LigoWave PTP5NMP 2x2 MIMO 802.11 DIGITAL TRANSMISSION SYSTEM User Manual Title

LigoWave LLC 2x2 MIMO 802.11 DIGITAL TRANSMISSION SYSTEM Title

Users Manual

                   LigoPTP 5-N MIMO PRO  Quick Installation Guide           Revision 1.0  March 5, 2012                          Copyright © 2012 LigoWave www.ligowave.com
Copyright  © 2012 LigoWave  This user’s guide and the software described in it are copyrighted with all rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written permission of LigoWave.       Notice  LigoWave reserves the right to change specifications without prior notice.  While the information in this manual has been compiled with great care, it may not be deemed an assurance of product characteristics. LigoWave shall be liable only to the degree specified in the terms of sale and delivery.  The reproduction and distribution of the documentation and software supplied with this product and the use of its contents is subject to written authorization from LigoWave.   Trademarks  LigoWave logo is trademark of LigoWave LLC.  All other registered and unregistered trademarks in this document are the sole property of their respective owners.                                        LigoWave  Page 1
FCC Warning  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:     Reorient or relocate the receiving antenna.    Increase the separation between the equipment and receiver.    Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.    Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  FCC Caution  To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.  FCC Radiation Exposure Statement  To comply with FCC RF exposure requirements in section 1.1307, a minimum separation distance of 4.5 feet is required between the antenna and all occupational persons, and a minimum separation distance of 10.2 feet is required between the antenna and all public persons.  Antenna Installation  WARNING: It is installer’s responsibility to ensure that when using the authorized antennas in the United States (or where FCC rules apply), only those antennas certified with the product are used.  The use of any antenna other than those certified with the product is expressly forbidden in accordance to FCC rules CFR47 part 15.204. The installer should configure the output power level of antennas, according to country regulations and per antenna type.  Professional installation is required of equipment with connectors to ensure compliance with health and safety issues.  Industry Canada Statement  English  Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.  This radio transmitter (7607A-PTP5NMP) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.  French  Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.  Le présent émetteur radio (7607A-PTP5NMP) a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste,ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.    LigoWave  Page 2
Antenna Compliance  The LigoPTP 5-N MIMO PRO radio has been tested and certified with the following antennas: Dish (32.5dBi) – Laird HDDA5W-32-DP Any antenna of same make and lower gain than those listed above may be used in compliance with certification.  CE Mark Warning  This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.    R&TTE Compliance Statement  This equipment complies with all the requirements of the Directive 1999/5/EC of the European Parliament and the Council of 9 March 1999 on Radio Equipment and Telecommunication Terminal Equipment and the Mutual Recognition of their Conformity (R&TTE).  The R&TTE Directive repeals and replaces in the directive 98/13/EEC (Telecommunications Terminal Equipment and Satellite Earth Station Equipment) As of April 8, 2000.    Safety  This equipment is designed with the utmost care for the safety of those who install and use it. However, special attention must be paid to the dangers of electric shock and static electricity when working with electrical equipment. All guidelines of this manual and of the computer manufacturer must therefore be allowed at all times to ensure the safe use of the equipment.    EU Countries Intended for Use  The ETSI version of this device is intended for home and office use in Austria, Belgium, Denmark, Finland, France (with Frequency channel restrictions), Germany, Greece, Ireland, Italy, Luxembourg, The Netherlands, Portugal, Spain, Sweden and United Kingdom.  The ETSI version of this device is also authorized for use in EFTA member states Iceland, Liechtenstein, Norway and Switzerland.    EU Countries Not Intended for Use  None.                        LigoWave  Page 3
      About This Guide    Purpose  The purpose of this guide is to provide a quick and easy explanation of getting started with the LigoPTP 5-N MIMO PRO. This is only a starter guide and full documentation may be found at our online wiki:  http://www.ligowave.com/wiki      Definitions, Acronyms and Abbreviations  The following typographic conventions and symbols are used throughout this document: Additional information that may be helpful but which is not required. Important information that should be observed.      LigoWave Technical Support  If you encounter problems when installing or using this product, please consult the LigoWave website at www.ligowave.com for:     Direct contact to the LigoWave support centers.    Frequently Asked Questions (FAQ).    Download area for the latest software, user documentation and product updates.    Contact Us  EU office:  UAB WILIBOX Veiveriu 150 - IIIa. Kaunas, LT-46391 Lithuania   Phone +370 37 759007  Fax +370 37 759006 (UTC +2) US office:  LigoWave  138 Mountain Brook Drive  Canton, GA 30115  United States of America   Phone +1 877 544 6928 (1 877 LIGOWAVE) +1 678 490 0108 (UTC -5)        LigoWave  Page 4
   Hardware Introduction   General Overview    The label of the LigoPTP 5-N MIMO PRO contains:     Model name. The official model name is LigoPTP 5-N MIMO PRO    FCC ID. The FCC ID is V2V-PTP5NMP    IC ID. 7607A-PTP5NMP                                      LigoWave  Page 5
    Access the LigoPTP 5-N MIMO PRO     The first connection to the LigoPTP 5-N MIMO PRO can be made using a standard Ethernet cable connected directly to your PC. See next sections for the instructions on how to access the LigoPTP 5-N MIMO PRO management interfaces.    Connection via WEB browser  The default IP address of the LigoPTP 5-N MIMO PRO is 192.168.2.66 with a subnet mask of 255.255.255.0.   Step 1  Configure your PC with a static IP address on the 192.168.2.0 subnet with mask 255.255.255.0. Connect LigoPTP 5-N MIMO PRO Ethernet interface in to the same physical network as your PC. Open the Web browser and type the default IP address of the LigoPTP 5-N MIMO PRO: https://192.168.2.66/      Step 2   Enter the LigoPTP 5-N MIMO PRO administrator login details to access the Web management:  The default administrator login settings for all LigoPTP 5-N MIMO PRO are:  User Name: admin Password: admin01  Step 3  After successful administrator log on you will see the main page of the LigoPTP 5-N MIMO PRO Web management interface. The LigoPTP 5-N MIMO PRO now is ready for configuration. For further instructions on Web management refer to the respective document at the LigoWave wiki at http://www.ligowave.com/wiki                  LigoWave  Page 6
  Resetting to Factory Defaults    LigoWave products have the capability of being reset to defaults by pinging the device with a certain packet size when the radio is booting.  During the startup of the device, when the drivers of the ethernet interfaces are loaded, the discovery daemon is started. The daemon suspends startup process for 3 seconds and waits for ICMP "echo request" packet of length 369 bytes. If the packet is received, the discovery daemonresets the device to default configuration.  Steps to reset to default settings:  Step 1. Power off the device.  Step 2. Obtain the device MAC address.  Step 3. Connect a PC to the same physical subnet as the device.  Step 4. Execute 'arp -s' command to assign the IP address (IP address should be from the same subnet as PC) to the device MAC address:  arp -s <IP address to assign> <device MAC address>  Step 5. Start pinging the device:  For linux users: ping <IP address> -s 369  For Windows users:  ping <IP address> -l 369 -t -w 200 -S <Computer IP address>  Step 6. Power up device and wait about 30sec or more (depends from device hardware).                                         LigoWave  Page 7

Navigation menu