Lutron Electronics 0066 Dimmer or Switch User Manual 2
Lutron Electronics Company Inc Dimmer or Switch 2
Contents
- 1. User Manual 1
- 2. User Manual 2
User Manual 2
Installation Instructions Please Read Before Installing English Installation RF Lamp Dimmer RRD-3LD 1. Find a suitable location for the RF Lamp Dimmer. Place the RF Lamp Dimmer in a convenient and accessible location. 120 V Load Specifications: Lamp Dimmer RRD-3LD 50 / 60 Hz Troubleshooting Guide 5. Turn lamp switch ON and operate RF Lamp Dimmer. Symptom Probable Cause and Action Light does not turn ON, but LEDs on Lamp Dimmer are ON Switch on lamp is turned OFF • Turn lamp switch to full ON. Lamp Dimmer Load Type Min. Load Max. Load Incand. 10 W 300 W MLV 10 W / VA 200 W / 300 VA 2. Turn lamp OFF and unplug lamp cord from wall outlet. Dioded lightbulbs • If dioded lightbulbs are being used, replace with non-dioded lightbulbs. Use these instructions to install the model numbers listed above. For system setup instructions and tools visit: www.lutron.com/radiora2 Light does not turn ON, and LEDs on Lamp Dimmer are OFF Circuit breaker is OFF • Turn circuit breaker ON. Lamp Dimmer does not dim properly or lights flicker Lamp has an integral dimmer • Use lamp without an integral dimmer. Important Notes WARNING: To avoid the risk of entrapment, serious injury, or death, these controls must not be used to control equipment which is not visible from every control location or which could create hazardous situations such as entrapment if operated accidentally. Examples of such equipment which must not be operated by these controls include (but are not limited to) motorized gates, garage doors, industrial doors, microwave ovens, heating pads, etc. It is the installer’s responsibility to ensure that the equipment being controlled is visible from every control location and that only suitable equipment is connected to these controls. Failure to do so could result in serious injury or death. Local Operation 3. Plug lamp cord into the RF Lamp Dimmer plug. Environment: Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing. Indoor use only. 4. Plug RF Lamp Dimmer into any standard wall outlet. Cleaning: To clean, wipe with a clean damp cloth. Do not use any chemical cleaning solutions. Lamp Type: Lamp Dimmers are designed for use with incandescent, magnetic low-voltage, and tungsten halogen lightbulbs only. Do not use to control fluorescent lightbulbs or table lamps with an integral dimmer or touch lamps. For lamps with integral 3-way switches, switch should be set to full on position. Lamp Dimmers may not work with dioded lightbulbs. RF Device Placement: RF dimmers, switches, keypads and shades/ drapes must be located within 30 ft (9 m) of an RF signal repeater. For systems without an RF signal repeater, all RF dimmers, switches, keypads and shades/drapes must be located within 30 ft (9 m) of each other. Remote dimmers and switches are not required to be within a specific range. Pressing the Tapswitch on the Lamp Dimmer will alternately turn the lights ON and OFF. The ON level will be the level previously set using the Dimming Rocker to the right of the Tapswitch. The LED that is glowing slightly brighter than the others indicates the level to which the lights will turn ON. Press and hold the top or bottom of the Dimming Rocker to raise or lower the light level. Double-tapping the Tapswitch will turn the lights ON to full. Pressing and holding the Tapswitch for 1/2 second (while ON) activates a 10-second long fade-to-off. Codes: Install in accordance with all local and national electrical codes. Low-voltage Applications: Use Lamp Dimmers with magnetic (core and coil) low-voltage lamps only. Not for use with electronic (solid-state) low-voltage lamps. Operation of a low-voltage circuit with lightbulbs inoperative or removed may result in transformer overheating and premature failure. Lutron strongly recommends the following: • D o not operate low-voltage circuits without operative lightbulbs in place. • R eplace burned-out lightbulbs as quickly as possible. • U se transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent. Cord is not plugged in • Plug cord into wall outlet as shown in Installation. 