Trilogy
345 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs 1-800-ALA-LOCK
For Technical Service 1-800-645-9440

DL2700 Programming
Instructions
OI209A 2/04

© ALARM LOCK 2004

CONGRATULATIONS!
Your new Alarm Lock Trilogy electronic digital lock is a rugged entry lock
of advanced design with several programmable features. Three security
levels are provided: Master (can perform ALL functions), Manager (can
perform MOST functions plus entry), and Basic User (entry only).
The lock includes 100 User Codes (consisting of Managers and Basic
Users), plus three "one-time entry" Service Codes. The Manager/Basic
User Codes are organized similar to a grid--ten banks of ten Access
Codes.
Take the time to read through this guide to familiarize
yourself with the features and operations of the lock,
and its quick and easy programming procedures.
Features
• 1 Master Code (all functions including entry)
• 10 Manager Codes (perform SOME programming
functions plus entry)
• 90 Basic User Access Codes (Entry Only)
• 3 Service Codes ("One-Time Entry" Codes)
• Two User Disable Modes:
• All User Codes Disabled Except Master Code
• All User Codes in a Bank Disabled Except
Manager Codes
• 30-Second Keypad Anti-Tamper Lockout:
(Keypad Lockout After 3 Unsuccessful User Code
Entries)
• Programmable Relay Functions:
(Relay may be keypad programmed to energize
on any keypress 0-9 or on unlock).

DL2700

QUICK LOOKUP
Wiring ................................................................ 2
Quick Start ....................................................... 2
Testing Codes ................................................... 3
Manager & User Location Worksheet ............... 4
Manager & User Location Example .................. 5
Programming Worksheet: Functions ................. 6
Change Existing Master Code ...................... 7
Add/Change Manager Codes ....................... 7
Add/Change User Codes.............................. 7
Deleting Codes ............................................. 7
Disable/Enable Users ................................... 7
Disable/Enable All ........................................ 8
Code Location Function................................ 8
Next Free Code Address Locator ................. 8
Add/Delete Service Codes .......................... 9
Enable/Disable Passage Mode .................... 9
Pass Time ("Door Unlock") ........................... 9
Disable/Enable Groups................................. 9
Disable/Enable Users in Bank .................... 10
Keypress Sound Options ............................ 10
AUX Relay Functions ................................. 10
Lock Identifier ............................................. 10
Audible and LED Indications ........................... 11
Battery Replacement ....................................... 11
Erase All Programming ................................... 11
Limited Warranty ............................................. 12

© ALARM LOCK 2003
1

Wiring
See the Installation Instructions for more information.
Batteries:
Use only 1.5 volt Duracell Alkaline size-AA batteries.
External Power:
An external 7.5 VDC Power Source, capable of at
least 100mA, must be used for operation without
batteries in the lock. Use an external UL-Listed
power supply provided with backup battery power
and current limiting protection that is approved for
the application.
BLACK = Negative, RED = Positive.

Aux Relay:
Aux Relay allows up to 300mA @ 60VDC Maximum.
See page 10 for programming options for the
Relay ("AUX Relay Functions").
BLUE = Common, YELLOW = N/O, GREEN = N/C.
Remote Switch Input (2 White Wires)
A remote momentary switch can be wired to allow
access when activated. Wire a normally open
push button switch to the two white wires. Press
for one second to unlock the DL2700.

Quick Start
First Time Start Up
1. Unpack the lock from its factory packaging.
2. With the batteries disconnected, hold down the 5 key (or any numeric key) for 10 seconds and release.
3. Connect the batteries and--within 3 seconds--press and hold the ; button. After hearing 6 beeps, release
the ; button. Wait 5 seconds for lock to re-lock (listen for 1 beep and red LED). This will clear the lock of
all programmed data, and the lock is now ready to accept programming. Note: Failure to follow this exact
procedure can result in erratic lock behavior.
Important Note: When entering any key sequence below, do not pause more than 5 seconds between any key
presses--otherwise you must start again. (Note: If you wish, this 5-second delay between key presses can
be extended--see Pass Time on page 9 after completing this section).
No other programming commands will be accepted until the Factory Master Code has been changed.

