P R O D U C T D ATA S H E E T

HB70
HANDSET
Features:
• Easily operated by both left and right handers
• Ergonomic and elegant design
• Tactile switches secure long lifetime
• Up to 10 easy-touch buttons
• Protection class IP66
• 600 mm coiled cable
• Colour black (RAL 9005)
Options:
• Customised front cover
• Memory options
• Simultaneous drive of more
re actuators
• Colour grey (RAL7035) / dark
ark grey (RAL 7016
- only CB6/LA27 system)
• Protection class IP66 washable
ble
• Protection class IP51 (CS27)
Usage:
• Compatible with most LINAK control
ontrol boxes
• Approved according to: EN 60601-1,
1-1, EN 60335-1
and UL 60601-1 as part of a LINAK
AK actuator
system

HB70 combines ergonomic design and functionality.
LINAK offers HB70 with protection class IP 66 as
standard and a range of options such as control
of up to 5 actuators, memory and simultaneous
drive. HB70 is designed to operate with most
LINAK control boxes.

Dimensions (mm):

Precautions:
• It is not possible to combine the HB7x with the binary based CB9..PM/PN.
• The IP66 Washable version has a special adhesive for the front covers.
• The HB75xEx used together with the CB140 will give trend and anti-trend on channel 1 and 2 of the control
box when using the last button row.
• All front covers use the codes W0 (not Washable) and WW (Washable)
Memory:
• The memory and parallel functions require the control box to have a microprocessor.
• When storing the memory position on the CB20, CB14, CB18MKII and newer versions the actuators must be
run to the desired position and the “store” button (S) must be pushed.
Then the desired memory position button (1, 2 or 3) must be activated within 2 seconds.

HB70
Ordering example:
HB7 1 6 00 0 1

+ 4 2420
Cable length
Standard lengths
Plug +
Cable-type
Coiled
D
Coiled
I
Straight
N
Straight
p
Coiled/
l
Straight
u
Coiled/
g
Straight
Coiled
MP
MP Coiled
MF Straight
UF Straight

7-core
5-wire
3/5 or 5/7 core
8-core
9-core
Grey Black Grey Black Grey Black Grey
Dark grey
0600 0600
0500 0500
2420 2420
2420 2420
0600/ 0600/
1700 1700
0600/ 0600/
500 500
0600
0600
0600
2000
2475

MP = Modular Plug (8 pins) for CB7/CBD
MP = Modular Plug (10 pins) for CB6
MF = Mini-Fit for CB27 (functionality 00)
UF = Micro-Fit for CS18 (functionality 0X, Hx)

Cable type
0 Straight Mini Fit for CB27 (3/5 cores or 5/7 cores)
1 Coiled 9-core. DIN
2 Coiled 7-core. DIN (max. Ch.3)
3 Coiled 8-core. Modular Plug (CB7/CBD/CBR)
4 Straight 7-core. DIN. (max. Ch. 3)
5 Straight 9-core. DIN
6 Coiled 9-core Modular Plug (CB6, TDC)
8 Coiled 9-core. Extra long straight end 1,7 m DIN
9 Coiled 9-core. Extra long straight end. 0,5 m DIN
A Straight 12-pin micro-fit for CS18. 9 + 2 cores
B Coiled 5 wire Modular Plug (e.g. CB20, CBJH)

Black

Grey (dark-light)

0277015- or 02770160015621
0015623

0015622
0015624

0567005
0015651

0015650

0015653

0015652

0015628

0015627

0015626

0015625

0277010-600

00914450
0964004

Box Colour
+ = Grey - RAL 7035 (not for CB6)
- = Black (not for CB6)
= = Dark grey - RAL 7016 (Only for CB6 and CS27)
Front cover = XX (see page "HB70 Standard front covers")
Functionality = XX (see next page)
IP Degree
1
IP51 (if cable type 0 (Only CS27))
6
IP66
9
IP66 washable ("WW" means washable, as part of the front cover code)
Number of ROWS (exclusive rows for memory)
Max. 5 rows
Max. 3 rows for memory types (not including memory rows)
HB-Type

For customised front covers, please contact the sales department at LINAK A/S.

Functionality overview for the HB7X :
0x (HB40 like) for: CB6 (CB6 with 3 ch. = ch.1,3 and 4), CB7, CB8, CB18 (max. 3
channels),TDC, CBJH, sometimes CB9..AX and CB12 - see also Hx
Ex (Matrix) for: CB9..Px (not CB9..PM/..PN) and CB14
EF (Matrix) for: CB140
Hx (HB40 like, common gnd) for simultaneous drive on both CB9 and CB12
EW (Memory / Matrix) for: CB9..Px (not CB9..PM/..PN) and CB14
LO (Binary) for: CB18MKII and newer versions
Vx (OPENBUS™ functionality)
Functionality explanation:
The digits above the functionality drawings are to be used as part of the product item number.
• On page 3, in the ordering example, there is a space reserved for 2 “functionality”
digits (between the IP degree and the last 2 digits of the front cover number).
• I.e. if you need a HB72 you can e.g. choose between “02” and “H2” functionalities.
• “02” functionality is compatible with CB6, CB7, CB8,…… ;
• “H2” functionality for simultaneous drive on both CB9 and CB12

HB71..
0C/EC

00/E0

1U
1U

VO

V1

V2

1D

1D

H0

H1

H10

H11

H20

H21

HB72..
0C/EC

00/E0

02/H2

01/E1

03/H3

2U

2D

1U

1D

3U

3D

3+4U

3+4D

1U

1D

1U

1D

2U

2D

4U

4D

3D4U

3U4D

3+4U

3+4D

HB72..
V0

05/H5

V1

V2

3U

3D

H2

H3

H12

H13

H22

H23

1+2U

1+2D

H0

H1

H10

H11

H20

H21

HB73..