3-way switch on lamp is not set to full ON • Turn 3-way switch on lamp to full ON NOTICE: To avoid overheating and possible damage to other equipment, do not use to control motor-operated or transformer-supplied appliances or other non-lighting loads. Cordset: The cordset length is 6 ft (1.8 m). Lightbulbs are burned out or not installed • Replace or install lightbulbs. Status LEDs Indicate light level; glow softly as night light when lamp is off Tapswitch Tap on/off; double-tap for full on; press and hold (while ON) for 10-second long fade-to-off Dimming Rocker Press to Brighten Press to Dim Lights don’t turn ON / OFF from Keypad or Integrated Scene Controller Improper programming • Program according to the RadioRA-SR Setup Guide. Out of RF range • Reposition to be within 30 ft (9 m) of controlling keypads or an Integrated Scene Controller. Lamp Dimmer is warm Solid-state control dissipation • Solid-state dimmers internally dissipate about 2% of the total connected load. It is normal for dimmers to feel warm to the touch during operation. Note: Refer to the system Setup Guide for additional troubleshooting suggestions. Returning Lamp Dimmers to Factory Settings Note: Returning a Lamp Dimmer to its Factory Settings will remove the Lamp Dimmer from the system and erase all programming. 1. Triple-tap and hold the tapswitch. DO NOT release after third tap. 2. Continue to hold the tapswitch on the third tap until LEDs start to scroll up and down quickly (approximately 3 seconds). 3. Release the tapswitch and immediately triple-tap it again. The LEDs will scroll up and down slowly. When the LEDs stop scrolling, the Lamp Dimmer has been returned to Factory Settings. Warranty: For warranty information, please see the warranty enclosed with the product, or visit www.lutron.com/resiinfo. ARNING: To avoid risk of electrical shock, do not open, cut cord, or rewire device. Modification of the device can result in personal injury or death. These products may be covered under one or more of the following U.S. patents: 5,248,919; 5,399,940; 5,637,930; 5,838,226; 5,848,054; 5,905,442; 6,687,487; 6,803,728; D439,220 and corresponding foreign patents. U.S. and foreign patents pending. Lutron, RadioRA and the sunburst logo are registered trademarks of Lutron Electronics Co., Inc. ©2009 Lutron Electronics Co., Inc. ARNING: To avoid risk of electrical shock, unplug Lamp Dimmer when changing light bulbs. Changing light bulbs with the power on could result in personal injury or death. Technical Assistance: U.S.A. / Canada: 1.800.523.9466 Mexico: +1.888.235.2910 Other Countries: +1.610.282.3800 24 hours a day, 7 days a week. Note: This is a POLARIZED cord set. It has a polarized plug (one blade is wider than the other) and outlet (one slot is wider than the other). The polarized plug is not intended to be mated with nonpolarized outlets (having both slots the same size). A polarized outlet is intended to mate with a polarized plug in only one way (the longer slot with the wider blade). Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 Made and printed in the U.S.A. 8 / 09 P/N 044-163 Rev. A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Tagged PDF : Yes XMP Toolkit : 3.1-702 Instance ID : uuid:63ee72e2-2000-4d0a-9f6d-de3aaaea4a25 Document ID : adobe:docid:indd:6b20a7da-8e3f-11de-8801-b88f63c3802b Rendition Class : proof:pdf Derived From Instance ID : 6b20a7d9-8e3f-11de-8801-b88f63c3802b Derived From Document ID : adobe:docid:indd:6b20a7d8-8e3f-11de-8801-b88f63c3802b Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:68004B82CC33DD11ACB08D5F57645509, uuid:16D70D6D862EDE11A16E94CDE4FB69BD, uuid:E907F24BDE3BDE11A807D60480892B36, uuid:EA07F24BDE3BDE11A807D60480892B36, uuid:EC07F24BDE3BDE11A807D60480892B36, uuid:ED07F24BDE3BDE11A807D60480892B36, uuid:43DFD4DB1B4911DCA993C25EC2B58FA4 Manifest Reference Document ID : uuid:66004B82CC33DD11ACB08D5F57645509, uuid:15D70D6D862EDE11A16E94CDE4FB69BD, uuid:837E05D7822EDE11A16E94CDE4FB69BD, uuid:867E05D7822EDE11A16E94CDE4FB69BD, uuid:EB07F24BDE3BDE11A807D60480892B36, uuid:8C7E05D7822EDE11A16E94CDE4FB69BD, uuid:43DFD4DA1B4911DCA993C25EC2B58FA4 Create Date : 2009:08:19 10:50:39-04:00 Modify Date : 2009:10:24 10:41:01-04:00 Metadata Date : 2009:10:24 10:41:01-04:00 Creator Tool : Adobe InDesign CS3 (5.0.4) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 11151 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Has XFA : No Page Count : 1 Creator : Adobe InDesign CS3 (5.0.4)EXIF Metadata provided by EXIF.tools