LongSung Technology U9507A LTE module User Manual U6300

LongSung Technology (Shanghai)Co.,Ltd. LTE module U6300

U9507A USER Manual_R2

U9507A User Manual
Page of 33
Contents
1Introduction ................................................................................................................................................................. 3
1.1 Overview .................................................................................. 3
1.2 Application scenario .......................................................................... 3
2. U9507A interfaces ....................................................................................................................................................... 4
2.1 U9507A interface summary .................................................................... 4
2.1.1 Test points ............................................................................................................................................................... 5
2.1.2 Mini PCIe Interface ................................................................................................................................................ 5
2.1.3 RF interface ............................................................................................................................................................ 8
2.2 U9507A interface application ................................................................... 9
2.2.1 RF antenna interface ............................................................................................................................................. 9
2.2.2 RF Line Routing Design ...................................................................................................................................... 10
2.2.3 Power supply and earth.................................................................................................................................. 13
2.2.4 USB interface ........................................................................................................................................................ 14
2.2.5 USIM interface ...................................................................................................................................................... 16
2.2.6 Audio interface* .................................................................................................................................................... 17
2.2.7 PCM interface* ..................................................................................................................................................... 19
2.2.8 UART interface* .................................................................................................................................................... 20
2.2.9 LED control ........................................................................................................................................................... 21
2.2.10 Others* ................................................................................................................................................................ 22
3. U9507A key features ................................................................................................................................................. 23
3.1 Internet access .............................................................................. 23
3.2 SMS ..................................................................................... 23
3.3 GPS ...................................................................................... 24
3.4 Phonebook ................................................................................ 24
4. Application Illustration ............................................................................................................................................... 24
4.1 Dial-up procedure ........................................................................... 24
4.2 SMS ..................................................................................... 25
4.2.1 Message Format .................................................................................................................................................. 25
4.2.2 Set Message Storage Location .......................................................................................................................... 25
4.2.3 PDU Format .......................................................................................................................................................... 26
4.2.4 TEXT Format ........................................................................................................................................................ 28
4.2.5 SMS Service Center Address Setting ............................................................................................................... 29
4.3 PHONE BOOK ............................................................................ 30
4.3.1 Set Phone Book Storage Location .................................................................................................................... 30
4.3.2 Read Phonebook entries .................................................................................................................................... 30
4.3.3 Write phonebook entry ........................................................................................................................................ 30
4.3.4 Find phonebook entries ....................................................................................................................................... 31
4.4 AUDIO ................................................................................... 31
4.4.1 Originate Call ........................................................................................................................................................ 31
4.4.2 Answer a incoming call ........................................................................................................................................ 31
4.4.3 Disconnect call ..................................................................................................................................................... 31
5. Safety information ...................................................................................................................................................... 31
6 FCC Caution ........................................................................................................................................................... 32
AppendixMechanical dimensions of U9507A ................................................... 32
Page 3 of 33
1Introduction
1.1 Overview
The LONGSUNG U9507A LTE wireless module, powered by Qualcomm MDM9207 chipset, can be integrated into
any devices for 4G mobile applications. It provides phone book, SMSaudio and GPS, as well as high speed internet
access to LTE,HSUPA,HSDPA, UMTS and GSM networks worldwide.
The U9507A module complies with the technical standard listed below:
·LTE
FDD: 150Mbps(DL), 50Mbps(UL)
Support Release 10 category 4
·HSPA+
HSPA+: 42.2Mbps(DL), 5.76Mbps(UL)
·EDGE
3GPP R4, Class 12, up to 236.8 Kbps DL and 118.4Kbps UL
Mobile station class B
·GPRS
3GPP R4, Class 10, Up to 85.6 Kbps DL and 42.8 Kbps UL
The frequency bands supported:
U9507A
LTE-FDD
2/4/5/12/13/17/28
UMTS
2/4/5
GSM
2/5
-”:not support
It working at environment temperature -40~+85℃。
1.2 Application scenario
The LTE U9507A wireless module support phone book, SMS, audio, GPS and Internet access functions. The
application of U9507A is as follows:
Page 4 of 33
Figure1-1 U9507A application scenario
2. U9507A interfaces
2.1 U9507A interface summary
The LTE wireless module U9507A supports for multimode operation: LTE,HSUPA,HSDPA, UMTS and GSM. The
size of U9507A is 50.85×2 9.4.6mm. And the appearance is shown in Figure 2-1 and Figure 2-2.
