Leviton RZCPG Programmable Remote User Manual 1 of 2
Leviton Manufacturing Co., Inc. Programmable Remote 1 of 2
Leviton >
Contents
- 1. User Manual 1 of 2
- 2. User Manual 2 of 2
User Manual 1 of 2
Programmer/Remote Cat. RZCPG USER GUIDE • – • • 1 ON OFF 2 ON OFF 3 ON OFF 4 ON OFF Compatible with TM enabled products! TABLE OF CONTENTS INTRODUCTION........................................................1 MENU NAVIGATION & ICONS..............................2–4 STARTUP...................................................................5 INSTALLATION CHECKLIST....................................5 Include Dimmers/Switches.....................................6 TEXT EDITOR....................................................6, 7 Include Controller............................................7, 8 Update Controller.............................................8, 9 Create Areas...................................................9, 10 Set Associations.......................................... 10, 11 Security............................................................... 11 Install Complete.................................................12 MAIN Menu screen.............................................13 device list............................................................13 who is................................................................13 area...................................................................14 profile........................................................14, 15 events.........................................................15, 16 settings...........................................................16 DATE & TIME..................................................16 CONTRAST.....................................................17 BUZZER..........................................................17 LOCATION......................................................17 SECURITY.......................................................18 BATTERY LEVEL............................................18 EVENTS SETUP..............................................18 sYSTEM SETUP (Advanced Settings).............19 NETWORK................................................19–22 ASSOCIATION................................................22 HAI SETUP.....................................................23 RTS DEVICES................................................23 UTILITIES..................................................23, 24 INTRODUCTION Leviton’s Programmer/Remote, Cat. No. RZCPG, is a multifunctional device. It uses Z-WaveTM technology to act as a programmer, zone or scene controller, remote and timer for setting up and operating your ViziaTM RF network. This manual will guide you through the understanding of your RZCPG functions as a setup controller. Once your network is installed, your RZCPG may also be used as a wireless controller for activating events, and controlling your lighting system. Your RZCPG comes with rechargeable batteries, a programmer/remote stand, and a power adapter. NOTE: Upon initial installation, you will need to charge your RZCPG for twelve (12) hours before programming and use. WARNING: Leviton only supports the use of the supplied rechargeable Ni-MH "AA" size batteries. RZCPG Programmer/Remote • – Power Adapter • • 1 ON OFF 2 ON OFF 3 ON OFF 4 ON RZCPG Stand OFF FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving Antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/tv technician for help. MENU NAVIGATION and ICONS Navigating screens and menus on your RZCPG is accomplished using the following buttons: LCD Display x1 (HOME screen depicted) 12:00 PM Mon 05.01.2006 Left Soft Key Default Profile Stand By Right Soft Key Menu Arrow Buttons (up, down, left, right) Center Button x1 1 ON "–" Button OFF 12:00 PM ON x1 OFF Mon 05.01.200 6 12:00 PM 3 ON OFF 4 ON OFF "+" Button Mon 05.01.200 Default Profile Stand By Menu The right soft key brings x1 Default Profile you to the MAIN MENU screen MAIN MENU Stand By List Menu 1. Device from the HOME screen and is 2. Who Is... used for saving and completing 3. Area tasks. 4. Profile 5. Events Back Home The left soft key is used to bring you back to the previous screen. The up and down arrow buttons allow you to scroll through each screen and will move the selection box ( 1. Device List ) to each choice. CENTER BUTTON NOTE: Selections are made on OFF each screen by ONpressing the center button on the RZCPG unless prompted otherwise. 