Lutron Electronics 0031 Lighting Control Transceiver User Manual 044 008a RA 600LM
Lutron Electronics Company Inc Lighting Control Transceiver 044 008a RA 600LM
Users Manual
Step 7 Mount and align dimmers. Attach Claro® or Satin ColorsTM wallplates (purchased separately). Tighten screws until snug. Attach wallplates. Operation Switch Tap on, Tap off Tap Twice Quickly - lights adjust rapidly to full. Press & Hold for 2 Seconds - Activates 10 second fade to off. Dimming Rocker Brighten English Three-Location Installation Continued LEDs Indicate light level; glow softly as night light when light is off. (Not available on Accessory Dimmer.) Align dimmers. Ensure FASSTM switches are fully pushed in. ON ON OFF OFF OFF Turn power ON. ON Step 8 Symptom Possible Cause Light does not turn on. • Front Accessible Service Switch (FASSTM) on the dimmers are switched to the left side. • Light bulb(s) burned out. • Breaker is off or tripped. • Blue wire on Accessory Dimmer not connected to the same color wire as the blue wire on Dimmer. Dimmer keeps turning ON and OFF. Installation Instructions for Multi-Location Control • Black and Red wires on Dimmer are reversed. • Dimmer wired in middle of Accessory Dimmer string - must be on the line or load end of string. • Total wattage is under recommended minimum load. (See Important Note No.5.) FCC Information NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Changes or modifications not expressly approved by Lutron Electronics Co. could void the user's authority to operate this equipment. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT NOTICE: FASS™ - Front Accessible Service Switch - to replace bulb, power may be conveniently removed by pulling FASS switch out on both the Dimmer and any Accessory Dimmers. For any procedure other than routine lamp replacement, power must be disconnected at the main electrical panel. For detailed instructions on programming the system, refer to the RadioRA® Setup Guide that is included with an RF Signal Repeater or the Setup and Installation Guide that is included with a Choronos System Bridge and Timeclock. Technical Assistance If you have questions concerning the installation or operation of this product, call the Lutron Technical Support Center. Please provide exact model number when calling. (800) 523-9466 (U.S.A., Canada, and the Caribbean) Other countries call (610) 282-3800 Fax (610) 282-3090 Visit our web site at www.lutron.com Limited Warranty Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within two years after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO TWO YEARS FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR IMPROPER OR INCORRECT REPAIR, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This product may be covered under one or more of the following U.S. patents:4,835,343; 4,954,768; 5,248,919; 5,399,940; 5,637,930; 5,736,965; 5,798,581; 5,838,226; 5,848,054; 5,905,442; 5,982,103; 6,687,487; DES 353,798; DES 378,814; DES 389,461; DES 389,805; DES 395,037; DES 404,013; DES 422,969; DES 428,855; DES 436,579, DES 439,220 and corresponding foreign patents. U.S. and foreign patents pending. Lutron, Claro, and RadioRA are registered trademarks, and FASS is a trademark of Lutron Electronics Co., Inc. © 2004 Lutron Electronics Co., Inc. Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299, U.S.A. Made and printed in the U.S.A. 6/04 P/N 044-050 Rev. A Incandescent / 120V Halogen / Magnetic Low-Voltage RA-6D, RB-6D RA-10D, RB-10D Accessory Dimmer Please Leave for Occupant RA-AD, RB-AD 120 V 50/60 Hz Before installation read instructions completely. Low-Voltage dimmers only: 14. Use models “RALV/RBLV” with only core and coil Important Notes 1. FASS Front Accessible Service Switch Troubleshooting Light turns ON and Dimmer works, but Accessory Dimmer does not work. P/N 044-050 Dim ® W i re l e s s H o m e L i g h t i n g C o n t ro l 2. 3. 4. 