Lutron Electronics 0053 Electronic dimmer/switch with RF communication User Manual

Lutron Electronics Company Inc Electronic dimmer/switch with RF communication

User Manual

Download: Lutron Electronics 0053 Electronic dimmer/switch with RF communication User Manual
Mirror Download [FCC.gov]Lutron Electronics 0053 Electronic dimmer/switch with RF communication User Manual
Document ID972770
Application ID+aBM6bNN94j+toosuWTcEw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize19.43kB (242926 bits)
Date Submitted2008-07-18 00:00:00
Date Available2008-07-18 00:00:00
Creation Date2008-06-24 11:23:05
Producing SoftwareAdobe PDF Library 7.0
Document Lastmod2008-06-24 11:23:25
Document TitleUser Manual
Document CreatorAdobe InDesign CS2 (4.0.5)

StanzaTM
StanzaTM Dimmers
SZ-6D, SZ-6ND
StanzaTM Switch
SZ-6ANS
Installation Instructions
120 V
Please Read Before Installing
Dimmer and
Dimmer with Neutral
Switch
Load Specifications
Control
Load Type
Min.
Load
Max.
Load
Incandescent
50 W
600 W
MLV2
50 W / VA
450 W /
600 VA
SZ-6D
Incandescent
10 W
600 W
MLV2
10 W / VA
450 W /
600 VA
Lighting
10 W / VA
6A
Motor
0.083 A
3A
SZ-6ND
SZ-6ANS3
Notes
1D
 immer Load Type: SZ-6D and
SZ-6ND are designed for use with
permanently installed incandescent,
magnetic low-voltage (MLV), or
tungsten halogen only. Do not
install dimmers to control standard
receptacles or motor-operated
appliances.
2 Low-Voltage Applications: Use
SZ-6D and SZ-6ND with magnetic
(core and coil) low-voltage
transformers only. Not for use with
electronic (solid-state) low-voltage
transformers.
Operation of a low-voltage circuit
with lamps inoperative or removed
may result in transformer overheating
and premature failure. Lutron strongly
recommends the following:
•D
 o not operate low-voltage circuits
without operative lamps in place.
•R
 eplace burned-out lamps as quickly
as possible.
•U
 se transformers that incorporate
thermal protection or fused
transformer primary windings to
prevent transformer failure due to
overcurrent.
3 Switch Load Type: SZ-6ANS is
designed for use with all permanently
installed lighting loads and with motor
loads up to 1/4 HP (5.8 A).
50 / 60 Hz
Important Notes
Multigang Installations
Install in accordance with all local and
national electrical codes.
Caution! These controls
must not be used to control
equipment that is not visible
from every control location.
They must also not be used to control
equipment that could create hazardous
situations such as entrapment if
operated accidentally. Examples of such
equipment which must not be operated
by these controls include (but are not
limited to) industrial doors, microwave
ovens, heating pads, etc. It is the
installer’s responsibility to ensure that
the equipment being controlled is visible
from every control location and that
only suitable equipment is connected to
these controls.
Environment: Ambient operating
temperature: 32 to 104 °F (0 to 40 °C),
0 to 90% humidity, non-condensing.
Indoor use only.
Spacing: If mounting one control above
another, leave at least 4½ in. (114 mm)
vertical space between them.
Faceplates: Use Lutron Stanza
faceplates for best color match and
aesthetic appearance. Do not paint
controls or faceplates.
Cleaning: To clean, wipe with a clean
damp cloth. Do not use any chemical
cleaning solutions.
Wallboxes: Lutron recommends using
3½ in. (89 mm) deep wallboxes for
easier installation. Several controls may
be installed in one multigang wallbox
— see Derating Chart.
RF Device Placement: RF dimmers
and switches must be located within
20 feet (6 m) of an RF signal repeater or
a device configured as a repeater.
Stanza RF dimmers or switches cannot
be controlled by the system until they
are addressed and programmed. They
will work as stand-alone controls only.
In multigang installations, several
controls are grouped horizontally in one
multigang wallbox.
When combining controls in a wallbox,
derating is required.
Control Location for Ganging
Derating Chart
Control
SZ-6D,
SZ-6ND
SZ8ANS
Load Type
End of
Gang
Middle
of Gang
Incandescent
500 W
400 W
MLV
400 W /
500 VA
300 W /
400 VA
Lighting
5A
3.5 A
Motor
3A
3A
Middle of gang
Installation
Caution! Locate and remove
fuse or lock circuit breaker in the
OFF position before proceeding.
Wiring with power ON may result
in personal injury or death.
Short Circuit Check: Check the
installation for short circuits before
installing control(s). With power OFF,
install standard mechanical switch(es)
between hot and load. Restore power.
If lights do not work or a breaker trips,
correct wiring and check again. Install
control(s) only when short is no longer
present. Warranty is void if control is
turned ON with a shorted circuit.
1. T
 urn power OFF at fusebox or circuit
breaker.
2. P
 repare wires. When making
wire connections, follow the
recommended strip lengths and
combinations for the supplied wire
connector.
Note: Wire connectors provided are
suitable for copper wire only.
Wire Connector:
• Strip insulation 3/8 in.
(9.5 mm) for #14 AWG
(1.5 mm2) wire
• Strip insulation 1/2 in.
(12.7 mm) for #16 or 18 AWG (1.0 mm2
or 0.75 mm2) wire
• Use to join one #14 AWG
(1.5 mm2) or #12 AWG
(2.5 mm2) ground wire with one #18
AWG (0.75 mm2)
control ground wire.
Twist wire connector tight. Trim or strip
wallbox wires to the length indicated
by the strip gauge on the back of the
control.
Mounting Diagram
Faceplate
adapter
mounting
screws
FCC Information
Note: This equipment has been tested and found to comply with
the limits for a Class B digital device pursuant to Part 15 of the
FCC rules. Operation is subject to the following: (1) This device
may not cause harmul interference, and (2) this device must
accept any interference received, incouding interference that
may cause undesired operation.
