Lee Technology Korea LTK-2000M MULTICALL CHARGER PAGING SYSTEM User Manual

Lee Technology Korea Co., Ltd. MULTICALL CHARGER PAGING SYSTEM Users Manual

Contents

Users Manual

    Multicall Charger Paging System User Manual (Manual Ver. 1.00)             LEE TECHNOLOGY KOREA CO., LTD. email sales@leetek.org website www.leetekorea.com       KOREA HEADQUARTER                                                     US OFFICE 3rd FL. #499-2, Sang3-dong,                                     6040 Unity Drive Suite L, Wonmi-gu, Pucheon-city,                                       Norcross, GA30071, U.S.A Kyunggi-do, Korea tel +82-32-324-9838                                               tel +1-678-218-0990 fax +82-32-324-9840                                              fax +1-678-218-0991 Multicall Paging System                                                  User  Manual
                                   Multicall Paging System                                                  User  Manual NOTICE This manual, software and electronic circuitry are copyrighted. All rights reserved. Under the copyright laws, this manual, software and electronic circuitry may not be copied, in whole or in part without written prior consent of Lee Technology. All information provided in this document is carefully prepared and offered in good faith as a guide in the installation, use and servicing of our products.  Installers  must  ensure  that  the  final  installation  operates satisfactorily within the relevant regulatory requirements.  Lee  Technology accepts no responsibility for incorrect installation. Lee Technology reserves the right to change products, specifications and installation data at any time without notice. Lee Technology makes certain limited warranties with respect to  defective  diskettes,  documentation  and  electronic  circuitry.  Please  see  the associated information contained on this page. LIMITED WARRANTY With respect to the physical documentation and physical electronic circuitry enclosed herein, Lee Technology warrants the same to be free of defects in materials and workmanship for a period of one year from  the  date  of  purchase.  In  the  event  of  notification  within  the  warranty period  of  defects  in  material  or  workmanship,  Lee  Technology  will replace the defective diskettes, documentation and electronic circuitry. The remedy for breach of this warranty shall be limited to replacement and shall not encompass any other damages including but not limited to loss of profit and special incidental, consequential, or other similar claims. Lee Technology Korea specifically disclaims all other warranties,  expressed  or  implied,  including  but  not  limited  to  implied  warranties  of merchantability and fitness for a particular purpose with respect to defects in the documentation and electronic circuitry and the program license granted herein, in particular, and without limiting operation of the program license with respect to any particular application, use or purpose.
 IMPORTANT SAFTEY INFORMATION RF EXPOSURE STATSURE STATEMENT Your Pager Transmitter contains a radio frequency transmitter. When the button is pushed the transmitter sends our RF singnals. CAUTION : To comply with FCC RF exposure compliance requirements, A separation distance of at least 8 inches(20Cm) must be maintained Between the antenna of this transmitter and all persons, during Normal operation. The antenna used for this transmitter must not be co- Located or operating in conjunction with any other antenna of transmitter. Unauthorized antennas, modifications, of attachments could damage the Transceiver and may violate FCC regulations.
  INSTRUCTION for Multicall Charger Transmitter                1. EASY INSTALLATION INSTRUCTION Step X  Lock the antenna to the right corner of the Multicall Transmitter.  (Fit over plug and twist left to lock antenna in place) Step  Y  Plug the Multicall Transmitter A/C adaptor into the Multicall Transmitter and then into a standard outlet. A surge protector is recommended. Step Z  If more than one charging base is used, connect base units with jump wires. Step  [  Insert the pagers on the chargers. A charging indicator will illuminates  to  indicate  charging.  Pager  will  be  fully charged in 2 hours.  2. SYSTEM SETTING  To  enter  programming  mode,  press  the  “SETUP”  button  and  enter  the  password  “1379”  followed  by  “ENTER”  If  the password is accepted, the display will show “use * to scroll to menu options” Use the “*/Menu” key to scroll through the several menu options or press “CANCEL” to exit the system setting menu. Multicall Paging System                                                  User  Manual ◈ Save Mode (Special Option)  With this feature, the transmitter can send a signal automatically, when a pager number is stored. z Enter the number (#1) of pager and press “ENTER” key. z Enter another number (#2) of pager and press “ENTER” key.