1 ON 2 ON OFF OFF OFF <> appears on various screens as a prompt to create something new (Area, Profile, Event, etc.) x1 AREA << NEW >> Back x1 Home All Devices x1 Mon 05.01.200 6 Default Profile Stand By Menu Check boxes are used when multiple selections are All Devices Dimmer #1 available. Use the and x1 Switch #1 buttons to select and deselect Switch #2 from a list. 2 PROFILE selected 1 << NEW >> Back (3) Who Is Scene 4 12:00 PM Zone Radio buttons are used x1 when an "either/or" single choice PROFILE << NEW >> is available. Scroll the selection Profile #1 box to your choiceBack and use the Done Profile #2 button to select. OFF x1 OFF OFF Dimmer Switch Switch Menu Menu All Dev Menu Default Profile Stand By x1 12:00 PM Mon 05.01.200 6 Mon 0 5 .0 1 .2 0 0 6 Save Mon 0 5 .0 1 .2 0 0 6 x1 Cancel Default Profile All Devices 1. All Devices 2. < ON > 3. Default Fade Default Profile Stand By Single brackets2. < ON > 3. Default Fade designate that more than one choice is available. Use the left Cancel and right side arrow buttons Save to toggle between choices. 12:00 PM 12:00 PM Stand By 1 ON 1 ON 2 ON 1. All Devices x1 x1 Mon 05.01.200 6 Default Profile Stand By Home Back ON OFF 2 ON OFF 3 ON OFF ON ON OFF OFF ON ON OFF OFF ON OFF selecte Back (3) x1 OFF OFF OFF OFF OFF OFF Area #1 The Filter is used when you wish to view only checked Bedroom devices, or only unchecked devices from a list.Bathroom Use the right arrow button Hallto toggle between showing devices checked, unchecked or all (no selected 3 filter). Back (3) Menu selected 3 (3) Who Is Back ON Default Profile Bedroom Bathroom Hall OFF Stand By 4 ON OFF ON 1 ON 2 ON 3 ON 4 ON x1 Area #1 Menu ON Who Is Leviton also provides various icons that appear on the screens to provide quick review of the state of your network, selections made and to assist in identification of devices (refer to Icon Description chart). ICON DESCRIPTION Undefined device Center button Single choice (radio button) - not chosen Single choice (radio button) - chosen Multiple selection (checkbox) - not selected Multiple selection (checkbox) - selected Remote Control Zone/Scene Controller (Single or Multibutton) Dimmer Switch Thermostat Event is Set Event Disabled or All Events are Disabled Buzzer OFF (indication) Buzzer OFF Buzzer ON Error Indication Event Recurrence One Time Event Date Event Time Time of Day or Dawn/Dusk Offset Filter (data on screen is filtered) Power Adapter Battery Power STARTUP NOTE: Upon initial power up of x1 the RZCPG, the VIZIATMRF logo DATE & TIME will appear briefly and then the Time: 09: 00 AM DATE & TIME screen will display, Date: 06. 07. 2007 prompting the user to change Wednesday the settings. NOTE: Leviton Save Cancel recommends setting the date and time before proceeding. Failure to do so will disable your events (refer to EVENTS pg. 15). Set the date and time for your RZCPG as follows: x1 x1 12:00 PM Mon 05.01.200 6 DATE & TIME Default Profile Stand By 12:00 PM Mon 05.01.200 6 Default Profile Menu Stand By Menu 1. Use the arrow buttons to navigate and set the date & time using the and buttons. 2. Press right soft key (Save). x1 You will be prompted to INSTALL CHEKLIST START INSTALLATION START CHECKLIST. 4 INSTALLATION CHECKLIST Press right soft key (YES). The INSTALL CHECKLIST screen will NO YES appear. ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF INSTALLATION CHECKLIST Leviton provides the Installation Checklist as a step by step tool to setup your ViziaTMRF network and recommends following these steps in order, specifically if you are a first time user. System design will impact performance, so it is necessary to include and update your devices in a specific order to ensure overall system performance and reliability. The Installation Checklist steps are shown below. When a step is completed, simply press the right soft key to select NEXT STEP and the RZCPG will bring you to the next screen. x1 x1 INSTALL CHECKLIST INSTALL CHECKLIST 1. Include Dim/Swch 2. Include Controller 3. Update Controller 4. Create Areas 5. Set Associations Back Next Step 3. Update Controller 4. Create Areas 5. Set Associations 6. Security 7. Install Complete Back Next Step Using your RZCPG, follow these steps to set up your ViziaRFTM network: STEP 1 Include Dimmers/Switches Pressing the center button x1 to select Include Dim/Swch INCLUDE DIM/SWCH Press button on will bring you to the INCLUDE Dimmer/Switch DIM/SWCH screen and put the RZCPG into Inclusion Mode. You will be prompted to press a button on your Dimmer, Switch or Cancel Plug-In Module. These devices require a simple one step process (button press) to include into the network (refer to individual device instruction sheet). Once the button is pressed on your Dimmer, Switch or Plug-In Module, the RZCPG will go through a communication process and assign the node information for that device. The TEXT EDITOR will display. You can now name your device. NOTE: The RZCPG is by default assigned #1. TEXT EDITOR x1 Using TEXT EDITOR you can x1 12:00 PM either assign a name from EDITOR M oa n list 0 5 . 01.200TEXT x1 Switch #2 of templates or assign a unique name to your device. 