Lutron Electronics 0066 Dimmer or Switch User Manual 2

Lutron Electronics Company Inc Dimmer or Switch 2

Contents

User Manual 2

Download: Lutron Electronics 0066 Dimmer or Switch User Manual 2
Mirror Download [FCC.gov]Lutron Electronics 0066 Dimmer or Switch User Manual 2
Document ID1194372
Application IDAqq++bjjRm+P/4n8m/mfug==
Document DescriptionUser Manual 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize28.51kB (356363 bits)
Date Submitted2009-11-04 00:00:00
Date Available2009-11-04 00:00:00
Creation Date2009-08-19 10:50:39
Producing SoftwareAdobe PDF Library 8.0
Document Lastmod2009-10-24 10:41:01
Document TitleUser Manual 2
Document CreatorAdobe InDesign CS3 (5.0.4)

Installation Instructions
Please Read Before Installing
English
Installation
RF Lamp Dimmer
RRD-3LD
1.	Find a suitable location for the RF Lamp Dimmer. Place the RF Lamp
Dimmer in a convenient and accessible location.
120 V
Load Specifications:
Lamp
Dimmer
RRD-3LD
50 / 60 Hz
Troubleshooting Guide
5.	Turn lamp switch ON and operate RF Lamp Dimmer.
Symptom
Probable Cause and Action
Light does not turn ON, but
LEDs on Lamp Dimmer are
ON
Switch on lamp is turned OFF
• Turn lamp switch to full ON.
Lamp Dimmer
Load
Type
Min.
Load
Max.
Load
Incand.
10 W
300 W
MLV
10 W / VA
200 W /
300 VA
2.	Turn lamp OFF and unplug lamp cord from wall outlet.
Dioded lightbulbs
• If dioded lightbulbs are being used,
replace with non-dioded lightbulbs.
Use these instructions to install the
model numbers listed above. For
system setup instructions and tools visit:
www.lutron.com/radiora2
Light does not turn ON, and
LEDs on Lamp Dimmer are
OFF
Circuit breaker is OFF
• Turn circuit breaker ON.
Lamp Dimmer does not dim
properly or lights flicker
Lamp has an integral dimmer
• Use lamp without an integral dimmer.
Important Notes
WARNING: To avoid the risk of entrapment, serious injury, or death, these
controls must not be used to control equipment which is not visible from
every control location or which could create hazardous situations such
as entrapment if operated accidentally. Examples of such equipment
which must not be operated by these controls include (but are not limited
to) motorized gates, garage doors, industrial doors, microwave ovens,
heating pads, etc. It is the installer’s responsibility to ensure that the
equipment being controlled is visible from every control location and that
only suitable equipment is connected to these controls. Failure to do so
could result in serious injury or death.
Local Operation
3.	Plug lamp cord into the RF Lamp Dimmer plug.
Environment: Ambient operating temperature: 32 °F to 104 °F
(0 °C to 40 °C), 0% to 90% humidity, non-condensing. Indoor use only.
4.	Plug RF Lamp Dimmer into any standard wall outlet.
Cleaning: To clean, wipe with a clean damp cloth. Do not use any
chemical cleaning solutions.
Lamp Type: Lamp Dimmers are designed for use with incandescent,
magnetic low-voltage, and tungsten halogen lightbulbs only. Do not use
to control fluorescent lightbulbs or table lamps with an integral dimmer or
touch lamps. For lamps with integral 3-way switches, switch should be set
to full on position. Lamp Dimmers may not work with dioded lightbulbs.
RF Device Placement: RF dimmers, switches, keypads and shades/
drapes must be located within 30 ft (9 m) of an RF signal repeater. For
systems without an RF signal repeater, all RF dimmers, switches, keypads
and shades/drapes must be located within 30 ft (9 m) of each other.
Remote dimmers and switches are not required to be within a specific
range.
Pressing the Tapswitch on the Lamp Dimmer will alternately turn the lights
ON and OFF.
The ON level will be the level previously set using the Dimming Rocker to the
right of the Tapswitch. The LED that is glowing slightly brighter than the others
indicates the level to which the lights will turn ON. Press and hold the top or
bottom of the Dimming Rocker to raise or lower the light level. Double-tapping
the Tapswitch will turn the lights ON to full. Pressing and holding the Tapswitch
for 1/2 second (while ON) activates a 10-second long fade-to-off.
Codes: Install in accordance with all local and national electrical codes.
Low-voltage Applications: Use Lamp Dimmers with magnetic (core
and coil) low-voltage lamps only. Not for use with electronic (solid-state)
low-voltage lamps. Operation of a low-voltage circuit with lightbulbs
inoperative or removed may result in transformer overheating and
premature failure. Lutron strongly recommends the following:
• D
 o not operate low-voltage circuits without operative lightbulbs in
place.
• R
 eplace burned-out lightbulbs as quickly as possible.
• U
 se transformers that incorporate thermal protection or fused
transformer primary windings to prevent transformer failure due to
overcurrent.
Cord is not plugged in
• Plug cord into wall outlet as shown
in Installation.
3-way switch on lamp is not set to full ON
• Turn 3-way switch on lamp to full ON
NOTICE: To avoid overheating and possible damage to other equipment,
do not use to control motor-operated or transformer-supplied appliances or
other non-lighting loads.
Cordset: The cordset length is 6 ft (1.8 m).
Lightbulbs are burned out or not installed
• Replace or install lightbulbs.
Status LEDs
Indicate light level; glow softly as
night light when lamp is off
Tapswitch
Tap on/off; double-tap for full on;
press and hold (while ON) for
10-second long fade-to-off
Dimming Rocker
Press to Brighten
Press to Dim
Lights don’t turn ON / OFF
from Keypad or Integrated
Scene Controller
Improper programming
• Program according to the
RadioRA-SR Setup Guide.
Out of RF range
• Reposition to be within 30 ft (9 m)
of controlling keypads or an Integrated
Scene Controller.
Lamp Dimmer is warm
Solid-state control dissipation
• Solid-state dimmers internally dissipate
about 2% of the total connected load.
It is normal for dimmers to feel warm to
the touch during operation.
Note: Refer to the system Setup Guide for additional troubleshooting suggestions.
Returning Lamp Dimmers to Factory Settings
Note: Returning a Lamp Dimmer to its Factory Settings will remove the Lamp
Dimmer from the system and erase all programming.
1. Triple-tap and hold the tapswitch. DO NOT release after third tap.
2. Continue to hold the tapswitch on the third tap until LEDs start to scroll up and
down quickly (approximately 3 seconds).
3. Release the tapswitch and immediately triple-tap it again. The LEDs will scroll
up and down slowly. When the LEDs stop scrolling, the Lamp Dimmer has been
returned to Factory Settings.
Warranty:
For warranty information, please see the warranty enclosed with
the product, or visit www.lutron.com/resiinfo.
 ARNING: To avoid risk of electrical shock, do not open, cut cord,
or rewire device. Modification of the device can result in personal
injury or death.
These products may be covered under one or more of the following U.S.
patents: 5,248,919; 5,399,940; 5,637,930; 5,838,226; 5,848,054; 5,905,442;
6,687,487; 6,803,728; D439,220 and corresponding foreign patents. U.S. and
foreign patents pending. Lutron, RadioRA and the sunburst logo are registered
trademarks of Lutron Electronics Co., Inc.
©2009 Lutron Electronics Co., Inc.
 ARNING: To avoid risk of electrical shock, unplug Lamp Dimmer
when changing light bulbs. Changing light bulbs with the power on
could result in personal injury or death.
Technical Assistance:
U.S.A. / Canada: 1.800.523.9466
Mexico: +1.888.235.2910
Other Countries: +1.610.282.3800
24 hours a day, 7 days a week.
Note: This is a POLARIZED cord set. It has a polarized plug (one blade
is wider than the other) and outlet (one slot is wider than the other).
The polarized plug is not intended to be mated with nonpolarized outlets
(having both slots the same size).
A polarized outlet is intended to mate with a polarized plug in only one way
(the longer slot with the wider blade).
Lutron Elec­tron­ics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299
Made and print­ed in the U.S.A. 8 / 09 P/N 044-163 Rev. A