Figure 2-1 The front view of U9507A Figure 2-2 The rear view of U9507A
Page 5 of 33
The antenna pads are show as part 1in the Figure 2-1, the below one is for the main antenna, and the upper one is
for the diversity antenna; The antenna pad which is shown as part 2 in Figure 2-1 is for GPS application; A miniPCIe
interface is shown as part 3 in Figure 2-1; U9507A module also offers some test points, they are shown as part 4 in
Figure 2-2
2.1.1 Test points
The test points of U9507A are displayed in figure 2-3, and the definition of each point is listed in table 2.1.
Figure 2-3 Test points of U9507A
Table 2.1 The definition of U9507A test points
SN
Definition
1
U9507A Power Input
2
GND
3
USB DATA+
4
USB DATA-
5
GND
6
USIM Card Reset
7
USIM Card Clock
8
USIM Card Data
9
USIM Card Power
2.1.2 Mini PCIe Interface
A Mini PCIe Interface is used, two primary data interfaces are defined for PCI Express Mini Card: PCI Express and
USB. For more information, please refer to the PCI Express®Mini Card Electromechanical Specification Revision 1.1
Figure 2-4 show the Mini PCIe Interface.
Page 6 of 33
Figure 2-4 The Mini PCIe Interface
For protecting the connector from electro-static, it is better to use the ESD element. And the ESD element should be as
close as possible to connector. The definition of the PINs in Mini PCIe Interface is listed in table 2.2 below.
Figure 2-5 The Mini PCIe Interface pin sequence of U9507A
Table 2.2 The definition of Mini PCIe Interface
Page 7 of 33
Definition
Description
Remark
MIC_P*
MIC Data+
Audio Interface
MIC_N*
MIC Data+-
Audio Interface
LINEOUT_P*
Speaker Out+
Audio Interface
LINEOUT_N*
Speaker Out-
Audio Interface
GND
Ground
VOUT*
Power Output
1.8V
NC
NC
NC
GND
Ground
NC
NC
NC
WAKEUP_IN*
Wakeup The Module
Active low
GND
Ground
UART_RXD*
Rx of UART
UART Interface
NC*
NC RTS of UART -
GND
Ground
GND
Ground
UART_TXD*
Tx of UART
UART Interface
RESET*
External Reset to U9507A
GND
Ground
GND
Ground
VBAT
Power Supply
VBAT
Power Supply
GND
Ground
PCM_CLK*
PCM CLK
PCM Interface
PCM_DIN*
PCM Data Input
PCM Interface
PCM_DOUT*
PCM Data Output
PCM Interface
PCM_SYNC*
PCM Synchronization
PCM Interface
VBAT
Power Supply
GND
Ground
NC
NC
NC
Page 8 of 33
USIM_VCC
UIM Power
UIM Interface
UIM_DATA
UIM Data
UIM Interface
UIM_CLK
UIM CLK
UIM Interface
UIM_RESET
UIM Reset
UIM Interface
NC
NC
NC
GND
Ground
W_DISABLE
External Disable signal
Active low signal. This signal is used by the
system to disable radio operation on add-in
cards that implement radio frequency
applications
RESET*
External Reset to U9507A
VBAT
Power Supply
GND
Ground
NC
NC
NC
NC
NC
NC
WAKEUP_OUT*
Wakeup The AP/MCU
GND
Ground
USB_DM
USB Data-
USB Interface
USB_DP
USB Data+
USB Interface
GND
Ground
PWM_OUT
Led control Signal
NC
NC
NC
NC
NC
NC
NC
NC
NC
GND
Ground
VBAT
Power Supply
2.1.3 RF interface
U9507A uses HRSs U.FL-R-SMT-1(10) RF connector on the module side. There are three RF connector on
U9507A,from right to left: main antenna / GPS antenna* / diversity antenna.
The RF connector is showed in figure 2-6.
Page 9 of 33
Figure 2-6 The sketch map of RF connector
2.2 U9507A interface application
U9507A supplies multifold functional interface by a Mini PCIe Interface, such as , USIM card interface, USB interface,
audio interface*, UART interface*, PCMPulse Code Modulation interface*and power supply interface and so on.
The detail information will be given in the follow sections.
2.2.1 RF antenna interface
The impedance of RF antenna is 50Ω.
The three connector is on the top of U9507A;
For minimizing the wasting of RF cable, user should pay more attention to make choice. We suggest choosing the cable
that satisfies:
• GSM900/LTE BAND5/LTE Band2/LTE BAND 4/LTE BAND12/WCDMA
BAND5/WCDMA BAND8<0dB
• DCS1800/LTE Band13/LTE Band17/WCDMA BAND1 <0dB
LTE Band28 <0dB
And the antenna should satisfy the table below
Item
Parameter
Page 10 of 33
Plus(dBi)
GSM
DCS
UMTS
0
0
0
Type
Omni directional antenna
2.2.2 RF Line Routing Design
2.2.2.1 Line Arrangement Examples
Several dedicated tools available to calculate line arrangements for specific applications and PCB materials-for
example from http://www.polarinstruments.com/(commmercial software) or from http://web.awrcorp.com/Usa/
Products/Optional-Products/Tx-Line/(free software).
