Leviton RZD10 RF Dimmer User Manual DI 000 ACI06 00A

Leviton Manufacturing Co., Inc. RF Dimmer DI 000 ACI06 00A

Contents

User Manual 1 of 2

PRELIMINARY
Single Pole (One location) or 3-Way (Multi-location)
Incandescent Dimmer
Cat. No. RZI1
Ø
-1L, 1000W (Lighted)
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
Single-Pole Wiring Application:
DI-000-RZI10-00A-X0
Tools needed to install your Dimmer:
Slotted/Phillips Screwdriver Electrical Tape
Pliers Pencil
Cutters Ruler
Changing the color of your Dimmer:
Your Dimmer may include three color options. The Dimmer ships
with the White frame attached. To change color of frame, proceed
as follows:
Installing Dimmer by itself or with other devices:
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER section. If installing Dimmer in a
multi-device application, proceed as follows:
MULTI-DEVICE APPLICATION:
In multi-dimmer installations, the reduction of the dimmer’s capacity
is required. Refer to the chart for maximum load per dimmer.
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER at circuit breaker or fuse and test
that power is off before wiring!
Identifying your wiring application (most
common):
NOTE: If the wiring in the wall box does not resemble
any of these configurations, consult a qualified electrician.
Step 2
Step 3
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
2
4
3
1
2
4
1
5
3
3-Way
1. Line or Load
(See important
instruction below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
NOTE: For matching remote w/LEDs
installation, the First Traveler becomes
Line Hot.
Step 4a
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green dimmer lead.
Line Hot wall box wire to Black dimmer lead.
Load wall box wire to Red dimmer lead.
Yellow/Red dimmer lead should have Red insulation label affixed.
NOTE: If insulating label is not affixed to Yellow/Red dimmer
lead, use electrical tape to cover.
Proceed to Step 5.
Pull off pre-cut insulation from dimmer leads.
Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
Remove insulation from each wire in the wall box as shown.
For Single-Pole Application, go to Step 4a.
For 3-Way Coordinating Remote (no LEDs) Application, go
to Step 4b.
WARNINGS AND CAUTIONS:
•To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any part of these instructions, consult a qualified electrician.
•To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-
operated appliance.
Use with incandescent or 120V halogen fixtures only.
•Vizia™ RF dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ RF remotes for multi-location dimming.
Use only one (1) Vizia™ RF dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or Vizia™ RF controllers. The remote(s) will turn the
light on at the brightness level selected at the dimmer.
WARNINGS AND CAUTIONS:
Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™).
•Total minimum load must exceed 40W.
Dimmer may feel warm to the touch during normal operation.
Recommended minimum wall box depth is 2-1/2".
Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
Use this device only with copper or copper clad wire. With aluminum wire use only devices marked
CO/ALR or CU/AL.
Single-Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
Step 4a cont’d
Strip Gage
(measure bare
wire here or use
gage on back of
the dimmer)
IMPORTANT:
For 3-Way applications, note that one of the screw
terminals from the old switch being removed will usually be a
different color (Black) or labeled Common. Tag that wire with
electrical tape and identify as the common (Line or Load) in both
the dimmer wall box and remote wall box.
5/8"
(1.6 cm)
Step 1
Cut
(if necessary)
3-Way Wiring with Coordinating Dimming
or Switching Remote (no LEDs)
Step 4b
Step 4b cont’d
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer
can be installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
Green or bare copper wire in wall box to Green dimmer lead.
Line Hot (common) wall box wire identified (tagged) when
removing old switch to Black dimmer lead.
First Traveler wall box wire to Red dimmer lead (note wire
color). This traveler from the dimmer must go to the terminal
screw on the remote marked “RD”.
Remove Red insulating label from Yellow/Red dimmer lead.
Second Traveler wall box wire to Yellow/Red dimmer lead (note
wire color). This traveler from the dimmer must go to the
terminal screw on the remote marked “YL/RD”.
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
Green or bare copper wire in wall box to Green terminal screw.
Load wall box wire identified (tagged) when removing old switch
to terminal screw marked “BK”.
