Liftmaster Mt Owners Manual 01 34215

Liftmaster-Mhs-Owners-Manual liftmaster-mhs-owners-manual

Liftmaster-Mgj-Owners-Manual liftmaster-mgj-owners-manual

Liftmaster-Mj-Owners-Manual liftmaster-mj-owners-manual

2014-07-19

: Liftmaster Liftmaster-Mt-Owners-Manual liftmaster-mt-owners-manual liftmaster pdf

Open the PDF directly: View PDF PDF.
Page Count: 12

DownloadLiftmaster Liftmaster-Mt-Owners-Manual 01-34215
Open PDF In BrowserView PDF
MEDIUM DUTY LOGIC

USER’S GUIDE
MH 5011E
MHS 5011E

MT 5011E
BMT 5011E

MGJ 5011E

MJ 5011E

Contact Information

Radio Receiver
Built on Board
Installation Date

www.liftmaster.com

315MHz

INTRODUCTION
Congratulations on purchasing a quality, LiftMaster Medium Duty
Commercial Door Operator. Your new operator is capable of
operating up to 12 cycles per hour or 50 cycles per day. It is
equipped with a built in radio receiver that is compatible with our

existing 315 MHz product line as well as a Timer To Close (TTC)
feature that can be enabled when LiftMaster Commercial Protector
System® is installed and aligned properly.

BASIC PROGRAMMING
DETERMINE THE WIRING TYPE

CAUTION

The functionality of this operator is based on the wiring type. The
operator is shipped from the factory in standard C2 wiring type
(factory default). Some wiring types will require an optional safety
device. Refer to the following descriptions of wiring types,
requirements and programming.

To prevent possible SEVERE INJURY or DEATH, install reversing
sensors when:
• The radio is used.
• The 3-button control station is out of sight of the door.
• Or ANY other control (automatic or manual) is used.
Reversing devices are recommended for ALL installations.

NOTE: 1. The LED on the logic board will blink once when in C2
and twice when in B2.
2. The operator will automatically convert to B2 wiring (option
D) when Monitored Safety Device is installed. If the
Monitored Safety Device is removed, the operator will go
into a Restricted Close mode**. Turn power OFF and ON to
reset wiring type.
** Restricted close mode requires a constant pressure close
command. The operator will begin closing after a 5 second delay
and will continue to close to the close limit switch. The operator
will stop if the pressure to close is released before reaching the
close limit.

A

WARNING

AVERTISSEMENT

C2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE
(Factory Default)

B

• Momentary contact to open and stop with constant
pressure to close.
• Open override that reverses when closing by any opening
device.
• Wiring for safety device to reverse. NOTE: The operator
will automatically convert to B2 wiring (option D) when
Monitored Safety Device is installed. (See accessories
page for Monitored Safety Devices)
• Timer to Close (TTC) feature not available.
NON-MONITORED SAFETY DEVICE

ATTENTION

C2 WIRING TYPE WITH MONITORED SAFETY DEVICE

• Momentary contact to open and stop with constant
pressure to close.
• Open override that reverses when closing by any opening
device.
• Wiring for safety device to reverse. NOTE: The operator
will automatically convert to B2 wiring (option D) when
Monitored Safety Device is installed. (See accessories
page for Monitored Safety Devices)
• Timer to Close (TTC) feature not available.
MONITORED SAFETY DEVICE

ADVERTENCIA
Sensing
Edge

Photo Eye

PRECAUCIÓN

RESET TO C2 WIRING TYPE (Factory Default)
Remove any monitored safety devices.
Disconnect then reconnect power to the operator.
Press and hold the LEARN and STOP buttons until the LED goes
out (approximately 3 seconds).
Electrical Box

TO PROGRAM
Press and hold the LEARN and CLOSE buttons until the LED goes
out (approximately 3 seconds).