Change Factory Master Code
The Master Code is a "secret" code (entered at the keypad) that allows you to change ALL programming functions
and options. Because all locks are manufactured identically (and leave the factory with the same Master Code),
this "factory Master Code" is not very secret--and MUST be changed to your own personal Master Code to ensure
security. A 5 digit Code is recommended.
1. Press the factory Master Code: 1 2 3 4 5. A beep will sound and the lock will open.
2. Within 5 seconds, press ; 1 ;.
3. Within 5 seconds, enter a new Master Code. This new Master Code may consist of 3 to 5 digits*, however, the
number selected determines the number required for all subsequent Manager and User Access Codes.
4. Press ;.
5. Re-enter the new Master Code again to validate. A 6-beep acknowledgement (with a red LED) will sound.
Wait 5 seconds for lock to re-lock.
6. Test the new Master Code. Enter the new Master Code; a beep will sound and the lock will unlock. Now that
the Master Code has been changed, there is no need to change it again (unless you want to).
For example, if you want your new Master Code to be "44444", press:
1 2 3 4 5 ; 1 ; 44444 ; 44444.

If you wish, write your new Master Code in the spaces provided:
1 2 3 4 5 ; 1 ; ____ ____ ____ ____ ____ ; ____ ____ ____ ____ ____
Write your new Master Code

(Repeat)

Continued

* Once the number of digits is selected, it cannot be changed unless all programming is erased and the Factory Default settings are re-loaded
using the "Erase All Programming" procedure found on page 11.

2

Quick Start (cont’d)
Enter a Manager Code
Manager Codes are located at locations 00, 10, 20, 30, 40, 50, 60, 70, 80, and 90 (see grid on page 4). Note:
New Manager Codes MUST use the same number of digits as the (new) Master Code. Enter as follows.
1. Press the (new) Master Code.
2. Press ; [press a Manager location i.e. 00, 10, 20, 30, 40, 50, 60, 70, 80, or 90] ;.
3. Press a new Manager Code using the same number of digits as the (new) Master Code. A 6-beep acknowledgement (with a red LED) will sound. Wait 5 seconds for lock to re-lock.
For example, if you want to add a Manager Code of "33333" in location 00,
[Press the (new) Master Code] ; 00 ; 33333.
4. If lock remains open, repeat from step 2; otherwise restart from step 1 for each new Manager Code.

Enter Basic User Access Codes
See the grid on page 4 for more information regarding User locations. You can choose to enter your User Codes
in many possible locations, and in any order you wish. User Codes do not have programming privileges (entry
only). Duplicate User Codes are not allowed.
1. Press the (new) Master Code or associated Manager Code.
2. Press ; [press a 2-digit location number] ;.
3. Press a new User Access Code using the same number of digits as the (new) Master Code. A six-beep acknowledgement (with a red LED) will sound. Wait 5 seconds for lock to re-lock. The new User Access Code is
now entered in that location number.
For example, if you want to add a User Access Code of "22222" in User Number 01, press:
[(New) Master Code] ; 01 ; 22222.
4. If lock remains open, repeat from step 2; otherwise restart from step 1 for each new User Access Code.

Delete a User Access Code
The Master Code cannot be deleted. Manager Codes can only be deleted with the Master Code. If the location
(User Number) of the Code is unknown, use the Code Location Function (page 8).
1. Press the (new) Master Code or Manager Code.
2. Press ; [press the 2-digit location number] ; :. A six-beep acknowledgement (with a red LED) will
sound. Wait 5 seconds for lock to re-lock. The User Access Code is now deleted.
For example, if you want to delete a User Access Code located in location 47, press:
[(New) Master/Manager Code] ; 4 7 ; :.
3. If lock remains open, repeat from step 2; otherwise restart from step 1 for each User Access Code you want to
delete.

Testing Codes
VALID CODE - The Green LED will flash (with 1 beep) after a valid code is entered. The lock will unlock immediately and
remain unlocked for about 5 seconds (this "unlocked" time is the "Pass Time"). To make the Pass Time longer or
shorter, use the Pass Time Function on page 9. Note: While the lever or knob may be rotated at any time, the latch
will not be engaged to unlock the door unless a valid User Access Code is entered at the keypad.
INVALID CODE - The Red LED will flash 5 times (with 5 beeps) after an invalid code is entered. (To quickly clear an invalid
User Access Code, press ; and immediately re-enter the correct Code).
KEYPAD ANTI-TAMPER LOCKOUT - If 3 invalid User Access Codes are entered in succession, the lock will turn off for
approximately 30 seconds to prevent tampering. The DL2700 will emit 2 beeps with a Red LED flash warning at the
end of the anti-tamper period. The lock will exit Anti-Tamper mode in 30 seconds or upon activation of the Remote
Switch Input (white wires). Note: The lock will go into Anti-Tamper after 3 unsuccessful Code entries even if entered
by different users and spaced apart in time. Therefore, the lock may “appear” to go into Anti-Tamper Lockout even
after the entry of just one invalid User Access Code.

