Lopi Leyden Wood Stove Users Manual
Leyden Wood Stove to the manual 9728880e-bde4-4eb0-b722-5c1ceee706ea
2015-02-02
: Lopi Lopi-Leyden-Wood-Stove-Users-Manual-436249 lopi-leyden-wood-stove-users-manual-436249 lopi pdf
Open the PDF directly: View PDF .
Page Count: 38
L e y d e n
Wood Stove
Owner's Manual
• Freestanding Stove
• Mobile-Home Approved
• Alcove Approved
• Hearth-Stove Approved
Save these instructions
for future reference
SAFETY NOTICE:
If this appliance is not properly installed, a house fire may
result. For your safety, follow the installation directions.
Contact local building or fire officials about restrictions and
installation inspection requirements in your area.
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
Copyright 2007, T.I.
$10.00 100-01177
4060802 Listed
Tested to: U.L. 1482
Test Report # 028-S-75-2
2 Introduction
© Travis Industries 100-01177 4060802
Introduction
We welcome you as a new owner of a Leyden wood-burning stove. In purchasing a Leyden you have
joined the growing ranks of concerned individuals whose selection of an energy system reflects both a
concern for the environment and aesthetics. The Leyden is one of the finest appliances the world over.
This manual will explain the installation, operation, and maintenance of this appliance. Please familiarize
yourself with the Owner's Manual before operating your appliance and save the manual for future
reference. Included are helpful hints and suggestions which will make the installation and operation of
your new appliance an easier and more enjoyable experience. We offer our continual support and
guidance to help you achieve the maximum benefit and enjoyment from your appliance.
Important Information
No other Lopi Leyden appliance has the same serial
number as yours. The serial number is stamped onto
the label on the back of the appliance.
This serial number will be needed in case you require
service of any type.
Model: Lopi Leyden
Serial Number:
Purchase Date:
Purchased From:
Register your warranty online at:
traviswarranty.com
Or, mail your warranty card to:
Travis Industries House of Fire
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
Save Your Bill of Sale.
To receive full warranty coverage, you will
need to show evidence of the date you
purchased your heater. Do not mail your Bill
of Sale to us.
We suggest that you attach your Bill of Sale
to this page so that you will have all the
information you need in one place should the
need for service or information occur.
Table of Contents 3
© Travis Industries 100-01177 4060802
General Information
Introduction & Important Information...................... 2
Safety Precautions ............................................ 4
Features & Specifications.................................... 6
Stove Installation
Planning the Installation...................................... 7
Preparation for Installation.............................. 7
Stove Installation Considerations ..................... 7
Floor Protection Requirements ............................. 8
Stove Placement Requirements ........................... 8
Clearances ...................................................... 8
Top View - Straight Installation ........................ 9
Top View - Corner Installation ......................... 9
Bypass Handle Installation .................................. 10
Rear Vent Configuration ..................................... 10
Chimney Connector Requirments ......................... 11
Chimney Requirements ...................................... 12
Chimney Termination Requirements...................... 13
Outside Air Requirements ................................... 13
Alcove Installation Requirements .......................... 14
Mobile Home Requirements ................................ 15
INSTALLATION DIAGRAMS
Standard Ceiling with a Factory Built Chimney.... 16
Cathedral Ceiling with a Factory Built Chimney ... 16
Hearth Stove Positive Connection .................... 17
Hearth Stove Direct Connection....................... 17
Interior or Exterior Masonry Chimney................ 18
Operating Your Appliance
Safety Notice.................................................... 19
Operating the Stove when it is Hot ................... 19
Before Your First Fire ......................................... 19
Curing the Paint ........................................... 19
Over-Firing the Stove .................................... 19
Opening the Doors ............................................ 20
Bypass Operation.............................................. 21
Loading Lid Operation ........................................ 21
Starting a Fire................................................... 22
Adjusting the Burn Rate ...................................... 23
Approximate Air Control Settings ..................... 23
Operating Your Appliance (continued)
Ash Removal.................................................... 24
Ashpan Removal .......................................... 24
Blower Operation .............................................. 25
Re-Loading the Stove......................................... 25
Overnight Burn ................................................. 25
Normal Operating Sounds ................................... 25
Hints for Burning ............................................... 26
Selecting Wood................................................. 26
Why Dry Wood is Key.................................... 26
Wood Cutting and Storage.............................. 26
Troubleshooting ................................................ 27
Maintaining Your Appliance
Daily Maintenance (while stove is in use) ............... 28
Remove Ash (if necessary)............................. 28
Clean the Glass (if necessary)......................... 28
Monthly Maintenance (while appliance is in use) ...... 29
Door and Glass Inspection.............................. 29
Creosote - Formation and Need for Removal...... 29
Yearly Maintenance ........................................... 30
Touch Up Paint ............................................ 30
Cleaning the Air Duct and Blower (if applicable) .. 30
Door Parts ....................................................... 31
Replacing the Glass ...................................... 31
Replacing the Door Gasket............................. 31
Replacing the Loading Lid Gasket.................... 31
Replacing the Door Handle............................. 31
Firebox Parts.................................................... 32
Brick Removal & Replacement ........................ 32
Combustor Removal & Replacement ................ 32
Warranty
Warranty ......................................................... 34
Listing Information
Listing Information ............................................. 35
Optional Equipment
Rear Blower Installation ...................................... 36
Index
Index .............................................................. 38
4 Safety Precautions
© Travis Industries 100-01177 4060802
The viewing door must be
closed and latched during
operation.
Never block free airflow through
the air vents on this appliance.
Gas
Gasoline or other flammable
liquids must never be used to
start the fire or "Freshen Up" the
fire. Do not store or use
gasoline or other flammable
liquids in the vicinity of this
appliance.
This appliance is designed and
approved for the burning of cord
wood only. Do not attempt to
burn any other type of fuel other
than cord wood in this
appliance, it will void all
warranties and safety listings.
ASHES
Ashes must be disposed in a
metal container with a tight lid
and placed on a non-
combustible surface well away
from the home or structure.
Do not touch the appliance while
it is hot and educate all children
of the danger of a high-
temperature appliance. Young
children should be supervised
when they are in the same room
as the appliance.
36"
Keep furniture, drapes, curtains,
wood, paper, and other
combustibles a minimum of 36"
away from the front of the
appliance.
This appliance must be properly
installed to prevent the
possibility of a house fire. The
instructions must be strictly
adhered to. Do not use
makeshift methods or
compromise in the installation.
Ok
Contact your local building
officials to obtain a permit and
information on any installation
restrictions or inspection
requirements in your area.
Notify your insurance company
of this appliance as well.
Inspect the chimney connector
and chimney at least twice
monthly and clean if necessary.
Creosote may build up and
cause a house fire.
Do not connect this appliance to
any chimney serving another
appliance.
Type
HT Clay
Liner
This appliance must be
connected to a listed high
temperature (UL 103 HT)
residential type chimney or an
approved masonry chimney with
a standard clay tile, or stainless
steel liner.
Safety Precautions 5
© Travis Industries 100-01177 4060802
Mobile
Home
When installed in a mobile
home, this appliance must be
bolted to the floor, have outside
air, and not be installed in the
bedroom (Per H.U.D.
requirements). Check with local
building officials.
Do not place clothing or other
flammable items on or near this
appliance.
Never try to repair or replace
any part of this appliance unless
instructions are given in this
manual. All other work must be
done by a trained technician.
Do not make any changes or
modifications to an existing
masonry fireplace or chimney to
install this appliance.
Do not make any changes to the
appliance to increase
combustion air.