Logic Board

Electrical Box
LEARN

STOP

Logic Board

CLOSE OPEN

LEARN

D14
LED
D7
U4 D6

014A1030
C20

D4

D7
U4 D6

R25

014A1030
C20

TP1

L5

D5
D4

J4
C32
R25

C9

^^^^

C31

U1

C21

CLOSE OPEN

C32

C31

TP1
C9

AUX
AUX ANT
ANT

STOP

D14
LED

D5

J4

U1

C21
C18
R27

J2

L5

LEARN STOP CLOSE OPEN
LED

D9

^^^^

AUX
AUX ANT
ANT

D14

TTC
1

2

3

4

5

6

7

LMEP1

LMEP2

COM

INTRLK

STOP

CLOSE

OPEN

K2
LT
C29
R24
P1

C18

1

2

3

4

5

6

R27

J2

7

D14

TTC

LEARN STOP CLOSE OPEN
LED

D9

2

1

2

3

4

5

6

7

LMEP1

LMEP2

COM

INTRLK

STOP

CLOSE

OPEN

K2
LT
C29
R24
P1

1

2

3

4

5

6

7

BASIC PROGRAMMING
B2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE

C

D

Requires a non-monitored safety device.
• Momentary contact to open, close and stop.
• Open override that reverses when closing by any opening
device.
• Wiring for safety device to reverse. NOTE: The operator
will automatically convert to B2 wiring (option D) when
Monitored Safety Device is installed. (See accessories
page for Monitored Safety Devices)
• Timer to Close (TTC) feature not available.

B2 WIRING TYPE WITH MONITORED SAFETY DEVICE

• Momentary contact to open, close and stop.
• Open override that reverses when closing by any opening
device.
• Wiring for safety device to reverse. NOTE: The operator
will automatically convert to B2 wiring when Monitored
Safety Device is installed. (See accessories page for
Monitored Safety Devices)
• Timer to Close (TTC) feature available.

NON-MONITORED SAFETY DEVICE

MONITORED SAFETY DEVICE

Sensing
Edge

Photo Eye

TO PROGRAM

NO PROGRAMMING REQUIRED

Start with operator in factory default C2 mode.
Press and hold the LEARN and CLOSE buttons until the LED goes
out (approximately 3 seconds).
Electrical Box

Logic Board

D7
U4 D6

014A1030
C20

D5
D4

J4
C32
R25
C31

TP1
C9

U1

C21

LEARN

L5
^^^^

AUX
AUX ANT
ANT

C18
R27

J2

STOP

CLOSE OPEN

D14

TTC

LEARN STOP CLOSE OPEN
LED

D9

1

2

3

4

5

6

7

LMEP1

LMEP2

COM

INTRLK

STOP

CLOSE

OPEN

K2
LT
C29
R24
P1

D14
LED

1

2

3

4

5

6

7

3

BASIC PROGRAMMING
REMOTE CONTROLS

TIMER TO CLOSE (TTC)

SINGLE BUTTON REMOTE CONTROL
Built in 315 MHz radio receiver permits as many as 20 Security✚®
remote controls or dip switch remote controls in any combination.

Timer to Close feature enables the operator to close from the open
limit after a preset time, adjustable from 5 to 60 seconds.
Requires LiftMaster monitored safety device.

TO PROGRAM
1. Press and release the LEARN button (LED will light).
2. Press and hold the button on the remote control until the LED
flashes rapidly, then release to complete programming (LED
will go out).
3. Repeat steps 1 and 2 for additional remote controls.

TO PROGRAM
1. Begin with door in fully closed position.
2. Press and release the LEARN button (LED will light).
3. Press and release the TTC button.
4. Every press and release of the STOP button will add 5 seconds
to the Timer to Close. Example: 30 second TTC = 6 presses of
the STOP button.
5. Press and release the TTC button to exit programming mode.
6. The LED will flash once per 5 seconds of timer setting.
The TTC will become active after completion of the next open
cycle.

Electrical Box

Logic Board

STOP

LEARN

CLOSE OPEN

D14
LED
D7
U4 D6

NOTE: The LED does not indicate that timer is running.

D5
D4

J4

014A1030

C32

C20

R25
C31

TP1
C9

U1

C21

L5
^^^^

AUX
AUX ANT
ANT

C18
R27

J2

K2
LT

LEARN STOP CLOSE OPEN

C29
R24
P1

LED

D9

1

2

3

4

5

6

7

LMEP1

LMEP2

COM

INTRLK

STOP

CLOSE

OPEN

2

1

D14

TTC

3

4

5

OPEN

6

7

TO VERIFY TIMER TO CLOSE (TTC) SETTING
1. Press and release the LEARN button.
2. Press and release the TTC button.
3. Press and release the TTC button a second time.
4. The LED will flash once per 5 seconds of timer setting.

MEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

3-BUTTON REMOTE CONTROL TO OPERATE AS A
WIRELESS 3-BUTTON CONTROL STATION

Logic Board

Electrical Box

Timer To Close Button

NOTE: The feature will use 3 of the 20 memory channels in the
operator.
D7
U4 D6

014A1030

D7
U4 D6

014A1030
C20

D5
D4

J4
C32

C31

U1

1

^^^^
C18

2

3

4

5

R27
D14

TTC

LEARN STOP CLOSE OPEN
LED

D9

1

2

3

4

5

6

7

LMEP1

LMEP2

COM

INTRLK

STOP

CLOSE

OPEN

K2
LT
C29
R24
P1

LMEP1 LMEP2 COM INTRLK STOP CL

CLEAR THE TIMER TO CLOSE (TTC)
1. Press and release the LEARN button (LED will light.)
2. Press and hold the TTC button for 6 seconds.
3. Release the TTC button (LED will go out).
The TTC will no longer be active.
TIMER DEFEAT
The TTC can be temporarily disabled by pressing a STOP button.
TTC will become enabled after the next open command.

CLOSE OPEN

D14
LED
D5
D4

J4
C32
R25

C9

C31

TP1

CLO

R25
C21

L5

J2

Logic Board

STOP

C20

TP1
C9

AUX
AUX ANT
ANT

TO ERASE ALL REMOTE CONTROLS
Press and hold the LEARN button (over 5 seconds) until the
LED goes out. All programmed remote controls will be erased.

LEARN

STOP

D14
LED

TO PROGRAM
Open
1. Press and hold the LEARN button
Close
Stop
(LED will light).
2. Press the desired button on the logic
board (OPEN, CLOSE or STOP). Release both buttons.
3. Press and hold the desired button of the remote control until
LED flashes rapidly, then release.
4. Repeat steps 1 through 3 to program additional buttons.

Electrical Box

LEARN

TTC

U1

C21

L5
^^^^

AUX
AUX ANT
ANT

C18
R27

J2

D14

TTC

LEARN STOP CLOSE OPEN
LED

D9

1

2

3

4

5

6

7

LMEP1

LMEP2

COM

INTRLK

STOP

CLOSE

OPEN

K2
LT
C29
R24
P1

1

2

3

4

5

6

7

RADIO OPERATION
MODE

OPEN

CLOSE

STOP

B2
B2
with
TTC
C2

X

X
X
(3 button
remote)

X

X

X

X

X

X

MEP1 LMEP2 COM INTRLK STOP CLOSE OPEN

NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this
receiver and/or transmitter are prohibited, except for changing the code setting or replacing the
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.

4

X
X

REVERSE WHILE
CLOSING

TTC
RESET

X WHEN
OPEN

WARNING
MANUAL DISCONNECT (MODELS MT/B
MT & MH)
The operators have provisions for manually operating the door in
case of emergency or power failure. Refer to the appropriate
instructions for your model operator.

CAUTION
To prevent possible SERIOUS INJURY or DEATH from a falling
door or arm:
• DO NOT stand under the door arm when pulling the emergency
release.
• If possible, use emergency release handle to disengage trolley
ONLY when door is CLOSED. Weak or broken springs or
unbalanced door could result in an open door falling rapidly and/
or unexpectedly.
• NEVER use emergency release handle unless doorway is clear of
persons and obstructions.

MODEL MT/BMT

Emergency
Disconnect

AVERTISSEMENT

TO DISCONNECT DOOR FROM OPENER

Emergency
Disconnect

Door Arm
NOTI
C

E

Door

TO RECONNECT DOOR ARM TO TROLLEY

ATTENTION

Pull emergency
release handle
straight down.
Emergency
disconnect will
open.

Emergency
Disconnect

Door
Arm

Emergency
Release Handle

Lift free end of door
arm to trolley. Pull
emergency handle
to allow arm to
engage roll pin.
Release handle.
Emergency
disconnect will
close.

MODEL MH
Chain Retaining Bracket
(with pad locking provisions)

These operators are equipped with a manual hoist. An electrical
interlock will disable the electrical controls when the hoist is used. To
operate the hoist:

ADVERTENCIA

1. Pull the disconnect chain (sash chain) to engage the hoist
mechanism. The disconnect chain may be locked in position by
slipping the end through the keyhole of the chain retaining bracket
mounted on the wall.

PRECAUCIÓN

2. Operate the door in the desired direction by pulling on one side or
the other of the continuous loop hoist chain.
3. The disconnect chain must be released from the chain retaining
bracket before the door will operate again electrically.
Electrical Interlock with Hoist for Model MH

5

WARNING

MANUAL DISCONNECT (MODELS MJ/MGJ & MHS)
MODEL MJ/MGJ

CAUTION

This operator has a floor level disconnect chain to disconnect the
door from the door operator.
1. To disengage, pull the chain and secure in the disengaged position
by slipping the end through the keyhole bracket mounted on the
wall. Or if emergency egress device is used, pull handle to
disengage operator from door.
2. The door may now be pushed up or pulled down manually.
3. Release the disconnect chain or reset the emergency egress device
to operate the door again electrically.

