meter reading in the FWD
position.
Reverse the connections at J1 and J2 on the Metering board. Adjust R36
for maximum power output. Adjust R30 for a 100% RFL meter reading.
Re-adjust R36 for a 15% reduction in power. Adjust R42 until the VSWR
LED just starts to illuminate. Trim R36 for about 15% power output.
Restore the original connections to J1 and J2. The VSWR cutback circuit
is now set.
Set the AGC/MAN Switch to the AGC position. The power output level
should be adjustable via the front panel AGC potentiometer.
POWER SUPPLY AND CONTROL
CIRCUIT DESCRIPTION
The power supply consists of a center tapped transformer, bridge rectifier and two
choke input filters. The supply has dual outputs of 65V and 30V. The AC is fed to the
supply through 6TB1, routed through the breaker 8CB1, located on the front panel of the
transmitter, and to contactor 6K1. From this contactor AC is fed to the transformer of the
power supply as well as to 6F1 and 6F2 in line with the amplifier blower. The contactor
is energized by a solid state relay 6Z1. Interlocks are provided for the amplifier thermal
cutout as well as an auxiliary interlock for customer interface. The 12V from the exciter
is applied through the REMOTE/LOCAL Switch directly in the LOCAL position, or
when in the REMOTE position, through the exciter’s VOR contacts or other remote
control device.
Some transmitters may be equipped with an optional ON/OFF Time Delay board
for remote control. These transmitters use the exciter VOR contacts for remote
operation. One side of the VOR contacts is energized by 8S1 in the REMOTE position.
When video is applied to the exciter the contacts close, applying +12V to 6Z3 and TB1-1.
Capacitor C1 on the Time Delay board charges through CR1, R3 and R5 at a preset rate
determined by R3. When the voltage reaches 6V, U1 will on Q1 thus energizing the
relay coil of K1, turning on the transmitter. When video is removed, C1 discharges at a
preset rate determined by R4, turning off the transmitter. The Time Delay board function
can be bypassed via S1.
TELEMETRY
CIRCUIT DESCRIPTION
The transmitter is equipped with an Interface board for remote telemetry of power
supply voltages, output power and thermal cutout switch status. The thermal switch
status is field selectable; either a normally open or a normally closed set of contacts.
Amplifier telemetry connections are listed in the table on the following page.
FUNCTION
CONNECTION
AUX INTERLOCK
6TB3-2
REMOTE CONTROL
6TB3-3
REMOTE TELEMETRY 65V SUPPLY
6Z2-TB1-6
REMOTE TELEMETRY 30V SUPPLY
6Z2-TB1-5
REMOTE TELEMETRY FWD POWER
6Z2-TB1-4
THERMAL CUTOUT STATUS
6Z2-TB1-1
6Z2-TB1-2
AC LINE INPUT POWER
6TB1-1
6TB1-2
NEUTRAL
6TB1-3


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 16
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:25e4f79d-8482-41b0-9b78-c508cc6fb723
Producer                        : Acrobat PDFWriter 4.0 for Windows
Modify Date                     : 2004:07:21 10:34:18-04:00
Create Date                     : 2003:06:19 15:25:42Z
Creator Tool                    : tts250.manual - Microsoft Word
Metadata Date                   : 2004:07:21 10:34:18-04:00
Document ID                     : uuid:3c094d7a-c23b-43c5-97eb-d462c3331838
Format                          : application/pdf
Title                           : tts250mv
Creator                         : tts250.manual - Microsoft Word
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BZ5TTS250MV

Navigation menu