00/E0

01/E1

2U

2D

1U

1D

1U

1D

3U

3D

3U

3D

4U

4D

03/H3

02/H2

1U

1D

1U

1D

3+4U

3+4D

2U

2D

3D4U

3U4D

3+4U

3+4D

For all types attention should be given to ensure that the channels shown correspond to the channels on the
chosen control box.

HB73..
08/H8

07/H7

05/H5

V0

3U

3D

1U

1D

3U

3D

H2

H3

1+2U

1+2D

3+4U

3+4D

1+2U

1+2D

H0

H1

4U

4D

2U

2D

1D2U

1U2D

H4

H5

HB74..

HB73..
V2

V1

0A/HA

00/E0

H13

H22

H23

2U

2D

1U

1D

H10

H11

H20

H21

1U

1D

3U

3D

H14

H15

H24

H25

3U

3D

2U

2D

4U

4D

1+2U

1+2D

H12

HB74..
07/H7

06/H6

03/H3

05/H5

3U

3D

1U

1D

1U

1D

3U

3D

1U

1D

3+4U

3+4D

3U

3D

1+2U

1+2D

4U

4D

2U

2D

4U

4D

4U

4D

3+4U

3+4D

1+2U

1+2D

3+4U

3+4D

3+4U

3+4D

HB74..
04/H4

V0

08/H8

02/H2

2U

2D

1U

1D

3U

3D

H2

H3

1U

1D

2U

2D

4U

4D

H0

H1

3U

3D

3+4U

3+4D

1+2U

1+2D

H4

H5

2+3U

2+3D

3D4U

3U4D

1D2U

1U2D

H6

H7

HB75..

HB74..

V1

V2

H12

0B/HB

0A/HA

H22

H23

1U

1D

1U

1D

3U
H10

H11

H20

H21

3U

3D

3U

3D

H14

H15

H24

H25

2U

2D

2U

2D

H26

H27

1+2U

1+2D

1+2U

1+2D

4U

4D

H17

H16

3U
4D

HB75..
02/H2

08/H8

07/H7

04/H4

1U

1D

2U

2D

1U

1D

3U

3D

2U

2D

1U

1D

3+4U

3+4D

4U

4D

1+2U

1+2D

3U

3D

2U

2D

3+4U

3+4D

3+4U

3+4D

2+3U

2+3D

1+2U

1+2D

1+2U

1+2D

3D4U

3U4D

4U

4D

3D4U

3U4D

1D2U

1U2D

HB75..
E0/EF

09/H9

V1

V0

3U

3D

2U

2D

H2

H3

H12

H13

1+2U

1+2D

1U

1D

H0

H1

H10

H11

4U

4D

3U

3D

H4

H5

H14

H15

3+4U

3+4D

4U

4D

H6

H7

H16

H17

1D2U

1U2D

5U

5D

H8

H9

H18

H19

HB72..

HB73..

HB75..

HB71..
EW/L0

EW/L0

V2

EW/L0

H22

H23

2U

2D

2U

2D

H20

H21

1U

1D

1U

1D

1U

1D

H24

H25

3U

3D

H26

H27

1

2

1

2

1

2

H28

H29

3

S

3

S

3

S

HB70 Standard front covers - when ordering check that the handset functionality corresponds to the symbols
on the front cover.
The last 2 digits in the front cover code are to be used in the ordering example (xx).

HBW071-00 HBW071-01

HBW072-01

HBW073-00

HBW072-03

HBW073-01

HBWW71-15

HBW071-19

HBW072-04

HBW072-33

HBW073-05

HBW073-06

HBW071W-01 HBW072-00

HBWW72-37

HBW072W-02

HBW073-34

HBW073-56

HBW074-00

HBW074-53

HBWW74-79

HBW075-00

HBWW75-48

HBW071-28

HBW072-47

Specifications subject to change without prior notice. It is the
responsibility of the product user to determine the suitability of
LINAK A/S products for a specific application. LINAK will at point
of delivery replace/repair defective products covered by the warranty if promptly returned to the factory. No liability is assumed
beyond such replacement/repair.

HBW074-01

HBW074-26

HBWW74-42

HBW075-01

HBW075-21

HBW075-25

Copyright© LINAK 2008.02 . MA M9-02-107-S . Chapter 9.4

HBWW73-61 HBW073W-01



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Format                          : application/pdf
Title                           : HB70_ver_s_eng.indd
Creator                         : CAS
Create Date                     : 2008:02:05 09:10+01:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2008:02:05 09:10:23+01:00
Metadata Date                   : 2008:02:05 09:10:23+01:00
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:614800a6-bea8-405e-8bf7-7aa77364d69f
Instance ID                     : uuid:53788f3a-2904-4df3-a457-2b8c02209a9c
Page Count                      : 8
Author                          : CAS
EXIF Metadata provided by EXIF.tools

Navigation menu