To prevent possible SERIOUS INJURY from a moving chain,
DISCONNECT electric power to the operator BEFORE manually
operating your door.

MODEL MHS
This operator includes two methods of manual operation:
1. A disconnect sash chain for push-up/pull-down operation. This
chain can be found on the hoist side of the operator. See Manual
Disconnect - Model MJ/MGJ for instructions.
2. A hoist engagement sash chain for manual hoist operation. This
chain can be found on the clutch side of the operator. See Manual
Disconnect - Model MH for instructions.

AVERTISSEMENT

Keyhole Bracket

When operator is disconnected by the manual operation chain, hoist
and electrical operation will not function.

ATTENTION

Chain Retaining Bracket
(with pad locking provisions)

Hoist Chain

Manual Disconnect for Models MJ and MGJ

Electrical Interlock with Hoist Chain (when present) for Model MHS

ADVERTENCIA
PRECAUCIÓN

6

WARNING

TESTING

Turn on power, LED will flash 7 times on power up. Test all
controls and safety devices to make sure they are working
properly. If the operator does not function properly, contact your
installing dealer.

CAUTION

WARNING
WARNING

To avoid SERIOUS PERSONAL INJURY or DEATH from
electrocution, disconnect ALL electric power BEFORE performing
ANY maintenance.

IMPORTANT NOTES:
• Do not leave power to the operator on unless all safety and
entrapment protection devices have been tested and are working
properly.
• Be sure you have read and understand all safety instructions
included in this manual.
• Be sure the owner or person(s) responsible for operation of the
door have read and understand the safety instructions, know how
to electrically operate the door in a safe manner and how to
manually disconnect the door from the operator.

TEST THE SAFETY DEVICES (IF INSTALLED)
1. Open the door.
2. Place an obstruction in the path of the photo eyes or sensing
edge.
3. Press the CLOSE button.
The door should not close if photo eyes are installed. The door
should close to obstruction and reverse if sensing edge is
installed.
4. Remove the obstruction.
5. Press CLOSE button. Door should close.
If door did not reverse from obstruction, check safety devices.

AVERTISSEMENT

AVERTISSEMENT

TEST 3-BUTTON CONTROL STATION
1. Press OPEN button. (The door should move in the open
direction.)
2. Press STOP button. (The door should stop.)
3. Press CLOSE button. (The door should move in the close
direction.)
4. Release CLOSE button. Door should stop if in C2 mode. (The
door should continue closing if in B2 mode.)
5. Press STOP button. (The door should stop.)

ATTENTION

AVERTISSEMENT

TEST REMOTE CONTROL
* Requires B2 wiring type and compatible LiftMaster remote
control. In C2 wiring the remote control will open the
door only.
1. Press remote control button.
2. Door should open. Allow the door to fully open.
3. Press remote control button.
4. Door should close. Allow door to fully close.

TEST LIMIT ADJUSTMENT
1. Press OPEN button. (The door should open.)
2. Allow the door to fully open.
3. Press CLOSE button. (The door should close.)
4. Allow the door to fully close.
5. If the limits are not set properly, contact your installing dealer.

ADVERTENCIA

ADVERTENCIA
ADVERTENCIA

PRECAUCIÓN

7

TROUBLESHOOTING
To locate a dealer in your area visit us online at www.liftmaster.com

CONDITION

POSSIBLE CAUSE

FIX

OPERATOR WILL NOT
RESPOND TO ANY
COMMANDS

No power

➤ Check circuit breaker.

Accessory failure

➤ Verify photo eyes are aligned.

Possible component failure

➤ Contact your installing dealer.

OPERATOR MAKES
NOISE BUT DOOR DOES
NOT MOVE

Operator requires adjustment

➤ Contact your installing dealer.

DOOR DRIFTS AFTER
OPERATOR STOPS

Operator or door requires
adjustment

➤ Contact your installing dealer.

DOOR OPENS/CLOSES
TOO FAR

Operator requires adjustment

➤ Contact your installing dealer.

DOOR REVERSES
UNEXPECTEDLY

Safety device activated

➤ Verify photo eyes are aligned. If photo eyes are aligned and operator still does
not operate properly, contact your installing dealer.

