Lutron Electronics 0114 Wireless Dimmer Switch User Manual 0301815a

Lutron Electronics Company Inc Wireless Dimmer Switch 0301815a

Contents

0301815a Instruction sheet

Download: Lutron Electronics 0114 Wireless Dimmer Switch User Manual 0301815a
Mirror Download [FCC.gov]Lutron Electronics 0114 Wireless Dimmer Switch User Manual 0301815a
Document ID2923670
Application IDzzRNppU6YxsidLUlks+5Hg==
Document Description0301815a Instruction sheet
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize25.94kB (324282 bits)
Date Submitted2016-03-09 00:00:00
Date Available2016-03-09 00:00:00
Creation Date2016-02-10 11:29:56
Producing SoftwareAcrobat Distiller 10.1.16 (Windows)
Document Lastmod2016-02-11 09:26:55
Document Title0301815a.pdf
Document CreatorAdobe InDesign CS6 (Windows)
Document Author: ptielmann

GRAFIK T
TM
Installation Instructions
Please Read Before Installing
Installation
P/N 0301815
Rev A
1 Turn OFF power at circuit breaker.
RRT-GH2B
RRT-GH4B
RRT-GH5B
RRT-GH6B
HQRT-GH2B
HQRT-GH4B
HQRT-GH5B
HQRT-GH6B
LED
6b
Shock Hazard. May result in serious injury or death. Turn off power at
! WARNING!
circuit breaker before installing the unit.
120 V~ 50 / 60 Hz
Model Numbers
Hybrid
Keypad 1,2,3
Operation
English
2 Remove wallplate and the switch mounting screws. Leaving all wires attached, carefully pull
Incandescent /
Halogen
MLV 4,5,6,7
Halogen
the switch out from the wall.
Dimmable Electronic
Ballast or Driver 8,9,10
250 W
400 VA
(300 W)
Multi-location – 3-way switches will have insulated
wires connected to three screws plus a green
ground screw. One of the wires is connected to
a screw of a different color (not green) or labeled
COMMON. Tag this wire.
Companion devices
RT-GRDW
For use with RRT– hybrid keypads, dimmers and switches (0.1 A)
HQT-GRDW
For use with HQRT– hybrid keypads, dimmers and switches (0.1 A)
Different-colored
screw
Ground
Tag/Common
4 The switch may have two wires attached to the same screw. Tape these two wires together
before disconnecting. Proceed to disconnect the wires from the switch.
Hybrid Keypad
5 Remove wallplate from the GRAFIK TTM hybrid keypad and any companion device but leave
Line / Hot
wallplate adapter connected.
1. CAUTION: To avoid overheating and possible damage to other equipment, do not use
hybrid keypads to control receptacles or motor-operated appliances.
2. Install in accordance with all national and local electrical codes.
3. When no “grounding means” exist in wallbox, the NEC® allows control without a grounding
connection to be installed as a replacement if 1) a non-metallic, noncombustible faceplate
is used with nonmetallic attachment screws or 2) the circuit is protected by a ground fault
circuit interrupter (GFCI). For this type of installation, cap or remove the green ground wire
on the hybrid keypad, and only use a Lutron® GRAFIK TTM wallplate.
4. GRAFIK TTM controls are not compatible with standard 3-way switches. Use only with GRAFIK
TTM companion devices.
5. GRAFIK TTM Companion devices cannot be used individually but must be used in conjunction
with a GRAFIK TTM hybrid keypad in a multi-location application.
6. In any multi-location circuit, use only one GRAFIK TTM hybrid keypad with up to four
GRAFIK TTM companion devices.
7. Neutral wire connection is optional for GRAFIK TTM hybrid keypad; however, the best
dimming performance will be obtained when the neutral wire is connected. Always cap the
white wire if a neutral wire is not present in wallbox.
8. Return to Factory Settings (Note: Returning a control to the factory settings will remove it
from the system and erase all programming).
Step 1: Triple tap any button on a control. DO NOT release after the third tap.
Step 2: Keep the button pressed on the third tap (for approximately 3 seconds) until the
LEDs on the control start to scroll up and down quickly.
Step 3: Release the button and immediately triple tap the button again. The LEDs on the
control will scroll up and down slowly. Factory settings have been restored.
Blue
Blue
Tag/Common
• Buttons provide scene / zone status
• Buttons are fully programmable
6a
Tag/Common
Companion device(s)
Red
White
120 V~
60 Hz
Connect if using
neutral wire
Green
Black
White
Green
Ground
Ground
Tag/Common
Blue
Green
Load
Neutral
Neutral wire connection is optional for GRAFIK TTM hybrid keypads; however, the best dimming performance will be obtained
when neutral wire is connected.
The companion device is wired differently than a standard 3-way switch. Both the Red wire and the tagged wire are
connected to the same traveler wire.
7 Carefully push wires into the wallbox. Install controls and snap on wallplate.
9 If desired, consider adjusting low-end and high-end trim by using the RadioRA® 2 or
