M2Micro 6M2MWM M2micro Remote Unit User Manual linda

M2Micro(Changshu)Co., Ltd. M2micro Remote Unit linda

User manual

Download: M2Micro 6M2MWM M2micro Remote Unit User Manual linda
Mirror Download [FCC.gov]M2Micro 6M2MWM M2micro Remote Unit User Manual linda
Document ID1921845
Application IDglkI7/7JKFHJlKGEH7kgug==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize94.77kB (1184669 bits)
Date Submitted2013-03-20 00:00:00
Date Available2013-03-20 00:00:00
Creation Date2013-02-22 14:48:53
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2013-02-22 14:51:02
Document Titlelinda
Document CreatorAcrobat PDFMaker 9.1 Word 版
Document Author: linda

MRU6000
Installation Guide
Statement
This manual is property of M2Micro (Changshu) Co., Ltd. with all rights reserved.
Any imitation, copying, transcript, or translation without the prior written permission
of the Company is prohibited. Any dissemination of the product in any form or by any
means (electronic, mechanical, photocopying, recording or otherwise) or any use for
any commercial, or profit purpose is also forbidden.
is a registered trademark solely for M2Micro (Changshu) Co., Ltd. All other
trademarks or registered trademarks mentioned herein are owned by their respective
owners.
Product specifications and information referred in this manual are for reference only;
we reserve the right to update relevant content without further notice. For more
information, please visit our website at any time:
http://www.m2micro.com
Unless otherwise specified, this manual is only be used as guidance. While every
attempt has been made to ensure all information in this manual is accurate, the
Company should not be held liable for any error or omission in this document.
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the
following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help..
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions:
1)
This device may not cause harmful interference.
2)
This device must accept any interference received, including interference that may
cause undesired operation.
⚠Caution: Any changes or modifications to this device not explicitly approved by
manufacturer could void your authority to operate this equipment.
Preface
Manual instruction
This Installation Guide describes the hardware features, installation methods and
points for attention during installation.
To avoid possible equipment damage or personal injury before and during the
installation process, please read this manual carefully.
Overview of this guide
Instruction
Chapter
1 Introduction
Outlined the basic functionality and product features.
2 Installation
Describes product installation methods and attentions
A Data sheet
Lists the hardware specifications.
Version
Date
Version
Update description
2011-11-30
R20111130-V1.00
Initial release.
2013-2-22
R20130222-V1.01
Increase FCC certification.
Conventions
Unless otherwise specified, the terms of ”systems”, “equipment”, “products” in the
following parts of this manual refer to the MMR6000 meter reading system.
Two signs are used herein to draw the users’ attention during the operation, with
meanings as follows:
⚠Caution
This icon is used to list advertent items during
operation
and to remind the users of
undesirable consequences due to inaccurate
operation, such as potential damage to the
equipment or otherwise.
 Tips
This icon is to give supplementary explanation for
the operation details described.
Contents
Introduction................................................................................................ 1
1.1
Product Overview ............................................................................................ 1
1.2
Features........................................................................................................... 2
1.3
Demonstration of the type .............................................................................. 2
Installation .................................................................................................. 5
2.1
Packing list ....................................................................................................... 5
2.2
Internal structure ............................................................................................ 5
2.3
MRU6000-BP01 ............................................................................................... 6
2.4
2.5
2.3.1
Product introduction .............................................................................. 6
2.3.2
Product dimension ................................................................................. 6
2.3.3
Product installation ................................................................................ 7
2.3.4
Connection ............................................................................................. 7
MRU6000-EM01 .............................................................................................. 8
2.4.1
Product introduction .............................................................................. 8
2.4.2
Product dimension ................................................................................. 8
2.4.3
Product installation ................................................................................ 8
MRU6000-WM01 ............................................................................................ 9
2.5.1
Product introduction .............................................................................. 9
2.5.2
Product appearance ............................................................................. 10
2.5.3
LEDs introduction ................................................................................. 10
2.5.4
Connection ........................................................................................... 11
1
Introduction
1.1 Product Overview
Automatic Meter Reading (AMR), also called remote meter reading system, is a new
meter reading way to finish meter reading without people on site. Via
communication technology, it can be automatically transferred to the data in
Watt-hour meter the accounting and management center for efficient handling.
Also, it can be provided real-time measurement information to help the users to
optimize their energy supply solutions.
Aiming at AMR application, M2Micro launches its MMR6000 AMR system, which
supports ad hoc network and data collection for various types of meters. It is mainly
made up of MRU6000 terminal units and MCC6000 control units and OMS meter
management system.
The main function of MRU6000 is to collect the electric data through RS485 bus,
and upload it to the control unit with the wireless communication module.
1.2 Features

