RESET SWITCH/MANUAL DISCONNECT
The reset switch is located on the front of the operator and serves several functions. When referring to “toggling”
the reset switch it means pressing the reset switch to the RESET/DISCONNECT position, then back to the NORMAL
OPERATION position.
Toggling the reset switch will stop a moving gate during a normal open/close cycle, like a stop button. The operator
does not need to be reset after doing this. The reset switch will disable the gate in the present position and will
energize the solenoid lock for two minutes and disable the maglock for two minutes.
OPERATION
Thank you for purchasing a LiftMaster gate operator.
Our operators are designed to meet or exceed UL325
safety standards and requirements and are quality
manufactured for years of safe and reliable service.
Think LiftMaster for all of your Access Control needs.
MODEL CSL24V SLIDE GATE
OPERATOR
Press the reset switch to RESET/
DISCONNECT to allow the gate to be
opened and closed manually. To
resume normal operation press the
reset switch to NORMAL OPERATION.
MODEL CSW24V SWING GATE
OPERATOR
Press the reset switch to RESET/
DISCONNECT. Release the handle on
the operator arm to allow the gate to
be opened and closed manually. On a
dual gate application the handle must
be released on both operators. To
resume normal function tighten the
handle by pushing it down.
RESET/DISCONNECT
NORMAL OPERATION
Manual Disconnect
Handle
RESET/DISCONNECT
NORMAL OPERATION
2
REMOTE CONTROL
Once the remote control has been programmed operator will operate as follows:
When gate is in the closed position, activation of the remote control button will open the gate. During the open cycle
another activation of the remote control will stop the gate and the next activation of the remote control will close
the gate. When the gate is in the open position, activation of the remote control button will close the gate. If the
remote control is activated while the gate is closing, the gate will stop and the next activation will open the gate.
If a contact sensor detects an obstruction twice consecutively the alarm will sound
(up to 5 minutes) and the operator will need to be reset. If a command is given
after the initial 5 minutes the operator will beep.
The gate does not meet
specifications.
Debris is on the gate's track
such as mud, rocks, dirt, etc.
(Slide Only)
The gate has one or more
broken axles or wheels.
(Slide Only)
The gate wheel is off the gate
rail. (Slide Only)
The gate is hitting a wall or
vehicle.
Remove any obstructions. Toggle the reset switch to shut off the alarm and reset the operator. After the operator is
reset, normal functions will resume.
When the inherent force of the operator (RPM/current
sensor) detects the following (twice consecutively) the
alarm will sound (up to 5 minutes) and the operator
will need to be reset:
Gate hinges are too tight or
broken and the gate is not
moving freely. (Swing Only)
The gate is moving and a car
pushes the gate.
(Swing Only)
A foreign object is on the gate
frame while the gate is moving.
(Swing Only)
The gate hits the driveway, curb
or other, and gets stuck or bent
in an awkward position.
(Swing Only)
OPERATOR ALARM
The operator arm or gate is
incorrectly installed.
(Swing Only)
OPERATION
3
MAINTENANCE
The following should be checked by an authorized LiftMaster dealer:
BATTERIES
Batteries will degrade over time depending on temperature and usage. For best performance, the batteries should
be replaced every 3 years. Use only LiftMaster part 29-NP712 for replacement batteries. The operator comes with
two 7AH batteries. Two 33AH (A12330SGLPK) may be used in place of the 7AH batteries.
The batteries contain lead and need to be disposed of properly. Batteries do not perform well in extremely cold
temperatures.
NOTE:
If your application includes a heater, two 33AH will not fit into the operator enclosure (swing only).
The operator alarm will beep 3 times with a command if the battery is low.
DRIVE CHAIN (SLIDE ONLY)
Over time, the drive chain on the operator will stretch and need to be tightened. To tighten the drive chain adjust
either of the two chain eye bolts.
NOTE: The chain should have no more than 1 inch of sag for every 10 feet of chain length.
CHECK AT LEAST ONCE EVERY MONTH
DESCRIPTION TASK
Entrapment Protection Devices Check and test for proper operation
Warning Signs Make sure they are present
Gate Inspect for wear or damage
Drive Chain (Slide Only) Check for excessive slack and lubricate
CHECK AT LEAST ONCE EVERY
DESCRIPTION TASK 6 MONTHS 3 YEARS
Manual Disconnect Check and test for proper operation X
Sprockets and Chains Check for excessive slack and
lubricate
X
Belt and Pulley (Slide
Only)
Check for excessive slack, wear, or
damage
X
Accessories Check all for proper operation X
Electrical Inspect all wire connections X
Chassis Mounting Bolts Check for tightness X
Operator Inspect for wear or damage X
Batteries Replace X
4
ACCESSORIES
PHOTOELECTRIC SENSORS (NON-CONTACT)
The photoelectric sensors are designed to detect an obstacle in the path of the
electronic beam and stop the operator. Includes mounting brackets.