Allow the appliance to cool
before carrying out any
maintenance or cleaning. Overfiring the appliance may
cause a house fire. If a unit or
chimney connector glows, you
are overfiring.
Maintain the door and glass seal
and keep them in good
condition.
Avoid placing wood against the
glass when loading. Do not
slam the door or strike the glass.
Do not use a grate or other
device to elevate the fire off of
the firebox floor. Burn the fire
directly on the bricks.
This
Manual
Do not throw this manual away.
This manual has important
operating and maintenance
instructions that you will need at
a later time. Always follow the
instructions in this manual.
Travis Industries, Inc. grants
no warranty, implied or
stated, for the installation or
maintenance of your
appliance, and assumes no
responsibility of any
consequential damage(s).
6 Features & Specifications
© Travis Industries 100-01177 4060802
Installation Options
• Freestanding
• Freestanding in an Alcove
• Freestanding in a Mobile Home
• Freestanding Hearth Stove
Features
• EPA Phase II Approved
• 2.3 Cubic Foot Firebox Volume
• Single Operating Control
• Accepts Logs Up to 21” Long
• Cast Iron Construction
• Heavy Duty Refractory Firebrick
• Optional High-Tech Blower
Heating Specifications
Approximate Maximum Heating Capacity (in square feet)* Up to 2,000
Maximum BTU's per Hour (Cord Wood Calculation) 73,100
Overall Efficiency (Oregon Method) 70 %
Maximum Burn Time Up to 12 Hours
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside
temperature. It is also affected by the quality and moisture level of the fuel.
Dimensions
Weight: 375 Lbs.
NOTE:
Measure side, corner, and back
clearances from the stove top.
2-5/8"
17"
28-3/4"
27-1/4"
6-3/4"
25-1/4"
22-7/8"
Figure 1
Emissions
2.4 Grams Per Hour (EPA Phase II Approved) – Tests conducted by OMNI-Test Laboratories.
Stove Installation (for qualified installers only) 7
© Travis Industries 100-01177 4060802
SAFETY NOTICE:
Please read this entire manual before you install and use your new room heater. Failure
to follow instructions may result in property damage, bodily injury, or even death.
Contact local building or fire officials about restrictions and installation inspection
requirements in your area.
Always use gloves when operating a hot stove. The door handles, loading lid, bypass handle, and other
components become very hot during normal use.
Planning The Installation
We suggest that you have an authorized Travis Industries dealer install your stove. If you install the
stove yourself, your authorized dealer should review your installation plans.
Check with local building officials for any permits required for installation of this stove and notify your
insurance company before proceeding with installation.
Preparation for Installation
• Check for damage to the exterior of the stove.
• Check the interior of the firebox (replace cracked firebrick and make sure baffle is in place).
The stove can be lightened for transportation by removing the doors, loading lid, and firebricks. Replace
these components before operation.
• Install the bypass handle (included in the owner’s pack - see page 10).
Stove Installation Considerations
The table below details the six most common types of installations and the considerations for each type.
Alternative methods of installation are available if they comply with local building codes.
Installation Type Considerations
Standard Ceiling with a Factory Built Chimney
(Page 16)
• Requires ceiling and roof penetration
• Provides best draft
Cathedral Ceiling with a Factory Built Chimney
(Page 16)
• Cathedral style chimney support required
• Provides best draft
Hearth Stove Positive Connection
(Page 17)
• Utilizes existing masonry fireplace (not approved for zero
clearance (metal) fireplaces)
• Provides good draft due to full reline
• Easier to clean than direct or horizontal hearth stove
Hearth Stove Direct Connection
(Page 17)
• Utilizes existing masonry fireplace (not approved for zero
clearance (metal) fireplaces)
• Requires construction of a "block-off plate"
• Draft reduced due to elbows & chimney cross section
Interior Masonry Chimney
(Page 18)
• Utilizes existing masonry chimney (not approved for zero
clearance (metal) fireplaces)
8 Stove Installation (for qualified installers only)
© Travis Industries 100-01177 4060802
Floor Protection Requirements
• Floor protection must extend 6" to the sides and rear of the stove and 16" to the front of the stove
39.25” wide by 44.875" deep - see Figure 2 and Figure 3).
• Floor protection must be non-combustible and at least .018" thick (26 guage).
Stove Placement Requirements
Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or
other means approved by local building or fire officials.
• Stove must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36"
of the front of the stove
• Must maintain the clearances to combustibles listed below (drywall, furniture, etc.):
Clearances
• The following clearances must be met (see Figure 2 and Figure 3)
Minimum Clearance Singlewall
Connector
Singlewall
Connector with
Pipe Shield**
Reduced
Clearance*
A Sidewall to stove 18.00” 18.00” 18.00”
B Backwall to stove 27.25” 17.25” 20.75”
C Cornerwall to stove 19.00” 14.00” 14.00”
D Connector to sidewall 28.75” 28.75” 28.25”
E Connector to backwall 21.00” 11.00” 14.00”
F Connector to cornerwall 23.00” 18.00” 17.50”
*Reduced clearance installations require one of the chimneys and connectors listed below:
AMERI-TEC model DCC connector with AMERI-TEC UL 103 HT chimney
DURAVENT model DVL connector with DURAVENT UL 103 HT chimney
GSW Super Chimney Twenty-One connected directly to appliance
I.C.C. Excel HP connector with I.C.C. UL 103 HT chimney
METALFAB model DW connector with METALFAB UL 103 HT chimney
OLIVER MACLEOD PROVENT model PV connector with OLIVER MACLEOD UL 103 HT chimney
SECURITY model DP connector with SECURITY UL 103 HT chimney
SELKIRK model DSP connector with SELKIRK UL 103 HT chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter
may be required.
NOTE: Mobile Home installations must use the reduced clearance connector and clearances
listed above.
NOTE: Standard residential installations with reduced clearance connector may use the
“Connector to Wall” clearance determined by the connector manufacturer if approved by
local code. This clearance is established by the connector manufacturer and falls under
the connector manufacturer’s listing. “Stove to Wall” clearances must always be met.
** The pipe shield must meet NFPA 211 guidelines (such as the HomeSaver® Stovepipe shield) and
must extend from the flue collar to a location 16” below the ceiling.
Stove Installation (for qualified installers only) 9
© Travis Industries 100-01177 4060802
Top View -
Straight Installation
Measure rear and side clearances from
the nearest edge of the stove top.
Floor Protection
27-1/4”
22-7/8”
16” Min.
Measure front clearances from the
face of the stove (door opening).
6” Min.
6” Min.
Clearance A
NOTE: vent diameter
may vary depending on
brand and model.
Clearance E
Clearance B
Back Wall
Side Wall
2-5/8” Clearance D
Typical Flue Center
Singlewall 24"
Reduced Clearance 17.5"
Singlewall w Pipe Shield 14"
Minimum Flue Center 31-3/4"
3-1/4”
Figure 2
Top View -
Corner Installation
Floor Protection
16” Min.
6” Min.
6” Min.
Measure rear and side clearances from
the nearest edge of the stove top.
Measure front clearances from the
face of the stove (door opening).
NOTE: vent diameter
may vary depending on
brand and model.
Corner Wall
Corner Wall
Clearance C
Clearance F
Typical Flue Center
Singlewall 26"
Reduced Clearance 21"
Singlewall w Pipe Shield 21"
27-1/4”
22-7/8”
2-5/8”
3-1/4”
Figure 3
10 Stove Installation (for qualified installers only)
© Travis Industries 100-01177 4060802
Bypass Handle Installation
See Figure 4 for details on installing the bypass handle.