Remote control is not
programmed

➤ See PROGRAMMING REMOTE CONTROLS section.

Low battery

➤ Replace battery.

REMOTE CANNOT BE
PROGRAMMED

Low battery

➤ Replace battery.

POOR RANGE

Low battery

➤ Replace battery.

Possible radio interference

➤ Contact your installing dealer.

RADIO FUNCTIONALITY
NO RESPONSE

MAINTENANCE SCHEDULE
Every 3 months or 5,000 cycles repeat all tests in the Testing
section.
Call qualified service contractor for maintenance. To locate a dealer
in your area visit us online at www.liftmaster.com.
The operator should be serviced at the following intervals:
• Every 3 months or 5,000 cycles
• Every 6 months or 10,000 cycles
• Every 12 months or 20,000 cycles

WARNING
To avoid SERIOUS PERSONAL INJURY or DEATH from
electrocution, disconnect ALL electric power BEFORE performing
ANY maintenance.

CAUTION

AVERTISSEMENT
8

ATTENTION

O P E R AT O R N O T E S

9

O P E R AT O R N O T E S

10

O P E R AT O R N O T E S

11

OPEN

ACCESSORIES

OPEN

ENTRAPMENT PROTECTION DEVICES

REMOTE CONTROLS 315MHz

1-Button SECURITY✚® Remote Control:
Includes visor clip.

371LM

Monitored
CPS-LN4

OPEN

PRESS
TO

R ING

Commercial Protector
System®:
Provides protection on doors up
to 45' wide. NEMA-4 rated.
OPEN

3-Button SECURITY✚® Remote Control:
Includes visor clip.

373LM

®
Commercial Protector System
PRESS:
TO
RING
Provides protection on doors up
to 30' wide.

CPS-L

333LM
OPEN

3-Button Tri-Colored Dip Switch
Remote Control:
Includes visor clip.

Wireless Single Push Button Control
SECURITY✚®:
Rugged composite housing. (Wireless
controls can not be used in place of
hardwired controls.)

TO

R ING

Non-Monitored
Vehicle Detection System
Pneumatic Sensing Edge Kit

ANTENNA

EXT-ANT

PRESS
TO

R ING

WPB3LM

WKP5LM

1

2

4

3

5

6

7

8

9

*

0

#

Wireless 3 Button Control Station
SECURITY✚®:
Rugged composite housing. (Wireless
controls can not be used in place of
hardwired controls.)

CLOSE

PRESS

65-8202

WPB1LM

OPEN

86LM (15')
86LMT (25')

Wireless Access Control Keypad
SECURITY✚®:
Rugged composite housing. (Wireless
controls can not be used in place of
hardwired controls.)

External Antenna:
The external antenna can be used to
increase the radio receiver range.

Antenna Extension Kit:
The antenna extension kit can be used with
EXT-ANT for maximum radio receiver
range.

CONTROL STATIONS

2-Button Control Station:
Steel enclosure.

02-102

WIRE

65-7WIREL

7 Conductor 20 AWG Wire (500'):
Recommended for control wiring.

21-2LM

2-Strand 22 AWG Wire (500'):
Color coded, white and white/black.

OPEN

CLOSE

3-Button Control Station:
Steel enclosure.

02-103

PRESS

^

OP
EN

OPEN

TO

R ING

OPEN

^

CLOS
E

CLOSE

O

STOP

CLOSE

Key Control Station:
Indoor flush mount, NEMA 1.

02-109
OPEN

CLOSE

50-104-1

Coil Cord 18 AWG Wire (20'):
Black coil cord, 2 wire, 18 AWG, 20'
extended.
OPEN

CLOSE

01-34215B

© 2008, The Chamberlain Group, Inc.
All Rights Reserved
PRESS

PRESS
TO

R ING



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
Page Mode                       : UseOutlines
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23
Modify Date                     : 2009:04:10 12:57:31-07:00
Create Date                     : 2008:08:04 07:42:55-07:00
Metadata Date                   : 2009:04:10 12:57:31-07:00
Format                          : application/pdf
Title                           : 01-34215
Creator                         : The Chamberlain Group, Inc.
Document ID                     : uuid:e7d18c79-043b-4b01-a01f-ff6348bdc5e7
Instance ID                     : uuid:534b1e9a-c0b5-c44f-a960-1b2622dff1b5
Page Count                      : 12
Author                          : The Chamberlain Group, Inc.
EXIF Metadata provided by EXIF.tools

Navigation menu