Leviton RZCPG Programmable Remote User Manual 1 of 2

Leviton Manufacturing Co., Inc. Programmable Remote 1 of 2

Contents

User Manual 1 of 2

Download: Leviton RZCPG Programmable Remote User Manual 1 of 2
Mirror Download [FCC.gov]Leviton RZCPG Programmable Remote User Manual 1 of 2
Document ID824544
Application IDtXrt0G271+5Tx76L0FhImQ==
Document DescriptionUser Manual 1 of 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize192.5kB (2406196 bits)
Date Submitted2007-08-01 00:00:00
Date Available2007-08-01 00:00:00
Creation Date2007-07-19 09:56:13
Producing SoftwareAdobe PDF Library 7.0
Document Lastmod2007-07-19 09:57:01
Document TitleUser Manual 1 of 2
Document CreatorAdobe InDesign CS2 (4.0.2)

Programmer/Remote
Cat. RZCPG
USER GUIDE
•
–
•
•
1 ON
OFF
2 ON
OFF
3 ON
OFF
4 ON
OFF
Compatible with
TM
enabled products!
TABLE OF CONTENTS
INTRODUCTION........................................................1
MENU NAVIGATION & ICONS..............................2–4
STARTUP...................................................................5
INSTALLATION CHECKLIST....................................5
Include Dimmers/Switches.....................................6
TEXT EDITOR....................................................6, 7
Include Controller............................................7, 8
Update Controller.............................................8, 9
Create Areas...................................................9, 10
Set Associations.......................................... 10, 11
Security............................................................... 11
Install Complete.................................................12
MAIN Menu screen.............................................13
device list............................................................13
who is................................................................13
area...................................................................14
profile........................................................14, 15
events.........................................................15, 16
settings...........................................................16
DATE & TIME..................................................16
CONTRAST.....................................................17
BUZZER..........................................................17
LOCATION......................................................17
SECURITY.......................................................18
BATTERY LEVEL............................................18
EVENTS SETUP..............................................18
sYSTEM SETUP (Advanced Settings).............19
NETWORK................................................19–22
ASSOCIATION................................................22
HAI SETUP.....................................................23
RTS DEVICES................................................23
UTILITIES..................................................23, 24
INTRODUCTION
Leviton’s Programmer/Remote, Cat. No. RZCPG, is a multifunctional device. It uses Z-WaveTM technology to act as a
programmer, zone or scene controller, remote and timer for
setting up and operating your ViziaTM RF network. This manual
will guide you through the understanding of your RZCPG
functions as a setup controller. Once your network is installed,
your RZCPG may also be used as a wireless controller for
activating events, and controlling your lighting system.
Your RZCPG comes with rechargeable batteries, a
programmer/remote stand, and a power adapter.
NOTE: Upon initial installation, you will need to charge your
RZCPG for twelve (12) hours before programming and use.
WARNING: Leviton only supports the use of the supplied
rechargeable Ni-MH "AA" size batteries.
RZCPG
Programmer/Remote
•
–
Power
Adapter
•
•
1 ON
OFF
2 ON
OFF
3 ON
OFF
4 ON
RZCPG
Stand
OFF
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits
for a Class B Digital Device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment OFF and ON, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the
receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
MENU NAVIGATION and ICONS
Navigating screens and menus on your RZCPG is
accomplished using the following buttons:
LCD
Display
x1
(HOME screen
depicted)
12:00 PM
Mon 05.01.2006
Left
Soft Key
Default Profile
Stand By
Right Soft
Key
Menu
Arrow
Buttons
(up, down,
left, right)
Center
Button
x1
1 ON
"–"
Button
OFF
12:00
PM
ON
x1
OFF
Mon 05.01.200 6
12:00 PM
3 ON
OFF
4 ON
OFF
"+"
Button
Mon 05.01.200
Default
Profile
Stand By
Menu
The right soft key
brings
x1
Default
Profile you to the MAIN MENU screen
MAIN MENU
Stand
By List Menu
1. Device
from the HOME screen and is
2. Who Is...
used for saving and completing
3. Area
tasks.
4. Profile
5. Events
Back
Home
The left soft key
is used
to bring you back to the previous
screen.
The up
and down
arrow buttons allow
you to scroll through each screen and will move
the selection box ( 1. Device List
) to each
choice.