HomeWorks® QS GUI software.
Minimum Load:
Load
Ground
Number of Companion Devices
LED 1, 2
Single-pole
3 LED lamps
80 W
4 LED lamps
120 W
5 LED lamps
160 W
6 LED lamps
200 W
7 LED lamps
240 W
Multi-location
Cut the blue wire at the insulation and cap with the yellow connector.
Load Type
Incandescent / Halogen 3
Application
Neutral
IMPORTANT
Red
8 Turn ON power at circuit breaker.
Blue
DBM:
Dynamic Backlight Management Sensor
Note: DBM should be mounted with an
unobstructed, clear view of the floor. DO
NOT paint or plaster over sensor.
Hybrid Keypad
Blue
Connect the Red wire on the hybrid keypad to the other wire removed from the switch.
Black
Ground
Live
Connect the Black wire on the hybrid keypad to one of the wires removed from the switch. If
you had taped together two wires (see step 4), connect both wires to the Black wire on the
hybrid keypad and remove the tape.
Line / Hot
Green
Ground
Connect the Green ground wire on the hybrid keypad to the Green or bare ground wire in
the wallbox (See Important Notes, number 3).
Red
IMPORTANT NOTICE: FASSTM – Front Accessible Service Switch
To replace lamp(s), power may be conveniently removed by pulling the FASSTM down on the hybrid
keypad. After replacing lamp(s), push the FASSTM back up fully to restore power to the hybrid
keypad. For any procedure, other than routine lamp replacement, power must be turned OFF
at the main electrical panel.
Hybrid Keypad Load-Side (without neutral wire only) 1
Single-pole – Switch will be replaced by a GRAFIK TTM hybrid keypad.
Connect the White wire on the hybrid keypad to the neutral wire in the wallbox
(See Important Notes, number 7).
FASSTM :
Front Accessible Service Switch
Note: FASSTM is not available on
companion devices.
Neutral
Green
Neutral 1
(Connect if using
neutral wire)
6 Install GRAFIK TTM control.
Flexible Control
Load
White
Lutron Electronics Co., Inc.
7200 Suter Road, Coopersburg, PA 18036-1299 USA
Black
Red
Companion device(s)
Red
• Top button toggles local load On/
Off
• All other buttons flutter to indicate
uncommissioned status
• Press to activate a scene or zone
Tag/Common
Recommended LEDs
Important Notes
Off
Hybrid Keypad Line-Side (with or without neutral wire) 1
connectors provided are for copper wires only. For aluminum
IMPORTANT Wire
wires, consult an electrician.
If dimming LED bulbs, they must be Lutron® compatible! For current compatibility and
performance information visit www.lutron.com/LED.
Nightlight
Companion Device
Connect the Green wire on the companion device to the Green or bare ground wire in the wallbox
(See Important Notes, number 3).
Connect the Red wire on the companion device to the tagged wire and to the same color wire
connected to the Red wire on the hybrid keypad .
Connect the Blue wire on the companion device to the remaining wire.
Ground
GRAFIK TTM -GH2B, -GH4B, -GH5B, and -GH6B models can control power boosters / load interfaces if
neutral is used. See Lutron® P / N 369971 and 369985, Compatible Power Boosters and Load Interfaces.
RRT- models are RadioRA® 2 compatible and HQRT- models are HomeWorks® QS compatible.
Not for use with receptacles or appliances (e.g., garbage disposals). See Lutron® Application Note #109 for
compatibility with dimmed receptacles.
Magnetic Low-Voltage Applications: Use with halogen-based lamps only.
UL® listed for use with dimmable ELV transformers, but not recommended because Lutron does not do
system performance testing.
Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating
and premature failure. Lutron strongly recommends the following:
• Do not operate low-voltage circuits without operative lamps in place.
• Replace burned-out lamps as soon as possible.
• Use transformers that incorporate thermal protection or fused transformer primary windings to prevent
transformer failure due to overcurrent.
When using the hybrid keypad to control MLV halogen-based fixtures, the maximum lamp wattage is
determined by the efficiency of the transformer, with 70%–85% as typical. For actual transformer efficiency,
contact either the fixture or transformer manufacturer. The total VA rating of the transformer(s) shall not
exceed the VA rating of the hybrid keypad.
Ten (10) driver maximum.
Includes Lutron® Hi-lume® 1% 2-wire LED drivers, Mark XTM, Tu-Wire®, and POWERSENSE®.
10
Neutral is required for Mark XTM, Tu-Wire®, and POWERSENSE®.
Day
Evening
Single-pole – The switch will have
insulated wires connected to two
screws of the same color plus a green
ground screw.
3.3 A
(400 VA)
Uncommissioned Behavior
Hybrid Keypad
Connect the Green ground wire on the hybrid keypad to the Green or bare ground wire in the
wallbox (See Important Notes, number 3).