Embedded Stripline
This figure below shows a line arrangement example for embedded Stripline with 65μm FR4 prepreg(type:1080) and
710μm FR4 core(4-layer PCB).
Figure 2-6 embedded Stripline with 65μm prepreg(1080) and 710μm core
Micro- Stripline
This section gives two line arrangement examples for micro-stripline.
Micro-Stripline on 1.0mm Standard FR42-Layer PCB
The following two figures show examples with differment values for D1(ground strip separation)
Page 11 of 33
Figure 2-7 Micro-Stripline on 1.0mm standard FR4 2-layer PCB-example 1
Figure 2-8 Micro-Stripline on 1.0mm standard FR4 2-layer PCB-example 2
Micro-Stripline on 1.5mm Standard FR4 2-Layer PCB
The following two figures show examples with differment values for D1(ground strip separation)
Page 12 of 33
Figure 2-9 Micro-Stripline on 1.5mm standard FR4 2-layer PCB-example 1
Figure 2-10 Micro-Stripline on 1.5mm standard FR4 2-layer PCB-example 2
2.2.2.2 Routing Example
Interface to RF Connector
Figure 2-11 shows a sample connection of a modules antenna pad at the bottom layer of the module PCB with an
application PCBs coaxial antenna connector .Line impedence depends on line width, but also on other PCB
characteristics like dielectric, height and layer gap. The sample stripline width of 0.33mm is recommended for an
application with a PCB layer stack resembling the one of the PLS62-W evaluation board shown in Figure 12.For
different layer stacks the stripline width will have to be adapted accordingly.
Page 13 of 33
Figure 2-11 Routing to applications RF connector
Figure 2-12 PLS62-W evaluation board layer table
2.2.3 Power supply and earth
The power supply needed by U9507A, is listed as follow:
1. Voltage range DC:3.3V~4.2V , the power for U9507A working;
2. The earth point: GND;
The description of U9507A Power and GND pins is shown in the table 2.3 below.
Table 2.3 The description of U9507A Power and GND pins
Power input
SN. of the Mini PCIe
Interface
VBAT
2, 24, 39, 41,52
GND
4, 9, 15, 18,21, 26, 27, 29, 34,
35, 37, 40, 43, 50
Page 14 of 33
2.2.4 USB interface
2.2.4.1 Description
U9507A offers a high-speed USB interface by Mini PCIe Interface, which submits to USB 2.0 protocol. The detail
information is given in table 2.4 below.
Table 2.4 U9507A USB interface description
Signals offered
by
USB interface
The name of the correlative
pins in
Mini PCIe Interface
SN. of the Mini
PCIe Interface
Description
USB_VBUS
VBAT
2, 24, 39, 41,52
USB power
DM
USB_DM
36
USB Data-
DP
USB_DP
38
USB Data+
GND
GND
4, 9, 15, 18,21, 26, 27,
29, 34, 35, 37, 40, 43,
50
GND
2.2.4.2 Reference circuit
The reference circuit of USB interface is shown in figure 2-7.
1For getting the steady-going USB power supply, it is recommended that a 10uFC406filter capacitor and a 22pF
C407filter capacitor should be used.
2For reducing the BER of USB transmission, it is recommended to add a resistor with values below 10Ω to the
DM and DP in USB interface. Just like the resistors R408 and R409 in figure 2-7.
3For avoiding the electro-static in USB interface, it is recommended to use the ESD element. Just like the voltage
dependent resistors RV406, RV407 and RV408 with the static capacitance values below 3pF.
Page 15 of 33
Figure 2-13 The reference circuit of USB interface
4The USB interface input the voltage from USB_IN .For keeping the USB in U9507A module working unfailingly,
a voltage protection circuit should be added by user between the USB_IN of USB interface and the USB_VBUS PIN of
U9507A. It is shown in figure 2-8 with the red circle 2. In the voltage protection circuit, D603 is a Zener diode with a
breakdown voltage value of 5.1v which could keep the voltage on the USB_VBUS PIN of U9507A not more than
5.1v. D602 is a Schottky Diode, and R621 is a resistor with the value 1KΩ. On the other hand the voltage coming
from the USB_IN also could be converted by using a DC/DC converter to 3.6v and then be sent to VBAT PIN of
U9507A. It is shown in figure 2-8 with the red circle 1.
