INTRODUCTION TM The AP-5 is designed for a broad range of access control applications. Its wireless design and small size make it easily adaptable for a variety of access control requirements. Typically, the AP-5 is used to control one or two door strikes, barrier gates, automatic gates, or door operators. The AP-5 contains a high-gain superheterodyne UHF receiver which uses an external antenna to pick up signals from up to 500 feet away. Up to 480 Linear MegaCode® transmitters and six Model MGT safety edge transmitters can be programmed into the AP-5’s memory. The AP-5 will retain its memory, even without power. Three dry contact relays are provided. The first relay (K1) is always for ACCESS. The second relay (K2) can be set for ACCESS or OBSTACLE. The third relay (K3) is always an OBSTACLE relay. An ACCESS relay can be programmed to be either timed or toggled. In timed mode, the relay can each be programmed to activate from 1 to 120 seconds (default 2 seconds). In toggle mode, activating a transmitter will latch the relay, activating the transmitter again will un-latch the relay. An OBSTACLE relay will activate for 2 seconds when a valid signal is received from a Model MGT transmitter. During an obstacle condition, all ACCESS relays will be disabled. For manual activation, pressing OPEN then the “1” key will activate relay K1. Pressing OPEN then the “2” key will activate relay K2. Each relay will activate for its programmed time only. If relay K2 is programmed as an OBSTACLE relay, it cannot be manually activated. Relays K1 and K2 can also be activated using the two OPEN REQUEST inputs. Each input (1 or 2) will activate an ACCESS relay (K1 or K2) for its timed amount, or as long as the input is active. OPEN REQUEST inputs override any MGT obstacle activity on relay K3 (but not on K2). ® AP-5 PRINTER’S INSTRUCTIONS: INSTR,INSTL,AP-5 - LINEAR P/N: 227701 A - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1; SIDE 1 OF 2 Multi-purpose Wireless Access Controller With High-gain Superheterodyne Receiver Installation Instructions (760) 438-7000 • FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com SAFETY WARNING The AP-5 can fully supervise up to six MGT safety edge transmitters stored in six memory locations (1-6). The system monitors each MGT transmitter for hourly status reports, tamper signals, and low battery signals. A beep will sound every 5 seconds if a fault occurs and the trouble source can be displayed by pressing #-1 then 1-6. A transmitter must be activated twice to trigger the ACCESS RELAY if a supervisory trouble condition exists on any MGT transmitter (unless the MGT has been suspended). MGT supervisory conditions can be canceled per individual unit, or globally. The AP-5 can be powered from 12-24 Volts AC or DC. The three Form C relay