Latitude 714 HEART RATE CHEST STRAP User Manual

Latitude Limited HEART RATE CHEST STRAP

User Manual

Download: Latitude 714 HEART RATE CHEST STRAP User Manual
Mirror Download [FCC.gov]Latitude 714 HEART RATE CHEST STRAP User Manual
Document ID1780779
Application IDXFEW2ZnPbjik8TKVv9sRbg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize50.89kB (636165 bits)
Date Submitted2012-08-31 00:00:00
Date Available2012-08-31 00:00:00
Creation Date2012-08-09 15:35:21
Producing SoftwareAdobe PDF library 10.01
Document Lastmod2012-08-14 18:17:29
Document TitleART120256 bluetooth heart rate sensor manualp4_amend
Document CreatorAdobe Illustrator CS6 (Windows)

Bluetooth Chest Strap Heart Rate Sensor : Instruction Manual
A93806
ART12-0256
Project no:MKT12023
Prepared by: Grace Copyright: Latitude Limited
90 mm
75 mm
90 mm
Date: 07 Aug 2012
saddle wire
Size :90 x 75 mm
Type: book type
Cover page : 4 pages
Body: 8 pages
Total page : 12 pages
color: 1C+1C (Black)
paper: 100 gsm white wood free paper
Binding: Saddle wire
Paper: Wood free paper
Paper weight: 100 gsm
folding line
Prepared by:
Checked by:
Approved by:
Date:
Date:
Date:
Bluetooth Chest Strap
Heart Rate Sensor
Instruction
Manual
Back Cover
Front Cover
A. Introduction:
A-01
A. Introduction:
A-02
WARNING!
Make sure that fully understand the functions and limitations of
this product before using it.
Consult a doctor or trainer for setting the zone prior to undergo
an serious Cardio-fitness training.
This product is an supplementary device for heart rate
measurement, and it is NOT a substitute for getting the heart
rate reading from a doctor.
If the heart rate condition is in doubt, consult your doctor.
Thank you for purchasing this Bluetooth Chest Belt Heart Rate Sensor.
This product enables training in a group without interference from other heart
rate sensors.
A. Introduction:
A-03
FCC Compliance Statement
(For US)
Avoid exposing the product to the extreme conditions.
Avoid rough uses or severe impacts to the product.
A. Introduction:
A-04
CARE
MAINTENANCE
- This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
This device must accept any interference received, including interference that may
cause undesirable operation.
This heart rate sensor is a high-tech instrument that should be handled with care.
Follow the caring instructions to ensure reliable measurement and to maximize
the life span of the heart rate sensor. It is advisable to use the unit and the chest
strap in conformity with the following instructions:
- WARNING: Changes or modifications to this watch not expressly approved by
the party responsible for compliance could void the user’s right to operate the
equipment.
Connector: Detach the connector from the strap after every use and dry it with a
soft towel. Clean the connector with a mild soap and water solution
when needed. Never use alcohol or any abrasive material such as
steel wool or cleaning chemicals.
- NOTE: This equipment has been tested and found to comply with the limits for
a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and radiates radio
frequency energy. If it is not installed and used in accordance with the
instructions, it may cause harmful interference to radio communications.
- However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
recommended to reduce the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation space between the watch and the receiver.
- Consult the dealer or an experienced radio/TV technician for help.
Strap: Rinse the strap under running water after every use and hang to dry. Clean
the strap gently with a mild soap and water solution when needed. Do not
use moisturising soaps as they can leave reside on the strap. Do not soak,
iron, dry clean or bleach the strap. Do not stretch the strap or bend the
electrode areas sharply.
Dry and store the strap and the connector separately to maximize the heart rate
sensor battery lifetime. Keep the heart rate sensor in a cool and dry place. Do not
store the heart rate sensor wet in non-breathing material, such as a sports bag,
to prevent snap oxidation. Do not expose the heart rate sensor to direct sunlight
for extended periods.
Remove the battery from the battery case when the unit or the chest strap WILL
NOT be used for a long time.
A. Introduction:
A-05
B. Setting Up:
B-01
Wear the Heart Rate Sensor:
Naming of the parts:
This product includes 2 parts:
1 Chest Strap
Chest Strap: To be tied around the body
Electrode areas
1 Moisten the electrode areas
of the strap.
2 Attach the connector to the
strap.
3 Adjust the strap length to fit
tightly but comfortably.
4 Tie the strap around your
chest just below the chest
muscles, and attach the
hook to the other end of the
strap.
5 Check that the moist
electrode areas are firmly
against your skin and that
the logo of the connector is
in a central and upright
position.
NOTE:
Detach the connector
from the strap and rinse
the strap under running
water after every use.
Sweat and moisture may
keep the electrodes wet
and
the
transmitter
activated. This will reduce
the transmitter battery life.
Connector: To send the heart rate
signal to the receiving
device.
Electrode areas: To detect heart rate.
Hook: To fix the strap on user’s chest
Hook
Buttons: To attach the connector to the
strap
2 Connector
Buttons
Battery door: To cover the battery
compartment
P E
Battery door
B-02
Getting Started:
