P R O D U C T D ATA S H E E T
HB70
HANDSET
Features:
• Easily operated by both left and right handers
• Ergonomic and elegant design
• Tactile switches secure long lifetime
• Up to 10 easy-touch buttons
• Protection class IP66
• 600 mm coiled cable
• Colour black (RAL 9005)
Options:
• Customised front cover
• Memory options
• Simultaneous drive of more
re actuators
• Colour grey (RAL7035) / dark
ark grey (RAL 7016
- only CB6/LA27 system)
• Protection class IP66 washable
ble
• Protection class IP51 (CS27)
Usage:
• Compatible with most LINAK control
ontrol boxes
• Approved according to: EN 60601-1,
1-1, EN 60335-1
and UL 60601-1 as part of a LINAK
AK actuator
system
HB70 combines ergonomic design and functionality.
LINAK offers HB70 with protection class IP 66 as
standard and a range of options such as control
of up to 5 actuators, memory and simultaneous
drive. HB70 is designed to operate with most
LINAK control boxes.
Dimensions (mm):
Precautions:
• It is not possible to combine the HB7x with the binary based CB9..PM/PN.
• The IP66 Washable version has a special adhesive for the front covers.
• The HB75xEx used together with the CB140 will give trend and anti-trend on channel 1 and 2 of the control
box when using the last button row.
• All front covers use the codes W0 (not Washable) and WW (Washable)
Memory:
• The memory and parallel functions require the control box to have a microprocessor.
• When storing the memory position on the CB20, CB14, CB18MKII and newer versions the actuators must be
run to the desired position and the “store” button (S) must be pushed.
Then the desired memory position button (1, 2 or 3) must be activated within 2 seconds.
HB70
Ordering example:
HB7 1 6 00 0 1
+ 4 2420
Cable length
Standard lengths
Plug +
Cable-type
Coiled
D
Coiled
I
Straight
N
Straight
p
Coiled/
l
Straight
u
Coiled/
g
Straight
Coiled
MP
MP Coiled
MF Straight
UF Straight
7-core
5-wire
3/5 or 5/7 core
8-core
9-core
Grey Black Grey Black Grey Black Grey
Dark grey
0600 0600
0500 0500
2420 2420
2420 2420
0600/ 0600/
1700 1700
0600/ 0600/
500 500
0600
0600
0600
2000
2475
MP = Modular Plug (8 pins) for CB7/CBD
MP = Modular Plug (10 pins) for CB6
MF = Mini-Fit for CB27 (functionality 00)
UF = Micro-Fit for CS18 (functionality 0X, Hx)
Cable type
0 Straight Mini Fit for CB27 (3/5 cores or 5/7 cores)
1 Coiled 9-core. DIN
2 Coiled 7-core. DIN (max. Ch.3)
3 Coiled 8-core. Modular Plug (CB7/CBD/CBR)
4 Straight 7-core. DIN. (max. Ch. 3)
5 Straight 9-core. DIN
6 Coiled 9-core Modular Plug (CB6, TDC)
8 Coiled 9-core. Extra long straight end 1,7 m DIN
9 Coiled 9-core. Extra long straight end. 0,5 m DIN
A Straight 12-pin micro-fit for CS18. 9 + 2 cores
B Coiled 5 wire Modular Plug (e.g. CB20, CBJH)
Black
Grey (dark-light)
0277015- or 02770160015621
0015623
0015622
0015624
0567005
0015651
0015650
0015653
0015652
0015628
0015627
0015626
0015625
0277010-600
00914450
0964004
Box Colour
+ = Grey - RAL 7035 (not for CB6)
- = Black (not for CB6)
= = Dark grey - RAL 7016 (Only for CB6 and CS27)
Front cover = XX (see page "HB70 Standard front covers")
Functionality = XX (see next page)
IP Degree
1
IP51 (if cable type 0 (Only CS27))
6
IP66
9
IP66 washable ("WW" means washable, as part of the front cover code)
Number of ROWS (exclusive rows for memory)
Max. 5 rows
Max. 3 rows for memory types (not including memory rows)
HB-Type
For customised front covers, please contact the sales department at LINAK A/S.
Functionality overview for the HB7X :
0x (HB40 like) for: CB6 (CB6 with 3 ch. = ch.1,3 and 4), CB7, CB8, CB18 (max. 3
channels),TDC, CBJH, sometimes CB9..AX and CB12 - see also Hx
Ex (Matrix) for: CB9..Px (not CB9..PM/..PN) and CB14
EF (Matrix) for: CB140
Hx (HB40 like, common gnd) for simultaneous drive on both CB9 and CB12
EW (Memory / Matrix) for: CB9..Px (not CB9..PM/..PN) and CB14
LO (Binary) for: CB18MKII and newer versions
Vx (OPENBUS™ functionality)
Functionality explanation:
The digits above the functionality drawings are to be used as part of the product item number.
• On page 3, in the ordering example, there is a space reserved for 2 “functionality”
digits (between the IP degree and the last 2 digits of the front cover number).
• I.e. if you need a HB72 you can e.g. choose between “02” and “H2” functionalities.
• “02” functionality is compatible with CB6, CB7, CB8,…… ;
• “H2” functionality for simultaneous drive on both CB9 and CB12
HB71..
