Lester Electrical of Nebraska 22240 Data Collection Module User Manual OUH22240 User s Manual

Lester Electrical of Nebraska Inc Data Collection Module OUH22240 User s Manual

Manual

Download: Lester Electrical of Nebraska 22240 Data Collection Module User Manual OUH22240   User s Manual
Mirror Download [FCC.gov]Lester Electrical of Nebraska 22240 Data Collection Module User Manual OUH22240   User s Manual
Document ID138458
Application IDGHamAARdAjz8aCXxl7KtLQ==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize1.57kB (19627 bits)
Date Submitted2001-02-28 00:00:00
Date Available2001-02-28 00:00:00
Creation Date0000-00-00 00:00:00
Producing SoftwareAcrobat PDFWriter 3.02 for Windows
Document Lastmod2001-02-14 14:31:11
Document TitleOUH22240 - User's Manual
Document CreatorMicrosoft Word
Document Author: HS Berger

RF DATA COLLECTOR Exhibit
FCC ID#: OBH 22240
MODEL 22240
FCC ID #OBH22240
PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS
For correct operation of the equipment, it is important to read and be familiar
with this entire manual before installing and operating the charger.
DO NOT DISCARD THIS MANUAL AFTER READING.
LOOK FOR THIS SYMBOL TO POINT OUT SAFETY PRECAUTIONS. IT MEANS:
BECOME ALERT—YOUR SAFETY IS INVOLVED. IF YOU DO NOT FOLLOW THESE
SAFETY INSTRUCTIONS, INJURY OR PROPERTY DAMAGE CAN OCCUR.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
ASSEMBLY PROCEDURE
1. Examine the cables between the battery and DC
plug. With caution, use the Anderson TerminalCable extractor to remove only the positive
(RED) battery cable contact from the battery DC
plug housing.
2. From the RF Data Collector case assembly,
remove the bottom half of the case and the
plastic cord clamping device.
INSTALLATION INSTRUCTIONS
Tools needed to install RF Data Collector Model
22240: 11/32" nut driver, Phillips screwdriver,
Anderson Connector-Terminal Cable extractor
3. Carefully slide the positive (RED) cable contact
through the BLUE ring toroid, located in the top
half of case, with the ring "end" of the Data
Collector facing the battery. Reposition the RED
cable contact inside the battery DC plug
housing. Locate the RF Data Collector case top
(with LED facing up) close to the DC plug
housing and outside of all metal enclosures.
CAUTION: USE CAUTION WHEN WORKING
WITH INDUSTRIAL BATTERIES; THEY CAN BE
VERY DANGEROUS. INDUSTRIAL BATTERIES
CONTAIN ACID (ELECTROLYTE SOLUTION)
WHICH CAN CAUSE CHEMICAL BURNS AND
SERIOUS HARM TO SKIN AND EYES. ALWAYS
WEAR APPROVED PROTECTIVE EYE GOGGLES
AND RUBBER GLOVES. AVOID PROLONGED
BREATHING OF BATTERY VAPORS; WORK IN A
WELL-VENTILATED AREA. BATTERY VAPORS
CAN BE FLAMMABLE. DO NOT REST TOOLS
ON TOP OF BATTERY OR ALLOW ANY METAL
OBJECTS TO COME IN CONTACT WITH
BATTERY
POSTS
OR
INTER-CELL
CONNECTORS.
Operating Instructions
4. Lay the negative (BLACK) battery cable in the
area provided next to the positive (RED) cable.
5. Position the plastic battery cable clamp over
both of the wires so that the clamp slides easily
over the studs located in the RF Data Collector.
Verify that the arrows on top of the clamp point
toward the BLUE ring/battery end of the cables.
6. Using hand pressure only, carefully exert
downward force on the plastic battery cable
clamp until enough of the studs protrude through
the clamp to allow starting the hex nuts.
31083A
7. Tighten the hex nuts evenly. Never exceed 30
pound-inches of torque on the nuts. Failure to
tighten the nuts evenly or overtightening can
cause loss of electrical connection, part
breakage, or cable damage.
not blink, verify the polarity of connections to
determine the cause.
11. During normal operation of the battery, the LED
on the RF Data Collector will blink RED,
indicating a run or discharge condition. The
LED will blink GREEN while the battery is being
charged.
8. Assemble the bottom cover to the unit.
9. Insert the four cover screws in the holes
provided. Do not overtighten.
There are no user serviceable parts in the Universal
Transceiver or Base Station PC. Any attempt to
access or repair any internal components will void
the manufacturer's warranty.
OPERATIONAL INSTRUCTIONS –
RF Data Collector Model 22240
For product warranty or customer assistance, please
contact Lester Electrical, Inc. at (402) 477-8988.
10. The LED located on top of the RF Data Collector
should be blinking from RED to GREEN rapidly,
indicating a proper installation. If the LED does
Exhibit 8
FCC ID#: OBH 22240
Manufactured by Lester Electrical, Inc.
Lincoln, Nebraska
Operating Instructions
31083A

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Creator                         : Microsoft Word
Create Date                     : Thursday, January 11, 2001 2:12:40 PM
Title                           : OUH22240 - User's Manual
Author                          : HS Berger