3

Manager & User Location Worksheet
The DL2700 lock provides three "security levels": Master (can perform ALL functions), Manager (can perform SOME programming functions plus entry), and Basic User (entry only). In total, there are 104 "locations" inside the DL2700 lock: one Master
Code, 10 Manager and 90 User Access Codes, and three "one-time entry" Service Codes. Where the Access Code is located
will determine its security level. From the factory, all locations (except for the Master Code) are empty; each location can then be
programmed to contain an Access Code, and these Access Codes enable Users to program and/or unlock the lock. As a visual
aid, the 100 Manager/User Access Code locations are detailed in the grid below, with ten "Banks" (columns) of ten "Managers/
Users" (rows). Each of the 100 squares in the grid is identified by a unique two-digit location (00) through (99). Notice that these
two digits also specify its Bank (column) and Manager/User (row) location in the grid. Also notice that all Managers are in the top
row, their locations all ending in a zero (locations 00, 10, 20, 30 and so on through 90). Note: Use the blank grid below as a Programming Worksheet for preparing all programming in advance. Store this worksheet in a safe place for future reference.
Each square represents a location inside the lock (excluding the Master Code and the 3 Service
Codes). Each location can hold one "User Access Code" which can unlock the lock.

MANAGERS
→

BANK 0

BANK 1

BANK 2

BANK 3

BANK 4

BANK 5

BANK 6

BANK 7

BANK 8

BANK 9

MGR 00

MGR 10

MGR 20

MGR 30

MGR 40

MGR 50

MGR 60

MGR 70

MGR 80

MGR 90

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

USER 01

USER 11

USER 21

USER 31

USER 41

USER 51

USER 61

USER 71

USER 81

USER 91

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

USER 02

USER 12

USER 22

USER 32

USER 42

USER 52

USER 62

USER 72

USER 82

USER 92

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

USER 03

USER 13

USER 23

USER 33

USER 43

USER 53

USER 63

USER 73

USER 83

USER 93

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

USER 04

USER 14

USER 24

USER 34

USER 44

USER 54

USER 64

USER 74

USER 84

USER 94

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

USER 05

USER 15

USER 25

USER 35

USER 45

USER 55

USER 65

USER 75

USER 85

USER 95

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

USER 06

USER 16

USER 26

USER 36

USER 46

USER 56

USER 66

USER 76

USER 86

USER 96

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

USER 07

USER 17

USER 27

USER 37

USER 47

USER 57

USER 67

USER 77

USER 87

USER 97

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

USER 08

USER 18

USER 28

USER 38

USER 48

USER 58

USER 68

USER 78

USER 88

USER 98

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

USER 09

USER 19

USER 29

USER 39

USER 49

USER 59

USER 69

USER 79

USER 89

USER 99

_____

_____

_____

_____

_____

_____

_____

_____

_____

_____

USERS
→

USERS
→

USERS
→

USERS
→

USERS
→

USERS
→

USERS
→

USERS
→

USERS
→

MASTER CODE
LOCK DESCRIPTION

4

SERVICE CODE 1

SERVICE CODE 2

SERVICE CODE 3

Manager & User Location Example
User Access Codes allow access only; Manager Codes allow more: Manager Codes have the ability to program and delete
User Access Codes within that Manager's Bank (column). The DL2700 lock can hold up to 10 Manager Codes, one for
each Bank (locations (00), (10), (20), (30), (40), (50), (60), (70), (80), (90)), and are all found at the top row of the grid below. Note: Only the Master Code can add or delete a Manager Code.
In addition, Managers not only possess programming abilities for User Access Codes residing in their own Bank, but also
for all higher Banks until the next programmed Manager Code appears.
For example (see shaded grid below), if Manager Codes are programmed for locations (00) and (60), then the Manager in
location (00) has control of the gray-shaded locations (00-09, 11-19, 21-29, 31-39, 41-49, and 51-59). The Manager in location (60) then has control over the black-shaded locations (61-69, 71-79, 81-89, and 91-99).
Note: If you wish to grant any Manager the ability to program any User, use the "Disable Groups" Function on page 9
(Enter the Master Code, then press ; 211 ;).
Manager Code
Programmed here

Manager Code
Programmed here
(BANK 0)

(BANK 1)

(BANK 2)

(BANK 3)

(BANK 4)

(BANK 5)

(BANK 6)

(BANK 7)

(BANK 8)

(BANK 9)

MGR 00

MGR 10

MGR 20

MGR 30

MGR 40

MGR 50

MGR 60

MGR 70

MGR 80

MGR 90

(BLANK)