Figure2-14 The reference of voltage protection circuit
Page 16 of 33
2.2.5 USIM interface
U9507A supports LTE, UMTS and GSM operation mode.. USIM card as well as SIM card can be used.
2.2.5.1 Description
U9507A offers USIM card interface by Mini PCIe Interface. And it can be used in LTE,UMTS and GSM/GPRS/EDGE
networks. The table 2.5 gives the more detail information.
Table 2.5 U9507A USIM card interface description
Signals offered
by
USIM interface
The name of the correlative
pins in
Mini PCIe Interface
SN. of the Mini PCIe
Interface
Description
DATA
UIM_DATA
10
UIM card data
CLK
UIM_CLK
12
UIM card CLK
RST
UIM_RESET
14
Reset signal
VCC
USIM_VCC
8
UIM card power
GND
GND
4, 9, 15, 18,21, 26, 27, 29,
34, 35, 37, 40, 43, 50
GND
2.2.5.2 Reference circuit
The reference circuit of USIM interface is shown in figure 2-9.
1The DATA line of USIM is connected to SIM power by a pull-up resistor, and the reference value is 15KΩ.
2For avoiding the instantaneous voltage overflowing, the resistor with the reference value 22Ω can be used for the
DALA, CLK and RST. Just like the resistors R307, R308 and R309 in figure 2-8.
3For avoiding the electro-static in USIM socket, it is recommended to use the ESD element to the DATACLK and
VCC. Just like the voltage dependent resistors RV301, RV302, RV303 and RV304 in figure 2-8. And the ESD
element should close to the USIM socket as close as possible.
4For getting the more smooth USIM power supply, it is recommended to use the filter capacitors. Just like C311 and
C312 in figure 2-8, and their reference values are 33pF and 100nF.
5In order to remove the unwanted peak signal and the elimination high frequency interference which produces on RST
Page 17 of 33
and CLK, the filter capacities (C310, C309) can be placed in RST and the CLK end, the reference value is 33pF.
Figure 2-15 The reference circuit of USIM interface
2.2.6 Audio interface*
The audio signals here include a pair of input difference signalsMIC1_P, MIC1_Nand a pair of output difference
signals (EAR1OP,EAR1OR. And the Audio interface here includes the earphone jack and the test points.
2.2.6.1 Description
The audio signals offered by U9507A are described in the table 2.7 below.
Table 2.7 U9507A audio signal description
The name of the correlative
pins in
Mini PCIe Interface
SN. of the Mini PCIe
Interface
Description
LINEOUT_P
5
Audio output data+
LINEOUT_N
7
Audio output data-
MIC_P
1
Audio input data+
MIC_N
3
Audio input data-
2.2.6.2 The connection between audio I/O and earphone
The audio I/O signals offered by U9507A can be connected to a stereo earphone jack. The more detail information
Page 18 of 33
about connection between earphone jack and the Mini PCIe Interface is shown in table 2.8 below. And the information
about test points is shown in table 2.1 above.
Table 2.8 The connection between earphone jack and the Mini PCIe Interface
The PIN name of
earphone jack
he name of the correlative pins in
Mini PCIe Interface
SN. of the Mini PCIe
Interface
Description
Left Speaker
LINEOUT_P
5
The left output of stereo
Right Speaker
LINEOUT_N
7
The right output of stereo
MIC
MIC_P
1
The microphone input
PGND
GND
50
Analog ground signal
2.2.6.3 The connection between audio I/O and phone handle
The audio I/O signals offered by U9507A can be connected to a phone handle. The more detail information about
connection between phone handle and the Mini PCIe Interface is shown in table 2.9 below.
Table 2.9 The connection between phone handle and the Mini PCIe Interface
Signals
offered by
phone handle
The name of the correlative
pins in
Mini PCIe Interface
SN. of the Mini PCIe Interface
Description
EAR_P
LINEOUT_P
5
Audio output data+
EAR_N
LINEOUT_N
7
Audio output data-
MIC_P
MIC_P
1
Audio input data+
MIC_N
MIC_N
3
Audio input data-
2.2.6.4 Reference circuit
The reference circuit of audio interface is shown in figure 2-11.
Page 19 of 33
Figure 2-16 The reference circuit of audio interface
1The audio output signals, a pair of difference signal, export to two receivers. And they are not the real traditional
dimensional sound.
2It is recommended to use the smoothing capacitor or smoothing circuit for reducing the undesired signal between
different frequency bands. Just like what is shown in figure 2-9.