Modular design, existing meters can be upgraded by attaching wireless AMR
modules.

Support hybrid meter reading, can collect data of water meter, gas meter, etc.
MRU6000 Installation Guide

Based on M2Micro developed chips, MAC and PHY layer can work together
perfectly.

Support 433.92MHz frequency band, with good transportation distance and
penetration.

Support Ad-hoc network, can be deployed to complicate environment.
1.3 Demonstration of the type
MRU6000 series include 3 types.
Model
Scene
MRU6000-BP01
Battery-Powered,
Water-Proof
MRU6000-EM01
Embedded in
Electric Meter
MRU6000-WM01
Wall mounted
Appearance
2
Installation
2.1 Packing list
Make sure that the package contains the following items.
Serial no.
Item
Quantity
MRU6000
This Installation Guide
2.2 Internal structure
The internal structure of MRU6000 is shown in Figure 2.
MRU
Battery
Antenna
M2M6001
DC power
Figure 2 The internal structure of MRU6000
 Antenna: Bi-directional wireless data communication.
 M2M6001: Meter data transfer.
 Battery /DC power: Provide stable current to the whole control unit.
MRU6000 series include 3 types, they are different in appearance, installation and
MRU6000 Installation Guide
application.
2.3 MRU6000-BP01
2.3.1
Product introduction
With sealing structure and battery-power, MRU6000-BP01 is waterproof. It can be
used for measuring the meter which is placed in damp environment for a long time
(Such as water meter or gas meter).
2.3.2
Product dimension
The dimension of MRU6000-BP01 is shown as Figure 3.
Unit: mm
Figure 3 The dimension of MRU6000-BP01
2.3.3
Product installation
MRU6000-BP01 can be wall-mounted. There are 2 mounting holes in the upper left
corner and lower right corner, so that it can be mounted to the wall surface close to
the meter. Or, MRU6000-BP01 can be fastened to the pipeline by pipe clamp.
2Installation
2.3.4
Connection
There are 4 cords used to connect power supply and meter to MRU6000-BP01.
Please refer to the table bellow.
Color
Name
Comments
Red
Anode
Connect positive terminal.
White
Cathode
Connect negative terminal.
Yellow
485+
Connect 485+.
Blue
485-
Connect 485-.
2.4 MRU6000-EM01
2.4.1
Product introduction
MRU6000-EM01 is embedded in a electric meter and powered by it. It can be
applied in the scenario that electric meters are placed in separate rooms.
2.4.2
Product dimension
The dimension of MRU6000-EM01 is shown in Figure 4.
MRU6000 Installation Guide
Unit: mm
Figure 4 The dimension of MRU6000-EM01
2.4.3
Product installation
With a 2x6 pin header connector, MRU6000-EM01 can be plugged into a electric
meter. The four-view and installation diagram are shown as follows.
Figure 5 Four-view
2Installation
Figure 6 Installation diagram
2.5 MRU6000-WM01
2.5.1
Product introduction
MRU6000-WM01 could mount more than one meters, it can be used in
concentrated meter box. MRU6000-WM01 is powered by DC Supply. It can collect
measurement data of meters through RS-485 bus and then send out collected data
by wireless connection.
 Tips:
1. Considering the power supply issue, only multiple electric meters are allowed
to be connected to the same terminal unit. Neither connection of multiple
water meters/gas meters with a same terminal unit, nor connection of hybrid
meters with a same terminal unit , can be supported.
2. MRU6000-WM01 can be connected to more than one electric meter, but all
MRU6000 Installation Guide
