LifeShield SS470 Siren-Strobe User Manual 1 Regulatory Notices

LifeShield, Inc. Siren-Strobe 1 Regulatory Notices

User manual

Download: LifeShield SS470 Siren-Strobe User Manual 1  Regulatory Notices
Mirror Download [FCC.gov]LifeShield SS470 Siren-Strobe User Manual 1  Regulatory Notices
Document ID718941
Application IDoUIP/RS68U7flkOnOiJBzw==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize8.36kB (104473 bits)
Date Submitted2006-10-23 00:00:00
Date Available2006-10-23 00:00:00
Creation Date2006-10-13 17:26:45
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2006-10-13 17:27:13
Document Title1 Regulatory Notices
Document CreatorAcrobat PDFMaker 7.0 for Word
Document Author: W. Brown

Installation and Programming Guide
SS470 Auxiliary Siren-Strobe
SSC1000 Auxiliary Siren-Strobe
October 13, 2006 Draft
BHS-i100 Installation and Programming Instructions
Regulatory Notices ...........................................................3
1.1 FCC Rules Part 15.......................................................3
InGrid Component Installation and Registration ...............4
2.1 Components.................................................................4
2.2 Maximum System Capacity .........................................4
2.3 Wireless Communications Range................................4
2.4 Install the SS470 Siren-Strobe ....................................4
2.4.1 Wiring & Mounting the Siren-Strobe......................4
2.4.2 Wire the Power Supply..........................................5
2.4.3 Install the Battery...................................................5
2.5 Install/Learn Auxiliary Sirens........................................5
2.5.1 Learn The Auxiliary Siren ......................................6
2.5.2 Replacing Auxiliary Siren ......................................6
2.5.3 Auxiliary Siren Does Not Sound ............................6
2.5.4 Setting Options ......................................................6
2.5.5 Trouble Messages.................................................7
BHS-i100 Installation and Programming Instructions
1 Regulatory Notices
1.1
FCC Rules Part 15
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by InGrid, Inc.
can void the user’s authority to operate the equipment. This
equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable
protection against interference in a residential installation.
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If
interference generated by this unit is suspected, call Brink’s
Customer Care at 1-800-445-0872.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
•
•
•
Re-orient the radio/television antenna;
Move the television or receiver away from the unit.
Plug the unit and the TV/radio receiver into different outlets,
i.e. not on the same circuit breaker.
Contact Brinks Home Security or an experienced TV/Radio
technician for additional suggestions.
Part Number SS470; FCC ID: S9PSS470
Part Number SSC1000; FCC ID; S9PSS470
BHS-i100 Installation and Programming Instructions
2 InGrid Component Installation and Registration
Important Note
2.1
Please read and fully understand the BHS-i100
User’s Manual before reading this manual or
attempting to install the system. The User’s Manual
describes the system’s features, functions, and user
interface requirements in great detail. That
information is not repeated in this manual
Siren-Strobe to Grid Extender – This communication operates
at 345 MHz and 2.4 GHz. Communication from the InGrid
SS470 to Grid Extenders is two-way encrypted wireless.
SS470’s may communicate to any Grid Extender. The
maximum distance from a SS470 to the closest Grid Extender
must be less than 30 feet. Proper installation of the Grid
Extenders and SS470 is determined by using the Installation
and Registration Process.
Components
The SS470 Auxiliary Siren-strobe is designed for residential
applications. It is intended to be used as a supplementary
audible and visual signaling device when used with the BHSi100 Home Security System. It communicates using encrypted
two-way wireless signals. The only wired connection is power
via a plug-in power supply. A BHS-i100 system can contain the
following compatible components:
Grid Extenders
Brinks Keypad
Grid Extender
Brinks Programmer
Model Number
BK410
SE430
BP420
InGrid Sensors
Window/Door Sensor
Keychain Remote
Auxiliary Siren
Model Number
IS440
KF460
SS470
Ademco Transmitters
Glass Break Detector
Motion Detector
Smoke Detector
Model Number
5853
5800
5808LST
2.4
The SS470 Siren-Strobe must be mounted in a dry, clean
location.
The SS470 Auxiliary Siren-Strobe should be wall-mounted at a
height that provides the best possible audible and visual alarm
signaling. The BHS-i100 supports up to 4 SS470’s.
2.4.1 Wiring & Mounting the Siren-Strobe
Note: You must be free of static electricity before handling the
Keypad. Touch a bare metal surface or wear a grounding strap
to discharge yourself.
The SS470 is designed to be mounted on drywall or wood.
Mounting on metal studs, or any type of brick, stone, or
concrete block will likely reduce the wireless range of the
SS470.
Note: Compatibility between models KF460, 5816, and the
BP420 has not been evaluated by UL.
2.2
Maximum System Capacity
Note: Do NOT use an outlet that is controlled by a switch.
The maximum number of Auxiliary Siren-Strobe devices in a
single system is 4. The Auxiliary Siren-Strobe is intended to be