3For avoiding the electro-static, it is recommended to use the ESD element. Just like the voltage dependent resistors
RV501, RV502 and RV503 in figure 2-10.
4Designers needs gets up the acoustic train signaling analogous circuit ground terminal and the entire digital circuit
earth end connection, bead or 0 ohm resistance can be used.
5In the chart J501 is a four section of earphone jack schematic diagram electric circuit, you can see audio output
signal connecting difference signal while audio input signal connecting one negative signal.
2.2.7 PCM interface*
U9507A offers Micro the PCM interface and the SPI interface by Mini PCIe Interface. And the SPI interface is
simulated by GPIO PIN.
Page 20 of 33
2.2.7.1 PCM interface description
The information about PCM interface offered by U9507A is described in table 2.10 below.
Table 2.10 U9507A PCM interface description
Signals offered
by PCM
The name of the correlative pins in
Mini PCIe Interface
SN. of the Mini
PCIe Interface
Description
SYNC
PCM_SYNC
51
PCM Synchronous Signal
CLK
PCM_CLK
45
PCM CLK
D ATA_IN
PCM_DIN
47
PCM Input
D ATA_OUT
PCM_DOUT
49
PCM Output
2.2.8 UART interface*
U9507A offers a UART interface (RS232) by Mini PCIe Interface for debugging.
2.2.8.1 Description
The information about UART interface offered by U9507A is described in table 2.12 below.
Table 2.12 U9507A UART interface description
2.2.8.2 Reference circuit
The reference circuit of UART interface is shown in figure 2-12.
1As the UART of U9507A can only supply TTL level while the PC serial port level is the RS232 level, the signal level
between them must use level transformation chip. The reference IC is SP3238EEA which produces by SIPEX, as
Signals offered
by UART
The name of the correlative
pins in
Mini PCIe Interface
SN. of the Mini PCIe
Interface
Description
RX
UART_RXD
23
TX
UART_TXD
31
GND
GND
4, 9, 15, 18,21, 26, 27, 29,
34, 35, 37, 40, 43, 50
Page 21 of 33
shown in Figure 2-11. J401 is a 9 needle serial port plugswe can use it to connect U9507A and PC.
2For avoiding the electro-static, it is recommended to use the ESD element to the signal line of the UART socket. Just
like the voltage dependent resistors RV401, RV402, RV403, RV404 and RV405 in figure 2-11.And the ESD
element should close to the socket as close as possible.
Figure 2-17 The reference circuit of UART interface
2.2.9 LED control
2.2.9.1 Description
There is a pins for LED control in the Mini PCIe Interface. And the detail information is given in table 2.13 below.
Table 2.13 U9507A LED control description
And the U9507A status displayed by LEDs is listed in table 2.14 below.
Table 2.14 LED display description
LED
Status
Description
Green
Flicker quickly (100ms On/800ms Off)
Networks searching
The name of the
correlative pins in
Mini PCIe Interface
SN. of the Mini PCIe
Interface
Description
PWM_OUT
42
Led control Signal
Page 22 of 33
Flicker slowly(100ms On/3000ms Off)
Registered in 3G networks
Always On
Connected to 3G networks, but no data transmitting
Off
Closed or error(No SIM card or failed in registering
networks )
2.2.9.2 Reference circuit
The reference circuit for LED is shown in figure 2-13.
Figure 2-18 The reference circuit of LED control
1 The LED control pin connects to the cathode of LED. And the anode of LED connects to the +3.3v power in figure
2-12.
2The value of electrical current must be below than 10mA. And the reference value is 5mA. So the current-limiting
resistor may be used. Just like the resistor R14 in figure 2-12
3The reference circuit given is for the Green LED, and it is the same for the Red one.
2.2.10 Others*
U9507A also offers some other functional interfaces besides those which have been described above.
These signals are listed in table 2.15 below.
Table 2.15 The other signals offered by U9507A
1) U9507A offers a power supply named VREG_MSMP, its value is +1.8V and the Max. value of electric current is
100mA.
2) EXT_RST_N is used for reset the U9507A module. And U9507A will be reseted just by putting the EXT_RST_N
to GND;
For only keeping the SMPL (Sudden momentary power losing) timer while Sudden momentary power losing, a
capacitor can be used inside of battery. And the correlativity between the capacitance and the holding time is listed in
The name of the correlative pins in
Mini PCIe Interface
SN. of the Mini PCIe
Interface
Description
RESET
33, 22
Reset signal for U9507A
VOUT
11
VREG_MSMP Output1.8V
Page 23 of 33
table 2.16.
