Leedarson Lighting 6ZY-A806ST-Q1M 5.8G Motion & Photon Integrated LED Lamp User Manual

LEEDARSON LIGHTING CO., LTD. 5.8G Motion & Photon Integrated LED Lamp Users Manual

Users Manual

Download: Leedarson Lighting 6ZY-A806ST-Q1M 5.8G Motion & Photon Integrated LED Lamp User Manual
Mirror Download [FCC.gov]Leedarson Lighting 6ZY-A806ST-Q1M 5.8G Motion & Photon Integrated LED Lamp User Manual
Document ID3419718
Application IDVx6ixg4GvQrX1gyy78JUMA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize13.28kB (166025 bits)
Date Submitted2017-06-09 00:00:00
Date Available2017-09-07 00:00:00
Creation Date2017-05-02 17:46:12
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2017-05-02 17:46:12
Document TitleMicrosoft Word - Instruction of Motion & Photon Integrated Lamp-5.8G NA 20170502.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: yf138

Instruc
ction off Motion
n & Pho
oton Inte
egrated
d Lamp
1. Speciffication Pa
arameter
Model
6ZB-A8
806ST-Q1M
Voltage
120
Power
9W
Power Factor
>0.7
Standb
by Power
<0.5W
Lumino
ous Flux
806lm
Color Temperature
2700K
Beam Angle
240°
CRI
80
Triggerred
Illumina
ance
<10lux
Delay Time
40s
Detective Angle
0-180°
Detective Range
4-8m
Operating Ambientt
Tempe
erature
0℃
-20~40
Rated Lamp
Life
25000H
Hrs
Freque
ency
5.8G
Standa
ard
UL, FC
CC
2. Installa
ation & Working
priinciple
For best sensor perrformance, w
we advise:
off-grou
und installation→base u p (height=<5
5m)
on-grou
und installation→base do
own
Eve
ery time pow
wer on physic
cally, lamp w
will keep 4s on then turn
n off to insure
re the
funcctionality, aftter 3s the lam
mp will turn on or keep off according to the conndition.
Lam
mp only workks in the illum
minance tha
at less than 10lux,
it will instantly turrns on when
n it
dete
ects motion, and automa
atically turn off after 40 seconds wh
hen no motioon is detecte
ed.
3.
Atten
ntions
a. This producct cannot be used within
n in a metal cover
or a th
hick glass coover, otherw
wise
the sensor detective
ran
nge and ang
gle will be afffected.
b. The best se
ensor angle is 0°- 180°
°.
c. Detection distance is arround 3-5 m
meters when lamp works
s in a 2-3m hheight with base
down
d. The delay tiime is 40 se
econds; it is ccalculated from last movement it deetected.
e. Pay attentio
ent: the prod
on to installe
ed environme
duct will kee
ep working aat night (or dark
place) if the
e place involv
ves lots of m
movements.
f. Advised pla
ace to install: porch, corrridor, balcon
ny, aisle, sta
air, etc.
g. In an open room
withou
ut walls or an
ny other barrier, sensor lamps shouuld be installe
ed in
interval of ≥8
≥ meters to
t avoid inte
erference between the th
hem.
4.
Warning
Thiss device com
mplies with Part
P 15 of the FCC Rule
es. Operation
n is subject to the follow
wing
two conditions: (1) this deviice may not cause harm
mful interfere
ence, and (22) this device
musst accept any interferenc
ce received,, including in
nterference that
may caause undesirred
operation.
FCC
C Caution:
Cha
anges or mo
odifications not
n expresslyy approved by the part responsible
for compliance
could void the user's
authority to opera
ate the equip
pment.
FCC
C Statementt:
"Thiis equipmen
nt has been tested
and ffound to com
mply with the
e limits for a Class B dig
gital
deviice, pursuan
nt to part 15 of the FCC Rules. Thes
se limits are
e designed too provide
reassonable prottection again
nst harmful interference
e in a residen
ntial installaation. This
equipment gene
erates, uses
s and can ra
adiate radio frequency
energy and, iif not installe
ed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help."

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : yf138
Create Date                     : 2017:05:02 17:46:12+08:00
Modify Date                     : 2017:05:02 17:46:12+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : Microsoft Word - Instruction of Motion & Photon Integrated Lamp-5.8G NA 20170502.docx
Creator                         : yf138
Document ID                     : uuid:73c065b3-f4cc-4606-af83-1369bd7ffc62
Instance ID                     : uuid:5d3a3ba5-6032-4c52-84b9-7f0b38e7ffc5
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AB2Q6ZY-A806ST-Q1M

Navigation menu