used only with the BHS-i100 system. Each BHS-i100 system
must contain at least 1 Brinks Keypad and at least 1 Signal
Extender to support the addition of a SS470 Auxiliary SirenStrobe.
2.3
Install the SS470 Siren-Strobe
Location
Select a location on a wall that is accessible to an outlet that is
not controlled by a switch.
Mount at height convenient for use, typically 55 to 60 inches
above the floor. A wire must be run from the SS470 to the
Power Supply, so choose the location wisely to minimize the
difficulty of running the wire.
Wireless Communications Range
There are two types of wireless communications used in a BHSi100 system:
The mounting plate must be used for the SS470 to operate
properly.
Grid Extender to Grid Extender – This communication
operates at 2.4 GHz. To avoid the potential for conflict with
WiFi networks, it is good installation practice to locate any Grid
Extender at least 10 feet from a WiFi router that a customer
may be using. The Grid Extenders installed in a single
customer’s home, garage, and shed work together in a
redundant grid network. If you were to draw a circle around all
of the Grid Extenders in a single grid network, the maximum
diameter of that circle must be less than 300 feet. The InGrid
system will ensure installation within the acceptable range.
BHS-i100 Installation and Programming Instructions
does not receive power from the Power Supply, switch
the polarity of the wire connections on the Power Supply.
5. The Power Supply contains a tab that protrudes above
the Power Supply. The Power Supply must be mounted
so that the hole in the tab is aligned with the center screw
hole of the outlet cover. This may require changing the
vertical orientation of the Power Supply in order to find
the direction which permits the hole in the tab to align
with the center screw hole of the outlet cover.
6. Insert the outlet screw through both the tab and the
center screw hole of the outlet cover, and tighten. The tab
and the cover should be snug against the outlet, but not
so tight that it causes flexing or stress on either the tab or
the outlet cover.
7. Reconnect power to the outlet by turning the circuit
breaker on or replacing the fuse.
Note: Connect the transformer using 18 AWG or larger wire.
Mounting
1.
Hold mounting plate level up to the wall where the
SS470 will be mounted and mark area for wires to run
through wall.
Use the mounting
plate as a template
for making a hole for
running wires to the
power supply
Figure 1
2.
3.
4.
5.
Make hole in wall. Run wires (18 gauge stranded
wire) from the mounting location of the SS470 to the
outlet where the Power Supply will be mounted.
Mount the SS470 mounting plate to the wall using #8
drywall screws.
Attach the wires to the power terminals of the SS470.
If the wire is color coded, note the attachment color
used for the positive terminal of the SS470. This
same color wire should connect to the positive
terminal of the Power Supply. The SS470 has a
protection circuit in case the wires are connected with
the wrong polarity. Later, when the Power Supply is
mounted, if the Siren-Strobe does not receive power
from the Power Supply, switch the polarity of the wire
connections on the Power Supply.
Snap the SS470 onto the back plate, by inserting the
tabs on the mounting plate into holes on the back of
the Siren-Strobe. If any pressure or difficulty is
encountered, do not apply force. Investigate the
routing of the wires and the alignment of the SS470
and the mounting plate and try again.
Wiring Diagram SK-WIR-002 for the BS450 Power Supply
The power supply is intended to be correctly orientated in a
vertical or floor mount position.
2.4.3 Install the Battery
NOTE
Install the InGrid IG120 rechargeable battery pack into the
Siren-Strobe and allow charging for at least 24 hours to ensure
that it is fully charged.
2.4.2 Wire the Power Supply
Note: You must be free of static electricity before handling the
Power Supply. Touch a bare metal surface or wear a grounding
strap to discharge yourself.
Use the Brinks BS450 Power Supply to provide power to the
Auxiliary Siren-strobe.
BS450 Specifications:
Input: 120V 60Hz
Output: 5VDC 850mA
1.
2.
3.
4.
To avoid risk of shock or fire, install only InGrid
IG120 battery.
Select an outlet on which to mount the Power Supply.
Choose an outlet that is close to the location where the
Keypad is mounted.
Find the circuit breaker or fuse controlling the outlet to
which the Power Supply will be mounted and disconnect
power to the outlet by turning the circuit breaker off or
removing the fuse.
Remove the center screw attaching the outlet cover to
the outlet.
Attach the wires to the Power Supply terminals, noting
the polarity of the wire colors (if any). The Power Supply
generates a polarity sensitive +5 volts DC. If the Keypad
1.
Connect the battery pack to the Siren-Strobe connector in
the battery compartment. Match the battery connector's
polarity to the Siren-Strobe polarity. Push the battery
pack connector and Siren-Strobe connector together until
they click into place.
2.
Make sure you have a good connection by gently pulling
on the battery wires.
3.
Route the wires under the battery pack and place the
battery pack in the compartment
2.5
Install/Learn Auxiliary Sirens
Occasionally, one or more Auxiliary Sirens are needed. This
may occur if the layout of the home prevents the Keypad sirens
from adequately reaching all areas of the home or if residents
