P R O D U C T D ATA S H E E T HB80 HANDSET Features: • Handset for up to 5 actuators • Coiled or straight cable • Colour: Dark grey (RAL 7016), grey (RAL 7035) or black (RAL 9005) (only plastic housing, check available cables and front covers) • Protection class: IP54 • Up to 12 easy-touch buttons for OPENBUS™ and Matrix (CB20 and CB14) Options: • Customised front cover • Memory options • Simultaneous drive of actuators • Background lighting blue or green (for use with the Openbus™ system) • IP66 Washable Usage: • Approved according to: EN 60601-1 as part of a LINAK actuator system The HB80 is a new handset with an optimised ergonomic design and switch activation. The HB80 handset is designed in 2 versions. One has up to 10 big activation bottons. This can be used for almost all kinds of MEDLINE and CARELINE applications. For advanced MEDLINE applications such as special hospital beds a 6 row version is available with 12 activation bottons. The HB80 has an option of blue or green background lighting for use with the LINAK CB20 control box (Openbus applications). The HB80 is available in several different standard versions with a variation of bed symbols for easy interaction with end-users. Dimensions (mm): HB81 - HB85 Dimensions (mm): HB86 Precautions: • The HB86 version has a shorter distance between the buttons and cannot be approved according to EN 1970. HB80 Ordering example: HB8 1 5 6 00 0 01 + 01 Cable ID Cable length ID Total 01 850 mm 03 850 mm 11 750 mm 13 750 mm 21 2400 mm 23 2400 mm 31 2400 mm 33 2400 mm 45 850 mm 61 850 mm 63 850 mm Box colour + = Coiled 600 mm 600 mm 500 mm 500 mm 0 mm 0 mm 0 mm 0 mm 600 mm 600 mm 600 mm Color Grey Black Grey Black Grey Black Grey Black Dark Grey Grey Black Plug DIN 8P DIN 8P DIN 8P (7 wires max. HB83) DIN 8P (7 wires max. HB83) DIN 8P (7 wires max. HB83) DIN 8P (7 wires max. HB83) DIN 8P DIN 8P MJ RJ45 10P (not for OPENBUS) MJ RJ45 10P (6 wires) MJ RJ45 10P (6 wires) = Grey - RAL7035 (not for CB6) = Black (not for CB6) = Dark grey - RAL7016 (Only for CB6) Front cover See later pages Background light 0 = no 1 = green (ONLY Openbus™) 2 = blue (ONLY Openbus™) Functionality 0x (HB40 like) for: CB6, (CB6 with 3 ch. = ch.1, 3 and 4) CB7, CB8, CB18 (max. 3 channels) TDC, CBJH, sometimes CB9..AX and CB12 - see also Hx Ex (Matrix) for: CB9..Px (not CB9..PM/..PN) and CB14 EF (Matrix) for: CB140 Hx (HB40 like, common gnd) for: CB9..Ax and CB12 with simultaneous drive EW (Memory / Matrix) for: CB9..Px (not CB9..PM/..PN) and CB14 Vx (OPENBUS™ functionality) Housing 5 6 5 ROW based - big bottons only 1 - 5 ROWs 6 ROW based - small bottons IP rating 4 9 IP54 IP66 washable Number of rows (exclusive rows for memory) 1 - 5 rows - Big bottoms 6 rows - Small bottoms HB-type Precautions Cables: ID4x used for CB6 ID6x used for OPENBUS™ and CBJH Functionality overview for HB8x : 0x (HB40 like) for: CB6 (CB6 with 3 ch. = ch.1,3 and 4), CB7, CB8, CB18 (max. 3 channels), TDC, CBJH, sometimes CB9..AX and CB12 - see also Hx Ex (Matrix) for: CB9..Px (not CB9..PM/..PN) and CB14 EF (Matrix) for: CB140 Hx (HB40 like, common gnd) for: CB9..Ax and CB12 with simultaneous drive EW (Memory / Matrix) for: CB9..Px (not CB9..PM/..PN) and CB14 Vx (OPENBUS™ functionality) Functionality explanation: The digits above along with the functionality drawings are to be used as part of the product item