First Traveler wall box wire (note color as above) to terminal
screw marked “RD”. This traveler from the remote must go to
the Red dimmer lead.
Second Traveler wall box wire (note color as above) to terminal
screw marked “YL/RD”. This traveler from the remote must go to
the Yellow/Red dimmer lead.
Remote terminal screw marked "WH" should have White
insulation label affixed.
NOTE: If insulating label is not affixed to terminal screw marked
"WH", use electrical tape to cover.
Proceed to Step 5.
Push in side at tab
to release Line up tabs and
press in side to
attach
More than
Cat. No. Single Two Devices 2 Devices
RZI1
Ø
1000W 800W 650W
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
(Coordinating Dimming Remote Depicted)
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B
Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment OFF and ON, the user is
encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving Antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/tv technician for help.
Compatible with enabled products!
TM
Remove
all inner
side
sections
Do not
remove
outer
side
sections
Preparing and connecting wires:
This dimmer can be wired using side wire terminal
screws or through backwire openings. Choose
appropriate wire stripping specifications accordingly.
WIRE NUT / # OF CONDUCTOR
COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 or 2 #16 or #18
1- #14 w/ 1 to 4 #16 or #18
2- #14 w/ 1 to 3 #16 or #18
For non-standard wiring applications, refer
to Wire Nut and Conductor Size Chart
4
3
2
1
Insulating Label:
This wire is used in 3-way installations only.
For single pole installations, do not remove this
insulating label.
Black
Green
Red
Yellow/Red
Dimmer
Hot (Black)
Neutral (White)
Load
Dimmer
Black
Black
White
Red
Green
Ground
Line
120VAC, 60Hz
Yellow/Red
Insulating
Label
BK
YL/RD RD
4
3
2
5
Black
Green
Red
Yellow/Red
1
Coordinating Remote
2
4
3
5
1
Dimmer
Hot (Black)
Neutral (White)
Load
Dimmer
Coordinating Remote (no LEDs)
YL/RD Yellow/
Red
RD
WH
Red
Black
BK
Black
Do not use for
incandescent
applications.
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
PRELIMINARY
Testing your Dimmer prior to mounting in
wall box:
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase
date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any
manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years.
Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Step 5
Restore power at circuit breaker or
fuse.
Press pad until locator light is OFF.
Lights should turn ON. If lights do not
turn ON, press the upper half of DIM/
BRIGHT bar until the lights brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
TROUBLESHOOTING
Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of dimmer
and/or remote.
- Local switch, ON
Light does not turn ON and Locator LED does not
turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
- Confirm that the device is being supplied from a 120V, 60Hz
AC source ONLY.
- Confirm that unit is programmed properly. Repeat “TO INSTALL”
section to verify that it has been included in the Z-Wave™
network.
Intermittent dimmer operation
- Minimum load is under 40W.
- Confirm that the Load being controlled does not exceed the
1000W dimmer limit.
Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
For additional information, contact Leviton’s Techline
at
1-800-824-3005
or visit Leviton's website at
www.leviton.com
NOTE: Dress wires with a bend as shown in diagram in order to
relieve stress when mounting device.
Position all wires to provide room
in outlet wall box for device.
Ensure that the word "TOP" is
facing up on device strap.
Partially screw in mounting screws
in wall box mounting holes.
Step 6 Including Scene Capable Dimmer into
Z-Wave™ Network:
NOTES:
If using a non-Leviton Programmer/Controller, refer to the
Programmer/Controller instruction sheet for Including a device.
A) If using a Leviton Z-Wave™ Programmer/Controller, Cat. No.
RZCPG, press the Menu button and scroll down to System
Setup. Press the center button to select System Setup Menu.
Press the center button to select Network.
Menu Button
B) While standing close to the module (approx. 2-5 ft), press the
center button to <Include> device in the network.
NOTE: Only one device may be included at a time. DO NOT
put multiple devices into the Inclusion mode at any time.
C) While the Programmer/Controller is in
the Inclusion mode and the Locator
LED is ON on the dimmer, push the
push pad to turn ON the dimmer. The
Programmer/Controller will verify
inclusion and the locator LED will turn
OFF on the dimmer.