outputs can each switch up to 1 Amp @ 24 Volts AC/DC. An EARTH GROUND terminal is provided as a recommended connection for maximum lightning and static protection. MOUNTING SCREWS MODEL AP-5 RECEIVER F-81 CONNECTOR NUT AND LOCKWASHER WHIP ANTENNA AP-5 FEATURES DISPLAYS LAST 3 DIGITS OF THE TRANSMITTERS ID NUMBER DURING OPERATION AND PROGRAMMING. ALSO DISPLAYS MGT SUPERVISION STATUS AND SYSTEM UTILITY INFORMATION. MOVING DOOR OR GATE CAN CAUSE SERIOUS INJURY OR DEATH PROGRAM BUTTON PUSH FOR 3 SECONDS TO ENTER PROGRAM MODE. PRESS MOMENTARILY TO EXIT PROGRAM MODE. ANTENNA CONNECTOR NUMERIC KEYPAD DIGITAL DISPLAY FOR ENTERING TRANSMITTER ID NUMBERS, PROGRAMMING, AND UTILITY FUNCTION NUMBERS. POWER INDICATOR STAY CLEAR OF MOVING PARTS IF THIS UNIT IS MOUNTED INSIDE THE DOOR OR GATE OPERATOR! DISPLAY BUTTON ACCESS GRANTED INDICATOR SHIFTS THE DISPLAY TO SHOW THE LEFT THREE DIGITS OF THE 6-DIGIT TRANSMITTER ID NUMBER DURING OPERATION OR PROGRAMMING. LIGHTS WHEN ANY ACCESS RELAY IS ENERGIZED. SUSPENDED INDICATOR LIGHTS WHEN A SIGNAL IS RECEIVED FROM A TRANSMITTER THAT HAS BEEN SUSPENDED FROM USE, AND WHEN SUSPENDING A TRANSMITTER. CLEARS THE KEYPAD AND DISPLAY IN CASE OF AN INCORRECT PROGRAMMING ENTRY. ALSO CLEARS ANY SUPERVISORY TROUBLE CODES FROM AN MGT OBSTACLE TRANSMITTER. STAY CLEAR OF THE DOOR/GATE OR DISCONNECT THE ACCESS RELAY WIRES WHEN PROGRAMMING OR SERVICING THIS UNIT! ELECTRICAL CONNECTIONS OPEN REQUEST 2 N.C. K3 COM OBSTACLE RELAY N.O. EARTH GND OPEN REQUEST 1 N.C. K1 COM ACCESS RELAY N.O. N.C. K2 ACCESS OR COM OBSTACLE N.O. RELAY Connect K1, K2, & K3 AC2 N.O. or N.C. and COM AC1 terminals to access device trigger inputs MOUNT THE RECEIVER USING THE TWO SCREWS PROVIDED PB2 ACCESS DEVICE Obstacle Terminals ACCESS DEVICE Access or Obstacle Terminals EARTH GROUND Ground stake, cold water pipe or unified earth ground. Recomended! POWER INPUT Low voltage plug-in transformer or power from access device. DC - 12-24 VOLTS DC + AC/DC NOTES: 1. MOUNT RECEIVER IN AN AREA PROTECTED FROM THE ELEMENTS 2. IF USING THE LOCAL WHIP ANTENNA, THE HIGHER THE RECEIVER IS MOUNTED, THE BETTER THE RADIO RANGE WILL BE OPEN REQUEST PUSHBUTTONS Optional connections provide an external method to activate access devices connected to relays K1 & K2. PB1 ACCESS DEVICE Access Terminals STAR ( ) KEY DISPLAYS THE ID NUMBER OF THE LAST TRANSMITTER ACTIVATED. (USE THE DISPLAY BUTTON TO VIEW THE LEFT THREE DIGITS OF THE ID NUMBER.) 