End of gang
Wallbox
Included:
Control
mounting
screws
Control
Wire Connector (1)
Mounting Screws (2)
Faceplate/adapter purchased
separately.
Push-In Terminals:
Insert wires fully. Push-in
terminals are for use with
#14 AWG (1.5 mm2) solid
copper wire only. DO NOT
use stranded or twisted
wire.
OR
Screw Terminals: Tighten
securely to 5 in-lbs (0.55
N•m). Screw terminals are
for use with solid copper
wire only. DO NOT use
stranded or twisted wire.
3. W
 ire controls as follows:
Single location installation: See
Wiring Diagrams 1 and 2.
Power Booster and Interfaces:
When using power boosters or
interfaces, see wiring diagrams
provided with the interface.
4. Push all wires back into the wallbox
and loosely fasten the control to the
wallbox using the control mounting
screws provided. Do not pinch the
wires.
5. Attach Lutron Stanza faceplate
adapter and faceplate.
a. Install faceplate adapter onto front
of control(s).
b. Tighten control mounting screws
until faceplate adapter is flush to
wall (do not over-tighten).
c. Snap faceplate onto faceplate
adapter, and verify that control is
aligned properly.
d. If control(s) is (are) misaligned,
loosen mounting screws
appropriately.
6. Restore power. Check for correct
local operation (see Dimmer
Operation and Switch Operation).
Wiring Diagram 1
Single Location Installation
SZ-6D
Dimmer/Switch
Brass
Hot/Live
Black
120 V
50 / 60 Hz
Green
Troubleshooting Guide
Symptom
Cause and Action
Load is off and there
is no indicator on the
dimmer/switch
Power not present
• Circuit breaker OFF or tripped. Perform short circuit check.
• F ASS is in the OFF position. Move FASS to the ON position by
fully pushing it up.
Lighting
load
Wiring error
• Check wiring to be sure it agrees with installation instructions
and wiring diagrams.
Ground
Neutral
Lamps burned out or not installed
• Replace or install lamps.
Wiring Diagram 2
Single Location Installation with Neutral
SZ-6ND, SZ-6ANS
Dimmer/Switch
Hot/Live
Dioded lamps
• Replace with non-dioded lamps.
Damaged dimmer/switch
• Device may have been damaged by previous overload or
miswire. Replace device.
Brass
Silver
Black
120 V
50 / 60 Hz
Green
Load
Ground
Dimmer / switch indicator is on but load cannot be turned on and/or
cannot be turned off
Wiring error
• Check wiring to be sure it agrees with installation instructions
and wiring diagrams.
Light turns ON and OFF
continuously
Load is less than minimum load requirement
• Make sure the connected load meets the minimum load
requirement for that control. See Load Specifications table.
Neutral
Dimmer Operation (SZ-6D, SZ-6ND)
Dimming Slider
Slide up to brighten; slide down to dim
Load must be on for slider to affect intensity
Indicator light in slider track
Glows softly for easy locating of control
Track ends flash amber to indicate programming/
addressing mode
Improper load type
• Check that the load being dimmed is not non-dimmable. See
Load Specifications table.
Lights don’t switch ON/
OFF from keypad
Switch Operation (SZ-6ANS)
Indicator light in slider track
Glows softly for easy locating of control
Tapswitch
Turns load on and off
FASSTM
Front-accessible service switch (facilitates safe bulb
replacement)
Pull down to remove all electrical power from load
and deactivate switch
Push up to restore power to load and switch
Improper programming
• Check programming in the Stanza software.
Out of RF range
• Ensure device is within 20 feet (6 m) of another device
configured as a repeater.
Tapswitch
Turns load on to slider level and off
FASSTM
Front-accessible service switch (facilitates safe bulb
replacement)
Pull down to remove all electrical power from load
and deactivate dimmer
Push up to restore power to load and dimmer
Damaged dimmer/switch
• Device may have been damaged by previous overload or
miswire. Replace device.
Wiring
• Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams.
Faceplate is warm
Solid-state control dissipation
• Solid-state dimmers and switches internally dissipate about
2% of the total connected load. It is normal for dimmers and
switches to feel warm to the touch during operation.
Control is buzzing or
humming
It is normal for dimmers and switches to emit a slight buzzing or
humming sound.
	Returning the Dimmer/Switch to
Notes
Factory Settings
•R
 eturning to factory settings will clear
1. Triple-tap the tapswitch quickly (within
all programming from the dimmer/
1 second).
switch, and will prevent it from being
controlled over RF from a keypad or
2. Press and hold the tapswitch for 5
control interface.
seconds (until the load flashes) .
 fter being returned to factory defaults,
3. Triple-tap the tapswitch quickly again. • A
the device will need to be re-addressed
as part of a system.
Lamp Replacement
Caution! For any procedure other than routine lamp replacement, power
must be disconnected at the main electrical panel. Working with power
ON may result in personal injury or death.
For routine lamp replacement, remove power from the fixture(s) by pulling down
the FASS switch on the Dimmer / Switch.
Technical support: U
 SA, Canada, Caribbean: 1.800.523.9466
Mexico: +1.888.235.2910
Central/South America: +1.610.282.6701
Warranty: 1-year limited warranty standard. 2-year parts and labor warranty, with
8-year pro-rated parts replacement on commissioned systems.
These products may be covered under one or more of the following U.S. patents: 5,248,919;
5,637,930; 5,838,226; 5,848,054; 5,905,442; 6,687,487; 6,803,728; and corresponding foreign
patents. U.S. and foreign patents pending. Lutron and the sunburst logo are registered
trademarks and FASS and Stanza are trademarks of Lutron Electronics Co., Inc.
© 2008 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc.
Made and print­ed in the U.S.A.
P/N 030-994 Rev. A 6 /08