CENTER BUTTON
NOTE: Selections are made on
OFF
each screen by
ONpressing the center
button on the RZCPG unless
prompted otherwise.
1 ON
2 ON
OFF
OFF
OFF
<> appears on various
screens as a prompt to create
something new (Area, Profile,
Event, etc.)
x1
AREA
<< NEW >>
Back
x1
Home
All Devices
x1
Mon 05.01.200 6
Default Profile
Stand By
Menu
Check boxes
are used
when multiple selections are
All Devices
Dimmer #1
available. Use the
and
x1
Switch #1
buttons to select
and deselect
Switch #2
from a list. 2
PROFILE
selected 1
<< NEW
>>
Back (3) Who Is
Scene 4
12:00 PM
Zone
Radio buttons
are used
x1
when an "either/or" single choice
PROFILE
<< NEW >>
is available. Scroll the selection
Profile #1
box to your choiceBack
and use the Done
Profile #2
button to select.
OFF
x1
OFF
OFF
Dimmer
Switch
Switch
Menu
Menu
All Dev
Menu
Default Profile
Stand By
x1
12:00 PM
Mon 05.01.200 6
Mon 0 5 .0 1 .2 0 0 6
Save
Mon 0 5 .0 1 .2 0 0 6
x1
Cancel
Default Profile
All Devices
1. All Devices
2. < ON >
3. Default Fade
Default Profile
Stand By
Single brackets2. < ON >
3. Default Fade
designate that more
than one
choice is available. Use the left
Cancel
and right side arrow
buttons Save
to toggle between
choices.
12:00 PM
12:00 PM
Stand By
1 ON
1 ON
2 ON
1. All Devices
x1
x1
Mon 05.01.200 6
Default Profile
Stand By
Home
Back
ON
OFF
2 ON
OFF
3 ON
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
selecte
Back (3)
x1
OFF
OFF
OFF
OFF
OFF
OFF
Area
#1
The Filter
is used
when
you wish to view only
checked
Bedroom
devices, or only unchecked
devices from a list.Bathroom
Use the
right arrow button Hallto toggle
between showing devices
checked, unchecked or all (no
selected 3
filter).
Back
(3)
Menu
selected 3
(3) Who Is
Back
ON
Default Profile
Bedroom
Bathroom
Hall
OFF
Stand By
4 ON
OFF
ON
1 ON
2 ON
3 ON
4 ON
x1
Area #1
Menu
ON
Who Is
Leviton also provides various icons that appear on
the screens to provide quick review of the state
of your network, selections made and to assist in
identification of devices (refer to Icon Description
chart).
ICON
DESCRIPTION
Undefined device
Center button
Single choice (radio button) - not chosen
Single choice (radio button) - chosen
Multiple selection (checkbox) - not selected
Multiple selection (checkbox) - selected
Remote Control
Zone/Scene Controller (Single or Multibutton)
Dimmer
Switch
Thermostat
Event is Set
Event Disabled or All Events are Disabled
Buzzer OFF (indication)
Buzzer OFF
Buzzer ON
Error Indication
Event Recurrence
One Time Event Date
Event Time
Time of Day or Dawn/Dusk Offset
Filter (data on screen is filtered)
Power Adapter
Battery Power
STARTUP
NOTE: Upon initial power up of
x1
the RZCPG, the VIZIATMRF logo
DATE & TIME
will appear briefly and then the
Time: 09: 00 AM
DATE & TIME screen will display,
Date: 06. 07. 2007
prompting the user to change
Wednesday
the settings. NOTE: Leviton
Save
Cancel
recommends setting the date and
time before proceeding. Failure to
do so will disable your events (refer to EVENTS
pg. 15). Set the date and time for your RZCPG as
follows:
x1
x1
12:00 PM
Mon 05.01.200 6
DATE & TIME
Default Profile
Stand By
12:00 PM
Mon 05.01.200 6
Default Profile
Menu
Stand By
Menu
1. Use the arrow buttons to navigate and set the date
& time using the
and
buttons.