Connect the Black wire on the hybrid keypad to the tagged wire removed from the switch.
Connect the Red wire on the hybrid keypad to one of the remaining wires.
Connect the Blue wire on the hybrid keypad to the remaining wire.
Connect the White wire on the hybrid keypad to the neutral wire in the wallbox
(See Important Notes, number 7).
3 Identify switch type.
600 W (Not ganged)
500 W (End of gang)
400 W (Middle of gang)
Multi-location – Lamps can be controlled from multiple locations.
One location will be replaced by a GRAFIK TTM hybrid keypad and the other location(s) by a
GRAFIK TTM companion device. If the neutral wire is not being used, the hybrid keypad can be
wired on the line-side or the load-side. If using the neutral wire, the hybrid keypad must be wired
on the line-side.
See Recommended LEDs.
If using neutral wire, the minimum load required is one LED lamp or Lutron® Hi-lume® 1% 2-wire LED driver.
If using neutral wire, the minimum incandescent/halogen load required is 5 W.
Troubleshooting
Symptom
Possible Solutions
• Push FASSTM up to restore power.
• Turn ON breaker.
1. Lamp and light bar • Replace burned out lamp(s).
LEDs do not turn on. • Check hybrid keypad wiring (See Installation).
• Cycle power to unit by pulling the FASSTM down and back up to fully
restore power. If unit beeps see Symptom 2.
• Check wiring. If neutral wire is connected, ensure that the Black wire is
connected to Live and the Red wire is connected to Load.
2. Unit beeps after
power cycle.
• Check wiring. Ensure that the Blue and Red wires are connected as
specified in Installation.
3. Lamps turn On and • Ensure that the wire connected to the Blue (or Red) wire on the hybrid
hybrid keypad works
keypad is the same as that connected to the Blue (or Red) wire on the
but companion device companion device (See Installation Step 6b).
does not work.
4. Lamps repeatedly
• See Minimum Load and ensure the acceptable minimum load is met.
turn On and Off.
5. Lamps flicker or exhibit • Set low-end trim. See Installation Step 9 for details.
poor dimming range. • See Recommended LEDs.
• Solid-state hybrid keypads internally dissipate about 1% of the total
connected load. It is normal for hybrid keypads to feel warm to the touch
6. Wallplate is warm.
during operation.
• Improper programming. Programming must be done through the system
software.
8. Lamps don’t turn
• Out of RF range. Reposition to be within 30 ft (9 m) of an RF signal repeater.
On / Off from a
• Wires shorted. Make sure the blue terminal is not grounded or shorted to
keypad.
any other wires.
• Wiring error. Ensure wiring matches installation instructions and appropriate
wiring diagram.
9. All LEDs on the hybrid • The hybrid keypad is in factory settings mode and has not been
keypad flash when
configured to work in a system. Follow the steps in the System Setup
any button is pressed. Guide to program.
Customer Assistance: www.lutron.com U.S.A. | Canada | Caribbean: 1.844.LUTRON1 | Mexico: +1.888.235.2910 | Others: +1.610.282.3800 • For warranty details, please visit: www.lutron.com/TechnicalDocumentLibrary/warranty.pdf | For FCC/IC information, please visit: www.lutron.com/fcc-ic
Lutron, C•L, Hi-lume, and Tu-Wire are registered trademarks and FASS, and GRAFIK T are trademarks of Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. POWERSENSE is a registered trademark of Osram Sylvania, Inc. Mark X is a registered trademark of Philips Lighting Electronics N.A., Inc. © 2014-2015 Lutron Electronics Co., Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : ptielmann
Create Date                     : 2016:02:10 11:29:56-05:00
Modify Date                     : 2016:02:11 09:26:55-05:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2016:02:11 09:26:55-05:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:52a0fc6a-91d2-4641-a3b1-c347add8e475
Original Document ID            : xmp.did:F9DAAD7F536BE411BED4A40E3062C96F
Document ID                     : xmp.id:0D91DE5713D0E511A3E8FE9C0949FAAD
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:0C91DE5713D0E511A3E8FE9C0949FAAD
Derived From Document ID        : xmp.did:0C91DE5713D0E511A3E8FE9C0949FAAD
Derived From Original Document ID: xmp.did:F9DAAD7F536BE411BED4A40E3062C96F
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2016:02:10 11:29:24-05:00
Format                          : application/pdf
Creator                         : ptielmann
Title                           : 0301815a.pdf
Producer                        : Acrobat Distiller 10.1.16 (Windows)
Trapped                         : False
Page Count                      : 1
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JPZ0114

Navigation menu