Table 2.16 the correlativity between the capacitance and the holding time
The capacitance
The Packaging (X5R)
The holding time
1.5uF
0805
0.5
3.3uF
0805
1.0
4.7uF
0805
1.5
6.8uF
1206
2.0
3. U9507A key features
The U9507A module has features such as internet access, SMS, GPS, phone book and audio. The features are described
in following sections. For detail information about AT commands, please make refers to the related documents.
3.1 Internet access
AT commands can be used for selecting network mode, setting the network search mode, setting register mode,
querying network signal strength, setting APN and so on. The related AT commands are listed as follows:
·Network Mode Set: AT+MODODREX=<mode >
·Network Mode Query: AT+MODODREX?
·Network Mode Service Query: AT+MODPRF?
·Network Query: AT+PSRAT
Querying network signal strengthAT+CSQ
·PIN and PUK Remain Times Query: AT+CPNNUM
·APN Set: AT+CGDCONT=1,"IP","CMNET"
·Dial up Access: ATDT*99***1#
·PS DATA CALL Disconnecting: ATH
3.2 SMS
The SMS feature is implemented by AT commands. You can set the service center address, switch message format,
enable/disable receiving message report, delete message, preview message, receive/send message and so on.
Page 24 of 33
The related AT commands are listed as follow:
·New Message Indication: AT+CNMI
·Message Send: AT+CMGS
·Message Preview: AT+CMGPR
·Message Delete: AT+CMGD
·Message format Switch: AT+CMGF
·Service Center Address Set: AT+CSCA
·Receiving Message Report enable/disable: AT+CNMI=2,1,0,1,0
3.3 GPS
GPS functions are only available in the U9507A module. The related AT command as follow:
AT+GPSFIX originate GPS request
AT+GPSCFG configure GPS parameter
3.4 Phonebook
The Phonebook feature is implemented by AT commands. You can set the phonebook storage location, read phone
number, write phone number and delete phone number and so on.
The related AT commands are listed as follow:
AT+CPBS=<storage> set the storage location
AT+CPBR=<index> read phone number
AT+CPBW=[<index>][,<number>[,<type>[,<text>]]] write phone number on the phone.
AT+CPBW=[<index>] delete phone number.
AT+CPBF=<findtext> find the phone number according to the findtext.
4. Application Illustration
4.1 Dial-up procedure
The type “S” means the AT Command sent to U9507A, and the type “R” means Respond from U9507A.
SN.
Type
AT Command/Respond
Explain
1
S
AT+CPIN?
SIM card querying
2
R
READY
3
S
AT+CPNNUM
PIN And PUK querying
Page 25 of 33
4
R
PIN1=3; PUK1=10; PIN2=0; PUK2=8
5
S
ATD10086
Doing cs call
6
R
AT+CHUP
Hung up the cs call
7
S
AT+CIMI
Get IMSI
8
R
460020177608847
IMSI, by which APN is selected
9
S
AT+CGDCONT=1,"IP","CMNET"
Set APN
10
R
OK
11
S
ATDT*99***1#
Dial-up
12
S
ATH
Disconnect the PS call
4.2 SMS
4.2.1 Message Format
U9507A supports two kinds of message format, PDU and TEXT which can be set by AT command AT+CMGF,
AT+CMGF=0 means PDU format, and AT+CMGF=1 means TEXT format.
4.2.2 Set Message Storage Location
The command AT+CPMS=<mem1>,<mem2>,<mem3> is used to set message storage location.
<mem1>, <mem2>, <mem3> can be set as SM and ME, SM means SIM cardME means the U9507A module.
<mem1>: The parameter set here means memory storage used as read and delete message function. It can be operated
by the followed AT commands: AT+CMGL, AT+CMGR and AT+CMGD;
<mem2>: The parameter set here means memory storage used as writing and send message function. It can be operated
by the followed AT commands: AT+CMSS and AT+CMGW;
<mem3>: Received messages will be storage in this memory if routing to PC is not set;
Response:
If no error:
+CPMS:<used1>,<total1>,<used2>,<total2>,<used3>,<total3>
OK
<used1, 2, 3> Number of messages currently storage in <mem1, 2, 3>
Page 26 of 33
<total1, 2, 3> Number of message capacity of <mem1, 2, 3>
If error:
+CMS ERROR:<err>
The command AT+CPMS? is used to display the remained capacity of memory.
AT+CPMS?
Response:
If no error:
+CPMS:<mem1>,<used1>,<total1>,<mem2>,<used2>,<total2>,<mem3>,<used3>,<total3> OK
If error:
+CMS ERROR
4.2.3 PDU Format
Sending:
The type “S” means the AT Command sent to U9507A, and the type “R” means Respond from U9507A.