2. Press right soft
key
(Save).
x1
You will be prompted
to
INSTALL CHEKLIST
START INSTALLATION
START
CHECKLIST. 4
INSTALLATION
CHECKLIST
Press right soft key
(YES). The
INSTALL CHECKLIST screen will
NO
YES
appear.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
INSTALLATION CHECKLIST
Leviton provides the Installation Checklist as a step
by step tool to setup your ViziaTMRF network and
recommends following these steps in order, specifically
if you are a first time user. System design will impact
performance, so it is necessary to include and update
your devices in a specific order to ensure overall system
performance and reliability. The Installation Checklist
steps are shown below. When a step is completed,
simply press the right soft key
to select NEXT STEP
and the RZCPG will bring you to the next screen.
x1
x1
INSTALL CHECKLIST
INSTALL CHECKLIST
1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
Back
Next Step
3. Update Controller
4. Create Areas
5. Set Associations
6. Security
7. Install Complete
Back
Next Step
Using your RZCPG, follow these steps to set up
your ViziaRFTM network:
STEP 1 Include Dimmers/Switches
Pressing the center button
x1
to select Include Dim/Swch
INCLUDE DIM/SWCH
Press button on
will bring you to the INCLUDE
Dimmer/Switch
DIM/SWCH screen and put the
RZCPG into Inclusion Mode.
You will be prompted to press a
button on your Dimmer, Switch or Cancel
Plug-In Module. These devices
require a simple one step process (button press) to
include into the network (refer to individual device
instruction sheet). Once the button is pressed on
your Dimmer, Switch or Plug-In Module, the RZCPG
will go through a communication process and assign
the node information for that device. The TEXT
EDITOR will display. You can now name your device.
NOTE: The RZCPG is by default assigned #1.
TEXT EDITOR
x1
Using TEXT EDITOR you can
x1
12:00 PM
either assign a name from
EDITOR
M oa
n list
0 5 . 01.200TEXT
x1
Switch #2
of templates or assign a unique
name to your device. 12:00 PM Leviton
Switch #2
Mon Default
05.01.200
6e
NOTE: The right soft key
will Profil
Menu
Save? Press
toggle from Template toStand
AbcByto
Template
ABC to abc to 123 and back to
Default Profile
Template again. ThisStand
feature
allows
you to access
By
Menu
the template names or to select capital/undercase
letters and numerals to name your device.
To use the pre-made Templates,
x1
with Template displayed, use the
TEXT EDITOR
Switch #2
up and down arrow buttons
Leviton
to select a name. The RZCPG
Bedroom
offers a list of over 100 commonly
used names to choose from.
Save? Press
Abc
NOTE: The template names
OFF
1 ON are
editable for customization if you
choose to alter them.
OFF
1 ON
2 ON
OFF
2 ON
3 ON
OFF
OFF
3 ON
4 ON
OFF
OFF
Default Profile
Menu
x1
x1
OFF
OFF
OFF
OFF
OFF
OFF
Menu
Default Profile
Stand By
ON
Menu
OFF
Default Profile
Stand By
ON
Menu
OFF
1 ON
1 ON
2 ON
2 ON
3 ON
3 ON
4 ON
4 ON
Menu
Stand By
Default Profile
Default Profile
Stand By
To create a unique name or modify text, under
ABC (or Abc, abc, 123) use the up and down arrow
buttons
to change each letter or numeral and
side arrow buttons
to navigate. The
and
buttons can be used to insert and delete
characters.1
Once your template or created
x1
1 ONis displayed, OFF
name
press the
INCLUDE
DIM/SWCH
center button
.Your device
4 Node included! 4
Node ID# 2:
in
OFF
1has
ON now been included
Bedroom
OFFchosen
2 network
ON
the
with your
name. The RZCPG will confirm
More? Press
OFF
with the
name displayed Back
2inclusion
ON
Next Step
OFF
3 ON
and
prompt you to continue
to
INCLUDE DIM/SWCH by pressing the center button
OFFto the Next step by pressing the
3 ON or to continue
4 ON
right
soft key
. OFF
Mon 05.01.200 6
x1
12:00
PM
12:00 PM
Mon 05.01.2006
Mon 05.01.200 6
OFF
12:00 PM
12:00 PM
Mon 05.01.200 6
OFF
Stand By
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
2 Include
OFF Controller
4STEP
ON
x1
NOTE: The INSTALL
INSTALL CHECKLIST
CHECKLIST screen will appear
1. Include Dim/Swch
with the selection box around
2. Include Controller
STEP 2 - Include Controller
3. Update Controller
when NEXT STEP is chosen from 4. Create Areas
5. Set Associations
STEP 1.