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1.1-111
Instance ID                     : uuid:43814d8a-9b70-4948-a9a9-2856fe5b424e
Document ID                     : adobe:docid:indd:192b05e9-3237-11dd-b82a-ac4c19f22906
Rendition Class                 : proof:pdf
Derived From Instance ID        : 192b05e8-3237-11dd-b82a-ac4c19f22906
Derived From Document ID        : adobe:docid:indd:c74e7684-3232-11dd-b82a-ac4c19f22906
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 300.00, 300.00, 72.00
Manifest Placed Y Resolution    : 300.00, 300.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:475B50F8A33D11DC9AE4F26D9E047CA8, uuid:2711D17DA33D11DC9AE4F26D9E047CA8, uuid:6081411C76C5DA11BDC9A93607A846D6
Manifest Reference Document ID  : uuid:2711D182A33D11DC9AE4F26D9E047CA8, uuid:2711D17CA33D11DC9AE4F26D9E047CA8, uuid:5F81411C76C5DA11BDC9A93607A846D6
Create Date                     : 2008:06:24 11:23:05-04:00
Modify Date                     : 2008:06:24 11:23:25-04:00
Metadata Date                   : 2008:06:24 11:23:25-04:00
Creator Tool                    : Adobe InDesign CS2 (4.0.5)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 11408 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS2 (4.0.5)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JPZ0053

Navigation menu