QuickStart

™

for single gate applications

This QuickStart is intended to highlight a single right-hand gate application. Each application is unique and it is the responsibility of the purchaser, installer and end user to ensure that the
total gate system is installed and operated properly. Refer to the installation manual for complete information regarding installation, testing, and programming.

INSTALLATION
1 Install the concrete pad and conduit.
2 Attach the operator to the concrete pad.
3 Attach the gate brackets to the gate.
4 Close the gate.
5 Route the chain through the operator.
6 Connect the chain to the gate brackets.
7 Remove the pin from the vent plug on the gear box.

INSTALL THE COVER
1 Align the tabs on the rear cover with the slots on the chassis

7

4

and place the cover over the operator.

2 Secure both sides of the rear cover to the chassis with two
5/16-18 hex bolts and washers.

3 Align the front cover with the back cover, making sure the
grooves line up.

4 Secure the front cover to the chassis with two 5/16-18 hex
bolts and washers.

5 Secure the front cover to the rear cover using the 5/16-18
screw.

5

5/16-18
Screw

Tabs on Rear Cover

Close the gate BEFORE installing the chain.

5/16-18
Hex Bolts
and Washers

3
6

Slots on Chassis

3

1
2

6

™

MODEL CSL24V & CSL24VH

Groove on Front Cover

WIRING

INITIAL LIMITS AND FORCE ADJUSTMENT

1

To protect against fire and electrocution:
• DISCONNECT power and battery BEFORE
installing or servicing operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and
rating.

WIRE THE ENTRAPMENT PROTECTION DEVICES
Connect the entrapment protection device to the EYES EDGE terminal on the control
board.
• Close Photoelectric Sensor Entrapment Protection: Connect wires from the
photoelectric sensors to the Inputs on the CLOSE EYES/INTERRUPT terminal.
• Close Edge Entrapment Protection: Connect wires from the entrapment protection
device to the Inputs on the CLOSE EDGE terminal.
• Open Entrapment Protection: Connect wires from the entrapment protection device
to the Inputs on the OPEN EYES/EDGE terminal.

5

1 Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.
2 Press and hold one of the MOVE GATE buttons to move the gate to the
open or close limit.

PRESS &
RELEASE
TO BEGIN

3 Press and release the SET CLOSE or SET OPEN button
depending on which limit is being set.

4 Press and hold one of the MOVE GATE button to move the

TO BEGIN

LIMIT

PRESS &
RELEASE
TO BEGIN
RESET

LIMIT
SETUP

MOVE
GATE

ALARM

5

gate to the other limit.

SET OPEN SET CLOSE

STATUS:

INPUT POWER

OFF
RESET

ALARM

AC Power Switch

PRESS &
RELEASE
TO BEGIN

LIMIT

4

When limits are set properly the operator will automatically exit limit setting mode.

1 Connect the battery wires to the
2 Turn ON AC power to the
operator.

limit is being set.

6 Cycle the gate open and close. This automatically sets the force.

CONNECT BATTERIES
J15 plug on the control board.

5 Press and release the SET CLOSE or SET OPEN button depending on which

+
BATT

3 Turn ON the AC power switch on

FINE TUNE THE FORCE

+
DC

1 Open and close the gate with the test buttons.

XMITTER
NETWORK

CLOSE

Black Wire

Jumper

OPEN

6

Red Wire

the operator.

The FORCE DIAL on the control board is used for fine tuning the force. The force setting should be high enough that
the gate will not reverse by itself nor cause nuisance interruptions, but low enough to prevent serious injury to a
person. The force setting is the same for both the open and close gate directions.

STOP

2 If the gate stops or reverses before reaching the fully

open or closed position, increase the force by turning the
force control slightly clockwise.

NETWORK

RESET

3

POWER WIRING

2

This operator can be wired for either 120 Vac or 240 Vac or a
solar panel (not provided). These instructions show a 120 Vac
application. For information regarding a 240 Vac or solar
application refer to the installation manual.

1 Turn off the AC power from the main

3 Perform the “Obstruction Test” after every force setting adjustment (see below).

EARTH GROUND ROD

1 Install the earth ground rod within 3 feet
2

of the operator.
Run wire from the earth ground rod to the
operator.

power source circuit breaker.

2 Run the AC power wires to the

60
180 MIN

MAX

BATT LOW

OBSTRUCTION TEST

7

1 Open and close the gate with the test buttons, ensuring that the gate is stopping at the proper open and close limit
positions.

2 Place a solid object between the open gate and a rigid structure. Ensure that the gate, the solid object, and the rigid
structure can withstand the forces generated during this obstruction test.

3 Run the gate in the close direction. The gate should stop and reverse upon contact with the solid object. If the gate

operator.

3 Connect the green wire to the earth

does not reverse off the solid object, reduce the force setting by turning the force control slightly counter-clockwise.
The gate should have enough force to reach both the open and close limits, but MUST reverse after contact with a
solid object.

ground rod and AC ground using a
wire nut. NOTE: The earth ground
rod can be grounded to the chassis.

Check national and local
codes for proper depth

4 Connect the white wire to NEUTRAL
using a wire nut.

4 Repeat the test for the open direction.
PROGRAMMING

8

5 Connect the black wire to HOT using
a wire nut.

Junction Box

01-35590

ALARM

©2011 The Chamberlain Group, Inc.
All Rights Reserved

1 Press and release the LEARN
button (operator will beep
and green XMITTER LED will
light).

2 Press the remote control button for the
desired function. The
operator will automatically
exit learn mode (operator
will beep and green
XMITTER LED will go out)
if programming is
successful.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract, Print high-res
Page Mode                       : UseOutlines
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2013:09:10 09:03:16-07:00
Create Date                     : 2011:08:12 09:51:07-07:00
Metadata Date                   : 2013:09:10 09:03:16-07:00
Format                          : application/pdf
Title                           : QUICKSTART CSL24V CSL24VH
Creator                         : The Chamberlain Group, Inc.
Description                     : QUICKSTART CSL24V CSL24VH
Subject                         : CSL24V CSL24VH
Document ID                     : uuid:2113eef9-cd46-b447-a111-b073a202f4b3
Instance ID                     : uuid:1db7f15f-f8d7-4914-9bf7-b83b323ef3f1
Keywords                        : CSL24V CSL24VH
Has XFA                         : No
Page Count                      : 2
Author                          : The Chamberlain Group, Inc.
EXIF Metadata provided by EXIF.tools

Navigation menu