Back
Next Step
Press the center button
on
x1
the RZCPG to bring up the
INCLUDE CNTRLLER
INCLUDE CNTRLLER screen,
Place controller
where you will be prompted to
in program mode
place the controller in program
See Instruction sheet
mode.
Begin? Press
NOTE: Leviton Controllers
Return
require an inclusion process
that differs from Dimmers, Switches and Plug-In
Modules. Controllers must be placed into program
mode before they can be included into the network
(refer to individual device instruction sheet).
Once your controller has been placed in program
mode, press the center button
on the RZCPG.
The RZCPG will go through the communication
process and assign the node information for that
device. The TEXT EDITOR will display where you
can name your device (refer to TEXT EDITOR
pg. 6).
Once your name is displayed,
x1
INCLUDE CNTRLLER
press the center button
.The
Node
included!
RZCPG will confirm inclusion
Node ID #3:
and prompt you to continue to
Room Controller
INCLUDE CONTROLLER by
More? Press
pressing the center button
or
Back
Next Step
to continue to the Next step
by pressing the right soft key
NOTE: The confirmation process will take some
time, specifically in large networks. Remain close to
the controller until the confirmation is complete.
STEP 3 Update Controller
NOTE: The INSTALL
x1
CHECKLIST screen will appear
INSTALL CHECKLIST
1. Include Dim/Swch
with the selection box around
2. Include Controller
STEP 3 - Update Controller
3. Update Controller
when NEXT STEP is chosen
4. Create Areas
5. Set Associations
from STEP 2.
Back
Next Step
Press the center button
to
bring up the UPDATE CNTRLS
x1
screen where a list of all the
UPDATE CNTRLS
controllers in the network will be
Room Controller
Hall Controller
displayed. With the selection box
around the first controller listed
press the center button
. The
Back (2) Who Is
RZCPG will prompt you to stand
within 3 feet of that controller.
x1
Press the right soft key
(YES)
UPDATE
to update your controller. NOTE:
Please stand within
3 ft from controller
It is important that you remain
and press YES
within 3 ft. of the controller
to continue
you've selected from the list.
If you are unsure about which
NO
YES
controller you are updating
x1
you can use the "Who Is"
UPDATE
command (see pg. 13).
Node Updated!
Leviton controllers will blink
Node ID #4
Room controller
during the update process,
confirming you are updating
the correct controller.
Return
Once the RZCPG confirms
UPDATE it will display the updated node
information. Press the center button
to finalize.
Continue this process until all of your controllers
have been updated. Each time you successfully
update your controller it will be removed from the
list. Once all of your controllers have been updated,
press the right soft key
to continue to the NEXT
STEP.
x1
STEP 4 Create Areas
INSTALL CHECKLIST
NOTE: The INSTALL
CHECKLIST screen will appear
with the selection box around
STEP 4 - Create Areas when
NEXT STEP is chosen from
STEP 2.
Press the center button
to
bring up the AREA screen. With
<< NEW >> selected press the
center button
to bring up the
CREATE AREA screen. You
can now name your new area
by pressing the center button
(refer to TEXT EDITOR pg. 6).
Once you name your new area,
press the center button
to
save the information and return
to the CREATE AREA screen.
Scroll to and press the center
button
to select Add Devices
which will bring up a list of the
dimmers and switches you
included in Step 1 to add to your
new area. Scroll to each device
check box and use the
and
buttons to either add
or subtract1
each device from your
area.
NOTE: You can use
the
4 ON button 4 ON 4 on OFF
the
bottom of the RZCPG to select
ALL devices simultaneously. The
OFF deselects
4 ON
4 OFF button
ALL devices. This feature will
work whenever you encounter
check box lists.
x1
12:00 PM
Mon 05.01.200 6
Default Profile
Stand By
1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
Back
Next Step
x1
AREA
<< NEW >>
Back
CREATE AREA
Name: Area #1
Add Devices...