suffer from hearing loss. Up to four (4) Auxiliary Sirens may be
installed on a system. If an Auxiliary Siren is necessary, it
should be mounted in a location that will enable all occupants of
the household to hear the siren.
BHS-i100 Installation and Programming Instructions
4.
2.5.1 Learn The Auxiliary Siren
1.
Using the Programmer, navigate to “Learn Devices”, then
“Learn Auxiliary Siren”. Registration will be enabled for 60
seconds only. The Programmer will display:
Assign Siren to
Siren #1?
1=YES
2=NO
Install Siren on
Mounting Bracket
To Register
2.
If the Auxiliary Siren successfully qualifies, the
Programmer will display:
5.
The process may be repeated until all Auxiliary Sirens
are registered.
2.5.2 Replacing Auxiliary Siren
Install the Siren on the mounting bracket. This will set the
tamper switch and learn the siren. If successful, the
Programmer will display:
To replace a defective auxiliary siren:
1.
Syncronizing
Please Wait
Install the new Siren-strobe, use Advanced Menu |
Device | Auxiliary Siren | Choose Device | Replace
Siren to configure the new auxiliary siren the same way
the existing auxiliary siren was configured. Refer to
section 2.5.5
2.5.3 Auxiliary Siren Does Not Sound
Please Hold Test
Button for 3 Sec’s to
Complete Registration
Condition: The siren is malfunctioning.
Indications: The siren does not sound when or as it should.
If successful, continue to step 3.
Possible causes:
•
No AC power to the siren.
•
No battery in the siren.
•
The siren was not learned into the system.
•
The system is improperly programmed.
If unsuccessful, the programmer will display:
Error: No Siren
Detected
Press ENTER
To Continue
3.
Solutions:
•
Verify AC power connections to the siren. Press the test
button on the siren to verify sound and/or strobe.
•
Verify that the siren is listed in the Advanced | Device |
Auxiliary Siren Menu.
•
Verify that the system is programmed as follows:
the alarm cadence is correct;
the alarm cutoff time is correct;
•
If these solutions are not effective, replace the siren.
Press and hold the test button on the siren for 3 seconds.
If the Auxiliary Siren fails to register within 60 seconds, the
Programmer will leave registration mode automatically. If a
system detects two registration bursts during the Auxiliary Siren
registration mode it will not register either Auxiliary Siren and
the Programmer will leave registration mode automatically.
The registration must be confirmed by pressing ENTER.
2.5.4 Setting Options
If successful the Programmer will then display:
The Siren-strobe may be configured with System Level Options
and Device Level Options.
External Siren
REGISTERED
Press ENTER
to continue
System Level Options:
Using the programmer, enter the advanced menu and select
Global. In the Global menu, select System. There will be two
System Level Options to be configured:
If unsuccessful, the Programmer will then display:
Siren
NOT REGISTERED
Press ENTER
to continue
Strobe Enable
Default value: No
Select Yes -- will enable the strobe for all devices on the
system.
If the Auxiliary Siren fails to qualify, the Programmer will return
to the “Learn Devices” menu.
Strobe Latching
Default value: No – the strobe stops flashing when the siren
stops sounding.
Select Yes -- the strobe continues flashing when the siren stops
sounding.
BHS-i100 Installation and Programming Instructions
Device Level Options
Using the programmer, enter the Advanced Menu and select
Device. In the Device Menu, select Auxiliary Siren. Select the
Siren (#1 - #4) to be configured. There will be 6 Device Level
Options to be configured for each Siren installed on the system.
Enable
Default value: Yes – enables the device
Select No – disables the device
Assign Name
Default value: “External Siren”
Use key pad to change name
Chime Tone Enable (System door chime mode must be
enabled)
Default value: Yes – allows door chime to play
Select No – chime will not play
Exit Tone Enable
Default value: Yes – tone plays during exit delay
Select No – no tone during exit delay
Entry Tone Enable
Default value: Yes – tone plays at Siren until code is entered
Select No – no tone at Siren during code entry
Alarm Tone Enable
Default value: Yes – Siren sounds during alarm
Select No – Siren does not sound during alarm
2.5.5 Trouble Messages
Trouble Messages will appear to indicate the following:
59
Not Ready
S01 – S04 Low Bat (rotating status)
S01 – S04 No AC (rotating status)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Company                         : Susan Friedman Limited
Source Modified                 : D:20061013212406
Creator Tool                    : Acrobat PDFMaker 7.0 for Word
Modify Date                     : 2006:10:13 17:27:13-04:00
Create Date                     : 2006:10:13 17:26:45-04:00
Metadata Date                   : 2006:10:13 17:27:13-04:00
Document ID                     : uuid:2543b939-bd4d-4679-a564-934626d6a8c5
Instance ID                     : uuid:db5d2d7f-55c0-41cc-94a0-078187455384
Version ID                      : 4
Format                          : application/pdf
Title                           : 1  Regulatory Notices
Creator                         : W. Brown
Subject                         : 
Headline                        : 
Page Count                      : 7
Page Layout                     : OneColumn
Author                          : W. Brown
EXIF Metadata provided by EXIF.tools
FCC ID Filing: S9PSS470

Navigation menu