0C/EC
00/E0
1U
1U
VO
V1
V2
1D
1D
H0
H1
H10
H11
H20
H21
HB72..
0C/EC
00/E0
02/H2
01/E1
03/H3
2U
2D
1U
1D
3U
3D
3+4U
3+4D
1U
1D
1U
1D
2U
2D
4U
4D
3D4U
3U4D
3+4U
3+4D
HB72..
V0
05/H5
V1
V2
3U
3D
H2
H3
H12
H13
H22
H23
1+2U
1+2D
H0
H1
H10
H11
H20
H21
HB73..
00/E0
01/E1
2U
2D
1U
1D
1U
1D
3U
3D
3U
3D
4U
4D
03/H3
02/H2
1U
1D
1U
1D
3+4U
3+4D
2U
2D
3D4U
3U4D
3+4U
3+4D
For all types attention should be given to ensure that the channels shown correspond to the channels on the
chosen control box.
HB73..
08/H8
07/H7
05/H5
V0
3U
3D
1U
1D
3U
3D
H2
H3
1+2U
1+2D
3+4U
3+4D
1+2U
1+2D
H0
H1
4U
4D
2U
2D
1D2U
1U2D
H4
H5
HB74..
HB73..
V2
V1
0A/HA
00/E0
H13
H22
H23
2U
2D
1U
1D
H10
H11
H20
H21
1U
1D
3U
3D
H14
H15
H24
H25
3U
3D
2U
2D
4U
4D
1+2U
1+2D
H12
HB74..
07/H7
06/H6
03/H3
05/H5
3U
3D
1U
1D
1U
1D
3U
3D
1U
1D
3+4U
3+4D
3U
3D
1+2U
1+2D
4U
4D
2U
2D
4U
4D
4U
4D
3+4U
3+4D
1+2U
1+2D
3+4U
3+4D
3+4U
3+4D
HB74..
04/H4
V0
08/H8
02/H2
2U
2D
1U
1D
3U
3D
H2
H3
1U
1D
2U
2D
4U
4D
H0
H1
3U
3D
3+4U
3+4D
1+2U
1+2D
H4
H5
2+3U
2+3D
3D4U
3U4D
1D2U
1U2D
H6
H7
HB75..
HB74..
V1
V2
H12
0B/HB
0A/HA
H22
H23
1U
1D
1U
1D
3U
H10
H11
H20
H21
3U
3D
3U
3D
H14
H15
H24
H25
2U
2D
2U
2D
H26
H27
1+2U
1+2D
1+2U
1+2D
4U
4D
H17
H16
3U
4D
HB75..
02/H2
08/H8
07/H7
04/H4
1U
1D
2U
2D
1U
1D
3U
3D
2U
2D
1U
1D
3+4U
3+4D
4U
4D
1+2U
1+2D
3U
3D
2U
2D
3+4U
3+4D
3+4U
3+4D
2+3U
2+3D
1+2U
1+2D
1+2U
1+2D
3D4U
3U4D
4U
4D
3D4U
3U4D
1D2U
1U2D
HB75..
E0/EF
09/H9
V1
V0
3U
3D
2U
2D
H2
H3
H12
H13
1+2U
1+2D
1U
1D
H0
H1
H10
H11
4U
4D
3U
3D
H4
H5
H14
H15
3+4U
3+4D
4U
4D
H6
H7
H16
H17
1D2U
1U2D
5U
5D
H8
H9
H18
H19
HB72..
HB73..
HB75..
HB71..
EW/L0
EW/L0
V2
EW/L0
H22
H23
2U
2D
2U
2D
H20
H21
1U
1D
1U
1D
1U
1D
H24
H25
3U
3D
H26
H27
1
2
1
2
1
2
H28
H29
3
S
3
S
3
S
HB70 Standard front covers - when ordering check that the handset functionality corresponds to the symbols
on the front cover.
The last 2 digits in the front cover code are to be used in the ordering example (xx).
HBW071-00 HBW071-01
HBW072-01
HBW073-00
HBW072-03
HBW073-01
HBWW71-15
HBW071-19
HBW072-04
HBW072-33
HBW073-05
HBW073-06
HBW071W-01 HBW072-00
HBWW72-37
HBW072W-02
HBW073-34
HBW073-56
HBW074-00
HBW074-53
HBWW74-79
HBW075-00
HBWW75-48
HBW071-28
HBW072-47
Specifications subject to change without prior notice. It is the
responsibility of the product user to determine the suitability of
LINAK A/S products for a specific application. LINAK will at point
of delivery replace/repair defective products covered by the warranty if promptly returned to the factory. No liability is assumed
beyond such replacement/repair.
HBW074-01
HBW074-26
HBWW74-42
HBW075-01
HBW075-21
HBW075-25
Copyright© LINAK 2008.02 . MA M9-02-107-S . Chapter 9.4
HBWW73-61 HBW073W-01
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Title : HB70_ver_s_eng.indd Creator : CAS Create Date : 2008:02:05 09:10+01:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2008:02:05 09:10:23+01:00 Metadata Date : 2008:02:05 09:10:23+01:00 Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:614800a6-bea8-405e-8bf7-7aa77364d69f Instance ID : uuid:53788f3a-2904-4df3-a457-2b8c02209a9c Page Count : 8 Author : CASEXIF Metadata provided by EXIF.tools