User Manual
Dip Switches 1-4
Single Pole (One Location)
Wireless Occupancy Sensor Products
Cat. No. WSS10, WSC04, WSC15, and WSS0S
Incandescent 800W @ 120V
Ballast 1200VAC @ 120V, 2700VA @ 277V
120-277VAC, 50-60Hz, Motor: 1/4 HP @ 120V
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• WSS0S Wireless Remote Switch can be used for additional switches (3-way and 4-way), no wires necessary.
WARNINGS AND CAUTIONS:
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
• Recommended minimum wall box depth is 2-1/2”.
Tools needed to install your Switch:
Slotted/Phillips Screwdriver Electrical Tape Pliers
Pencil Cutters Ruler
Wire Nuts
DIP SWITCH SETTINGS:
Manual ON / Auto ON mode: (factory: manual mode) Occupancy Sensor
WSC** - Auto mode can be enabled with the use of additional (3) AAA
batteries or a 5-24VDC connection.
Walk-through: On or Off (can be used only in Auto-ON mode)
Timeout: 2, 10, 20, 30min
Cat. No. WSS10 has a single switch pad that toggles the relay and its
corresponding load, ON and OFF. If the relay is OFF, the relay will turn
ON when the push-button is pressed, and remain ON in the presence of
motion. In the absence of motion, the Sensor Unit will Time-Out and turn
relay OFF. If in Auto ON/Manual OFF, time delay will start once space is
vacant.
NOTES:
• When the lights are on, the Motion Indicator LED will blink red (1 blink
per minute) every time motion is detected.
• When the Time-Out expires and the relay turns OFF, a 30 second
vacancy confirmation exists to turn the relay back ON.
• In Manual-ON mode, the button must be pressed to turn the lights ON.
In the absence of motion, the unit will Time-Out and turn the lights OFF.
LEARN MODE:
When using the Wireless Occupancy Products together, they must
LEARN the other devices to perform as desired.
• WSC04 and WSC15 – Wireless Occupancy Sensor – has learn button
on device, under front plastic tab
• WSS10 – Wireless Momentary Control Switch – use switch pad for
learning
• WSS0S – Wireless Remote Switch – use switch pad for learning
Programming – using Momentary Switch (WSS10)
• To enter programming, press and hold the switch pad for 15 seconds
• When in programming mode,
1 AMBER LED flash, 1 second pause = in programming
There are 2 modes in programming, LEARN and CLEAR modes. Tap the
switch pad to select which mode you would like.
• 1 AMBER LED flash = LEARN mode
• 2 AMBER LED flashes = CLEAR mode
Once you have selected the desired programming mode, press and hold
the pad again for 5 seconds to ENTER the desired mode.
• Learn mode:
• 1 Red flash = no learned devices
• 1 Green flash = 1 learned devices
• 2 Green flashes = 2 learned devices
• 3 Green flashes = 3 learned devices
• Etc. (up to 6 devices)
• On remote switch or occupancy sensor, you must press the switch pad
to send a signal for learning.
• AMBER LED on for 2 seconds = acknowledgement, device is
learned
• GREEN LED on for 2 seconds = device is unlearned
INSTALLING YOUR SWITCH
NOTE: Use check boxes when Steps are completed.
Changing the color of your Switch:
Color change kits are available from Leviton. To change color of frame,
proceed as follows:
Line up tabs and
press in side to attach
Push in side
at tab to release
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power is
off before wiring!
Step 1
BK WH
Black Wire (BK)
Blue Wire (BL)
4
2
White Wire (WH)
1
3
Single Pole Wiring Application:
Step 3a
2
4
3
1
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
Identifying your wiring application (most common):
NOTE: If the wiring in your wall box does not resemble this
configuration, consult a qualified electrician.
Step 2
Step 3b cont'd
Factory Settings: The sensor is shipped from the factory to work in almost
all situations, without any adjustments. The factory settings are: Manual
mode, when entering the room, the wireless momentary switch will need
to be turned ON. Wireless occupancy sensor will keep the lights on until
the room is vacant then turn the lights OFF after timeout period. The PIR
technology is active. Factory time-out is 10 min.
Time-Outs: The Sensor has four time-out settings: 2, 10, 20, or 30 min.
• Fixed Time-Out: The value of this time-out is user selected through the
use of the Dip Switch Settings.