5. Caution: To avoid overheating and possible damage to other equipment, do not use to control receptacles, fluorescent lighting fixtures, motoroperated or transformer-supplied appliances. Install in accordance with all national and local electrical codes. Do not paint dimmers or wallplates. Clean with a soft damp cloth only. Do not use any chemical cleaners. Do not use where total wattage is under recommended minimum load. Installation Contents Minimum Load Chart Type of Load Dimmer Wattage 600W 1000W Incandescent 50 W 50 W Magnetic Low-Voltage 50 VA 100 VA 6. 7. 8. 9. 10. 11. 12. Do not exceed maximum load rating of dimmers. In any 3-way/4-way circuit use only one Dimmer with up to 9 Accessory Dimmers. Dimmer may not work with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™). Operate in ambient temperatures between 0°C (32°F) and 40°C (104°F). Dimmer may feel warm to the touch during normal operation. Recommended wallbox depth: 31/2" deep recommended, 21/2" deep minimum. The range and performance of the RadioRA® System is highly dependent on a variety of complex factors such as: • • • • Distance between system components Geometry of the home Construction of walls separating system components Electrical equipment located near system components 13. Do not mix RadioRA 15. (magnetic) low-voltage transformers. Do not use to control solid-state (electronic) low-voltage transformers. CAUTION: Operating a dimmed low-voltage circuit with all lamps inoperative or removed may result in current flow in excess of normal levels. To avoid possible transformer overheating and premature failure, Lutron strongly recommends the following: • Do not operate dimmed low-voltage circuits without operative lamps in place. • Replace burned-out lamps immediately. • Use transformers with thermal protection or fused primary windings to prevent transformer failure due to excess current. “A”(RA-) and “B” (RB-) products within the same system. “A” products and “B” products are not compatible. ® Single-Location Installation Installing one RadioRA® Dimmer to control light(s) from a single location. Page 2 Two-Location Installation Installing one RadioRA® Dimmer and one Accessory Dimmer to control light(s) from two locations. Page 4 Three-Location Installation Installing one RadioRA® Dimmer and two Accessory Dimmers to control light(s) from three locations. Page 6 Multi-Location Installation For installations beyond Three-Location, call the Lutron Technical Support Center at 1-800-523-9466. Operation Using the RadioRA® Dimmer. Page 8 Important Important Wiring Wiring Information Information Multigang Installations Lutron Claro® and Satin ColorsTM wallplates are available in 1 to 6 gang versions. Purchase Claro® and Satin ColorsTM wallplates separately. When combining dimmers in the same wallbox, remove all inner side sections prior to wiring. Using pliers, bend side sections up and down until they break off. When removing side sections for multigang installations, reduction of the dimmer’s load capacity is required. See table below. Breaking Side Sections No sides removed 1 side removed 2 sides removed RA-6D, RB-6D 600 W/VA 500 W/VA 400 W/VA RA-10D, RB-10D 1000 W/VA 800 W/VA 650 W/VA Model Number Do Not Remove Outside Sections When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connectors. Note: Wire connectors provided are suitable for copper wire only. For aluminum wire, consult an electrician. Twist wire connector tight. Small: Strip insulation 3/8" for 14 AWG wire Strip insulation 1/2" for 16 or 18 AWG wire Use to join one 14 AWG supply wire with one 16 or 18 AWG control wire. Large: Strip insulation 1/2" for 10, 12 or 14 AWG wire Strip insulation 5/8" for 16 or 18 AWG wire Use to join one or two 12 or 14 AWG supply wires with one 10, 12, 14, 16, or 18 AWG control wire. Step 4 Be sure no bare wire is exposed. Large Small Wire the Dimmer. Using the screws (or push-in terminals) on the Dimmer and the wire connector provided: Each Control Has Inside Section Removed Middle Control Has Two Side Sections Removed • Connect the Dimmer black screw (or push-in terminal) to either of the wires removed from the switch. For installations involving more than one dimmer in a wallbox, refer to Multigang Installations above before beginning. Check off Steps as completed. • The Dimmer blue screw and push-in terminal are not needed for a Single Location