(BLANK)

(BLANK)

(BLANK)

(BLANK)

(BLANK)

(BLANK)

(BLANK)

USER 01

USER 11

USER 21

USER 31

USER 41

USER 51

USER 61

USER 71

USER 81

USER 91

USER 02

USER 12

USER 22

USER 32

USER 42

USER 52

USER 62

USER 72

USER 82

USER 92

USER 03

USER 13

USER 23

USER 33

USER 43

USER 53

USER 63

USER 73

USER 83

USER 93

USER 04

USER 14

USER 24

USER 34

USER 44

USER 54

USER 64

USER 74

USER 84

USER 94

USER 05

USER 15

USER 25

USER 35

USER 45

USER 55

USER 65

USER 75

USER 85

USER 95

USER 06

USER 16

USER 26

USER 36

USER 46

USER 56

USER 66

USER 76

USER 86

USER 96

USER 07

USER 17

USER 27

USER 37

USER 47

USER 57

USER 67

USER 77

USER 87

USER 97

USER 08

USER 18

USER 28

USER 38

USER 48

USER 58

USER 68

USER 78

USER 88

USER 98

USER 09

USER 19

USER 29

USER 39

USER 49

USER 59

USER 69

USER 79

USER 89

USER 99

MANAGERS
→

USERS
→

USERS
→

USERS
→

USERS
→

USERS
→

USERS
→

USERS
→

USERS
→

USERS
→

Manager Location Example

5

Programming Worksheet: Functions
Directions: The Factory Master Code (1-2-3-4-5) must first be reprogrammed as a new Master Code before any other programming
can take place. All new Access Codes must have the same number of digits as the new Master Code. Choose new Access Codes
and write them in spaces provided (in pencil) before programming the lock. 6 beeps will usually be heard after an acceptable entry.
FUNCTION
Change Existing Master Code

PRESS THESE BUTTONS ON KEYPAD
[Enter Factory or Existing Master Code] ;1; [Enter New Master Code _ _ _ _ _ ] ;
[Re-enter New Master Code _ _ _ _ _ ] [6 beeps = OK]

Add/Change Manager Codes (up to 10) [Enter Master Code] ; [Enter 2-digit Manager Location _ _ ] ;
[Enter new Manager Code _ _ _ _ _ ] [6 beeps = OK]
Add/Change User Codes (up to 90)

Press Master or Manager Code ; [Enter 2-digit Location _ _ ] ; [Enter new User Code _ _ _ _ _ ]
[6 beeps = OK]

Deleting Manager & User Codes

Press Master or Manager Code ; [Enter Bank Number] [Enter User Number] ;:

Disable User Number

Press Master or Manager Code ; [Enter Bank Number] [Enter User Number] ;

Enable User Number

Press Master or Manager Code ; [Enter Bank Number] [Enter User Number] ;

Disable All

Press Master or Manager Code ; 9 5 5 ; (Reset with Function 944)

Enable All

Press Master or Manager Code ; 9 4 4 ;

Disable Users Only

Press Master or Manager Code ; 9 5 0 ; (Reset with Function 944)

Code Location Function

Press Master or Manager Code ; 6 ; [Enter Code to be located]

Next Free Code--Address Locator

Press Master or Manager Code ; 7 ; [Responds with Bank # and User #]

Service Code 1

Press Master or Manager Code ; 3 0 1 ; [Enter new Service Code _ _ _ _ _ ]

Service Code 2

Press Master or Manager Code ; 3 0 2 ; [Enter new Service Code _ _ _ _ _ ]

Service Code 3

Press Master or Manager Code ; 3 0 3 ; [Enter new Service Code _ _ _ _ _ ]

Clear Service Codes

Press Master or Manager Code ; 3 0 0 ;

Enable Passage Mode

Press Master or Manager Code ; 4 ;

Disable Passage Mode

Press Master or Manager Code ; 5 ;

Pass Time ("Door Unlock")

Press Master Code ; 4 [Enter "02" - "20" seconds] ;

Enable Groups

Press Master Code ; 2 1 0 ;

Disable Groups

Press Master Code ; 2 1 1 ;

Disable Users In Bank

Press Master or Manager Code ; 8 5 [Enter Bank Number (0-9)] ;

Enable Users in Bank

Press Master or Manager Code ; 8 4 [Enter Bank Number (0-9)] ;

High Freq KP Feedback + Led

Press Master Code ; 2 2 0 ;

Low Freq KP Feedback + Led

Press Master Code ; 2 2 1 ;

Click! KP Feedback + Led

Press Master Code ; 2 2 2 ;

Led Only

Press Master Code ; 2 2 3 ;

Disable AUX Relay Function

Press Master Code ; 2 0 0 ;

AUX Relay on any First Keypress (0-9)

Press Master Code ; 2 0 1 ;

AUX Relay When Unlocked

Press Master Code ; 2 0 2 ;

Lock Identifier

[Any Digit] [Any Digit] : [Listen for musical tones]

Note: Managers do not have the ability to add/delete/enable/disable Users outside their Bank, unless Groups are disabled.