Line up the set screws on the bypass handle
with the dimples on the bypass shaft. Tighten
with the included 1/8” hex wrench.
1/8" Hex
Figure 4
Rear Vent Configuration
The rear vent configuration is only for masonry fireplace installations (hearth stove). All steel chimney
applications require the top vent configuration.
The vent (chimney connector) may be directed to the rear of the appliance when installed into a masonry
fireplace. See Figure 5 for details.
The flue collar is held in place with three bolts
and two nuts. Use two 7/16" open-end
wrenches to remove the bolts and nuts. 7/16" Wrench
NOTE: Make sure the gasket
underneath the flue collar is properly
located and seals the flue collar when
it is installed.
Open the bypass - this
allows for access to the
nut under the flue collar.
Remove the flue collar and rotate it to the rear.
Use the existing bolts and nuts to attach the
sides of the flue. For the center connection
use the bolt and acorn nut included in the
owner's pack.
Figure 5
Stove Installation (for qualified installers only) 11
© Travis Industries 100-01177 4060802
Chimney Connector Requirements
• Chimney connector is required from the flue collar of the stove to the factory-built chimney (see
Figure 7) or masonry chimney (see Figures 13, 14, and 15).
• The chimney connector must be 6” diameter and a minimum 24 gauge black steel, 26 gauge blued
steel, or one of the reduced-clearance connectors listed on page 8.
NOTE: Aluminum or galvanized steel is not allowed – these materials can not withstand the flue
temperatures and may give off toxic fumes when heated.
NOTE: Standard residential installations may use single-wall connector (Mobile-Homes may not).
• The chimney connector may not pass through a ceiling, attic, roof, closet, or any other concealed
space (use listed UL 103 HT chimney – see “Chimney Requirements for details). DO NOT USE
CONNECTOR PIPE AS CHIMNEY.
• The chimney connector should be as short and direct as possible. No more than 180o of elbows (two
90o elbows, or two 45o & one 90o elbow, etc.) may be used for the entire system (connector and
chimney).. Horizontal runs should slope upwards 1/4” per foot and be a maximum 36” long.
• The chimney connector must be installed with the crimped end pointing downwards (see Figure 7).
This prevents creosote from leaking to the exterior of the pipe.
• The chimney connector must be fastened to the stove and each adjoining section (and chimney).
• In cases where the chimney connector must be passed through a combustible wall or partition, the
following NFPA 211 method may be used if local building codes permit. Check with local authorities
before installation to insure all necessary requirements have been met. Figure 6 details a wall pass-
through based on the NFPA 211 standard.
NFPA 211 Wall Pass-Through
(see NFPA 211 for a full description)
12” Min.
12” Min.
Combustible Materials
Brick
Fire Clay Thimble
Figure 6
12 Stove Installation (for qualified installers only)
© Travis Industries 100-01177 4060802
Chimney Requirements
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• UL 103 HT Chimney must be used from the first ceiling or floor penetration to the chimney cap.
• Use 6" diameter type UL 103 HT chimney from one manufacturer (do not mix brands) or code
approved masonry chimney with a flue liner.
• Chimney must be fastened to each adjoining section.
• Follow the chimney manufacturer's clearances and requirements.
• Use the chimney manufacturer's fire stops, attic guards, roof supports, and flashings when passing
through a ceiling
• No more than 180o of elbows (two 90o elbows, or two 45o & one 90o elbow, etc.) may be used for the
entire system (connector and chimney).
NOTE: Additional elbows may be allowed if draft is sufficient. Whenever elbows are used the draft is
adversely affected. Additional chimney height may be required to boost draft.
Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)
Factory Built
Chimney Sections
Minimum Air Space to
Combustibles (See
Chimney Manufacturer's
Instructions - usually 2")
Floor Penetration Equipment
(Attic Radiation Shield with
Chimney Support)
Roof Penetration Equipment
(Roof Radiation Shield,
Flashing, Storm Collar)
}
}
Floor
Protection
Connector Clearance
(as outlined in this manual)
}
Minimum System 15'
Maximum System 33'
Connector
On singlewall pipe
the crimped end
points downward.
Figure 7
Drafting
Performance
This appliance relies upon natural draft to operate. External forces, such as wind,
barometric pressure, topography, or factors of the home (negative pressure from exhaust
fans, chimneys, air infiltration, etc.), may adversely affect draft. Travis Industries can not be
responsible for external forces leading to less than optimal performance.
Stove Installation (for qualified installers only) 13
© Travis Industries 100-01177 4060802
Chimney Termination Requirements
• Must have an approved cap (to prevent water from entering)
• Must not be located where it will become plugged by snow or other material
• Must terminate at least 3' above the roof and at least 2' above any portion of the roof within 10' (see
Figure 8)
Slanted Roofs
F
lat Roofs
Chimney must
extend 3'
above the roof
Chimney must extend 2'
above any portion of the roof
within 10' of the chimney
Chimney must
extend 3'
above the roof
Chimney must extend 2'
above any portion of the roof
within 10' of the chimney
Figure 8
Outside Air Requirements
• Required for mobile homes and in certain localities (check with building officials)
• Must not be drawn from an enclosed space (garage, unventilated crawl space)
• Requires 3” aluminum duct (do not use plastic “dryer-vent”) and a hose-clamp for securing to the
stove. Maximum 4’ length. NOTE: A 10’ length is allowed if using 4” diameter duct (use a 3” to 4”
converter).
• If using the optional blower, you may need to “ovalize” the duct to route it under the blower box.
3” Air Duct (max. 4’ length)
A screen is required to prevent
rodents from entering.
Outside air entrance must be placed so it
does not become blocked by snow.
Air may be drawn from a ventilated crawl space.
Botttom of Stove
Use a hose clamp to secure the
aluminum air duct to the air inlet
flange on the stove.
Air Duct (3” Dia.)
Figure 9
14 Stove Installation (for qualified installers only)
© Travis Industries 100-01177 4060802
Alcove Installation Requirements
Whenever the stove is placed in a location where the ceiling height is less than 8' tall, it is considered an
alcove installation. Because of the reduced height, the special installation requirements listed below must
be met.
• Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC connector with AMERI-TEC UL 103 HT chimney
DURAVENT model DVL connector with DURAVENT UL 103 HT chimney
GSW Super Chimney Twenty-One connected directly to appliance
I.C.C. Excel HP connector with I.C.C. UL 103 HT chimney
METALFAB model DW connector with METALFAB UL 103 HT chimney
OLIVER MACLEOD PROVENT model PV connector with OLIVER MACLEOD UL 103 HT chimney
SECURITY model DP connector with SECURITY UL 103 HT chimney
SELKIRK model DSP connector with SELKIRK UL 103 HT chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
• The clearances below must be met:
Minimum Clearance
(See Figure 10 below)
Combustible
Alcove
A Sidewall to stove 18.00"
B Backwall to stove 20.75"
D Connector to sidewall 28.25"
E Connector to backwall 14.00"
G Maximum depth of alcove 48.00"
H Minimum width of alcove 63.25"
J Minimum height of alcove 84.00"
a
de
h
j
g
b
Figure 10
Stove Installation (for qualified installers only) 15
© Travis Industries 100-01177 4060802
Mobile Home Requirements
• Outside air must be installed - see "Outside Air Requirements" on page 13
• Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC connector with AMERI-TEC UL 103 HT chimney
DURAVENT model DVL connector with DURAVENT UL 103 HT chimney
GSW Super Chimney Twenty-One connected directly to appliance
I.C.C. Excel HP connector with I.C.C. UL 103 HT chimney
METALFAB model DW connector with METALFAB UL 103 HT chimney
OLIVER MACLEOD PROVENT model PV connector with OLIVER MACLEOD UL 103 HT chimney
SECURITY model DP connector with SECURITY UL 103 HT chimney
SELKIRK model DSP connector with SELKIRK UL 103 HT chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
• Stove placement must maintain the following clearances to combustibles (drywall, furniture, etc.)