12:00 PM Leviton Switch #2 Mon Default 05.01.200 6e NOTE: The right soft key will Profil Menu Save? Press toggle from Template toStand AbcByto Template ABC to abc to 123 and back to Default Profile Template again. ThisStand feature allows you to access By Menu the template names or to select capital/undercase letters and numerals to name your device. To use the pre-made Templates, x1 with Template displayed, use the TEXT EDITOR Switch #2 up and down arrow buttons Leviton to select a name. The RZCPG Bedroom offers a list of over 100 commonly used names to choose from. Save? Press Abc NOTE: The template names OFF 1 ON are editable for customization if you choose to alter them. OFF 1 ON 2 ON OFF 2 ON 3 ON OFF OFF 3 ON 4 ON OFF OFF Default Profile Menu x1 x1 OFF OFF OFF OFF OFF OFF Menu Default Profile Stand By ON Menu OFF Default Profile Stand By ON Menu OFF 1 ON 1 ON 2 ON 2 ON 3 ON 3 ON 4 ON 4 ON Menu Stand By Default Profile Default Profile Stand By To create a unique name or modify text, under ABC (or Abc, abc, 123) use the up and down arrow buttons to change each letter or numeral and side arrow buttons to navigate. The and buttons can be used to insert and delete characters.1 Once your template or created x1 1 ONis displayed, OFF name press the INCLUDE DIM/SWCH center button .Your device 4 Node included! 4 Node ID# 2: in OFF 1has ON now been included Bedroom OFFchosen 2 network ON the with your name. The RZCPG will confirm More? Press OFF with the name displayed Back 2inclusion ON Next Step OFF 3 ON and prompt you to continue to INCLUDE DIM/SWCH by pressing the center button OFFto the Next step by pressing the 3 ON or to continue 4 ON right soft key . OFF Mon 05.01.200 6 x1 12:00 PM 12:00 PM Mon 05.01.2006 Mon 05.01.200 6 OFF 12:00 PM 12:00 PM Mon 05.01.200 6 OFF Stand By ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF 2 Include OFF Controller 4STEP ON x1 NOTE: The INSTALL INSTALL CHECKLIST CHECKLIST screen will appear 1. Include Dim/Swch with the selection box around 2. Include Controller STEP 2 - Include Controller 3. Update Controller when NEXT STEP is chosen from 4. Create Areas 5. Set Associations STEP 1. Back Next Step Press the center button on x1 the RZCPG to bring up the INCLUDE CNTRLLER INCLUDE CNTRLLER screen, Place controller where you will be prompted to in program mode place the controller in program See Instruction sheet mode. Begin? Press NOTE: Leviton Controllers Return require an inclusion process that differs from Dimmers, Switches and Plug-In Modules. Controllers must be placed into program mode before they can be included into the network (refer to individual device instruction sheet). Once your controller has been placed in program mode, press the center button on the RZCPG. The RZCPG will go through the communication process and assign the node information for that device. The TEXT EDITOR will display where you can name your device (refer to TEXT EDITOR pg. 6). Once your name is displayed, x1 INCLUDE CNTRLLER press the center button .The Node included! RZCPG will confirm inclusion Node ID #3: and prompt you to continue to Room Controller INCLUDE CONTROLLER by More? Press pressing the center button or Back Next Step to continue to the Next step by pressing the right soft key NOTE: The confirmation process will take some time, specifically in large networks. Remain close to the controller until the confirmation is complete. STEP 3 Update Controller NOTE: The INSTALL x1 CHECKLIST screen will appear INSTALL CHECKLIST 1. Include Dim/Swch with the selection box around 2. Include Controller STEP 3 - Update Controller 3. Update Controller when NEXT STEP is chosen 4. Create Areas 5. Set Associations from STEP 2. Back Next Step Press the center button to bring up the UPDATE CNTRLS x1 screen where a list of all the UPDATE CNTRLS controllers in the network will be Room Controller Hall Controller displayed. With the selection box around the first controller listed press the center button . The Back (2) Who Is RZCPG will prompt you to stand within 3 feet of that controller. x1 Press the right soft key (YES) UPDATE to update your controller. NOTE: Please stand within 3 ft from controller It is important that you remain and press YES within 3 ft. of the controller to continue you've selected from the list. If you are unsure about which NO YES controller you are updating x1 you can use the "Who Is" UPDATE command (see pg. 13). Node Updated! Leviton controllers will blink Node ID #4 Room controller during the update process, confirming you are updating the correct controller. Return Once the RZCPG confirms UPDATE it will display the updated node information. Press the center button to finalize. Continue this process until all of your controllers have been updated. Each time you successfully update your controller it will be removed from the list. Once all of your controllers have been updated, press the right soft key to continue to the NEXT STEP. x1 STEP 4 Create Areas INSTALL CHECKLIST NOTE: The INSTALL CHECKLIST screen will appear with the selection box around STEP 4 - Create Areas when NEXT STEP is chosen from STEP 2. Press the center button to bring up the AREA screen. With << NEW >> selected press the center button to bring up the CREATE