3. OPTIONALLY, MOUNT THE RECEIVER IN A METAL CABINET AND USE AN EXTERNAL ANTENNA CLOSE THE CASE AND SECURE IT USING THE TWO SCREWS PROVIDED LIGHTS WHEN THE UNIT IS IN PROGRAM MODE. POUND (#) KEY PRESS # THEN 1, 2, OR 3 FOR UTILITY FUNCTIONS: #-1 THEN 1-6 DISPLAYS MGT SUPERVISORY STATUS FOR OBSTACLE TRANSMITTERS 1-6. #-2 DISPLAYS NUMBER OF PROGRAMMED TRANSMITTERS. #-3 DISPLAYS NUMBER OF PROGRAMMED TRANSMITTER ID BLOCKS. RECEIVER INSTALLATION & SPECIFICATIONS AP-5 WIRING DIAGRAM PROGRAM MODE INDICATOR RADIO INDICATOR LIGHTS WHEN A RADIO SIGNAL ON THE RECEIVER'S FREQUENCY IS DETECTED. OPEN BUTTON PUSH OPEN THEN BUTTON 1 OR 2 TO ACTIVATE ACCESS RELAY ONE OR TWO. LIGHTS WHEN AC OR DC POWER IS APPLIED TO THE UNIT. FOR DIRECT CONNECTION TO THE LOCAL WHIP ANTENNA OR, WITH A COAX CABLE, TO A REMOTE ANTENNA. CANCEL BUTTON THIS UNIT CAUSES OPERATION OF A DOOR OR GATE MOTOR. Relay K1 = Access Only Relay K2 = Access or Obstacle Relay K3 = Obstacle Only CASE SCREWS 3-FOOT ANTENNA CABLE SPECIFICATIONS: SIZE: 4.5" W x 6" H x 1.5" D SUPPLY VOLTAGE: 12-24 VOLTS AC/DC OPERATING CURRENT: 250 mA MAXIMUM OPERATING TEMPERATURE RANGE: -22° TO +158° F (-30° TO +70° C) SENSITIVITY: -102 dBm MINIMUM BANDWIDTH (3 db): 300 KHz TYPICAL FREQUENCY: 318 MHz RELAY CONTACT RATING: 1 AMP @ 24 VOLTS AC/DC MAXIMUM NUMBER OF TRANSMITTERS: 480 MAXIMUM NUMBER OF TRANSMITTER BLOCKS: 238 MAXIMUM NUMBER OF FACILITY CODES: 4 ANTENNA INSTALLATION LOCAL WHIP ANTENNA ATTACH THE LOCAL WHIP ANTENNA DIRECTLY TO THE RECEIVER REMOTE FIXED ANTENNA REMOTE WHIP ANTENNA MOUNT THE F-81 CONNECTOR ON THE SURFACE USING THE LOCKWASHER AND NUT USE THE OPTIONAL EXA-1000 OR EXA-2000 ANTENNA MOUNTED AS HIGH AS POSSIBLE FOR THE BEST RADIO RANGE CONNECT TO THE RECEIVER WITH THE COAX CABLE AND SCREW THE WHIP ANTENNA TO THE F-81 CONNECTOR CONNECT TO THE RECEIVER WITH AN RG-59 COAX CABLE ATTACH WHIP ANTENNA TO THIS SIDE EXA-1000 ANTENNA EXA-2000 DIRECTIONAL ANTENNA F-81 CONNECTOR COAX TO RECEIVER – 1 – ADDING TRANSMITTERS STEP 1: PRESS PROGRAM DISPLAY: FOR 3 SECONDS ← ENTERS PROGRAM MODE ← READY FOR PROGRAMMING THEN: ← TRANSMITTER ADDING FUNCTION NUMBER STEP 2: PRESS ← SINGLE TRANSMITTER ID # OR STARTING TRANSMITTER BLOCK ID # (FROM 1-65535) STEP 3: PRESS ← ENTERS ID # STEP 4: PRESS ← COMPLETE ID # ENTRY PRINTER’S INSTRUCTIONS: INSTR,INSTL,AP-5 - LINEAR P/N: 227701 A - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1; SIDE 2 OF 2 OR STEP 7: PRESS STEP 1: PRESS PROGRAM FOR 3 SECONDS ← ENTERS PROGRAM MODE ← READY FOR PROGRAMMING THEN: DISPLAY: ← MGT TRANSMITTER ADDING FUNCTION NUMBER STEP 2: PRESS ← ENTER "2" FOR RELAY K2 ENTER "3" FOR RELAY K3 STEP 3: PRESS OR STEP 4: PRESS ← ENTER "1-6" FOR MGT MEMORY LOCATION NUMBER – 3 – ADDING MDKP OR MDTK KEYPADS STEP 1: PRESS PROGRAM FOR 3 SECONDS ← ENTERS PROGRAM MODE ← READY FOR PROGRAMMING THEN: DISPLAY: ← ADDING KEYPAD FUNCTION NUMBER STEP 2: PRESS STEP 3: PRESS ← ENTER "1" TO ACTIVATE RELAY K1 ENTER "2" TO ACTIVATE RELAY K2 OR ← ONE TO FIVE DIGIT KEYPAD TRANSMITTER ID CODE FOR THE PIN STEP 4: PRESS SKIP TO STEP 6 FOR SINGLE TRANSMITTERS ← ENDING TRANSMITTER STEP 5: PRESS BLOCK ID # (FROM 1-65535) STEP 6: PRESS – 2 – ADDING AN MGT