6

Programming Functions
Change Existing Master Code* ; 1 ;
For new locks, follow the "Quick Start" on page 2.

[ __ __ __ __ __ ]

;1;

[ __ __ __ __ __ ] ; [ __ __ __ __ __ ]

Old (or "Factory") Master Code

New Master Code*

Confirm New Master Code*

Add/Change Manager Codes ; [ __ ] 0 ;
Follow the "Quick Start" on page 3. Note: You can also add/change the Manager Code in location
00 by entering the Master Code, ; 2 ; then the new Manager Code.

[ __ __ __ __ __ ]

; [ __

] 0 ; [ __ __ __ __ __ ]

Master Code**

New Manager Code

Manager Bank (Column) 0-9

User (Row) Always zero for Managers

Add/Change User Codes ; [ __ __ ] ;
Follow the "Quick Start" on page 3.

[ __ __ __ __ __ ]
Master Code or
Manager Code**

;

[ __ __ ] ; [ __ __ __ __ __ ]
New User Code

Bank (Column)
0-9

User (Row)
1-9

Deleting Manager & User Codes ; [ _ _ ] ; :
Follow the "Quick Start" on page 3.

[ __ __ __ __ __ ]

; [__] ; :

Master or Manager Code**
Manager Bank (Column)
0-9

User (Row) Always zero for Managers
0-9

Disable/Enable Users
Enter the Master Code to disable/enable any Manager or User, or enter a Manager Code to disable any User
within the Manager's Bank.

Disable User Number

[ __ __ __ __ __ ]

;

Master or Manager Code

Enable User Number

[ __ __ __ __ __ ]
Master or Manager Code

[ __ __ ]

; (Allow system to relock)

Bank/User Number

;

[ __ __ ]

; (Allow system to relock)

Bank/User Number

* Once the number of digits is selected, it cannot be changed unless all programming is erased and the Factory Default settings are re-loaded
(power must be removed and re-applied as per the "Erase All Programming" procedure found on page 11.
** Required only if DL2700 is locked.
7

Programming Functions (cont'd)
Enable/Disable All
Disable All: If Master Code is used, disables all 100 User\Manager Codes and clears all 3 Service Codes. If
a Manager Code is used, disables all Users (even across multiple Banks) under that Manager.
Disable Users Only: If Master Code is used, disables all 90 Users and clears all 3 Service Codes, while Managers remain active. If a Manager Code is used, disables all Users (even across multiple banks) under that Manager.
Enable All: If Master Code is used, re-enables all 100 User/Manager Codes (Service Codes must be reprogrammed). If a Manager Code is used, re-enables all Users (even across multiple Banks) under that Manager. Note: Managers cannot disable themselves. Use Function 944 to restore Functions 955 and 950. In
addition, if Codes are disabled using Function 955 or 950, and a new User Code is subsequently added (or an
existing Code changed), the new (or changed) User Code will automatically become enabled.

Disable All

[ __ __ __ __ __ ] ; 9 55 ;
Master/Manager Code**

Disable Users Only

[ __ __ __ __ __ ] ; 9 50 ;
Master/Manager Code**

Enable All

[ __ __ __ __ __ ] ; 9 44 ;
Master/Manager Code**

Code Location Function ; 6 ;
Be sure to record all Code locations in the blank worksheet (page 4) for future reference. If the location of a Code is
not known, use this function to find the Code. The lock will identify the BANK (0-9) and USER (0-9) by beeping and
flashing the GREEN LED 0 to 9 times as detailed below.

[ __ __ __ __ __ ] ; 6 ; [ __ __ __ __ __ ]
Master/Manager Code**

Code 2 - 5 digits

If the code entered is recognized, the following sequence will occur:
1. At the start of the Code Location sequence, the lock will Flash both the GREEN and RED LEDs and will emit a low tone.
2. The lock will identify the Bank number by flashing the GREEN LED and beeping the sounder from 0 -9 times.
3. To signify the end of the Bank number ID sequence, the lock will flash both the GREEN and RED LEDs and will emit a low tone.
4. The lock will identify the User number by flashing the GREEN LED and beeping the sounder from 0-9 times.
5. To signify the end of the Code Location function, the lock will flash both the GREEN and RED LEDs and will emit a low tone.
Note: Should the Code not be recognized, the lock will sound 5 beeps with a RED LED. When the Bank and/or slot numbers are
zero, the GREEN LED will not flash and the sounder will not beep.

