LP Series LED Steplight 
Page 1 of 2

LP

Normal AC and/or Emergency Low Level Applications

The LP Series is designed to support low-level illumination of stairwells, step landings, wheelchair ramps, exit corridors, theaters, restaurants and hospitals.

1.50”
(3.8 cm)

2.75”

(6.99 cm)

3.25”

4.50”

(8.25 cm)

(11.4 cm)

Complete Fixture consists of luminaire. Select options and accessories below.

How to Specify:
	 LP		

S	

WH	

SERIES	
	

INPUT	
LENS	
FINISH	
VOLTAGE			

LP = Low Level
Emergency Lighting
Product

1 = 12V AC, DC
2 = 120 AC

S = Satin

Features

	

	

WH = White
BK = Black
IV = Ivory

1.	Illumination: The LP Series LED engine utilizes three high performance,
3500k white LEDs combined with a solid-state integral driver circuit.
Incorporates a user selectable, three level intensity control.
2.	 Housing: Assembled from premium die cast aluminum components and
is painted in a durable powder coat finish. Standard finishes include black,
white and ivory. Assembled as a one-piece device that includes the LED light
engine, integral power supply, three level intensity control and a single gang
junction box mounting plate. All LED and electrical components are protected by both a frosted acrylic lens and high impact power supply case that
will be located within the junction box.
3.	 Electronics: Designed with all solid-state components and is rated for 10
years of continuous “normally on” use. Standard product incorporates dip
switches on rear of product allowing three levels of intensity.
4.	 Versatile Applications: “Normally On” remote power supplies are
available from 100VA to 500VA in 12 VAC. Power supplies (120 VAC input)
conform to UL 1598 and are rated as Class 2 Distribution systems. All power
supplies are furnished in a UL type 3R enclosure and are provided with thermal
type secondary output circuit protection. (Suggested for use with Lightolier’s
LPS Series)
		 “Normally Off/Emergency” remote power can be provided by any
Lightolier 12V emergency lighting product with additional remote capacity.
(Suggested for use with Lightolier catalog No. C3250 or C3275.)
		 “Normally On/Emergency” remote power can be provided by Lightolier
LM emergency power system. The LM system will support up to 14 LP Series
luminaires operating in both continuous duty and emergency operation for 90
minutes.
5.	 Electrical Specifications: 12 VDC input: 0.47 amps; 12 VAC input: 0.72
amps; 120 VAC input: 0.09 amps

6.	 Installation: LP is designed for installation in a single gang metallic or
die cast junction box. When installing the LP in an outdoor damp or wet
location, a single gang rectangular-style junction box will be required by
most local electrical codes.
7.	 Operating Temperature Range: -40°F (-40°C) to 122°F (50°C)
8.	 Warranty: Five-year full electronics warranty.

Code Compliance

UL 1598 listed. NFPA, BOCA and OSHA illumination standards. Meets
ADA specifications for wall mounted lighting fixtures. UL listed for wet
locations.

Job Information

Type:

Job Name:
Cat. No.:

Lamp(s):
Notes:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • E0109

Lightolier is a Philips group brand

LP Series LED Steplight 
Page 2 of 2

Normal AC and/or Emergency Low Level Applications

Multiple Luminaries	
18” AFF

		

Luminaire #1

1.0

3’

				

Single Luminaire
18” AFF

Luminaire #2

8’

1.0

3’

8’

.5
.2

.1

.5

.3
.2

.1

8’ x 3’ Path (Shown Above)

8’ x 4’ Path

Illuminance Values (Fc)
Average = 1.07
Maximum = 1.80
Minimum = 0.50
Avg/Min Ratio = 2.14
Max/Min Ratio = 3.60
See Note #1

Illuminance Values (Fc)
Average = 1.04
Maximum = 3.10
Minimum = 0.30
Avg/Min Ratio = 3.47
Max/Min Ratio = 10.33
See Note #1

.3

3’ x 6’ Area (Shown Above)
Calc. Rep Entrance Area
Illuminance Values (Fc)
Average = 1.38
Maximum = 4.70
Minimum = 0.30
Avg/Min Ratio = 4.60
Max/Min Ratio = 15.67
See Note #1

Note #1: Photometry based on clear lens. Please consult factory for frosted/white lens IES files.