A
B
F
C
Measure clearances from the
nearest edge of the stove top.
D
EC
Figure 11
Minimum Clearance
(See the illustration above)
Reduced Clearance
Connector
A Sidewall to stove 18.00”
B Backwall to stove 20.75”
C Cornerwall to stove 14.00”
D Connector to sidewall 28.25”
E Connector to backwall 14.00”
F Connector to cornerwall 17.50”
• If using offsets, use the connector clearance listed in Figure 12,
not the connector manufacturer's clearance.
• The appliance must be secured to the floor (consult your
building official). Secure the outside air boot to the floor and
stove to insure the stove does not dislocate.
• Mobile home installations require a spark arrester at the
chimney termination.
• The appliance must be grounded to the chassis of the mobile
home (consult your building official).
• WARNING:DO NOT INSTALL IN SLEEPING ROOM.
• CAUTION:THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
12” Min.
Connector Clearance
(as outlined above)
Stove Clearance
(as outlined above)
Figure 12
16 Stove Installation (for qualified installers only)
© Travis Industries 100-01177 4060802
Standard Ceiling
with a Factory
Built Chimney
Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)
Chimney Sections
Minimum Air Space to
Combustibles (See
Chimney Manufacturer's
Instructions - usually 2")
Chimney Connector Sections
Follow the chimney
manufacturer's instructions
and clearances for roof
penetrations. A storm collar
and flashing are required
(some require a radiation
shield).
}
}
Minimum 15'
Maximum 33'
Stove Clearances
(See the section "Stove
Placement Requirements"
for more details)
Floor Protection
(See the section "Floor
Protection Requirements"
for more details)
Follow the chimney
manufacturer's instructions
and clearances for floor
penetrations. A ceiling
support is required, an attic
insulation shield is required
where insulation is present.
Insulation
Figure 13
Cathedral Ceiling
with a Factory
Built Chimney
Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)
Chimney Sections
Minimum Air Space to
Combustibles (See Chimney
Manufacturer's Instructions -
usually 2")
Follow the chimney
manufacturer's instructions
and clearances for roof
penetrations. A storm
collar, flashing, and
cathedral-style chimney
support are required
(some require a radiation
shield).
}
Minimum 15'
Maximum 33'
Stove Clearances
(See the section "Stove
Placement Requirements"
for more details)
Floor Protection
(See the section "Floor
Protection Requirements"
for more details)
Chimney
Connector
Sections
Figure 14
Stove Installation (for qualified installers only) 17
© Travis Industries 100-01177 4060802
Hearth Stove
Positive
Connection
NOTE:
Most factory-built
chimney manufacturers
make stainless steel
chimney liners, either
flexible or rigid. This
provides a wide variety
of installation options.
Make sure to follow the
manufacturer's
instructions for
installation and support.
Remove damper
or wire it open
Airtight Insulated
Clean-Out
Min. 36"
Combustible
Mantle
NOTE: The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes
(UBC, etc.). Damage must be
repaired prior to installation. The
chimney must be 15' to 33' tall.
Floor Protection
(See the section
"Floor Protection
Requirements"
for more details)
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
The liner must be
stainless steel connector
or flexible vent. Follow
the liner manufacturer's
instructions for installation
and support.
Cap and flashing
prevents water from
entering
Figure 15
Hearth Stove Direct
Connection
NOTE:
Direct connections require
installation of an airtight,
non-combustible block-off
plate or damper adapter.
Block-off plate or
damper adapter
Remove damper
or wire it open
Airtight
Insulated
Clean-Out
Stainless steel
chimney connector
must Extend 1' past
the block-off plate or
to the flue liner
NOTE: The chimney must have a clay
tile liner. If it does not, the installation
must use a positive connection (full
reline). The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes (UBC,
etc.). Damage must be repaired prior
to installation. The chimney must be
15' to 33' tall.
Clay
Liner
Floor Protection
(See the section "Floor
Protection Requirements"
for more details)
Combustible Mantle
Min. 36"
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
Figure 16
18 Stove Installation (for qualified installers only)
© Travis Industries 100-01177 4060802
Interior or Exterior
Masonry Chimney
NOTE:
This type of installation
requires a UBC approved
masonry connector or
other method approved by
the NFPA 211 standard.
See Chimney Connector
Requirements on page 11
for further details.
Make sure the
clean-out seals in
place.
Clay Liner
See the section "Stove
Placement Requirements" for
minimum clearances required.
Min. 18"
clearance
to ceiling This type of
installation requires
a UBC approved
masonry connector
or other method
approved by the
NFPA 211 standard.
Chimney connector sections
NOTE: The chimney must have a
clay tile liner. If it does not, the
installation must use a positive
connection (full reline). The
entire fireplace and chimney must
be clean, undamaged, and meet
all local building codes (UBC,
etc.). Damage must be repaired
prior to installation. The chimney
must be 15' to 33' tall.
See the section
"Floor Protection
Requirements"
Full Re-Line
(recommended)
Figure 17
Operating Your Appliance 19
© Travis Industries 100-01177 4060802
Safety Notice
If this appliance is not properly installed, a house fire may result. For your safety, follow the installation
directions. Contact local building or fire officials about restrictions and installation inspection
requirements in your area.
Read and follow all of the warnings on pages 4 and 5 of this manual.
Operating the Stove when it is Hot
Always use gloves when operating a hot stove. The door handles, loading lid, bypass handle, and other
components become very hot during normal use.
Before Your First Fire
Verify the Installation
Before starting the stove, verify that the stove is properly installed and all of the requirements in this
manual have been followed.
Keep all flammable materials 36" away from the front of the stove (drapes, furniture, clothing, etc.).
Curing the Paint
This heater uses a heat-activated paint that will emit some fumes while starting
the first fire. Open doors and windows to the room to vent these fumes. This
typically lasts two to four hours. You may also notice oil burning off of the interior
of the heater. This rust-stopping agent will soon dissipate. Furthermore, do
not burn the stove at a high temperature during the first fire. This allows the
cast iron and finish to properly cure.
Door Gasket - The door gasket might adhere to the paint on the front of the
heater. Leave the door slightly ajar for the first fire and be careful when opening
the door after the first fire.
2 to 4 hours
Over-Firing the Stove
This stove was designed to operate at a high temperature. But due to differences in vent configuration,
fuel, and draft, this appliance can be operated at an excessive temperature. If the stove top or other area
starts to glow red, you are over-firing the stove. Shut the air control down to low and allow the stove to
cool before proceeding.
Over-firing may lead to damage of plated surfaces. If you are uncertain of over-firing conditions, we
suggest placing a stove thermometer (e.g. Rutland® Model 710) directly over the door on the stove top -
temperatures exceeding 800° are generally considered over-firing and will void the warranty.
20 Operating Your Appliance
© Travis Industries 100-01177 4060802
Opening the Doors
Typically the doors are only opened to start the fire. Use the Loading Lid to re-load the stove.
Open the bypass first (this prevents
smoke from entering the room).
Open the latch. Swing the
doors open.
WARNING: Do not swing the doors past 90°. This may cause
the doors to strike the body of the stove and cause damage.