Next Free Code Address Locator ; 7 ;
Using the same method of beeps and flashes used in the Code Location Function, and dependent on the Master or Managers Code entered, the lock will report the next available address for User Access Code programming.

[ __ __ __ __ __ ]

;7;

Master/Manager Code**

Report Sequence
1. At the start of the Next Free Code Location function, the lock will Flash both the GREEN and RED LEDs and will emit a low tone.
2. The lock will identify the Bank number by flashing the GREEN LED and beeping the sounder from 0 -9 times.
3. To signify the end of the Bank number ID sequence, the lock will flash both the GREEN and RED LEDs and will emit a low tone.
4. The lock will identify the User number by flashing the GREEN LED and beeping the sounder from 0-9 times.
5. To signify the end of the Code Location function, the lock will flash both the GREEN and RED LEDs and will emit a low tone. If no free
address is found, then the lock will emit a programming error tone sequence. No LED flashes/sounder beeps represent the number
zero.

** Required only if DL2700 is locked.
8

Programming Functions (cont'd)
Add/Delete Service Codes
Service Codes are one-time-only Codes; once entered into the keypad, it is deleted. Use the same Code up
to 3 times by programming all three Service Codes with the same Code. Note: Service Codes are lost if
power is removed. To delete a single Service Code, press ;, enter Service Code number (301, 302 or
303), then press ; :.

Service Code 1

[ __ __ __ __ __ ]

; 301 ;

Master/Manager Code**

Service Code 2

[ __ __ __ __ __ ]

New Service Code

; 302 ;

Master/Manager Code**

Service Code 3

[ __ __ __ __ __ ]

[ __ __ __ __ __ ]
New Service Code

; 303 ;

Master/Manager Code**

Delete All Service Codes

[ __ __ __ __ __ ]

[ __ __ __ __ __ ]
New Service Code

[ __ __ __ __ __ ]

; 300 ;

Master/Manager Code**

Enable/Disable Passage Mode
Allows passage without the need to enter a Code into the keypad.

Enable Passage Mode

[ __ __ __ __ __ ]

; 4 ; ("Unlocked")

Master or Manager Code**

Disable Passage Mode

[ __ __ __ __ __ ]

; 5 ; ("Normal Operation")

Master or Manager Code**

Pass Time ("Door Unlock")
The Pass Time is the time the lock stays unlocked after a valid Code entry. Use the function below to change
the Pass Time from 02 to 20 seconds. The Pass Time factory default is 5 seconds. NOTE: The Pass Time
will also determine the amount of time allowed between keypresses during programming.

Pass Time

[ __ __ __ __ __ ]

; 4 [ __ __

Master Code**

];

Pass Time

Disable/Enable Groups
Disable Groups: All Managers can program all User Access Codes, regardless of Bank.
Enable Groups: (Factory default) Managers restricted to controlling only those User Access Codes within
their own Bank (column), and all following Banks until another Manager appears. User Access Codes in
Banks outside of that Manager's Bank cannot be programmed.

Disable Groups

[ __ __ __ __ __ ]

; 211 ;

Master Code**

Enable Groups

[ __ __ __ __ __ ]

; 210 ;

Master Code**

** Required only if DL2700 is locked.
9

Programming Functions (cont'd)
Disable/Enable Users in Bank
Enter Bank number (0-9) to Enable/Disable all Users in Bank. Entering a disabled Code will result in an
accented five beep error tone (indicating the User Access Code is valid but disabled).

Disable Users in Bank

[ __ __ __ __ __ ]

; 8 5 [ __

Master/Manager Code**

Enable Users in Bank

]

;

Bank Number

[ __ __ __ __ __ ]

; 8 4 [ __

Master/Manager Code**

]

;

Bank Number

Keypress Sound Options
The DL2700 is capable of emitting 1 of 4 possible keypress sounds:
• High Frequency Keypad Feedback + Led
• Low Frequency Keypad Feedback + Led
• "Click!" Keypad Feedback + Led
• Led Only

High Freq KP Keypress Sound + Led
(Default)

[ __ __ __ __ __ ]

Low Freq KP Keypress Sound + Led

[ __ __ __ __ __ ]

; 220 ;

Master Code**

; 221 ;

Master Code**

Click! KP Keypress Sound + Led

[ __ __ __ __ __ ]

; 222 ;

Master Code**

Led Only

[ __ __ __ __ __ ]

; 223 ;

Master Code**

AUX Relay Functions
Program the functions below to activate the Auxiliary Relay on any numeric keypress (Function 201), or when
the DL2700 is unlocked (Function 202). In either case the Aux Relay will be active for the duration
programmed in Pass Time. See page 2 for information regarding the wiring of AUX leads.