Models AOMRON E3K-R10K4-NR (retro-reflective), RETROAB 60-2728
(retro-reflective), CPS-UN4 (through beam)
ENTRAPMENT PROTECTION DEVICES
REMOTE CONTROLS
Chamberlain offers a variety of LiftMaster remote controls to satisfy your application needs. Single-button to
4-button, visor or key chain. The following remote controls are compatible with operators manufactured by
Chamberlain after 1993. Contact your authorized LiftMaster dealer for additional details and options.
3-BUTTON REMOTE CONTROL
The 3-button remote control can be programmed to control the operator. Includes
visor clip.
Model 893MAX
3-BUTTON MINI-REMOTE CONTROL
The 3-button remote control can be programmed to control the operator. Includes
key ring and fastening strip.
Model 890MAX
SENSING EDGE (2-WIRE, NON-MONITORED, CONTACT)
Sensing edges can detect an obstacle upon contact and stop the operator.
Models G65MG0204, G65MG0205, G65MGR205, and G65MGS205
SENSING EDGE CHANNEL
Mounting channel for all MG020 type edges.
Model G65ME120C5
KEYLESS ENTRY
Enables homeowner to operate gate operator from outside by entering a 4-digit
code on a specially designed keypad.
Model 877MAX
5
MISCELLANEOUS
REMOTE ANTENNA EXTENSION KIT
The remote antenna extension kit allows the antenna to be remotely installed.
Model 86LM
WIRELESS ACCESS CONTROL RECEIVER
Access control receiver for up to 450 remote controls.
Model STAR450-315
HEATER
Keeps operator, gearbox and batteries at suitable temperature when outside
temperature is below 0°F for extended periods of time.
Models HTRKITRSW (for Swing operator, includes bracket for optimal heater
location) and G6518CSW (Swing replacement heater only)
Models HTRKITRSL (for Slide operator, includes bracket for optimal 7AH battery
location) and G6518SL (replacement heater only)
LOOP DETECTOR
Low power loop detectors.
Model LD7LP
ACCESSORIES
POST-MOUNTING PLATE
For post-mounting commercial slide/swing operators. Posts not included.
Model MPEL
PLUG-IN LOOP DETECTOR
Conveniently plugs into existing control board.
Model LOOPDETLM
6
SOLAR PANEL KIT - 10 WATT
This kit is to replace or add a solar panel to the operator application. Up to three
solar panels can be connected to the operator.
Model SOLPNL10W12V (requires 2 minimum)
SOLENOID GATE LOCK
The automatic gate lock is a solenoid-driven lock that automatically unlocks when
the gate is open and locks when the gate is closed. Can be mounted onto a gate or
post. Can be released in case of emergency.
Models GC824 (115 Vac) and CC824-12 (12/24 Vac/dc)
BATTERY FOR GATE ACCESS SYSTEMS
Gate access system batteries replace or upgrade the gate operator batteries.
Model 29-NP712 (standard 7 AMP-Hour Battery, 12 Vdc, to replace original
batteries provided with operator, reuse existing harnesses)
Model A12330SGLPK (upgrade 33 AMP-Hour Battery, 12 Vdc, includes 33AH
harness. Ideal for solar applications and extended battery backup)
Two identical 12 Vdc batteries are required for each gate operator. Do not mix 7AH
and 33AH batteries within a gate operator.
Model K75-34986-2 (battery tray for slide operator)
Model 10-36183 (battery tray for swing operator)
MAGNETIC GATE LOCK
Outdoor magnetic lock, transformer, junction box, mounting plate and hardware.
Not for use with Solar Applications. Must be powered separately.
Model MG1300
ACCESSORIES
VEHICLE SENSING PROBE
The vehicle sensing probe is buried in the ground and can detect a car as it
approaches and will then open the gate.
Model CP3
845 Larch Avenue
Elmhurst, Illinois 60126-1196
01-35591 © 2011, The Chamberlain Group, Inc. – All Rights Reserved