Leedarson Lighting 6APLVABA0 Z-Wave Smart Plug User Manual 8 17

LEEDARSON LIGHTING CO., LTD. Z-Wave Smart Plug 8 17

user manual 8.17

Download: Leedarson Lighting 6APLVABA0 Z-Wave Smart Plug User Manual 8 17
Mirror Download [FCC.gov]Leedarson Lighting 6APLVABA0 Z-Wave Smart Plug User Manual 8 17
Document ID3967939
Application IDZPaA+n03dskf0P/H94Rt+w==
Document Descriptionuser manual 8.17
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize36.61kB (457676 bits)
Date Submitted2018-08-19 00:00:00
Date Available2018-08-19 00:00:00
Creation Date2018-08-17 15:07:06
Producing SoftwareAdobe Acrobat Pro 9.0.0
Document Lastmod2018-08-17 15:07:06
Document Titleuser manual 8.17
Document CreatorAdobe Acrobat Pro 9.0.0
Document Author: powell

NA Smart Plug (Z-Wave)
User Guide
The plug turns your electrical appliances smart by enabling you to control them through the
smart home APP on your phone at or away from home. It also enables you to automatically
switch appliances on and off according to a programmable timer and measure the energy
consumption.
Feature list:
1) Supports 1xAC output.
2) AC output switch on/off by manual and/or Z-Wave command.
3) Led indicates the working status.
4) Supporting power meter.
5) Supporting repeater role.
6) Supporting firmware OTA.
1. PACKAGE CONTENTS
Smart Plug *1
Quick start guide*1
2. FAMILIARIZE YOURSELF WITH YOUR SMART PLUG
Smart Plug Layout
② &③
①
① Socket: Converts your traditional outlet and enables your plugged-in appliance to
become Smart and controllable with the App
② Button: Press once to switch on or off; press and hold to reset
③ Indicator Light: when the plug is operating, the light is blue; when the device is turned
off, the light changes to red
3. TECHNICAL SPECIFICATIONS
Power supply:
120V~±10%, 60Hz
Rated load current:
15A
Power consumption:
≤1W
1800W
Power output
Operational temperature:
0℃-40℃
Radio protocol:
Z-Wave
Radio frequency:
908.42MHz
Range:
About 40m indoors (depending
(US)
on building materials)
4. FUNCTIONS OF EACH BUTTON ACTION AND OPERATION
Smart Plug is included into a Z-Wave network:
Trigger
Description
Short press
one time
Change the state of Smart Plug’s load.
Short press 3
times within
1 second
1. Send Node Info frame.
2. Remove for exclusion
1. Insert the Smart Plug to power socket, the LED will follow the status
(on or off) of its load’s power level.
2. Set the Z-Wave network main controller into exclusion mode.
3. Short press z-button 3 times within 1 second.
4. The LED will blink fast until the exclusion is completed, then the LED
will keep on blinking slowly. Otherwise, the LED will keep on blink fast
for 35 seconds and then follow the status (on or off) of its load status.
Press and
Reset Smart Plug to factory Default:
hold for 5
seconds
1. Make sure that the Smart Plug has been connected to the power
supply.
2. Press and hold the Z-button for 5 seconds.
3. If holding time is more than one second, the LED will blink faster and
faster. If holding time is more than 5 seconds, the LED will be solid for
3 seconds to indicate that the resetting is successful. Otherwise,
repeat step 2.
NOTE:
Reset to factory will remove Smart Plug from the Z-Wave network. Use this
procedure only in the event that the network primary controller missing or
otherwise inoperable.
Smart Plug is excluded from a Z-Wave network:
Trigger
Description
Power on
1. Send Node Info frame.
2. Add for inclusion:
1. Make sure that the Smart Plug has been connected to the power
supply.
2. Set the Z-Wave network main controller into inclusion mode.
3. Power on.
4. The LED will blink fast until the inclusion is completed and then the
LED will keep turning on or off. Otherwise, the LED will still blink
slowly, in which you need to repeat the process from step 2
Short press
one time
1. Change the state of Smart Plug’s load.
2. Send Node Info frame.
3. Add for inclusion:
1. Make sure that the Smart Plug has been connected to the power
supply.
2. Set the Z-Wave network main controller into inclusion mode.
3. Short press the z-button.
4. The LED will blink fast until the inclusion is completed and then the
LED will keep turning on or off. Otherwise, the LED will still blink
slowly, in which you need to repeat the process from step 2
Short press 3
times within
1 second
1. Send Node Info frame.
2. Add for inclusion:
1. Make sure that the Smart Plug has been connected to the power
supply.
2. Set the Z-Wave network main controller into inclusion mode.
3. Short press the z-button 3 times within 1 second.
4. The LED will blink fast until the inclusion is completed and then the
LED will keep turning on or off. Otherwise, the LED will still blink
slowly, in which you need to repeat the process from step 2
5. SAFETY INFORMATION
WARNING:
• For indoor use only. Do not use in wet locations.
• The total current limit of the device is 15A. Do not exceed this value!
• If a direct short is created on the output, the Smart Plug will be damaged and no longer
function.
• Do not disassemble the product, or make repairs yourself. You run the risk of electric shock
and voiding the limited warranty. If you need service, please contact us.
-----------------------------------------------------------------------------------------For more information, Welcome visit: www.leedarson.com.
Mail to: iot@leedarson.com
LEEDARSON LIGHTING CO., LTD.
XINGDA RD, XINGTAI INDUSTRIAL ZONE, CHANGTAI COUNTY, ZHANGZHOU,FUJIAN, 363900,
CHINA
FCC statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20cm between the radiator
and any part of your body.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference. (2) This device must
accept any interference received, including interference that may cause undesired
operation.
Caution: The user is cautioned that changes or modifications not expressly approved
by the party responsible for compliance could void the user's authority to operate the
equipment.
Note: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
IC NOTICE TO CANADIAN USERS
Déclaration d’exposition aux radiations:
Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum
de 20 cm de distance entre la source de rayonnement et votre corps.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil
ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
This Class B digital apparatus complies with Canadian ICES‐003 (Cet appareil numérique de la
Classe B conforme à la norme NMB‐003 du Canada).
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the
following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
This equipment complies with IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
20cm between the radiator & your body.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : powell
Create Date                     : 2018:08:17 15:07:06+08:00
Modify Date                     : 2018:08:17 15:07:06+08:00
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2018:08:17 15:07:06+08:00
Creator Tool                    : Adobe Acrobat Pro 9.0.0
Format                          : application/pdf
Creator                         : powell
Document ID                     : uuid:597cc72a-7e01-4c46-8f96-3cdb323f6e08
Instance ID                     : uuid:87a157d2-74db-4679-b924-efb79732413e
Producer                        : Adobe Acrobat Pro 9.0.0
Page Count                      : 6
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AB2Q6APLVABA0

Navigation menu