Walk-Through Time Delay: The walk-through feature, which is only active
in the Auto-On mode, is useful when a room is momentarily occupied.
With this feature, the Sensor will turn the lights OFF shortly after the
person leaves the room. The walk-through feature works in the following
manner: When a person enters the room, the lights will turn ON. If the
person leaves the room before the walk-through time-out of 2.5 minutes,
the Sensor will turn the lights OFF within 2.5 minutes of no occupancy
detected. If the room is occupied for longer than 2.5 minutes, the Sensor
will enter the Occupied Mode with the time-out duration specified by the
Dip Switch setting.
Hot (Bla c k )
Neutral (White)
Load
Swit c h
BK WH
Bla c k
White
BL
Line
120 V A C , 60H z
WIRING SWITCH:
Connect wires per WIRING DIAGRAM below as follows:
• Connect (Hot) wire from wall box to black wire on switch.
• Connect (Load) wire in wall box to blue wire on switch.
• Connect (Neutral) wire in wall box to white wire on switch.
NOTE: For NO Neutral model, white wire will not be available.
NOTE: For 3-way applications, 4-way and more, use the
WSS0S Wireless Remote.
Step 3b cont'd
Single Pole Wiring Application:
Step 3b
NOTE: To access dip switch settings, lift up the bottom of the
switch pad.
DIP SWITCH SETTINGS
Dip Switch OFF Position ON Position
1 Auto ON/Manual OFF Manual ON
2 Walk Through OFF Walk Through ON
2 Min Time-Out OFF Position ON Position
3 X -
4 X -
10 Min Time-Out OFF Position ON Position
3 X -
4 - X
20 Min Time-Out OFF Position ON Position
3 - X
4 X -
30 Min Time-Out OFF Position ON Position
3 - X
4 - X
Step 3b cont'd
• Clear Mode
• 1 Red flash = no learned devices
• 1 Green flash = devices exist
• Press and hold the switch pad for >5 seconds. After the button is
released, the LED will flash red to confirm all learned devices have
been installed.
• Proceed to Step 4.
NOTE: Product will leave the learn or clear modes, without change, after
20 seconds of inactivity.
For additional information, contact Leviton’s
Techline at 1-800-959-6004 or visit Leviton’s
website at www.leviton.com
Covered by one or more US & Foreign
Patents and patents pending
Copyright© 2008 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,
at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability
for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or
implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
NOTE: Dress wires with a bend as shown in diagram in order to relieve
stress when mounting device.
• Restore power at circuit breaker or fuse.
• Press pad until locator light is OFF. Lights
should turn ON.
If lights do not turn ON, refer to the
TROUBLESHOOTING section.
• Position all wires to provide room in
outlet wall box for device.
• Ensure that the word “TOP” is facing
up on device strap.
• Partially screw in mounting screws
in wall box mounting holes.
Testing your Switch prior to mounting in
wall box:
Step 4
PK93663-10-00-0A
Push
Pad
Locator
Light
Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
Step 6
NOTE: The locator light will illuminate when the load is in the OFF position
to facilitate access in the dark.
Charge time: 2-4 minutes depending on strength of light source
Occupancy Sensor minimum light requirement: 40 LUX
Min 25W (No neutral version)
Auto ON: will function with out (3) AAA batteries for 24-48 hours. For
extended Auto ON feature, be sure to use batteries or 5-24VDC power
connection.
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON.
Turn OFF from ON position:
Tap – Lights turn OFF.
Cleaning: Clean with a damp cloth. DO NOT use chemical cleaners.
OPERATION
This device complies with part 15 of the FCC rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Any changes
or modifications not expressly approved by Leviton could void the user's
authority to operate this equipment.
FCC COMPLIANCE STATEMENT
TROUBLESHOOTING
• Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of switch
and/or remote.
• Light does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
LEARN
RANGE
WSC04/WSC15
WSS10
WSS0S
Switch Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Step 5
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
FOLD SCHEME
8.5"
14"
Cat No.
Cat No.
2.3"
4.25"
FINAL
Fold Line
DOCUMEN T A TIO N
LEVI T ON INSTRUCTION SHEET/MANUA L
SPECIFIC A TION S
H2D 10/04/07
Helvetica
DI-000-VZS15-02C
Black
7095512
Final fold size:
40 Lb. o f fse t
2.3" X 4.25"
Overall size:
14" X 8.5"
Paper size:
CD8 11/06/08
PK93663-10-00-0A