NOTE: When closing the doors, close the left door first. Then
shut the right door and tighten the latch.
A door latch tool is included for
operation when the door latch is
hot. Hang the tool on the air
control when not in use.
The door becomes hot during use. Use a glove to open the door if the handle is hot.
To prevent smoke from entering the room, open the bypass before opening the door (see following page
for directions). You can also open the door a small amount and let air enter the firebox.
Operating Your Appliance 21
© Travis Industries 100-01177 4060802
Bypass Operation
The bypass controls the flow of smoke inside the heater. When open, smoke goes directly up the flue,
creating more draft. When closed, the smoke goes through the combustor, utilizing the secondary
combustion system and making the heater more efficient.
• When starting or re-loading the stove, open the bypass.
• Once the stove reaches full temperature – typically 30 minutes, close the bypass.
The bypass handle is located on the left
side. Rotate it to open the bypass.
Bypass CLOSED
Used for normal
operation
Bypass OPEN
Used for starting
and re-loading
If the bypass does not latch in the closed position, you will need to adjust the bypass latch (see page 30).
Loading Lid Operation
Open the lid 1" for a few
seconds to allow air to
enter the firebox.
Open the bypass first (this
helps prevent smoke from
entering the room).
Lift the lid upward.
A log poker is
provided with this
stove. It attaches
with a clip to to the
back of the stove.
WARNING: This part
becomes hot - use gloves.
a
b
Open the air control and allow air to flow
into the firebox for 30 seconds.
cd
Do not wear loose clothing while re-loading the stove. Any item dangling above the opening may ignite.
Carefully close the loading lid after use. Allowing it to “slam” shut may damage the stove.
22 Operating Your Appliance
© Travis Industries 100-01177 4060802
Starting a Fire
Since the dawn of time man has debated the best way to start a fire. Some use the boy-scout "tee-pee",
some prefer the "tic-tac-toe" stack. Either way, review the hints and warnings below to ensure proper fire
starting.
• Make sure the air control and by-pass are pulled out. If additional air is needed, open the doors 1/4"
during the first five minutes of start-up.
Open the bypass. Leave it
open until the stove is
HOT (up to 45 minutes).
Pull the air control
all the way out.
ALLOW THE STOVE TO FULLY HEAT PRIOR TO SHUTTING THE BYPASS
We occasionally get calls regarding a smokey stove during start-up. The primary cause is
shutting the bypass prior to the stove becoming hot. If you shut the bypass too early, the
combustor will not work (the combustor must be hot for it to work properly). This in turn will slow
combustion and will lead to a smokey fire.
Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start
or "freshen up" a fire in this stove. Keep all such liquids well away from the stove while it is in use.
If using a firestarter, use only products specifically designed for stoves - follow the manufacturer's
instructions carefully.
If the smoke does not pass up the chimney, ball up one sheet of newspaper, place it in the center of the
firebox and light it. This should start the chimney drafting (this eliminates "cold air blockage").
Use plenty of kindling to ensure the stove reaches a proper temperature. Once the kindling is burning
rapidly, place a few larger pieces of wood onto the fire.
Starting a “Top-Down Fire”
One particularly successful method for starting a fire is to
stack several large pieces of wood in the center of the stove
(see the illustration to the right). Then place a several wads
of newspaper in the center with kindling on top. When you
light the newspaper this “top-down” fire will burn its way to
the center, igniting the larger pieces. With some practice,
this method should work for you.
Operating Your Appliance 23
© Travis Industries 100-01177 4060802
Adjusting the Burn Rate
Use the air control slider to control the burn rate of the stove. See the illustration below for details.
Low Burn
(air control closed)
High Burn
(air control open)
Use the air control to
change the burn rate.
Approximate Air Control Settings
Overnight Burn Fully in
Medium Burn 1/32" to 5/32” Open
Medium High Burn 5/32” to Fully Open
High Burn Fully Open (Pulled Out)
The air control becomes hot during operation - use gloves or a tool to prevent burns.
The air control may take several minutes to influence the burn rate. When making adjustments, you
may wish to let the stove burn for 10 minutes to gauge performance.
24 Operating Your Appliance
© Travis Industries 100-01177 4060802
Ash Removal
ASHES
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes
should be placed on a noncombustible floor or on the ground, away from all combustible
materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally
dispersed, they should be retained in the closed container until all cinders have thoroughly
cooled.
Ashpan Removal
The ashpan must be properly inserted and fully closed during operation. Failure to fully close and seal
the ashpan may lead to an over-fired stove, negating the warranty and creating a safety hazard.
The ashpan may only be removed after the stove has fully cooled.
Twist the ashpan
handle clockwise.
A handle is provided
on the ashpan to
remove the ashes.
Lift up on the
ashlip and slide
the ashpan
forward.
Operating Your Appliance 25
© Travis Industries 100-01177 4060802
Blower Operation
The blower is available to assist the convection chamber in distributing heat to your home. The directions
below detail the options you have with the blower and the best method for operation.
OFF
Turn the dial all the way counter-
clockwise until it clicks off.
BLOWER
CONTROL
RUN
OFF START
HIGH
The high position is all the way counter-
clockwise, without clicking off.
BLOWER
CONTROL
LOW
Turn the dial all the
way clockwise.
BLOWER
CONTROL
RUN
OFF START
RUN
OFF START
Route the power cord in a location where it will not come in contact with the appliance or become hot.
Re-Loading the Stove
Follow the directions below to minimize smoke spillage while re-loading the stove.
1 Open the air control all the way (pull it out). Open the bypass (rotate it down).
2 Open the loading lid. Let the airflow inside the firebox stabilize before opening the loading lid fully.
3 Load wood onto the fire.
Overnight Burn
This stove is large enough to accommodate burn times up to twelve hours. Follow the steps below to
achieve an overnight burn.
1 Move the air control to high burn and let the stove become hot (burn for approximately 15 minutes).
2 Load as much wood as possible. Use large pieces if possible.
3 Let the stove burn on high for 15 minutes to keep the stove hot, then turn the air control to low.
4 In the morning the stove should still be hot, with embers in the coal bed. Stir the coals and load
small pieces of wood to re-ignite the fire, if desired.
Differences if chimney height and draft may lower overall burn times.
Normal Operating Sounds
Creaks and Clicks:
The steel may creak or click when the stove heats up
and cools down - this is normal.
Blower Sounds:
The optional blower will make a slight "humm"
as it pushes air through the stove.
26 Operating Your Appliance
© Travis Industries 100-01177 4060802
Hints for Burning
• Get the appliance hot before adjusting to low burn
• Use smaller pieces of wood during start-up and high burns to increase temperature
• Use larger pieces of wood for overnight or sustained burns
• Stack the wood tightly together to establish a longer burn
• Leave a bed of ashes (1/2" deep) to allow for longer burns
• Be considerate of neighbors & the environment: burn dry wood only
• Burn small, intense fires instead of large, slow burning fires when possible
• Learn your appliance's operating characteristics to obtain optimum performance
Selecting Wood
• Dry Wood is Key
• Dry wood burns hot, emits less
smoke and creates less creosote.
• Testing Wood Moisture
• Split wood stored in a dry area will
be fully dry within a year. This
insures dry wood. If purchasing
wood for immediate use, test the
wood with a moisture meter. Some
experienced wood burners can
measure wood moisture by
knocking pieces together and
listening for a clear "knock" and not
a "thud".
