Fire Detection Control Panel BC016-1 • For application in small and mid-sized systems • Addressable conventional technology with up to 16 detector zones • Menu-driven operation • Free parameter setup via PC software or operating field • Factory settings allow for easy commissioning • EN 54/VdS-certified Fire is a permanent threat to life and property. Therefore, immediate response to a fire is imperative. The main objective of the fire detection control panel Series BC016 is to alarm and to react in time and, consequently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca- ted within LST premises, thus guaranteeing flexible and reliable individual solutions. Using a powerful processor system, display texts, and a large number of integrated functions, the fire detection control panels Series BC016 ensure topmost efficiency and speed – prerequisites for saving lives and minimizing damage to property. Description Already in the basic version the fire detection control panel BC016-1 is equipped with eight detector lines in conventional technology and, owing to its sophisticated factory settings, is immediately ready for operation. This allows for quick and efficient application of the product. The control panel can be expanded from 8 to 16 detector zones by means of the Detector Zone Extension MGE8-1. The addressable conventional technology allows for the connection of automatic and non-automatic fire detectors as well as special detectors with contact output. Unambiguous identification of the activated detector in the event of an alarm facilitates the indication of the detector number on the control panel‘s display. Auxiliary outputs whose parameters can be freely set allow also for the realization and clear display of challenging tasks in the field of fire alarm technology. In addition, one slot each is available for a Fire Brigade Interface and for a Serial Interface Module, respectively. The Fire Brigade Interface FWI016-1 allows for the connection of country-specific standardized fire brigade control units or for the expansion of the control panel with additional inputs and outputs for general control tasks. Via the Serial Interface Module SIM216-1 you can address either a PC for the efficient and clearly laid out parameterisation of the fire detection control panel, or a printer. The Serial Interface Module SIM016-3 serves for the connection of INFO-bus devices such as fire brigade control units, remote display and operating panels, remote indication units, etc. Building Safety. Building Security. © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27 OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED A BC016-1_DBL_LST_EN_0804.PDF • PAGE 1 Clear Concept The fire detection control panel BC016-1 has been desi- • The processor-monitored power supply ensures pergned for use in small and mid-sized systems and alreamanent surveillance and charging of the batteries. dy in its basic version provides the following features: This way, even during a power failure the untroubled and uninterrupted operation (for more than 72 hours • 8 conventional detector lines permit the connection depending on the design) is guaranteed. of automatic detectors and manual call points in con- • Three hierarchized authorization levels for operation ventional technology as well as special detectors with and parameterisation facilitate a high degree of secucontact output. Individual detector identification can rity against unauthorized access. be achieved by means of an optional address modu- • The control panel is easily operated menu-driven via le. the display and operating field. Clear instructions on • A slot for connecting the Detector Zone Extension the display guide the user during commissioning, MGE8-1 is available for the extension to 16 conventioperation and maintenance. onal detector lines. • The parameter data can be entered either via the • Dry relay outputs indicate the alarm and fault condidisplay and operating field or, in a more comfortable tions on the control panel. In addition, 16 open-collway, created by means of the PC software PARSOFT-1 ector outputs, two auxiliary inputs, and an additional and loaded into the control panel. Thus, a quick and relay output are available for general applications. efficient transfer of the system configuration into the • The optional Fire Brigade Interface FWI016-1 allows control panel is guaranteed. for the connection of two independent transmitting • After activation, the control panel is immediately readevices for a direct interconnection to a designated dy for operation due to the practical factory setting. alarm respondent (e.g., the fire brigade) as well as This guarantees easy and time-saving commissiofor the connection of a country-specific fire brigade ning. control unit. • Outputs with open parameters and logical combina- The extremely flat wall mount cabinet allows for an easy tions of detector zones for the activation of external mounting in virtually any place of the building. Thanks to controls and alarming devices allow for a maximum its modern, ageless design, architectural requirements of flexibility. Thus, no additional expenses arise for and demands of the respective regulations are ideally external relays, logic gates or timers. Thanks to the combined. The compact design allows for the accomwide range of parameterisation possibilities, individu- modation of the optional Detector Zone Extension, the al requirements even under the most difficult ambient Fire Brigade Interface, the Serial Interface Module, up conditions can be combined into a reasonable fire to 3 auxiliary modules (e.g., relay module, siren connecprotection strategy. tion module) and batteries up to 22Ah apart from the • The LC text display shows all present events with central processing board in the standard case. Series date and time. This allows for quick and targeted BC016 thus stands for modularity and easy expansion. reaction in the event of a fire as well as for easy maintenance. This product complies with all relevant standards of • An event memory allows for the display of the latest EN 54 and is VdS-certified. In addition, the product also 200 events at any time, including all required informa- holds several country-specific approvals and certification. Thus, all system conditions and user operations tes. LST‘s high quality level is secured by a permanentthat occurred are documented in a clearly laid out ly monitored quality management system certified by way. ISO 9001. • A possible breakdown of the central processing board is securely detected and displayed by the system. Building Safety. Building Security. © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27 OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED A BC016-1_DBL_LST_EN_0804.PDF • PAGE 2 Permanent Connection A variety of peripheral devices can be connected to the fire detection control panel BC016-1: • Fire brigade key safe • Fire brigade control unit • Acoustic and optical signaling devices • External protocol printer • Remote indication unit • Actuations • Modules for remote parameterisation and remote maintenance via computer newtork, modem or GSM connection – and much more. Specifications Mains voltage 230VAC +10/-15%, 50Hz Output/nominal voltage typ. 28VDC Output peak current max. 1.8A Own current consumption at 24V typ. 70mA (without optional componentries) Ambient temperature -5°C to +50°C Relative humidity 95% (no condensation) Dimensions W × H × D 380 × 480 × 83 (mm) Colour gray-white, RAL 9002 Weight without accumulator approx. 5kg Approvals (EN 54-2, EN 54-4) VdS G205023 FT 14/439/04 (Austria), Part No. 210102 Order name Fire Detection Control Panel BC016-1/INT1 Building Safety. Building Security. © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27 OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED A BC016-1_DBL_LST_EN_0804.PDF • PAGE 3
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Page Count : 3 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:3298ffb8-61cd-4561-9d37-e8650ae5bea1 Create Date : 2008:01:11 10:31:59Z Modify Date : 2008:01:21 13:44:20+01:00 Metadata Date : 2008:01:21 13:44:20+01:00 Creator Tool : Adobe InDesign CS (3.0) Version ID : 1 Rendition Class : proof:pdf Derived From Instance ID : 7a2d2528-bf63-11dc-bde4-d072868b6038 Derived From Document ID : adobe:docid:indd:54a16865-9436-11dc-b1b4-feb8761793a9 Derived From Version ID : 1 Document ID : adobe:docid:indd:0f1d19e5-c028-11dc-a6ff-bda98ee9268f Marked : True Format : application/pdf Title : Datenblätter LST Rights : (c) LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH Trapped : False Creator : Adobe InDesign CS (3.0) Producer : Adobe PDF Library 6.0EXIF Metadata provided by EXIF.tools