If the dimmer is flashing Amber while
in the Inclusion mode, the
Programmer/Controller is still trying to
communicate with the dimmer. Wait
until the device stops flashing,then
press push pad.
NOTE: If the locator LED on the
dimmer turns solid Red while including, there has been a
communication error. Refer to Troubleshooting section.
D) The Primary Programmer/Controller wil assign a node ID
number (Name) for this module.
NOTE: This ID number (Name) will be stored in the controller
library to be used for future reference.
NOTE: You may name or edit the node of this device at this
time.
E) The dimmer is now installed in the network.
NOTE: If a dimmer has been successfully Included in the network
and the user tries to Include it again without first excluding it from
the network, the module will retain the first node ID it had received
and ignore the second.
Excluding Dimmer from Network:
NOTE: It is very important to accurately Exclude
devices from the network when moving or removing a
device from a Z-Wave™ network. This ensures that all
information has been removed from your Primary
Programmer/Controller’s information table and is not
counted on to be a part of the mesh network.
A) If using a Leviton Z-Wave™ Programmer/Controller, Cat.
No. RZCPG, press the Menu button and scroll down to
System Setup. Press the center button to select System
Setup Menu. Press the center button to select Network.
NOTE: Remote must be in close proximity to
dimmer when including in the network.
RZCPG
Programmer/Controller
Step 7
B) While standing close to the module, press the center
button to <Exclude> device from the network.
C) While the Programmer/Controller is in the Exclusion mode
and the locator LED is ON on the dimmer, press the push
pad on the dimmer. The Programmer/Controller will verify
Exclusion and the locator LED will turn OFF on the dimmer.
If the dimmer is flashing Amber while in the Exlusion mode,
the Programmer/Controller is still trying to communicate
with the dimmer. Wait until the device stops flashing, then
press the push pad.
Factory Default:
If your dimmer is not responding, or you are unable to control it after
you have tried to Include/Exclude it multiple times, it may be
necessary to reset the dimmer to its original factory settings. To
accomplish this, proceed as follows:
On the dimmer, engage he air-gap switch (refer to Operation
section) and wait 5 seconds. Press push pad back into frame
and hold push pad until the locator LED flashes Amber and turns
solid Red. The dimmer is now reset. Once the dimmer
is reset, it will be necessary to Re-Include it to a network before it
can be used.
CAUTION: SETTING A DEVICE TO A FACTORY DEFAULT DOES
NOT EXCLUDE THAT DEVICE FROM A NETWORK. THE
EXCLUSION PROCEDURE MUST STILL BE FOLLOWED TO
REMOVE THE DEVICE FROM THE PRIMARY CONTROLLER’S
INFORMATION TABLE. FAILURE TO DO SO MAY RESULT IN A
SYSTEM THAT IS SLOW TO RESPOND, OR MAY FAIL TO
RESPOND TO SOME DEVICES.
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Restore Power: Restore power at circuit breaker or
fuse. Installation is complete.
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
Step 8
OPERATION
NOTE: The locator light will illuminate
when the load is in the OFF position to
facilitate access in the dark.
NOTE: If using the dimmer in a 3-way
application, the lights will turn ON at
brightness set on dimmer's DIM/BRIGHT
bar. The lighting can be controlled from
either the dimmer or the remote location.
Gently lift bottom
of push pad out
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
Press and Hold until lights DIM to lowest level and LED in LED
Brightness Display starts to blink – Lights remain ON for 10
seconds and then turn OFF.
DIM/BRIGHT Bar
BRIGHTEN:
Press upper half of DIM/BRIGHT Bar Lights brighten to desired level.
DIM:
Press lower half of DIM/BRIGHT Bar – Lights dim to desired level.
If you continue to hold the lower half of the DIM/BRIGHT Bar, the
lights will DIM to minimum level and then turn OFF.
NOTE: When lights are OFF you can change the light level that the
lights will turn ON to using the DIM/BRIGHT Bar.