The heart rate sensor is compatible with Bluetooth® smart and Bluetooth® smart
ready devices. It may require a separate application to view heart rate data on the
receiving device, such as a watch or a mobile phone.
Pair the heart rate sensor with the receiving device when using it for the first time.
B. Setting Up:
B-03
Batteries:
All connectors have user changeable batteries. To change the battery yourself, follow
the instructions below, and see the markings on the connector.
1 Turn the cover counterclockwise with a coin gently
until it pops out.
2a
32
20
32
32
Make sure the battery
is placed under the
golden slot.
CR
CR20
CR20
Keep the receiving device in front of you to ensure sufficient transmission range from
the heart rate sensor to your device, such as in a front pocket or fixed on a belt.
2b
P E
3 Press the cover back into
the connector.
4 Turn the cover clockwise
with the coin again until the
little arrow pointed to the dot.
32
CR20
O P
DO NOT wear the receiving device on your back, such as in a back pocket or
backpack.
2 Remove the exhausted
battery and insert a new one
(CR2032) with (-) side
against the metal contact.
P E
B. Setting Up:
Back
Front
NOTE: Keep batteries
away from children. If
swallowed, contact a
doctor immediately.
CAUTION:
Risk
of
explosion if battery is
replaced by an incorrect
type.
Operating temperature : -10°C to +50°C
*** CAUTION
Battery Safety Information
Exhausted batteries are to be removed
Do not dispose of product or batteries in fire; batteries may explode or leak
If this product will not be used for an extended period of time, remove the
batteries from the product
The supply terminals are not to be short-circuited
Batteries are to be inserted with correct polarity
Clean the battery contacts and also those of the product prior to battery installation
As always, dispose of batteries in an eco-friendly manner
This product is compliant with Directives 1999/5/EC.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Create Date                     : 2012:08:09 15:35:21+08:00
Creator                         : Adobe Illustrator CS6 (Windows)
Modify Date                     : 2012:08:14 18:17:29+08:00
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Format                          : application/pdf
Title                           : ART120256 bluetooth heart rate sensor manualp4_amend
Metadata Date                   : 2012:08:09 15:35:21+08:00
Creator Tool                    : Adobe Illustrator CS6 (Windows)
Thumbnail Width                 : 84
Thumbnail Height                : 256
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 7596 bytes, use -b option to extract)
Instance ID                     : uuid:9163c469-ca40-48cf-a8aa-94d962566956
Document ID                     : xmp.did:EA6B177BF4E1E111991280379641E929
Original Document ID            : uuid:5D20892493BFDB11914A8590D31508C8
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:775b7e73-b36f-4bbc-8e33-34db071613e5
Derived From Document ID        : xmp.did:619EDB9015E1E111BCA7B8D79A2A6125
Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved
History Instance ID             : xmp.iid:1C03346747E0E111AB809DF6245E9E3F, xmp.iid:EA6B177BF4E1E111991280379641E929
History When                    : 2012:08:07 12:21:47+08:00, 2012:08:09 15:35:11+08:00
History Software Agent          : Adobe Illustrator CS5, Adobe Illustrator CS6 (Windows)
History Changed                 : /, /
Manifest Link Form              : EmbedByReference
Manifest Reference File Path    : F:\Grace\Project\ART12-0256_Heart rate chest strap manual\cover photo.jpg
Startup Profile                 : Print
Has Visible Overprint           : True
Has Visible Transparency        : False
N Pages                         : 1
Max Page Size W                 : 297.000476
Max Page Size H                 : 209.999929
Max Page Size Unit              : Millimeters
Font Name                       : ArialMT, Arial-BoldMT, Arial-BoldItalicMT, Arial-Black, MyriadPro-Regular, MingLiU, LucidaSans
Font Family                     : Arial, Arial, Arial, Arial, Myriad Pro, 細明體, LucidaSans
Font Face                       : Regular, Bold, Bold Italic, Black, Regular, Regular
Font Type                       : Open Type, Open Type, Open Type, Open Type, Open Type, TrueType, Unknown
Font Version                    : Version 5.10, Version 5.08, Version 5.08, Version 5.06, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, Version 7.00, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168
Font Composite                  : False, False, False, False, False, False, False
Font File Name                  : arial.ttf, arialbd.ttf, arialbi.ttf, ariblk.ttf, MyriadPro-Regular.otf, mingliu.ttc, MyriadPro-Regular.otf
Plate Names                     : Cyan, Magenta, Yellow, Black, PANTONE 286 CVU
Swatch Groups Colorants Tint    : 100.000000
Swatch Groups Group Name        : Brights
Swatch Groups Group Type        : 1
Swatch Groups Colorants Swatch Name: C=60 M=90 Y=0 K=0
Swatch Groups Colorants Mode    : CMYK
Swatch Groups Colorants Type    : PROCESS
Swatch Groups Colorants Cyan    : 60.000004
Swatch Groups Colorants Magenta : 90.000000
Swatch Groups Colorants Yellow  : 0.003099
Swatch Groups Colorants Black   : 0.003099
Producer                        : Adobe PDF library 10.01
Page Count                      : 5
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WM4714