Wet
Wood
Leads
To
Leads
To
Dry
Wood
Leads
To
Leads
To
Less
Heat More
Heat
More Smoke
and Creostoe Less Smoke
and Creostoe
Why Dry Wood is Key
Wet wood, when burned, must release water stored within the wood. This cools the fire, creates
creosote, and hampers a complete burn. Ask any experienced wood burner and he or she will agree: dry
wood is crucial to good performance.
Wood Cutting and Storage
Cut wood to length and
chop into quarters. Store the wood off the ground in a
covered area. Allow for airflow
around the wood to dry the wood.
Air Flow
Air Flow
Air Flow
Operating Your Appliance 27
© Travis Industries 100-01177 4060802
Troubleshooting
Problem Possible Cause
Smoke Enters Room During
Start-Up
• Open the bypass (pg. 21).
• Open the air control (pg. 23).
• Cold Air Blockage - burn a piece of newspaper to
establish a draft.
• If the flame is not getting enough air, a small crack in
the door is all that is needed.
Kindling Does Not Start - Fire
Smolders
• Open the bypass (pg. 21).
• Open the air control (pg. 23).
• Not enough starter paper - use additional newspaper if
necessary.
• If the flame is not getting enough air, a small crack in
the door is all that is needed.
Smoke Enters Room While Re-
Loading
• Open the bypass before opening the door (pg. 21).
• Open the air control before opening the door (pg. 23).
• Open the loading lid 1 inch and let air enter the firebox
for a few seconds. Once the smoke appears to be
flowing up the chimney consistently, open the loading
lid completely.
• Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases a
small amount of smoke may enter the home. Adding
more pipe or a draft-inducing cap may help.
Stove Does Not Burn Hot Enough • Wood is Wet - see the section "Selecting Wood" on
page 26 for details on wood.
• Make sure the air control is all the way open. Slide the
control back and forth to insure the control is not stuck.
• Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases
the fire may burn slowly. Adding more pipe or a draft-
inducing cap may help.
Blower Does Not Run • Stove is Not Up to Temperature - This is normal. The
blower will come on when the stove is hot - usually 15
to 30 minutes.
• Electricity is Cut to the Blower - Check the household
breaker or fuse to make sure it is operable.
Stove Does Not Burn Long
Enough
• Depending upon wood, draft, and other factors, the
burn time may be shorter then stated. Make sure the
doors are sealing and not allowing air into the firebox -
See the section "Door and Glass Inspection" on page
29 for details.
• Check the ash bed for coals. Often, coals are still
glowing under a slight bed of flyash. By raking these
into a pile you can re-start your stove quickly.
28 Maintaining Your Appliance
© Travis Industries 100-01177 4060802
Failure to properly maintain and inspect your appliance may reduce the performance and life of the
appliance, void your warranty, and create a fire hazard.
Daily Maintenance (while stove is in use)
Remove Ash (if necessary)
• Ash removal is not required once it builds up. 1/2" to 1" of ash may be desirable because it slows the
burn rate. Generally, remove ash once it has built up over 1". Follow the directions below to remove
ash.
1 Let the stove cool completely (at least two hours after the last coal has extinguished).
2 Direct all of the ash through the grill into the ashpan. Remove the ashpan (see page
24). Place the ash into a metal container with a tight fitting lid. The closed container
of ashes should be placed on a noncombustible floor or on the ground, away from all
combustible materials, pending final disposal.
3 You may wish to remove any ash that is deposited in the combustion brick or
combustor (see page 32). This will insure proper combustor operation.
ASHES
Improperly disposed ashes lead to fires. Hot ashes placed in cardboard boxes, dumped in back yards,
or stored in garages, are recipes for disaster.
Wood-burning stoves are inherently dirty. During cleaning have a vacuum ready to catch spilled ash
(make sure ash is entirely extinguished).
There are vacuum cleaners specifically made to remove ash (even if the ash is warm). Contact your
dealer for details.
Clean the Glass (if necessary)
This appliance has an airwash to keep the glass clean. However, burning un-seasoned wood or burning
on lower burn rates leads to dirtier glass (especially on the sides). Clean the glass by following the
directions below.
For Stubborn Creosote:
Dip newspaper or a paper towel in cool
ashes and wipe it on the glass. The ash
acts as a light abrasive.
Allow the stove to fully cool. Apply glass
cleaner or soapy water to the inside of
the glass. Wipe with newspaper or a
paper towel.
The glass will develop a very slight haze over time. This is normal and will not affect viewing of the fire.
Maintaining Your Appliance 29
© Travis Industries 100-01177 4060802
Monthly Maintenance (while appliance is in use)
Make sure the appliance has fully cooled prior to conducting service.
Door and Glass Inspection
The door must form an air-tight seal to the firebox for the stove to work correctly. Inspect the door gasket
to make sure it forms an air-tight seal to the firebox.
The door can be lifted off the hinges if extensive repairs are conducted.
Severely frayed or thread-bare
gasket should be replaced.
Use wood stove gasket
cement to re-adhere
loose gasket.
If the glass is damaged, replace
it - see “Replacement Parts” for
details.
High-Temperature anti-sieze
may be used on the door
hinges to eliminate squeaks.
The door latch should pull the door against the face of the stove (but not so tight as to not allow full
handle rotation). To adjust the door latch, adjust the position of the striker plate that attaches to the front
plate of the stove.
Creosote - Formation and Need for Removal
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled
moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-
burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote
makes an extremely hot fire. The chimney and chimney connector should be inspected at least once
every two months during the heating season to determine if a creosote buildup has occurred. If creosote
has accumulated, it should be removed to reduce the risk of a chimney fire.
If you are not certain of creosote inspection, contact your dealer or local chimney sweep for a full
inspection. Excess creosote buildup may cause a chimney fire, that may result in property damage,
injury, or death.
30 Maintaining Your Appliance
© Travis Industries 100-01177 4060802
Yearly Maintenance
Make sure the appliance has fully cooled prior to conducting service.
Touch Up Paint
Included with the owner's pack of this appliance is a can of Stove-Brite®
paint. To touch up nicks or dulled paint, apply the paint while the appliance is
cool. Sand rusted or damaged areas before preparation (use 120 grit
sandpaper). Clean and dry the area to prepare the surface. Wait at least one
hour before starting the appliance. The touched up area will appear darker
than the surrounding paint until it cures from heat. Curing will give off some
fumes while curing – open windows to ventilate.
Touch-Up
Paint
Cleaning the Air Duct and Blower (if applicable)
Use a vacuum to clean the air ducts (channels). This prevents dust from burning and creating odors.
The optional blower should be vacuumed every year to remove any buildup of dust, lint, etc.
Use a vacuum cleaner to remove any
buildup on the screens of the blower.
BOTTOM OF
STOVE
Adjusting the Bypass Latch
The bypass latch uses a pressure plate to secure it in the closed position. If the bypass does not latch to
the closed position, it may be adjusted following the directions below.
Close the bypass -- you may need
to hold it in the shut position.
Tighten this bolt 1/2 turn. Test operation of the
bypass - opening and closing it several times. If it
does not latch shut, tighten the bolt another 1/2 turn.
NOTE: In rare cases the bolt may be over-tightened,
not allowing the bypass handle to rotate down. in
these cases, loosen the bolt.
Bypass Plate
7/16" Wrench
Verify Cast Iron Fasteners
Verify the fasteners holding the cast iron components are properly tightened.