Installation. OFF OFF OFF ON ON • Connect the Dimmer brass screw (or push-in terminal) to the remaining wire removed from the switch. Wiring Diagram Turn power OFF at circuit breaker or remove fuse. ON Step 2 Brass screw • Connect the Dimmer green ground wire to the green or bare copper ground wire in the wallbox. If there is no ground wire in the wallbox, consult an electrician. Single-Location Installation Step 1 Dimmer Black screw Ground wire (bare copper or green) Dimmer Brass Screw Green wire Blue Screw Hot 120 V 60 Hz Black Screw Green Remove wallplate. Pull switch from wall. Light Fixture(s) Ground Neutral Step 5 Mount and align dimmer. Attach Claro® or Satin ColorsTM wallplate (purchased separately). Attach wallplate. Tighten screws until snug. Align dimmer. Disconnect wires. Step 6 Ensure FASSTM switch is fully pushed in. Turn power ON. ON OFF OFF OFF OR Backwired: Insert screwdriver. Pull out wire. ON Terminal Screws: Turn screw to loosen. ON Step 3 Two-Location Installation Replacing two 3-way switches or an existing dimmer and a 3-way switch. For installations involving more than one dimmer in a wallbox, refer to Multigang Installations on page 2 before beginning. Check off Steps as completed. Turn power OFF at circuit breaker or remove fuse. Step 2 Dimmer Wire the Dimmer. Using the screws (or push-in terminals) on the Dimmer and the wire connector provided: • Connect the Dimmer green ground wire to the green or bare copper ground wire in the wallbox. If there is no ground wire in the wallbox, consult an electrician. Brass screw • Select one of the remaining wires and connect it to the brass screw (or push-in terminal) on the Dimmer. Black screw • Connect the remaining wire (note its color) to the blue screw (or pushin terminal) on the Dimmer. Remove wallplates. Pull switches from wall. Step 6 Green wire Wiring the Accessory Dimmer. Red • Connect the Accessory Dimmer brass screw (or push-in terminal) to the tagged wire. At each switch location, tag the wire that is connected to the different colored screw or screw labeled COMMON (not the green ground screw). Tag Black • Connect the Accessory Dimmer black screw (or push-in terminal) to the remaining wire. Black screw Wiring Diagram Ground (Bare copper or green wire) Step 4 Brass Screw Brass Screw Ground wire (Bare copper or green) Blue Screw Hot Different-colored screw (Common) 120 V 60 Hz Disconnect wires. Terminal screws: Turn screw to loosen. Green wire Accessory Dimmer Blue Screw Tag Brass screw • Connect the Accessory Dimmer blue screw (or push-in terminal) to the same color insulated wire connected to the Dimmer blue screw (or push-in terminal) noted in Step 5. Dimmer Ground wire (Bare copper or green) Tag Accessory Dimmer Blue screw • Connect the Accessory Dimmer green ground wire to the green or bare copper ground wire in the wallbox. Step 3 Blue screw Red Black • Connect the Dimmer black screw (or push-in terminal) to the tagged wire removed from the switch. OFF OFF OFF ON ON ON Step 1 Step 5 Black Screw Ground Backwired: Insert screwdriver. Pull out wire. OR Black Screw Green Green Light Fixture(s) Ground Neutral Step 7 Mount and align dimmers. Attach Claro® or Satin ColorsTM wallplates (purchased separately). Attach wallplates. Tighten screws until snug. Important Wiring Information When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connectors. Note: Wire connectors provided are suitable for copper wire only. For aluminum wire, consult an electrician. Twist wire connector tight. Small: Strip insulation 3/8" for 14 AWG wire Strip insulation 1/2" for 16 or 18 AWG wire Use to join one 14 AWG supply wire with one 16 or 18 AWG control wire. Large: Strip insulation 1/2" for 10, 12 or 14 AWG wire Strip insulation 5/8" for 16 or 18 AWG wire Use to join one or two 12 or 14 AWG supply wires with one 10, 12, 14, 16, or 18 AWG control wire. Be sure no bare wire is exposed. OFF OFF OFF ON ON Large Ensure FASSTM switches are fully pushed in. Turn power ON. ON Step 8 Small Align dimmers. Three-Location Installation Replacing two 3-way switches and a 4-way switch. For installations involving more than one dimmer