TRANSMITTER STEP 5: PRESS ← ENTERS MGT ID # STEP 6: PRESS STEP 7: PRESS ← ENTER "1" FOR TIMED RELAY ENTER "0" TO TOGGLE RELAY ← MGT TRANSMITTER ID # (FROM 1-65535) STEP 5: PRESS PROGRAM ← EXITS PROGRAM MODE ← ENTER "1" FOR TIMED RELAY ENTER "0" TO TOGGLE RELAY OR REPEAT STEPS 2-5 FOR ADDITIONAL KEYPADS OR KEYPAD PIN CODES STEP 6: PRESS PROGRAM ← EXITS PROGRAM MODE – 4 – RELAY ACTIVATION TIME STEP 1: PRESS PROGRAM FOR 3 SECONDS ← ENTERS PROGRAM MODE ← READY FOR PROGRAMMING THEN: DISPLAY: ← RELAY ACTIVATION TIME FUNCTION NUMBER STEP 2: PRESS STEP 3: PRESS OR ← ENTER "1" FOR RELAY K1 ENTER "2" FOR RELAY K2 ← ENTER "01" TO "120" SECONDS FOR THE RELAY ACTIVATION TIME (TWO DIGITS REQUIRED) STEP 4: PRESS REPEAT STEPS 2-4 IF PROGRAMMING THE OTHER RELAY STEP 5: PRESS PROGRAM ← EXITS PROGRAM MODE NOTES: 1. IF THE TRANSMITTER ID # IS NOT LABELED ON THE TRANSMITTER, TRIGGER THE TRANSMITTER TO VIEW THE ID # ON THE AP-5 DISPLAY. USE THE STAR KEY TO REVIEW THE LAST RECEIVED ID # (PRESS THE DISPLAY BUTTON TO VIEW THE LEFT THREE DIGITS OF THE ID #) 2. RELAY K1 CANNOT BE PROGRAMMED AS AN OBSTACLE RELAY 3. IF RELAY K2 IS CONFIGURED FOR OBSTACLE, IT CANNOT BE CHANGED BACK TO ACCESS UNTIL THE ALL MGT TRANSMITTERS SET TO RELAY K2 ARE REMOVED NOTES: TO DETERMINE THE TRANSMITTER ID CODE SENT BY A KEYPAD WHEN A PARTICULAR PIN CODE IS ENTERED AT THE KEYPAD, OBSERVE THE AP-5 DISPLAY. 1. ENTER A PIN AND SEND A SIGNAL FROM THE KEYPAD 2. PRESS STAR ON THE AP-5 TO VIEW THE LAST THREE DIGITS OF THE ID CODE 3. PRESS DISPLAY ON THE AP-5 TO VIEW THE FIRST THREE DIGITS OF THE ID CODE – 5 – SET TRANSMITTER BUTTONS – 6 – SET FACILITY CODES – 7 – MGT TRANSMITTER SUPERVISION – 8 – SUSPENDING/ACTIVATING MGT TXS USE THESE STEPS TO CHANGE WHICH BUTTONS ON MULTI-BUTTON TRANSMITTERS WILL ACTIVATE WHICH ACCESS RELAY USE THESE STEPS ONLY IF TRANSMITTER BLOCKS HAVE BEEN ORDERED WITH A PRE-SET FACILITY CODE IF THE AP-5 BEEPS EVERY 5 SECONDS, ONE OR MORE MGT OBSTACLE TRANSMITTER HAS SENT A SUPERVISORY SIGNAL TO DISABLE MGT SUPERVISION ON A SPECIFIC TRANSMITTER AND PREVENT THE AP-5 FROM SOUNDING THE 5-SECOND MGT SUPERVISORY BEEPS REPEAT STEPS 2-7 TO ADD MORE TRANSMITTERS STEP 8: PRESS STEP 1: PRESS PROGRAM PROGRAM ← EXITS PROGRAM MODE NOTE: IF THE TRANSMITTER ID # IS NOT LABELED ON A TRANSMITTER, TRIGGER THE TRANSMITTER TO VIEW THE ID # ON THE AP-5 DISPLAY. USE THE STAR KEY TO REVIEW THE LAST RECEIVED ID # (PRESS THE DISPLAY BUTTON TO VIEW THE LEFT THREE DIGITS OF THE ID #) FOR 3 SECONDS ← ENTERS PROGRAM MODE STEP 1: PRESS PROGRAM FOR 3 SECONDS ← ENTERS PROGRAM MODE NOTE: WHEN ANY MGT HAS A SUPERVISORY CONDITION, TRANSMITTERS WILL HAVE TO BE TRIGGERED TWICE TO GAIN ACCESS ← UTILITY FUNCTION #1 THEN 1-6 TO DISPLAY STATUS FOR MGT TRANSMITTERS IN MEMORY LOCATIONS 1-6 PRESS ← TRANSMITTER BUTTON FUNCTION NUMBER (ENTER 21-25: 21 = LEFT; 22 = RIGHT; 23 = TOP; 24 = LOWER LEFT; 25 = LOWER RIGHT) STEP 2: PRESS OR STEP 3: PRESS STEP 4: PRESS STEP 5: PRESS ← READY FOR PROGRAMMING THEN: DISPLAY: OR PROGRAM ← ENTER "1" ACTIVATES RELAY K1 ENTER "2" ACTIVATES RELAY K2 ← ENTER "1" TO ENABLE BUTTON ENTER "0" TO DISABLE BUTTON 2. THE BUTTON SETTING WILL BE USED BY ALL TRANSMITTERS PROGRAMMED STEP 2: PRESS ← FACILITY CODE FUNCTION NUMBER STEP 3: PRESS ← RECEIVER FACILITY CODE LOCATION (FROM 1-4) ← INDICATES MGT TRANSMITTER LOW BATTERY – 9 – SUSPENDING/ACTIVATING TRANSMITTERS FOR 3 SECONDS ← ENTERS PROGRAM MODE ← TRANSMITTER STATUS FUNCTION NUMBER STEP 2: PRESS STEP 5: PRESS PROGRAM ← EXITS PROGRAM MODE ← AFTER CLEARING, DASHES INDICATE THAT NO SUPERVISORY CONDITIONS EXIST WITH THE MGT TRANSMITTER NOTES: 1. REPEAT STEPS 2-4, IF REQUIRED, FOR EACH OF THE FOUR RECEIVER FACILITY CODE LOCATIONS – 10 – REMOVING ALL TRANSMITTERS STEP 1: PRESS PROGRAM FOR 3 SECONDS ← ENTERS PROGRAM MODE PRESS CANCEL ← CLEARS MGT STATUS FROM AP-5 MEMORY AND STOPS BEEPER NOTE: PRESS CANCEL WITHOUT PRESSING #1 TO CLEAR MGT SUPERVISORY INDICATIONS FROM ALL MGT TRANSMITTERS – 11 – REMOVING MGT TRANSMITTERS STEP 1: PRESS PROGRAM THEN: DISPLAY: ← READY FOR PROGRAMMING ← TRANSMITTER REMOVING FUNCTION NUMBER STEP 2: PRESS FOR 3 SECONDS ← ENTERS PROGRAM MODE ← READY FOR PROGRAMMING THEN: STEP 2: PRESS ← MGT TRANSMITTER FUNCTION NUMBER STEP 4: PRESS ← ENTER "1-6" FOR MGT MEMORY LOCATION NUMBER ← REMOVE COMMAND STEP 3: PRESS ← TRANSMITTER ID # (FROM 1-65535) STEP 3: PRESS OR STEP 4: PRESS ← ENTER "0" TO SUSPEND XMTR ENTER "1" TO ACTIVATE XMTR REPEAT STEPS 2-4 TO SUSPEND OR ACTIVATE ADDITIONAL TRANSMITTERS STEP 5: PRESS PROGRAM STEP 3: PRESS ← REMOVE COMMAND STEP 4: PRESS ← VERIFY REMOVE COMMAND 2. ACTIVATED TRANSMITTERS CAN TRIGGER ANY ACCESS RELAY DISPLAY: STEP 4: PRESS THEN: PROGRAM ← MGT REMOVED ← EXITS PROGRAM MODE – 12 – SYSTEM TESTING DISPLAY: THEN: ← EXITS PROGRAM MODE NOTES: 1. SUSPENDED TRANSMITTERS CAN NOT TRIGGER ANY ACCESS RELAY, THE SUSPENDED INDICATOR WILL LIGHT INSTEAD PROGRAM FOR 3 SECONDS ← ENTERS PROGRAM MODE THEN: DISPLAY: STEP 5: PRESS PROGRAM ← EXITS PROGRAM MODE ← MEMORY CLEAR NOTES: 1. WARNING! ALL TRANSMITTERS INCLUDING THE MGT TRANSMITTER WILL BE REMOVED (TRANSMITTERS CANNOT BE INDIVIDUALLY REMOVED) 2. WARNING! ALL OTHER OPTIONS WILL BE RESET TO THE FACTORY DEFAULTS ← READY FOR PROGRAMMING STEP 2: PRESS ← MGT TRANSMITTER FUNCTION NUMBER STEP 3: PRESS ← ENTER "1-6" FOR MGT MEMORY LOCATION NUMBER ← SUSPEND/ACTIVATE COMMAND STEP 4: PRESS ← INDICATES THAT HOURLY STATUS REPORTS HAVE NOT BEEN RECEIVED FROM THE MGT TRANSMITTER IN THE PREVIOUS FOUR HOURS DISPLAY: ← READY FOR PROGRAMMING THEN: DISPLAY: STEP 1: PRESS ← INDICATES AN MGT TAMPER OR LOOP FAULT ← TRANSMITTER FACILITY CODE NUMBER (FROM 