AREA screen. You can now name your new area by pressing the center button (refer to TEXT EDITOR pg. 6). Once you name your new area, press the center button to save the information and return to the CREATE AREA screen. Scroll to and press the center button to select Add Devices which will bring up a list of the dimmers and switches you included in Step 1 to add to your new area. Scroll to each device check box and use the and buttons to either add or subtract1 each device from your area. NOTE: You can use the 4 ON button 4 ON 4 on OFF the bottom of the RZCPG to select ALL devices simultaneously. The OFF deselects 4 ON 4 OFF button ALL devices. This feature will work whenever you encounter check box lists. x1 12:00 PM Mon 05.01.200 6 Default Profile Stand By 1. Include Dim/Swch 2. Include Controller 3. Update Controller 4. Create Areas 5. Set Associations Back Next Step x1 AREA << NEW >> Back CREATE AREA Name: Area #1 Add Devices... Cancel x1 Mon 05.01.200 6 Stand By Menu Save x1 12:00 PM AREA #1 Default Profile Menu Next Step x1 Bedroom Bathroom Hall selected 1 Back (3) Who Is ON OFF ON ON OFF ON OFF OFF ON OFF ON OFF ON OFF ON OFF x1 AREA << NEW >> Area #1 Back Next Step STEP 5 Set Associations OFF OFF OFF OFF OFF OFF OFF OFF Menu NOTE: The INSTALL INSTALL CHECKLIST CHECKLIST screen will appear 1. Include Dim/Swch with the selection box around 2. Include Controller 3. Update Controller STEP 5 - Set Associations 4. Create Areas when NEXT STEP is chosen 5. Set Associations from STEP 4. Back Next Step Press the center button to x1 bring up the ASSOCIATION ASSOCIATION screen. Room Controller A list of controllers included in Hall Controller Step 2 that support association Den Controller will be displayed. Scroll to and press the center Back Next Step button to select the controller x1 you wish to associate an area or CONTROLLER ASSOC areas to. Dev: Room Controller The CONTROLLER ASSOC 1. < Button 1 > 2. Area #1 screen will display with the 3. Area ON/OFF selection box around 1. Button prompting you to select the Cancel Save button on your controller that you wish to associate an area to. Use side arrow buttons to toggle if applicable. Scroll to 2. Area and choose an area you wish to associate to the button you've selected. This will allow the button on the chosen controller to control the desired area. Selecting 3. Area ON/OFF allows you to set an AREA ON/OFF or SCENE command to that button on your controller (for SCENE commands refer to Advanced Settings). 10 1 ON 1 ON 2 ON 2 ON 3 ON 3 ON 4 ON 4 ON Menu Default Profile Stand By x1 Stand By Default Profile Once you have checked the devices for your area press the center button to save. The AREA screen will display with your newly created area and prompt you to continue to create a new area by pressing the center button to select < > or to continue to the Next step by pressing the right soft key . NOTE: You can use the 1 ON button 1 ON andOFF OFF on the RZCPG to turn the 1 ON 1 OFF button lights ON and OFF in an area that has the selection box around it. STEP 6 Security OFF OFF OFF OFF OFF OFF OFF OFF Menu 1 ON 1 ON 2 ON 2 ON 3 ON 3 ON 4 ON 4 ON Menu Default Profile Stand By NOTE: The INSTALL INSTALL CHECKLIST CHECKLIST screen will appear 2. Include Controller with the selection box around 3. Update Controller 4. Create Areas STEP 6 - Security when NEXT 5. Set Associations STEP is chosen from STEP 5. 6. Security Press the center button to Back Next Step bring up the SECURITY screen. x1 Press the center button to select 1. Setup Password. SECURITY Enter password using four of the 1. Setup Password 2. < OPEN > eight buttons on the RZCPG (1 ON, 1 OFF, 2 ON, 2 OFF etc.) NOTE: The password you Back Save choose MUST be 4 characters long. x1 You will be prompted to, and SECURITY must re-enter password. 1. Setup Password 2. < RZCPG Lock > Scroll to 2. and use the side arrow buttons to toggle between choices OPEN, RZCPG Back Save Lock and System Lock. Press right soft key (Save) to complete. NOTE: Selecting will lock the RZCPG. When you return to the HOME screen you will not have access to the MAIN MENU nor any screens until you press the right soft key and enter your password. Selecting will only lock System Setup, preventing one from changing how the system is configured until the password is entered upon prompt. Stand By 12:00 PM Default Profile x1 Mon 05.01.200 6 Mon 05.01.2006 Once you are done press the right soft key (Save) to complete. You will be prompted to continue setting associations or to proceed to the Next step by pressing the right soft key 11
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2007:07:19 09:57:01-04:00 Create Date : 2007:07:19 09:56:13-04:00 Creator : Adobe InDesign CS2 (4.0.2) Producer : Adobe PDF Library 7.0 Page Count : 13 Mod Date : 2007:07:19 09:57:01-04:00 Creation Date : 2007:07:19 09:56:13-04:00 Metadata Date : 2007:07:19 09:57:01-04:00 Has XFA : NoEXIF Metadata provided by EXIF.tools