SN.
Type
AT Command/Respond
Explain
1
S
AT+CSCS=" UCS2"
Select TE character set
2
R
OK
3
S
AT+CMGF=0
Select message PDU format
4
R
OK
5
S
AT+CMGS=26
0011000D91683198916718F30000000CC8329BFD0
65DDF72363904
<ctrl-Z>
Send message
6
R
+CMGS: 2
OK
Send successfully
Writing message to memory
The type “S” means the AT Command sent to U9507A, and the type “R” means Respond from U9507A.
Page 27 of 33
SN.
Type
AT Command/Respond
Explain
1
S
AT+CMGW=26
0011000D91683198916718F30000000CC8329BFD0
65DDF72363904
<ctrl-Z>
Write a message
2
R
+CMGW: 6
OK
Memory location index 6 of the stored
message is returned.
Receiving message:
+CMTI: "SM",0
Means new received message in the memory located from index 0.
Reading message
The type “S” means the AT Command sent to U9507A, and the type “R” means Respond from U9507A.
SN.
Type
AT Command/Respond
Explain
1
S
AT+CMGR=0
Read message has been received in the
memory location index 0
2
R
+CMGR: 0,,24
0891683108200905F0240D91683198916718F3000
880509111258023047A7A8C03
OK
Read successfully
Deleting message:
The type “S” means the AT Command sent to U9507A, and the type “R” means Respond from U9507A.
SN.
Type
AT Command/Respond
Explain
1
S
AT+CMGD=0
Delete message from preferred memory
location index 0.
2
R
OK
Delete successfully
Page 28 of 33
4.2.4 TEXT Format
Sending:
The type “S” means the AT Command sent to U9507A, and the type “R” means Respond from U9507A..
SN.
Type
AT Command/Respond
Explain
1
S
AT+CSCS=" GSM"
Select TE character set
2
R
OK
3
S
AT+CMGF=1
Select message TXT format
4
R
OK
5
S
AT+CMGS="13572034257"
> 1233455664788666555
<ctrl-Z>
Send message
6
R
+CMGS: 4
OK
Send successfully
Writing message to memory
The type “S” means the AT Command sent to U9507A, and the type “R” means Respond from U9507A..
SN.
Type
AT Command/Respond
Explain
1
S
AT+CMGW="13572034257"
> 11111114
<ctrl-Z>
Write a message
2
R
+CMGW: 8
OK
Memory location index 8 of the stored
message is returned.
Receiving message:
+CMTI: "SM",1
Means new received message in the SIM card located index is 1.
Reading message
The type “S” means the AT Command sent to U9507A, and the type “R” means Respond from U9507A.
Page 29 of 33
SN.
Type
AT Command/Respond
Explain
1
S
AT+CMGR=8
Read message has been received in the
memory location index 8
2
R
+CMGR: 0,,24
+CMGR: "STO UNSENT","13572034257",
11111114
OK
Read successfully
Deleting message:
The type “S” means the AT Command sent to U9507A, and the type “R” means Respond from U9507A. The type “S”
means the AT Command sent to U9507A, and the type “R” means Respond from U9507A.
SN.
Type
AT Command/Respond
Explain
1
S
AT+CMGD=8
Delete message from preferred memory
location index 8.
2
R
OK
Delete successfully
4.2.5 SMS Service Center Address Setting
The user can set the SMS service center address, TP-Validity-Period and SMS Data Coding Mode.
SN.
Type
AT Command/Respond
Explain
1
S
AT+CSCA=”+8613800201500”,145
Set the SMS service center address, and the
address will be kept in SIM card.
2
R
OK
3
S
AT+CSMP=17,167,0,8
Set the TP-Validity-Period as 167 24
hours) ,and the SMS Data Coding Mode as
UCS2
4
R
OK
Remark:
1) TP-MTI supports SMS-DELIVER, SMS-SUBMIT and SMS-STATUS-REPORT, while not support SMS-
DELIVER-REPORT, SMS-SUBMIT-REPORT and SMS-COMMAND.
2) TP-PID is 0 by default while TPDU is sending or saving.
3) The Min. length of <pdu> is 8 and the Max. length of <pdu> is 164 while TPDU is sending or saving,.
Page 30 of 33
4) The parameter <stat> can only be 2 for the command AT+CMGW.
5) In TEXT Format, the parameter <fo> can be 17 and 49, the parameter <pid> can only be 0, the parameter
<dcs> can be 0~31 and the parameter <vp> can be 0~255 for AT+CSMP command
6) In TEXT Format, the parameter <stat> can only be ”STO UNSENT” for the command AT+CMGW
4.3 PHONE BOOK
4.3.1 Set Phone Book Storage Location
Phone book storage location can be set by AT command AT+CPBS. The AT command can be used in three ways.