meter in the connection must use same communication parameters.
2.5.2
Product appearance
The appearance of MRU6000-WM01 is shown as Figure 7.
Figure 7 The appearance of MRU6000-WM01
2.5.3
LEDs introduction
LED of MRU6000-WM01 is shown in the following figure.
Figure 8 LED of MRU6000-WM01
2Installation
LED
Color
Status
Powe
Red
On
The device is powered on.
Off
The device is powered off.
Flashing
Data is being transmitted or received.
Off
No data transmission.
Status
2.5.4
Green
Comments
Connection
The top panel of MRU6000-WM01 is shown in the following figure.
Figure 11 Top panel of MRU6000-WM01
Port
Comments
ANT
Connector to the wireless antenna.
RS-232
RS-232 connector, it is multiplexed with the RS232
pin headers on the bottom panel.
The bottom panel of MRU6000-WM01 is shown in the following figure.
MRU6000 Installation Guide
Figure 12 Bottom panel of MRU6000-WM01
Port
10
Comments
485A
Positive input port of RS485
485B
Negative input port of RS485
NC
Reserved port.
GND
Grounding port.
232TX
Transmission port of RS232.
232RX
Receiving port of RS232.
POWER DC9V
Power input. Input voltage is 9V DC.
A
Appendix - Data Sheet
MRU6000-BP01
Parameter
Value
Operating Temperature
-40~85°C
Operating Humidity
<95%
Mean Time Between Failures
MTBF > 2x10 hours
Power Consumption
≤1.5W
Distance to connected Meter
Electromechanical meter, distance≤500m;
Electronic meter, distance≤50m
MRU6000-EM01
Parameter
Value
Operating Temperature
-40~85℃
Operating Humidity
<95%
Mean Time Between Failures
MTBF > 2x10 hours
Power Consumption
≤1.5W
11
MRU6000 Installation Guide
MRU6000-WM01
Parameter
Operating Temperature
-40~85℃
Operating Humidity
<95%
Input Voltage
AC220V±20%
Power Consumption
0.6W
Rate of RS485
600bps, 1200bps, 2400bps, 4800bps, 9600bps.
Electrostatic Discharge
8kV
Transient Rapid Pulse Group
1kV
Impulse Withstand Voltage
4kV
Maximum Number of Mounted
Meter
Maximum Number of
Battery-powered Unit
50Hz
250
10
Mean Time Between Failures
MTBF > 2x10 hours
Power Consumption
≤1.5W
Distance to connected Meter
12
Value
Electromechanical meter, distance≤500m;
Electronic meter, distance≤50m

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Modify Date                     : 2013:02:22 14:51:02+08:00
Create Date                     : 2013:02:22 14:48:53+08:00
Metadata Date                   : 2013:02:22 14:51:02+08:00
Creator Tool                    : Acrobat PDFMaker 9.1 Word 版
Document ID                     : uuid:3d97228a-5061-4ee9-8c65-c59bde71069a
Instance ID                     : uuid:c2552372-1193-4313-a644-3128f15189db
Subject                         : 54
Format                          : application/pdf
Title                           : linda
Description                     : 
Creator                         : linda
Producer                        : Adobe PDF Library 9.0
Trapped                         : False
Keywords                        : 
GTS PDFX Version                : PDF/X-1:2001
GTS PDFX Conformance            : PDF/X-1a:2001
Source Modified                 : D:20130222064844
Company                         : 微软中国
Manager                         : 
Comments                        : 
Category                        : 
KSO Product Build Ver           : 2052-8.1.0.3526
Page Layout                     : OneColumn
Page Count                      : 19
Author                          : linda
EXIF Metadata provided by EXIF.tools
FCC ID Filing: R6J6M2MWM

Navigation menu