If there is a power outage, when the power
is restored the lights will return to the last
setting before the power interruption.
LED
Brightness
Display DIM/BRIGHT
Bar
Push
Pad Locator
Light
Step 9
Air-Gap Switch: On the dimmer only,
engage the air-gap switch by gently pulling
the bottom of the push pad until it lifts
completely out of the frame and a click is
heard and all LED’s are OFF (refer to
Figure). This will cut power to the fixture
to replace the bulb. After servicing is
complete, push the push pad back for
normal operation.
Cleaning: Clean with a damp cloth. DO
NOT use chemical cleaners.
ADVANCED PROGRAMMING FEATURES
Mode 1 – Set Minimum Brightness: Set the minimum brightness
level that the lights can dim to prior to turning full OFF.
Mode 2 – Set Dim-Lock: Set the brightness level that the lights
will turn on to regardless of the previous light level at which they
were turned OFF.
Mode 3 – Set Fade Rate: Set the amount of time (in seconds) that
the lights will have to turn ON or OFF. Fade rates can be set to
one of five different settings.
To Program:
NOTE: Have a flashlight handy if this dimmer
controls the only light source in the room.
1. On the dimmer only, engage the air-gap
switch by gently pulling the bottom of the
push pad until it lifts completely out of the
frame and a click is heard and all LED’s
are OFF.
2. Press push pad back into frame and hold
push pad for 7 seconds until the locator
light and the top LED (LED 1) starts
blinking.
3. Upon releasing the push pad, the locator
light will continue to blink once per second
indicating the dimmer is in Mode 1, Set
Minimum Brightness mode. To change
the current Minimum Brightness level from 1-50%, use the DIM/
BRIGHT Bar. This setting will automatically be saved.
4. Tap the push pad to change to Mode 2, Set Dim-Lock Level mode.
The locator light will blink twice per second. To change the current
Set Dim-Lock level from 1-100%, use the DIM/BRIGHT Bar. If this
feature is not desired, press and hold the lower half of the DIM/
BRIGHT Bar until no LED is lit. This setting will automatically be
saved.
5. Tap the push pad to change to Mode 3, Set Fade Rate mode. The
locator light will blink 3 times per second. To change the current
Fade Rate, use the DIM/BRIGHT Bar to move the LED to the
desired preset level. This setting will automatically be saved by
tapping the push pad to exit programming mode.
The LED Brightness Display is separated into 7 segments. Each LED
represents a preset level with LED 1 (Preset 1) located at the top and
LED 7 (Preset 7) located at the bottom. Refer to chart for settings and
defaults.
NOTE: The dimmer will exit program mode after 3 minutes of activity.
*default
** LED #1 is located at the top
*** The press and hold feature for the 10 second delayed off is
disabled in this mode.
Preset LED** Fade On Fade Off
1* 1 Approx. 1.5s from full off Approx. 3s from full on
2*** 2 No Fade No Fade
3 3 No Fade Approx. 3s from full on
4 4 Approx. 0.5s from full off Approx. 3s from full on
5 5 Approx. 0.5s from full off Approx. 1.5s from full on
6 6 Approx. 1.5s from full off Approx. 5s from full on
7 7 Approx. 1.5s from full off Approx. 10s from full on
Fade Rate Presets
Mode Description Range Default
1Set Min. Brightness 1-50% 25%
2Set Dim-Lock Level 0-100%, 0=no lock 0
3Select Fade Rate 1, 2, 3, 4, 5, 6 or 7 Preset #1
Advanced Features Summary
1
2
3
4
5
6
7
LED
Brightness
Display
DI-000-RZI10-00A-X0
U.S. & Foreign Patents Pending
Copyright© 2006 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
1
ON
2
ON
3
ON
4
ON
OFF
OFF
OFF
OFF
Programmer/Controller
Cat. No. RZCPG
Center Button
Final Fold Size
FOLD SCHEME
9.0¨
3.0¨
2.75¨
16.5¨
Fold Line
Panel Line
1
2
3
4
#'s = Fold Sequence
Cat. No.
Cat. No.
Cat. No.
56

Navigation menu