number. • In the ordering example, there is a space reserved for 2 “functionality” digits. • I.e. if you need an HB82 you can e.g. choose between “00” and “E0” functionalities. • “00” functionality is compatible with CB6, CB7, CB8,…… ; • “Hx” functionality is compatible with CB9..AX and CB12 with sim. drive. Functionalities: Simultaneous/Trend HB82xx02/H2 HB83xx02/H2 HB84xx02/H2 HB85xx02/H2 HB85xx07/H7 3+4U 3+4D 1U 1D 1U 1D 1U 1D 1U 1D 3D4U 3U4D 3+4U 3+4D 2U 2D 2U 2D 3+4U 3+4D 3D4U 3U4D 3+4U 3+4D 1+2U 1+2D 2U 2D 3D4U 3U4D 3+4U 3+4D 1+2U 1+2D 3D4U 3U4D 3D4U 3U4D Functionalities: HB81xx00/E0 1U 1D HB82xx01/E1 HB82xx00/E0 HB83xx00/E0 HB84xx00/E0 2U 2D 2U 2D 2U 2D 1U 1D 1U 1D 1U 1D 3U 3D 3U 3D 3U 3D 4U 4D 4U 4D 5U 5D HB83xx01/E1 4U HB85xxE0/EF HB81xx0C/EC HB82xx0C/EC 1U 1U 1D 2U 2D 2U 2D 1U 1D 3U 3D 1 2 3 S 1D HB85xxEW 4D HB86xxEW 2U 2D 1U 1D 3U 3D 4U 4D 1 2 3 S Jumbo functionalities HB82xx 06 1U 1D HB83xx 09 1U CBJ2/CBJH 1U 1D 2U CBJH HB83xx 0A 1U slow 1D 2D 2U CBJ2 HB83xx 0B 2D 1U fast (1U) (2U) 1D slow (1D) 1D fast (2D) 2U 2D (3U) (3D) CBJ1 Functionalities: Simultaneous HB82xx03/H3 HB83xx03/H3 HB84xx03/H3 HB84xx04/H4 HB85xx04/H4 1U 1D 1U 1D 1U 1D 2U 2D 2U 2D 3+4U 3+4D 2U 2D 3U 3D 1U 1D 1U 1D 3+4U 3+4D 4U 4D 3U 3D 3U 3D 3+4U 3+4D 2+3U 2+3D 2+3U 2+3D 4U 4D HB82xx05/H5 HB83xx05/H5 HB84xx05/H5 3U 3D 3U 3D 3U 3D 1+2U 1+2D 1+2U 1+2D 1+2U 1+2D 4U 4D 4U 4D 3+4U 3+4D HB84xx07/H7 1+2U 1+2D HB84xx06/H6 3+4U 3+4D HB84xx0A/HA HB85xx0A/HA HB85xx0B/HB 1U 1D 1U 1D 1U 1D 3U 3D 3U 3D 3U 3D 2U 2D 2U 2D 2U 2D 1+2U 1+2D 1+2U 1+2D 1+2U 1+2D 4U 4D 4D HB83xx07/H7 Functionalities: HB81xxV0 HB81xxV1 HB81xxV2 HB82xxV0 HB82xxV2 HB83xxV0 HB83xxV1 HB83xxV2 HB84xxV0 HB85xxV0 HB85xxV1 HB85xxV2 HB84xxV1 HB86xxV0 HB84xxV2 HB86xxV1 H2 H3 H12 H13 H22 H23 H0 H1 H10 H11 H20 H21 H4 H5 H14 H15 H24 H25 H6 H7 H16 H17 H26 H27 H8 H9 H18 H19 H28 H29 HB86xxV2 H2 H3 H12 H13 H22 H23 H0 H1 H10 H11 H20 H21 H4 H5 H14 H15 H24 H25 H6 H7 H16 H17 H26 H27 H8 H9 H18 H19 H28 H29 H28 H29 H30 H31 H30 H31 For more functionalities contact LINAK. HB82xxV1 Various HB standard front covers 00HB841A-001 00HB851A-002 00HB841A-002 00HB861B-001 00HB861B-002 00HB831A-002 00HB841A-003 00HB851A-005 00HB821A-002 00HB811A-001 00HB821A-002 Various HB standard front covers 00HB851D-001 00HB831A-001 00HB821A-001 00HB811A-004 HB80 Standard front covers - when ordering check that the handset functionality corresponds to the symbols on the front cover. The last 2 digits in the front cover code are to be used in the ordering example (xx). Copyright© LINAK 2008.02 . MA M9-02-226-B . Chapter 9.18 For all types attention should be given to ensure that the channels shown correspond to the channels on the chosen control box. Specifications subject to change without prior notice. It is the responsibility of the product user to determine the suitability of LINAK A/S products for a specific application. LINAK will at point of delivery replace/repair defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/repair.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Title : untitled Create Date : 2008:02:12 13:37:01+01:00 Modify Date : 2008:02:12 13:37:21+01:00 Metadata Date : 2008:02:12 13:37:21+01:00 Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:f0e59065-8179-4d7e-a240-97cf3ab86b7d Instance ID : uuid:c4c158fb-2e98-4130-94cc-d1064725d79e Page Count : 8EXIF Metadata provided by EXIF.tools