LPS Series “Normally On / Non-Emergency Application” Non-Emergency Power Supply Selection
• 12 VAC applications
A
• 120 VAC Input Versions rated as Class II Distribution Systems
• UL 3R Enclosures
• Thermal secondary output circuit protection
• Convenient bottom access wiring compartment with terminal lugs
	
No. of LP Series	
Input	
Output	
Catalog		
Dimensions	
	
	
	
	
	
	
	
	

Luminaries Required	
10	
15	
25	
30	
30	
50	
50	

Voltage	
120	
120	
120	
120	
277	
120	
277	

Wattage	
100	
150	
250	
300	
300	
500	
500	

Number	
LPS100-12-1	
LPS150-12-1	
LPS250-12-1	
LPS300-12-1	
LPS300-12-2	
LPS500-12-1	
LPS500-12-2	

A	
4.88”	
4.88”	
4.88”	
4.88”	
4.88”	
5.63”	
5.63”	

B	
6.75”	
6.75”	
6.75”	
6.75”	
6.75”	
8.25”	
8.25”	

SERIES	
	 OLTAGE	
V
C3 = C3 Series Power
Module

2		

L	

DC	
OUTPUT	
WATTAGE		

BATTERY	
FINISH	

2 = 12 Volt

50 = 50 Watts
75 = 75 Watts

L = Sealed Lead
Calcium

C			
C
4.63”				
4.63”				
4.63”				
4.63”		
B
4.63”
5.25”
5.25”

5.63”

C3 Series “Normally Off / Emergency” Application
• 12 VDC Applications
• Maintenance-free, sealed lead calcium battery
• 50 watt can operate maximum 8 LP Luminaire
• 75 watt can operate maximum 13 LP luminaires

	 C3	

(14.3 cm)

5.75”

(14.6 cm)

9.5”

(24.1 cm)
TRIM COVER		
	
W = White
B = Black

See C3 spec sheet for full details

LM Series “Normally On / Emergency” Application
• NEMA 1 Enclosure
• Maintenance-free, sealed lead calcium battery
• Can operate 14 LP luminaires

3.5”

8.89 cm

14.4”

36.6 cm

		

24.0”

60.96 cm

		
	 Total Unit	
	 w/ Battery	

150 VA
50 lbs.
(22.7 kg)

See LM spec sheet for full details

LM	
Series	
LM = Mini - Interruptible	
Power Supplies	
		
		
		
		
		
		

LP

Input/Output Voltages	
1 = 120V/120V w/o Light Switch Option	
2 = 120V/120V w/ Light Switch Option	
3 = 277V/277V w/o Light Switch Option	
4 = 277V/277V w/ Light Switch Option
5 = 120V/12V w/o Light Switch Option
6 = 120V/12V w/ Light Switch Option
7 = 277V/12V w/o Light Switch Option
8 = 277V/12V w/ Light Switch Option

Lightolier is a Philips group brand

Mounting Configuration
CM = Ceiling Plenum Installation*
SM = Surface Wall Mount
RM = Recessed Wall Mount**
NOTES:
* (1) MICKIT and (1) MIRDIS accessories included
** Drywall Opening Dimensions: 14.5” W x 24.0” L

Job Information

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • E0109



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.1-c037 46.282696, Mon Apr 02 2007 18:36:56
Create Date                     : 2009:01:06 08:40:03-05:00
Modify Date                     : 2009:01:06 08:40:12-05:00
Metadata Date                   : 2009:01:06 08:40:12-05:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 10187 bytes, use -b option to extract)
Version ID                      : 1
Instance ID                     : uuid:24d50095-7bc0-43c4-a95e-91074cb2977f
Document ID                     : adobe:docid:indd:a50d0d3a-0688-11dd-b656-a9a536293559
Rendition Class                 : proof:pdf
Derived From Instance ID        : a50d0d39-0688-11dd-b656-a9a536293559
Derived From Document ID        : adobe:docid:indd:a50d0d37-0688-11dd-b656-a9a536293559
Derived From Version ID         : 1
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 300.00, 300.00, 72.00, 72.00, 240.00, 240.00, 72.00
Manifest Placed Y Resolution    : 300.00, 300.00, 72.00, 72.00, 240.00, 240.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:98193c42-614d-11d9-9e16-b8877bc42726, uuid:98193c46-614d-11d9-9e16-b8877bc42726, uuid:564cc7d9-5f06-11d9-8e13-d31bf9acbbe9, uuid:564cc7d5-5f06-11d9-8e13-d31bf9acbbe9, uuid:e461a6ee-5f07-11d9-8e13-d31bf9acbbe9, uuid:e461a6ee-5f07-11d9-8e13-d31bf9acbbe9, uuid:31a06bef-45cd-11d9-8c6c-da726554b79b
Manifest Reference Document ID  : adobe:docid:photoshop:d49d201e-6143-11d9-9e16-b8877bc42726, adobe:docid:photoshop:98193c43-614d-11d9-9e16-b8877bc42726, adobe:docid:photoshop:564cc7d6-5f06-11d9-8e13-d31bf9acbbe9, adobe:docid:photoshop:564cc7d2-5f06-11d9-8e13-d31bf9acbbe9, adobe:docid:photoshop:25a60cef-5f07-11d9-8e13-d31bf9acbbe9, adobe:docid:photoshop:25a60cef-5f07-11d9-8e13-d31bf9acbbe9, adobe:docid:photoshop:31a06bec-45cd-11d9-8c6c-da726554b79b
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS3 (5.0.4)
EXIF Metadata provided by EXIF.tools

Navigation menu