Maintaining Your Appliance 31
© Travis Industries 100-01177 4060802
Door Parts
5
9
8
10
4
3
7
2
6
1
ID # Description Qty Part # ID # Description Qty Part #
1Door, Left 1 2 Door, Right 1
3 Door Gasket 1 4 Gasket Cement 1
5 Glass Gasket 1 6 Glass 2
7Glass Clip w Screws, Gasket 4 8 Door Hinge w Pins 4
9 Left Door Handle w Hardware 1 10 Right Door Handle w Hardware 1
Replacing the Glass
The glass must not contact the door retainer or glass clips directly. The glass gasket and glass clip
gaskets insulate the glass to prevent cracking. Do not over-tighten the glass clips.
Replacing the Door Gasket
The door gasket inserts into the outer groove of the door. Stove gasket cement holds it in place. Before
installing, remove any residual cement. Lay the gasket in place (start at the lower left corner) and cut off
any excess gasket (do not stretch the gasket. The cement fully cures with heat from the stove. You may
need to open and close the door repeatedly to get the gasket to seat fully.
Replacing the Loading Lid Gasket
The loading lid gasket inserts into the groove below the loading lid. Stove gasket cement holds it in
place. Before installing, remove any residual cement. Lay the gasket in place (start at the back left
corner) and cut off any excess gasket (do not stretch the gasket. The cement fully cures with heat from
the stove. You may need to open and close the lid repeatedly to get the gasket to seat fully.
Replacing the Door Handle
See the illustration above for a component list (see pg. 29 for details on adjusting the door).
32 Maintaining Your Appliance
© Travis Industries 100-01177 4060802
Firebox Parts
4
2
1
1
7
9
6
3
5
8
7
ID # Description Qty Part # ID # Description Qty Part #
1 Side Brick 2 250-00139 2 Combustion Brick 1 250-00141
3 Interram Gasket 1 250-00294 4 Back Brick 1 250-00140
5 Firebox Back 1 6 Combustor 1 250-00247
7 Brick Clips with Bolts 1 250-00144 8 Combustion Brick Gasket 1
9 Firebox Back Screw 4 3
Brick Removal & Replacement
Do not pry brick - they chip and crack easily. Remove the clips holding the side brick in place.
Remove the side brick. Remove the clip holding the back brick in place. Lift the back brick up and
remove. Remove the gasket on top of the combustion brick. Remove the combustion brick.
Combustor Removal & Replacement
Remove the bricks first. Remove the rear heat shield (the screws holding the firebox back are held in
place with nuts accessible from the back of the stove). Remove the firebox back (use a wrench to secure
the nuts on the back of the stove will un-screwing the 4 screws holding the firebox back in place).
Remove the bypass assembly (two nuts and two bolts hold it in place – take care when removing to
prevent damage). Slide the combustor forward to remove.
Limited 5 Year Warranty 33
© Travis Industries 100-01177 4060802
To register your TRAVIS INDUSTRIES, INC. 5 Year Warranty, complete the enclosed warranty card and mail it
within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd.
SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this appliance (appliance is defined as the
equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original
purchaser from the date of purchase as follows:
Check with your dealer in advance for any costs to you when arranging a warranty call.
Mileage or service charges are not covered by this warranty. This charge can vary from store to store.
Year1 - COVERAGE: PARTS & LABOR
Cast Iron Parts
Warranted against breakage, cracking, or burn through.
Enamel Finish
Warranted against peeling or fading, excluding chipping,
mechanical abrasion, or crazing.
Combustion System
Firebrick, combustor - Warranted against breakage or
deterioration not resulting from physical damage or over-
loading of the wood stove.
Air Control Assembly
Slider Plate, Pressure Plate
Ceramic Glass
Glass (breakage from thermal shock)
Ash Removal System
Ashpan, rollers, grate.
Accessories
Blower
Damper Bypass Assembly
Bypass plate, rod, handle
Door Handles and Latching Mechanism
Door handle, shaft, cam, hardware
Re-Installation Allowance
In cases where heater must be removed from home
for repairs, a partial cost of re-installation is covered
(pre-authorization required)
One-Way Freight Allowance
One-way freight allowance on pre-authorized repair
done at factory is covered.
Cement and Gasketing
Exclusions:Paint
Years 2 & 3 - COVERAGE: PARTS & LABOR
Cast Iron Parts
Warranted against breakage, cracking, or burn through.
Combustion System
Firebrick, combustor - Warranted against breakage or
deterioration not resulting from physical damage or over-
loading of the wood stove.
Air Control Assembly
Slider Plate, Pressure Plate
Ash Removal System
Ashpan, rollers, grate.
Damper Bypass Assembly
Bypass plate, rod, handle
Door Handles and Latching Mechanism
Door handle, shaft, cam, hardware
Re-Installation Allowance
In cases where heater must be removed from home
for repairs, a partial cost of re-installation is covered
(pre-authorization required)
One-Way Freight Allowance
One-way freight allowance on pre-authorized repair
done at factory is covered.
Exclusions:Paint, Enamel Finish, Cement and Gasketing, Ceramic Glass, Accessories,
Years 4 & 5 - COVERAGE: PARTS & LABOR
Air Control Assembly
Slider Plate, Pressure Plate
Ash Removal System
Ashpan, rollers, grate.
Damper Bypass Assembly
Bypass plate, rod, handle
Door Handles and Latching Mechanism
Door handle, shaft, cam, hardware
Exclusions:Paint, Enamel Finish, Cement and Gasketing, Ceramic Glass, Accessories, Re-Installation
Allowance, One-Way Freight Allowance, Cast Iron Parts, Combustion System
Page 1 of 2
34 Limited 5 Year Warranty
© Travis Industries 100-01177 4060802
CONDITIONS & EXCLUSIONS
1. This new appliance must be installed by a qualified installer. It must be installed, operated, and maintained at all times in accordance with
the instructions in the Owner’s Manual. Any alteration, willful abuse, accident, neglect, or misuse of the product shall nullify this warranty.
2. This warranty is nontransferable, and is made to the ORIGINAL purchaser, provided that the purchase was made through an authorized
Travis dealer.
3. Discoloration and some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and,
therefore, not covered under warranty.
4. This warranty does not cover misuse of the stove. Misuse includes over-firing (operation where the connector or stove may glow red) of this
appliance can cause serious damage and will nullify this warranty. Misuse includes use of salt saturated wood, chemically treated wood, or
any fuel not recommended in the manual.
5. Damage to the stove due to improper break-in procedures (see manual for proper break in).
6. The salt air environment of coastal areas or a high humidity environment can be corrosive to the castings. These conditions can be corrosive
and can cause the cast iron to rust. This warranty does not cover any damage caused by a salt air or high humidity environment.
7. Damage to the appliance while it is in transit is not covered by this warranty, but is subject to a claim against the common carrier.
8. The warranty, as outlined within this document, does not apply to the chimney components or other Non-Travis accessories used in
conjunction with the installation of this product. If in doubt as to the extent of this warranty, contact your authorized Travis retailer before
installation.
9. Travis Industries will not be responsible for inadequate performance caused by environmental conditions such as nearby trees, buildings,
roof tops, wind, hills or mountains or negative pressure or other influences from mechanical systems such as furnaces, fans, clothes dryers,
etc.
10. This Warranty is void if:
a. The appliance has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals.
b. The appliance is subject to submersion in water or prolonged periods of dampness or condensation.
c. Any damage to the appliance, combustion chamber, heat exchanger or other components due to water, or weather damage which is
the result of, but not limited to, improper chimney/venting installation.
11. Exclusions to this 5 Year Warranty include: injury, loss of use, damage, failure to function due to accident, negligence, misuse, improper
installation, alteration or adjustment of the manufacturer's settings of components, lack of proper and regular maintenance, damage incurred
while the appliance is in transit, alteration, or act of God.