Cancel
x1
Mon 05.01.200 6
Stand By
Menu
Save
x1
12:00 PM
AREA #1
Default Profile
Menu
Next Step
x1
Bedroom
Bathroom
Hall
selected 1
Back (3) Who Is
ON
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
x1
AREA
<< NEW >>
Area #1
Back
Next Step
STEP 5 Set Associations
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Menu
NOTE: The INSTALL
INSTALL CHECKLIST
CHECKLIST screen will appear
1. Include Dim/Swch
with the selection box around
2. Include Controller
3. Update Controller
STEP 5 - Set Associations
4. Create Areas
when NEXT STEP is chosen
5. Set Associations
from STEP 4.
Back
Next Step
Press the center button
to
x1
bring up the ASSOCIATION
ASSOCIATION
screen.
Room Controller
A list of controllers included in
Hall Controller
Step 2 that support association
Den Controller
will be displayed.
Scroll to and press the center
Back
Next Step
button
to select the controller
x1
you wish to associate an area or
CONTROLLER ASSOC
areas to.
Dev: Room Controller
The CONTROLLER ASSOC
1. < Button 1 >
2. Area #1
screen will display with the
3. Area ON/OFF
selection box around 1. Button
prompting you to select the
Cancel
Save
button on your controller that
you wish to associate an area to. Use side arrow
buttons
to toggle if applicable.
Scroll to 2. Area and choose an area you wish to
associate to the button you've selected. This will
allow the button on the chosen controller to control
the desired area.
Selecting 3. Area ON/OFF allows you to set an
AREA ON/OFF or SCENE command to that button
on your controller (for SCENE commands refer to
Advanced Settings).
10
1 ON
1 ON
2 ON
2 ON
3 ON
3 ON
4 ON
4 ON
Menu
Default Profile
Stand By
x1
Stand By
Default Profile
Once you have checked the devices for your area
press the center button
to save. The AREA
screen will display with your newly created area
and prompt you to continue to create a new area by
pressing the center button
to select <> or
to continue to the Next step by pressing the right
soft key .
NOTE: You can use the 1 ON button 1 ON
andOFF
OFF on the RZCPG to turn the
1 ON
1 OFF button
lights ON and OFF in an area that has the selection
box around it.
STEP 6 Security
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Menu
1 ON
1 ON
2 ON
2 ON
3 ON
3 ON
4 ON
4 ON
Menu
Default Profile
Stand By
NOTE: The INSTALL
INSTALL CHECKLIST
CHECKLIST screen will appear
2. Include Controller
with the selection box around
3. Update Controller
4. Create Areas
STEP 6 - Security when NEXT
5. Set Associations
STEP is chosen from STEP 5.
6. Security
Press the center button
to
Back
Next Step
bring up the SECURITY screen.
x1
Press the center button
to
select 1. Setup Password.
SECURITY
Enter password using four of the 1. Setup Password
2. < OPEN >
eight buttons on the RZCPG
(1 ON, 1 OFF, 2 ON, 2 OFF etc.)
NOTE: The password you
Back
Save
choose MUST be 4 characters
long.
x1
You will be prompted to, and
SECURITY
must re-enter password.
1. Setup Password
2. < RZCPG Lock >
Scroll to 2. and use the side
arrow buttons
to toggle
between choices OPEN, RZCPG
Back
Save
Lock and System Lock.
Press right soft key
(Save) to complete.
NOTE: Selecting  will lock the
RZCPG. When you return to the HOME screen you
will not have access to the MAIN MENU nor any
screens until you press the right soft key
and
enter your password.
Selecting  will only lock System
Setup, preventing one from changing how the
system is configured until the password is entered
upon prompt.
Stand By
12:00 PM
Default Profile
x1
Mon 05.01.200 6
Mon 05.01.2006
Once you are done press the right soft key
(Save) to complete. You will be prompted to
continue setting associations or to proceed to the
Next step by pressing the right soft key
11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2007:07:19 09:57:01-04:00
Create Date                     : 2007:07:19 09:56:13-04:00
Creator                         : Adobe InDesign CS2 (4.0.2)
Producer                        : Adobe PDF Library 7.0
Page Count                      : 13
Mod Date                        : 2007:07:19 09:57:01-04:00
Creation Date                   : 2007:07:19 09:56:13-04:00
Metadata Date                   : 2007:07:19 09:57:01-04:00
Has XFA                         : No
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QGH-RZCPG

Navigation menu