z Then, the transmitter will send signals for calling the pagers  (#1, #2) in regular sequence.  1. Set Current Time With this feature, you can setup current time into the Nexcall Transmitter. z At the “Set Current Time” menu, set the hour and then press “ENTER” key. z Set the minutes and press “ENTER” key. z Use “#/Select” key to select AM or PM z After  the  correct  time  is  set,  press  the  “ENTER”  or  “*/Menu”  key to return to the main menu or press the “CANCEL” key twice to exit the system setting menu.  2. Set Sleep Time  With this feature, you can turn off pagers at once automatically.   To turn this feature OFF z Press “#/Select” key to turn the feature “OFF” z Press “ENTER” to go back to the main menu.    To change the sleep time z Press “#/Select” key to turn the sleep time “ON” z Set the hour and then press “ENTER” key z Set the minutes and then press “ENTER” key z Use the “#/Select” key to select AM or PM z After  suitable  time  is  set,  press  the  “ENTER”  or  “*/Menu”  key  to  return  to  the  main  menu  or  press “CANCEL” key twice to exit the system setting menu.     Multicall Paging System                                                  User  Manual  3. Range Test  With this feature, you can find out how far your transmitter will cover. z Remove a couple of pagers from the charger base z At the range test menu, press “#/Select” key to turn range test “ON” z Press “ENTER” to start the range test. As soon as range test is activated you’ll notice the pagers flash once per every 10 seconds.   4. Pre Set Message
 With this feature, you can pre-set message used frequently. z At the Pre Set message menu, press “#/Select” key to turn Pre Set Message “ON” or “OFF” z After  Pre Set  Message  is set,  press  the  “ENTER”  or  “*/Menu”  key to return to the main menu or press “CANCEL” key twice to exit the system setting menu.  5. Pager Alert  With this feature, you can have the option of changing the way your pagers alert.  Be sure that all pagers are returned before performing this procedure.   To Change the alert mode of your pagers, follow these instructions: z Remove all the pagers from the charger base or unplug the power supply that is connected to the charger base. z At the “Set Pager Alert” menu, press “#/Select” key to scroll through the different alert options. z After making a selection, press “ENTER” key 3 times. After sending the message, the pagers will now respond with your new selected alert mode. z Return all the pagers to the charger base or plug the power supply. The pagers are ready to receive the page with its new alert mode.      Multicall Paging System                                                  User  Manual  6. Set Pager ID (IQ Charger Transmitter Only) With this feature, you can have the option of changing the IDs. To Change the ID (Base, Individual, etc) of your pagers, follow these instructions: z At the “RX Read Mode” menu, press “#/Select” key to scroll through the different  options.  (1. Base  Id,  2. S/N) z After making a selection, press “ENTER” key. Your pagers’ information (Base ID, or S/N) will be displayed on the LED display. z At the “RX Read Mode” menu, press “*/Menu” key to scroll through the different options. (1. Set indivi ID, 2. Set the same ID, 3. Set RX Base ID) z After making a selection, press “ENTER” key. You are now able to enter the setting values. z Press “ENTER” key to complete the setting.  7. Duty Alert  With this feature, you can enable your transmitter to send a page, at a preset time, to a certain pager to remind them of a duty
required of them. For example, a buzzer can receive a page every 3 minutes to remind him to check the restroom. You can assign up to 3 different groups to be duty alert pagers. To program the duty alert z At the “Duty Alert” menu, press “#/Select” key to turn the duty cycle “ON” and press the “ENTER” key z Enter the duty pager number and press “ENTER” key. z Enter the cycle time (in minutes) and press the “ENTER” key. z Enter the numeric message. z After setting the duty alert function, press “ENTER” z Display will show “Duty __ saved”       Multicall Paging System                                                  User  Manual  8. Out of Range  With this feature, the pagers will play a melody when taken out  of range  from  the transmitter  to  inform  the guest that they  are located “Out of Range” and will miss their page. The melody will only stop, when they return back within range.    Turning the Out of Range “ON” z Remove all the pagers from the charging unit or unplug the power supply that is connected to the charger base z At the “Out of Range” menu, press “#/Select” key to turn the Out of Range “ON” z Press “ENTER” key 3 times. After sending the signal, all the pagers will light up once to tell you that they received the new message    Turning the Out of Range “OFF” z Remove all the pagers from the charging unit or unplug the power supply that is connected to the charger base z At the “Out of Range” menu, press “#/Select” key to turn the Out of Range “OFF” z Press “ENTER” key 3 times. After sending the signal, all the pagers will light up once to tell you that they received the new message
 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS : (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. IQ TRANSCEIVER INSTRUCTION MANUAL  NOTE:      THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.      SUCH MODIFICATIONS COULD VOID THE USERS AUTHORITY TO OPERATE THE EQUIPMENT.  NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.    These limits are designed to provide       reasonable protection against harmful interference in a residential installation.    This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.    However, there is no guarantee that interference will not occur in a particular installation.    If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.