12. This 5 Year warranty excludes damage caused by normal wear and tear, such as paint discoloration or chipping, worn or torn gasketing,
chipped or cracked firebrick, etc. Also excluded is damage to the appliance caused by abuse, improper installation, modification of the
appliance, or the use of fuel other than that for which the appliance is configured (use cord wood only).
13. Damage to brass or plated surfaces caused by fingerprints, scratches, melted items, or other external sources left on the surfaces from the
use of abrasive cleaners is not covered in this warranty. Damage to the surfaces from over-firing (operation where the steel may glow red) is
not covered in this warranty.
14. TRAVIS INDUSTRIES, INC. is free of liability for any damages caused by the appliance, as well as inconvenience expenses and materials.
Incidental or consequential damages are not covered by this warranty. In some states, the exclusion of incidental or consequential damage
may not apply.
15. This warranty does not cover any loss or damage incurred by the use or removal of any component or apparatus to or from the Travis
appliance without the express written permission of TRAVIS INDUSTRIES, INC. and bearing a TRAVIS INDUSTRIES, INC. label of
approval. This warranty does not cover a stove repaired by someone other than a Travis Industries authorized dealer.
16. Any statement or representation of Travis products and their performance contained in Travis advertising, packaging literature, or printed
material is not part of this 5 year warranty.
17. This warranty is automatically voided if the appliance’s serial number has been removed or altered in any way. If the appliance is used for
commercial purposes, it is excluded from this warranty.
18. No dealer, distributor, or similar person has the authority to represent or warrant Travis products beyond the terms contained within this
warranty. TRAVIS INDUSTRIES, INC. assumes no liability for such warranties or representations.
19. Travis Industries will not cover the cost of the removal or re-installation of hearths, facing, mantels, venting or other components.
20. If for any reason any section of this warranty is declared invalid, the balance of the warranty remains in effect and all other clauses shall
remain in effect.
21. This 5 year warranty is the only warranty supplied by Travis Industries, Inc., the manufacturer of the appliance. All other warranties, whether
express or implied, are hereby expressly disclaimed and purchaser’s recourse is expressly limited to the warranties set forth herein.
IF WARRANTY SERVICE IS NEEDED:
1. If you discover a problem that you believe is covered by this warranty, you MUST REPORT it to your Travis dealer WITHIN 30 DAYS, giving
them proof of purchase, the purchase date, and the model name and serial number.
2. Travis Industries has the option of either repairing or replacing the defective component.
3. If your dealer is unable to repair your appliance’s defect, he may process a warranty claim through TRAVIS INDUSTRIES, INC.,
including the name of the dealership where you purchased the appliance, a copy of your receipt showing the date of the appliance’s
purchase, and the serial number on your appliance. At that time, you may be asked to ship your appliance, freight charges prepaid,
to TRAVIS INDUSTRIES, INC. TRAVIS INDUSTRIES, INC., at its option, will repair or replace, free of charge, your appliance if it is
found to be defective in material or workmanship within the time frame stated within this 5 year warranty. TRAVIS INDUSTRIES,
INC. will return your appliance, freight charges (years 1 to 3) prepaid by TRAVIS INDUSTRIES, INC., to your regional distributor, or
dealership.
4. Check with your dealer in advance for any costs to you when arranging a warranty call. Mileage or service charges are not covered by
this warranty. This charge can vary from store to store.
5. Any appliance or part thereof that is repaired or replaced during the limited warranty period will be warranted under the terms of the
limited warranty for a period not to exceed the remaining term of the original limited warranty or six(6) months, whichever is longer.
Page 2 of 2
Listing Information 35
© Travis Industries 100-01177 4060802
Listing Label
36 Optional Equipment
© Travis Industries 100-01177 4060802
Rear Blower Installation (Part # 99000138)
The rear blower improves heat transfer by pushing heated air through the convection channel. Operating
instructions are described in the section "Blower Operation".
Route the wires on the
outside of the stove, behind
the convection jacket.
d
e
Tuck the thermodisk into place. It
wedges between the rear heat sheild
and the cast iron firebox.
Bend the legs of the
thermodisk bracket to
make it 1-1/2” deep.
1-1/2”
a
3/8" Wrench
g
Plug the blower in. Do not route the power cord under or over the stove or in a
location where it may become damaged.
b
c
Route the wires from the blower through the hole
in the back of the blower housing. Attach these
wires to the thermodisk wires.
Position the blower near the rear of the stove. Tuck all excess wire into the
blower box, making sure it does not contact any moving parts. Make sure when
installing the blower, these wires do not become loose.
Attach the blower to the
stove with the three screws
included with the blower.
f
37 Optional Equipment
© Travis Industries 100-01177 4060802
38 Index
© Travis Industries 100-01177 4060802
Air Control (Adjusting the Burn Rate) .......................23
Alcove Installation Requirements ............................14
Ash Removal......................................................24
Ash Removal......................................................28
Ashpan .............................................................24
Blower Cleaning (if applicable) ...............................30
Blower Installation ...............................................36
Blower Operation ................................................25
Brick Removal & Replacement ...............................32
Burn Rate ..........................................................23
Bypass Operation................................................21
Cathedral Ceiling with a Factory Built Chimney..........16
Chimney Connector Requirments ...........................11
Chimney Requirements ........................................12
Chimney Termination Requirements........................13
Clearances ........................................................8
Combustor Removal & Replacement .......................32
Corner Installation (Top View) ................................9
Creosote - Formation and Need for Removal ............29
Curing the Paint ..................................................19
Daily Maintenance (while stove is in use) .................28
Damper (Bypass Operation) ..................................21
Door and Glass Inspection ....................................29
Door Gasket Replacement ....................................31
Door Handle Replacement ....................................31
Door Parts .........................................................31
Doors (Opening the Doors)....................................20
Features & Specifications......................................6
Firebox Parts......................................................32
First Fire............................................................19
Floor Protection Requirements ...............................8
Glass Cleaning ...................................................28
Glass Replacement .............................................31
Hearth (Floor Protection Requirements) ...................8
Hearth Stove Direct Connection .............................17
Hearth Stove Positive Connection .......................... 17
Hints for Burning................................................. 26
Interior or Exterior Masonry Chimney ...................... 18
Introduction & Important Information ....................... 2
Listing Information .............................................. 35
Loading (Re-Loading the Stove) ............................ 25
Loading Lid Gasket Replacement........................... 31
Loading Lid Operation ......................................... 21
Mobile Home Requirements.................................. 15
Monthly Maintenance (while appliance is in use) ....... 29
Opening the Doors.............................................. 20
Operating the Stove when it is Hot ......................... 19
Outside Air Requirements..................................... 13
Over-Firing the Stove .......................................... 19
Overnight Burn................................................... 25
Paint (Touch Up Paint)......................................... 30
Paint Smell (Curing the Paint) ............................... 19
Planning the Installation ....................................... 7
Preparation for Installation.................................... 7
Rear Vent Configuration....................................... 10
Safety Label ...................................................... 35
Safety Precautions.............................................. 4
Sounds............................................................. 25
Specifications .................................................... 6
Standard Ceiling with a Factory Built Chimney .......... 16
Starting a Fire .................................................... 22
Stove Installation Considerations ........................... 7
Stove Placement Requirements............................. 8
Top View - Corner Installation ............................... 9
Top View - Straight Installation .............................. 9
Troubleshooting ................................................. 27
Warnings (Safety Precautions) .............................. 4
Warranty........................................................... 34
Wood (Selecting Wood) ....................................... 26
Yearly Maintenance ............................................ 30