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-702
Instance ID                     : uuid:63ee72e2-2000-4d0a-9f6d-de3aaaea4a25
Document ID                     : adobe:docid:indd:6b20a7da-8e3f-11de-8801-b88f63c3802b
Rendition Class                 : proof:pdf
Derived From Instance ID        : 6b20a7d9-8e3f-11de-8801-b88f63c3802b
Derived From Document ID        : adobe:docid:indd:6b20a7d8-8e3f-11de-8801-b88f63c3802b
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:68004B82CC33DD11ACB08D5F57645509, uuid:16D70D6D862EDE11A16E94CDE4FB69BD, uuid:E907F24BDE3BDE11A807D60480892B36, uuid:EA07F24BDE3BDE11A807D60480892B36, uuid:EC07F24BDE3BDE11A807D60480892B36, uuid:ED07F24BDE3BDE11A807D60480892B36, uuid:43DFD4DB1B4911DCA993C25EC2B58FA4
Manifest Reference Document ID  : uuid:66004B82CC33DD11ACB08D5F57645509, uuid:15D70D6D862EDE11A16E94CDE4FB69BD, uuid:837E05D7822EDE11A16E94CDE4FB69BD, uuid:867E05D7822EDE11A16E94CDE4FB69BD, uuid:EB07F24BDE3BDE11A807D60480892B36, uuid:8C7E05D7822EDE11A16E94CDE4FB69BD, uuid:43DFD4DA1B4911DCA993C25EC2B58FA4
Create Date                     : 2009:08:19 10:50:39-04:00
Modify Date                     : 2009:10:24 10:41:01-04:00
Metadata Date                   : 2009:10:24 10:41:01-04:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 11151 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Has XFA                         : No
Page Count                      : 1
Creator                         : Adobe InDesign CS3 (5.0.4)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JPZ0066

Navigation menu