LogiTag Systems STB01 RFID reader of automating reordering operations system User Manual User manual 22570

LogiTag Systems Ltd. RFID reader of automating reordering operations system User manual 22570

user manual

Tel: 972-9-835-4848
Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504
Israel
LogiTag Systems LTD.
www.logi-tag.com
Page
1/11
STOCK BOX USER
MANUAL
Tel: 972-9-835-4848
Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504
Israel
LogiTag Systems LTD.
www.logi-tag.com
Page
2/11
Product
name STOCKBOX™ user manual
p/n Product rev. A01
Document
p/n LT-D-0101 Document
rev. 01
date 14/11/2011 Author name Golan K.
Documents changes and version
Date Name Change description version
14/11/2011 Golan K Document release 01
Tel: 972-9-835-4848
Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504
Israel
LogiTag Systems LTD.
www.logi-tag.com
Page
3/11
1. Safety Instructions / Warning - Read before start-up !
 The device may only be used for the purpose intended by the
manufacturer.
 The operation manual should be kept readily available at all times for
each user.
 Unauthorized changes and the use of spare parts and additional
devices which have not been sold or recommended by the
manufacturer may cause fire, electric shocks or injuries. Such
unauthorized measures shall exclude the manufacturer from any
liability.
 The liability-prescriptions of the manufacturer in the issue valid at the
time of purchase are valid for the device. The manufacturer shall not
be held legally responsible for inaccuracies, errors, or omissions in
the manual or automatically set parameters for a device or for an
incorrect application of a device.
 Repairs may only be undertaken by the manufacturer.
 Installation, operation, and maintenance procedures should only be
carried out by qualified personnel.
 Use of the device and its installation must be in accordance with
national legal requirements and local electrical codes.
 When working on devices the valid safety regulations must be
observed.
Tel: 972-9-835-4848
Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504
Israel
LogiTag Systems LTD.
www.logi-tag.com
Page
4/11
2. System description and operation
The STOCKBOX is a system for automating reordering operations in
healthcare, manufacturing and other environments. By pre-encoding
stock-cards carrying 13.56MHz RFID transponders (ISO-15693) and
placing them in bins at the reordering level, users can perform a
reorder operation by simply placing the card into the StockBox. The
StockBox is designed to identify the cards inserted through its slot, and
send the data to a remote server.
The StockBox supports replenishment monitoring performed by
authorized personnel, by scanning their employee badge and the
individual cards, before they are placed back into the bin.
The StockBox includes an RFID module at operating frequency of
13.56MHz, 0.2W maximum transmitting power.
It has 4 LED as a display and 1 pushbutton.
Tel: 972-9-835-4848
Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504
Israel
LogiTag Systems LTD.
www.logi-tag.com
Page
5/11
The system has 4 interface connectors:
 RJ45 adaptor for Ethernet connection
 D-type 9 pin female connector for RS232 connection
 power supply: plug connector size of 5.5*2.1mm
 SMA female connector for optional GPRS module antenna
2.1 LED Display And Button
Led indicators:
 Power – LED is on when StockBox is connected to power.
 Com – LED is on when Ethernet interface is connected.
 Re-stock button and LED – Pressing the Re-Stock button
will put the StockBox into "Restocking mode" for 1 continues
minute, during which the "Re-Stock Mode" LED will be ON.
 Read – LED is on whenever the system identifies a
transponder either at standard or re-stock mode.
Tel: 972-9-835-4848
Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504
Israel
LogiTag Systems LTD.
www.logi-tag.com
Page
6/11
2.2 Power Supply Connection
 Allowed supply voltage: 12-24V +/-5%.
 System's DC supply connector: male jack size 5.5*2.1mm.
 Use of higher supply voltage can damage the system!!
 Use only authorized class B power supply certified device.
 The current consumption of the device (with GPRS connection)
is 0.3A@12V.
2.3 Ethernet connection
Use CAT5E cable, shielded SFTP.
2.4 RS232 interface
 Standard RS232, port settings:
 baud rate 115200b/s
 data bits=8
 parity=none
 stop bit=1
 flow control=none
 Use standard cable with male D-type 9 pin connector, pin out:
 Pin 2-Tx
 Pin 3-Rx
 Pin 5 – GND
2.5 GPRS antenna connection
In StockBox systems with the optional GPRS module installed,
connect the GPRS antenna supplied with the system and mount it
on the system enclosure or any near-by allowed surface.
2.6 RFID transponders
The system supports ISO15693 transponders.
Tel: 972-9-835-4848
Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504
Israel
LogiTag Systems LTD.
www.logi-tag.com
Page
7/11
2.7 System operation:
To operate the system:
1. Connect power supply to the power plug and see that the Power
LED is ON.
2. Connect LAN or RS232 port to the host computer (section 2.3 and
2.4).
3. Run the StockBox software at the host computer
4. Insert transponders to the slot and see that the "Read" LED is ON
5. Monitor on the host computer's screen the identified transponders
6. Insert only one transponder at a time.
7. To perform Re-Stock operation:
a. Open the StockBox lock and remove all the transponders.
b. Press the Re-stock button,
c. Put your badge on the "IDENTIFY" area on the StockBox
and see that the "Read" LED turns ON.
d. Put the cards taken out of the StockBox on the "Identify"
area one after another. Wait 3 seconds between each
transponder. Each time the Read Led should be on.
Tel: 972-9-835-4848
Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504
Israel
LogiTag Systems LTD.
www.logi-tag.com
Page
8/11
Slot
IDENTIFY
Tel: 972-9-835-4848
Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504
Israel
LogiTag Systems LTD.
www.logi-tag.com
Page
9/11
3. Radio approvals:
Product name: StockBox™
FCC ID: Z97-STB01
Note: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following
measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and
receiver.
-Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician
for help.
Warning:
Changes or modifications to this equipment not expressly approved
by the party responsible for compliance (LogiTag Systems Ltd.) could
void the user’s authority to operate the equipment.
Tel: 972-9-835-4848
Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504
Israel
LogiTag Systems LTD.
www.logi-tag.com
Page
10/11
3.1 EUROPE:
4. System Technical data:
 Mechanical data:
o Dimensions (Wx L x H ) 290*200*180mm
o Weight approx. 3Kg
 Electrical data:
o Supply voltage 12-24V +/-5%
o Power consumption 3.6VA
o RFID transmitting power 0.2W
 Interface:
o Ethernet
o RS232
 Supporting transponders:
o ISO15693
 Temperature range:
o Operation: -20°C to +55°C
o Storage: -20°C to +85°C
o Humidity: 5%-70%
Tel: 972-9-835-4848
Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504
Israel
LogiTag Systems LTD.
www.logi-tag.com
Page
11/11
 Applicable standards:
o RF approval:
o Europe
o USA
o EMC
o Safety

Navigation menu