in a wallbox, refer to Multigang Installations on page 2 before beginning. Check off Steps as completed. ON ON Step 2 OFF OFF OFF Turn power OFF at circuit breaker or remove fuse. ON Step 1 Remove wallplates. Pull switches from wall. Accessory Blue Dimmer screw Step 5 Replace the 4-way switch with an Accessory Dimmer. Using the screws (or push-in terminals) on the Accessory Dimmer and the wire connector provided: Red wires • Connect the Accessory Dimmer green ground wire to the green or bare copper ground wire in the wallbox. If there is no ground wire in the wallbox, consult an electrician. • Connect the Accessory Dimmer blue screw (or push-in terminal) to both of the tagged wires (noting their color) removed from the 4-way switch. • Select one of the remaining wires and connect it to the Accessory Dimmer black screw (or push-in terminal). • Connect the remaining wire to the Accessory Dimmer brass screw. Brass screw Green wire Black screw Tags Ground wire (Bare copper or green) Blue screw Red wire Dimmer Step 3 Step 6 Replace the two 3-way switches. One 3-way switch MUST be replaced with a Dimmer and the other with an Accessory Dimmer. Identify the switches. 4-Way Four screw connections plus a green ground screw. 3-Way Three screw connections plus a green ground screw. Wiring the Dimmer: Note: Screw placement may be different on your switch. COMPLETE THIS STEP BEFORE REMOVING WIRES FROM SWITCH. Same colored screws (or marked IN or OUT) Tag Ground (Bare copper or green wire) Ground (Bare copper or green wire) Different-colored screw (Common) • TAG the insulated wire connected to the different colored screw or screw labeled 'COMMON'. Step 4 Tag • TAG the two same color insulated wires which are connected to opposite colored screws. Disconnect wires. Backwired: Insert screwdriver. Pull out wire. Terminal Screws: Turn screw to loosen. OR Important Wiring Information When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connectors. Note: Wire connectors provided are suitable for copper wire only. For aluminum wire, consult an electrician. Small: Strip insulation 3/8" for 14 AWG wire Strip insulation 1/2" for 16 or 18 AWG wire Use to join one 14 AWG supply wire with one 16 or 18 AWG control wire. Large: Strip insulation 1/2" for 10, 12 or 14 AWG wire Strip insulation 5/8" for 16 or 18 AWG wire Use to join one or two 12 or 14 AWG supply wires with one 10, 12, 14, 16, or 18 AWG control wire. • Connect the Dimmer green ground wire to the green or bare copper ground wire in the wallbox. • Connect the Dimmer black screw (or push-in terminals) to the tagged wire removed from the switch. • Connect the Dimmer blue screw (or push-in terminal) to the same color insulated wire as the Accessory Dimmer blue screw (or push-in terminal) noted in Step 5. • Connect the Dimmer brass screw (or push-in terminal) to the remaining wire. Brass screw Green wire Accessory Dimmer • Connect the Accessory Dimmer green ground wire to the green or bare copper ground wire in the wallbox. • Connect the Accessory Dimmer brass screw (or push-in terminal) to the tagged wire. • Connect the Accessory Dimmer blue screw (or push-in terminal) to the same color insulated wire as the Accessory Dimmer blue screw (or push-in terminal) noted in Step 5. • Connect the Dimmer black screw (or push-in terminal) to the remaining wire. Blue screw Brass screw Green wire Black screw Tag Ground wire (Bare copper or green) Wiring Diagram Dimmer Brass Screw Ground wire (Bare copper or green) Red Wiring the Accessory Dimmer: Twist wire connector tight. Be sure no bare wire is exposed. Tag Black screw Accessory Dimmer Blue Screw Brass Screw Blue Screw Accessory Dimmer Brass Screw Blue Screw Hot 120 V 60 Hz Black Screw Green Ground Black Screw Green Ground Black Screw Green Light Fixture(s) Ground Neutral Large Small Continued on next page
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2004:06:03 08:25:12 Producer : Acrobat Distiller 4.0 for Macintosh Subject : 044-008a RA-600LM Creator : Adobe PageMaker 6.52 Title : 044-008a RA-600LM Author : Modify Date : 2004:06:03 08:25:23-04:00 Page Count : 4EXIF Metadata provided by EXIF.tools