Disable AUX Relay Function

[ __ __ __ __ __ ]

;200;

Master Code**

AUX Relay on Any First Keypress (0-9)

[ __ __ __ __ __ ]

;201;

Master Code**

AUX Relay When Unlocked

[ __ __ __ __ __ ]

;202;

Master Code**

Lock Identifier
To aid in distinguishing your lock model from earlier Alarm Lock versions, your DL2700 model will respond to
any two digits plus the star key by (1) lighting the green LED and (2) playing a musical scale of 8 notes.

Lock Identifier

[ __ ] [ __ ] :
(Any Two Digits)

10

** Required only if DL2700 is locked.

Audible and LED Indications
When a key is pressed, a beep will sound and a Red LED will flash. Other indications are:
▪ Access Granted: 1 beep and a Green LED flash. (When Pass Time ends, the DL2700 locks with a beep and a
Red LED flash).
▪ Invalid Code Entered: 5 beeps and 5 Red LED flashes.
▪ Disabled Code Entered: 5 beeps (with extended first beep) and 5 Red LED flashes.
▪ New Access Code Accepted: 6 beeps and 6 Red LED flashes.
▪ Programming Error: 2 sets of 5 beeps and 5 Red LED flashes.
▪ Return from Anti Tamper Lockout: 2 beeps with a Red LED flash.
▪ Low Battery: High/Low sounder with flashing Red LED for 5 seconds. (See below to replace batteries).
Note: Keypress tones may be disabled using the ; 2 2 3 ; command (see Keypress Sound
Options, page 10).

Battery Replacement
When the batteries are weak and a key is pressed, the lock will alert you by flashing the RED LED accompanied by a
high/low sounder. The DL2700 uses five AA-size 1.5 volt alkaline batteries. The lock will function with weak batteries;
however be sure to replace them as soon as possible.
If the DL2700 is ever without power for less than 1 minute (such as when replacing batteries), the DL2700 will continue its operation undisturbed--programming remains unaffected due to power provided by capacitors inside the lock.
If the DL2700 is without power for greater than one minute, you have two choices--you can (1) retain the lock programming or (2) erase all programming. If you choose to erase all programming, the DL2700 will revert to its original
factory default configuration ("out of the box").
CAUTION: Do not press any keys while batteries are disconnected unless you intend to erase all programming.
1. Remove the screw at the rear of the lock housing and remove the cover.
2. Remove battery pack and replace all 5 batteries quickly - within 1 minute.
3. Replace battery pack and cover. Tighten the cover screw to secure.
If you accidentally press a key (or fail to replace the batteries within 1 minute), use the Retain Lock Programming
procedure below:
Retain Lock Programming
1. Re-install battery pack.
2. Do not press any keys for 10 seconds.
If you do not hear any beeps or if you hear 3 beeps (one per second), the previous lock programming is retained and
the lock is now ready for use. If you test the DL2700 and find the lock programming is lost, you may erase all programming and return the DL2700 to its original factory settings, as described below.

Erase All Programming
Restore Factory Default (original settings that were set at the factory will be loaded).
1. Remove the battery pack, and with the batteries disconnected, press any numeric key for 10 seconds and release.
2. Connect the batteries and--within 3 seconds--press and hold ;. After hearing 6 additional beeps, release ;.
The DL2700 is now clear of all programmed data, and the lock is now ready to accept new programming. Important: If
you do not hear these 6 beeps, you must start over at step 1.