Performing AT+CPBS? will return the current storage location of the phone book. Such as
+CPBS:<storage>[,<used>,<total>].The parameter <total> indicated how many phone numbers can be stored on the
phone. The parameter <used> indicates how many phone numbers have been stored.
Performing AT+CPBS=? will return all the storage type which the phone supports. Such as +CPBS(list of supported
<storage>s).
We can use AT+CPBS=<storage> to set storage location. There are six types storage location. Its follow as:
LD --store the recently call number which have dialed (SIM).
MC --store the recently call number which havent answered.
RC --store the recently call number which have been answered.
ON -- store the phone number of itself.
“ME” --NVRAM storage
“SM” --SIM storage
4.3.2 Read Phonebook entries
When you want to read phonebook entries, you can use AT command AT+CPBR.
Performing AT+CPBR=? will list of supported index, phone number length and text length.
Performing AT+CPBR=<index1>[,<index2>] will return the content of the phonebook entry of index1. If we use
index1 and index2 at the same time ,it will return all the entries between index1 and index2. Such as
[+CPBR:<index1>,<number>,<type><text>[[...]<CR><LF>+CPBR:<index2>,<number>,<type><text>]]
The parameter <type> include 129 and 145.145 indicate which is a international phone number. 129 indicate which is a
unknown type number.
The parameter <text> is the tag of the number.
4.3.3 Write phonebook entry
When you want to write a phonebook entry on the phone, you can use AT commande AT+CPBW.
Performing AT+CPBW=? will return list of supported index, max length of phone number, list of supported phone
number types and max length of text.
We can use the command AT+CPBW=[<index>][,<number>[,<type>[,<text>]]]” to write number on the phone. If the
parameter <number> is NULL, the command will delete the phone number on the phone of index.
Page 31 of 33
4.3.4 Find phonebook entries
We can use AT command AT+CPBF when we want to find the entry according to the text.
Performing AT+CPBF=? will return the max length of phone number and the max length of text. Such as
+CPBF:[<nlength>],[<tlength>].
When we want to find a entry, we can give the text of the phone number ,and according to the text, we use
AT+CPBF=<findtext> to find the number we want.
4.4 AUDIO
Audio functions are only available in the U9507A module.
4.4.1 Originate Call
ATD<str>[;] Mobile originate call to dial a number. <str>: string of dialing digits, dialing digits:09
<;> only required to set up voice call , return to command state.
The Max length of dialing digits is 20; The prefix ”+” is not counted to the length of dialing digits.
4.4.2 Answer a incoming call
ATA using the command can answer a incoming call.
ATA responds coming call by RING. It will display the calling phone number if CLIP (Calling Line Identity Indication
Presentation) function is set. ATA will return NO CARRIER for responding hang up after connection.
4.4.3 Disconnect call
AT+CHUP using the command can disconnect a connection.
5. Safety information
1. Don't let the product work at extreme low or high temperature -10~55
2. Don’t use more than 4.2 V external power supply.
3. RF exposure hazard warning
This device generates and radiates radio-frequency energy.In order to comply with radio-frequency exposure
guidelines for an uncontrolled environment.
This equipment must be installed and operated while maintaining a minimum body to antenna distance of
20cm.The using antenna should not exceed 0dBi
Page 32 of 33
6FCC Caution
FCC Caution:
(1)Exposure to Radio Frequency Radiation. This equipment must be installed and operated in
accordance with provided instructions and the antenna(s) used for this transmitter must be installe
d
to provide a separation distance of at least 20 cm from all persons and must not be collocated or
operating in conjunction with any other antenna or transmitter. End-users and installers must be
provided with antenna installation instructions and transmitter operating conditions for satisfying R
F
exposure compliance.
(2)Any changes or modifications not expressly approved by the grantee of this device could void th
e
user's authority to operate the equipment.
(3)This Transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
(4)Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user authority to operate the equipment.
(5) the modules FCC ID is not visible when installed in the host, or (6) if the host is marketed so th
at
end users do not have straight forward commonly used methods for access to remove the module s
o
that the FCC ID of the module is visible; then an additional permanent label referring to the enclos
ed
module: Contains Transmitter Module FCC ID: XHZU9507A
AppendixMechanical dimensions of U9507A
The following are Mechanical dimensions of U9507A bottom view, side view and top view. (Unit: mm)
Page 33 of 33
Top View Side View Bottom View