1-15; 0 = IGNORE FACILITY CODE) STEP 4: PRESS 2. WHEN THE TRANSMITTER FACILITY CODE IS SET TO "0", THE RECEIVER WILL ACCEPT ALL TRANSMITTERS REGARDLESS OF THEIR FACILITY CODE 3. REPEAT STEPS 2-4 TO PROGRAM OTHER BUTTONS PROGRAM ← READY FOR PROGRAMMING ← EXITS PROGRAM MODE NOTES: 1. THE FACTORY DEFAULT SETTING ONLY ALLOWS THE LEFT TRANSMITTER BUTTON TO ACTIVATE ACCESS RELAY K1 STEP 1: PRESS THEN: DISPLAY: NOTES: 1. THE FACTORY DEFAULT ACTIVATION TIME FOR ACCESS RELAYS IS TWO SECONDS 2. OBSTACLE RELAYS ALWAYS ACTIVATE FOR TWO SECONDS AND CANNOT BE PROGRAMMED DIFFERENTLY ACTIVATE A TRANSMITTER THAT HAS BEEN PROGRAMMED (AND IS NOT SUSPENDED) THE RADIO AND ACCESS GRANTED INDICATORS SHOULD LIGHT AND THE ACCESS DEVICE SHOULD OPERATE IF MGT OBSTACLE TRANSMITTERS ARE PROGRAMMED, RUN THE ACCESS DEVICE AND TRIGGER EACH OBSTACLE SENSOR VERIFY THAT THAT ACCESS DEVICE STOPS OR REVERSES IF OPEN REQUEST PUSHBUTTONS ARE INSTALLED, PRESS EACH ONE THE ACCESS GRANTED INDICATOR SHOULD LIGHT AND THE ACCESS DEVICE SHOULD OPERATE DISPLAY: ← MGT SUPERVISION CHANGED (SUSPEND INDICATOR LIGHTS FOR 2 SECONDS WHEN MGT HAS BEEN SUPSENDED) ← EXITS PROGRAM MODE THEN: STEP 5: PRESS PROGRAM NOTES: 1. USE THE SAME COMMAND TO ACTIVATE (UNSUSPEND) THE MGT TRANSMITTER 2. SUSPENDING AN MGT WITH A SUPERVISORY CONDITION WILL ALLOW TRANSMITTERS TO GAIN ACCESS WITH ONE ACTIVATION INSTEAD OF TWO LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twenty-four (24) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details. IMPORTANT!!! Linear radio controls provide a reliable communications link and fill an important need in portable wireless signalling. However, there are some limitations which must be observed. • The radios are required to comply with FCC Part 15 and Industry Canada Rules and Regulations. As such, they have limited transmitter power and therefore limited range. • A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings. • Changes or modifications to the device may void FCC compliance. • Infrequently used radio links should be tested regularly to protect against undetected interference or fault. • A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users. Copyright © 2007 Linear LLC 227701 A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-702 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2007:09:18 10:00:01-07:00 Create Date : 2007:08:30 13:06:30-07:00 Metadata Date : 2007:09:18 10:00:01-07:00 Format : application/pdf Title : 227701A.indd Creator : Copyright © 2006 Linear LLC Description : INSTR,INSTL,AP-5 Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:1ae5a16d-11a6-4521-9aa0-9c3715f84347 Instance ID : uuid:eb58e276-5eb9-43e0-9f95-3385c9c60c81 Page Count : 2 Subject : INSTR,INSTL,AP-5 Author : Copyright © 2006 Linear LLCEXIF Metadata provided by EXIF.tools