! Failure to follow this exact procedure can result in erratic lock behavior.
11

Alarm Lock Limited Warranty
ALARM LOCK SYSTEMS, INC. (ALARM LOCK)
warrants its products to be free from manufacturing
defects in materials and workmanship for 24 months
following the date of manufacture. ALARM LOCK will,
within said period, at its option, repair or replace any
product failing to operate correctly without charge to
the original purchaser or user.
This warranty shall not apply to any equipment, or
any part thereof, which has been repaired by others,
improperly installed, improperly used, abused, altered,
damaged, subjected to acts of God, or on which any
serial numbers have been altered, defaced or
removed. Seller will not be responsible for any
dismantling or reinstallation charges.
THERE ARE NO WARRANTIES, EXPRESS OR
IMPLIED, WHICH EXTEND BEYOND THE
DESCRIPTION ON THE FACE HEREOF. THERE IS
NO EXPRESS OR IMPLIED WARRANTY OF
MERCHANTABILITY OR A WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE.
ADDITIONALLY, THIS WARRANTY IS IN LIEU OF
ALL OTHER OBLIGATIONS OR LIABILITIES ON
THE PART OF ALARM LOCK.
Any action for breach of warranty, including but not
limited to any implied warranty of merchantability, must
be brought within the six months following the end of
the warranty period. IN NO CASE SHALL ALARM
LOCK BE LIABLE TO ANYONE FOR ANY
CONSEQUENTIAL OR INCIDENTAL DAMAGES
FOR BREACH OF THIS OR ANY OTHER
WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE
LOSS OR DAMAGE IS CAUSED BY THE SELLER'S
OWN NEGLIGENCE OR FAULT.
In case of defect, contact the security professional
who installed and maintains your security system. In
order to exercise the warranty, the product must be
returned by the security professional, shipping costs
prepaid and insured to ALARM LOCK. After repair or
replacement, ALARM LOCK assumes the cost of
returning products under warranty. ALARM LOCK
shall have no obligation under this warranty, or
otherwise, if the product has been repaired by others,
improperly installed, improperly used, abused, altered,
damaged, subjected to accident, nuisance, flood, fire
or acts of God, or on which any serial numbers have
been altered, defaced or removed. ALARM LOCK will
not be responsible for any dismantling, reassembly or
reinstallation charges.
This warranty contains the entire warranty. It is the
sole warranty and any prior agreements or
representations, whether oral or written, are either
merged herein or are expressly cancelled. ALARM
LOCK neither assumes, nor authorizes any other
12

person purporting to act on its behalf to modify, to
change, or to assume for it, any other warranty or
liability concerning its products.
In no event shall ALARM LOCK be liable for an
amount in excess of ALARM LOCK's original selling
price of the product, for any loss or damage, whether
direct, indirect, incidental, consequential, or otherwise
arising out of any failure of the product. Seller's
warranty, as hereinabove set forth, shall not be
enlarged, diminished or affected by and no obligation
or liability shall arise or grow out of Seller's rendering
of technical advice or service in connection with
Buyer's order of the goods furnished hereunder.
ALARM LOCK RECOMMENDS THAT THE ENTIRE
SYSTEM BE COMPLETELY TESTED WEEKLY.
Warning: Despite frequent testing, and due to, but
not limited to, any or all of the following; criminal
tampering, electrical or communications disruption, it is
possible for the system to fail to perform as expected.
ALARM LOCK does not represent that the product/
system may not be compromised or circumvented; or
that the product or system will prevent any personal
injury or property loss by burglary, robbery, fire or
otherwise; nor that the product or system will in all
cases provide adequate warning or protection. A
properly installed and maintained alarm may only
reduce risk of burglary, robbery, fire or otherwise but it
is not insurance or a guarantee that these events will
not occur. CONSEQUENTLY, SELLER SHALL HAVE
NO LIABILITY FOR ANY PERSONAL INJURY,
PROPERTY DAMAGE, OR OTHER LOSS BASED
ON A CLAIM THE PRODUCT FAILED TO GIVE
WARNING. Therefore, the installer should in turn
advise the consumer to take any and all precautions
for his or her safety including, but not limited to, fleeing
the premises and calling police or fire department, in
order to mitigate the possibilities of harm and/or
damage.
ALARM LOCK is not an insurer of either the property
or safety of the user's family or employees, and limits
its liability for any loss or damage including incidental
or consequential damages to ALARM LOCK's original
selling price of the product regardless of the cause of
such loss or damage.
Some states do not allow limitations on how long an
implied warranty lasts or do not allow the exclusion or
limitation of incidental or consequential damages, or
differentiate in their treatment of limitations of liability
for ordinary or gross negligence, so the above
limitations or exclusions may not apply to you. This
Warranty gives you specific legal rights and you may
also have other rights which vary from state to state.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2004:02:18 11:44:01-05:00
Modify Date                     : 2004:02:18 11:44:01-05:00
Page Count                      : 12
Creation Date                   : 2004:02:18 16:44:01Z
Mod Date                        : 2004:02:18 16:44:01Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : dblock
Metadata Date                   : 2004:02:18 16:44:01Z
Creator                         : dblock
Title                           : DL2700_OI209A.37_PROG.pub
EXIF Metadata provided by EXIF.tools

Navigation menu