MARKTRACE MR3872C Equipment & Instrument Status Wireless Sensor User Manual
SHENZHEN MARKTRACE CO., LTD Equipment & Instrument Status Wireless Sensor
User Manual
MR3872C Current Monitoring RFID Tag Instruction (V1.0) SHENZHEN MARKTRACE CO.,LTD Table of Contents 1 Product Intruction .............................................................................................................................................3 1.1 Product Features ........................................................................................................................................1 1.2 Product Description ....................................................................................................................................1 1.3 Applicatios ....................................................................................................................................................1 1.4 Product Image ..............................................................................................................................................4 2 Installation Precautions .......................................................................................................................................4 3 Technical Parameters ..........................................................................................................................................5 4 Application Guide ..........................................................................................................................................5 5 Schematic ............................................................................................................................................................6 6 Common Faults and Exclusion Approach .........................................................................................................8 1Product Instruction 1.1 Product Features 1, Measure up to GB2099.1‐2008 and GB1002‐2008 standard three‐pin plug and socket. More safe and reliable. 2, Power supply by AC , standby battery inside, working above 5 years. 3, Tamper alarm device avoid spite remove.High Precision current measurement, error less than 0.1% 4, Inside 2.4G RFID antenna, transmitting distance 80 meters. 1.2 Product Description 2.4G Current Monitoring RFID Tag MR3872C suit for information assets management of electrical equipments. It adopt RFID technology and current measurement technology. Not only for electrical equipment inventory checking, but also for working status real‐time control and capacity utilization control. MR3872C has two male and female power input/output plug, easy to fixed on equipment. In real‐time to control equipment current. 1.3Applications Laboratory electrical equipment assets supervision Remote room equipment remote control. 1.4Product Image 2Installation Precautions Marktrace does not assume warranty liability for unauthorized removal or change components caused by fault 1、 Handle with care,MR3872C can not withstand strong vibrations, can not withstand the high intensity (more than 1.5 meters) of free fall. 2、 Away from fire.In use, when you notice abnormal odor, Case of overheating or smoke appears.Please turn the power off immediately and pull out the plug from the AC outlet.And contact your dealer or our customer service center.If you continue to use tag,it may have the risk of fire and electrical shock. 3Technical Parameters Items Parameters Electrical Features AC Input Current 0A~10A AC Input Volt 110V ~ 130V/60Hz 220V ~ 240V/50Hz Measuring Accuracy 0A~2A,deviation ±5mA 2A~10A,deviation±10mA Air Discharge 8000V Power Supply Mode AC powered (build‐in back battery) Battery 1200mAh Life Time 5 years RF Features Working Frequency 2.425GHz MAX Output Power 0dBm Modulation Mode GFSK Data Rate 1Mbps Dimension Body:56.02x36.58x27.84mm Cable:235mm Female 405mm Male Weight 170g Environment Features Working Temperature ‐20℃ to +60℃ Store Temperature ‐40℃ to +80℃ 4 Application Guide 4.1. Installation Same using as three-wire power cord.Connect one end of tag to equipment which need monitoring, connect another end to AC power. Meanwhile,tag with 3M side need paste on equipment too.To power the tag. After power-on,LED will blink. Tamper switch Tear 3M 图1 Affixed to the side of the device 图2 Work signal light Insert tag into device Get AC power 图3 图4 4.2. Applications Current monitoring tag can be monitored these information:RMS current on the AC mains,tag tamper alarm, AC is turned on and battery charge status.These information was sent via 2.4G RF, received by the reader. 5 Schematic 6 Common Faults and Exclusion Approach Fault Description Simple Remedy ■ Tag at room temperature, life time can reach 5 years.After 5 years, tag batter is low, should be Low battery replaced.If tag life less than 5 years and battery is low, please contact customer service. ■To power the device, tag LED working.Tag monitoring device current value is zero all the time.Tag status Not properly monitoring info does not appear low battery,but can’t monitoring equipment current any current.In this case,tag inside circuit failure, please contact customer service. Routine Maintenance ■Try to avoid the use of tags under wet conditions FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital, pursuant to Part 15 or the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may casue harmful interference to radio communications, However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --- Reorient or relocate the receiving antenna. --- Increase the separation between the equipment and receiver. --- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --- Consult the dealer or an experienced radio/ TV technician for help. 深圳市华士精成科技有限公司 网址:www.marktrace.com 电话:+86‐755‐26546392 26544205 传真:+86‐755‐26553743 地址:深圳市南山科技园中区高新中一道长园集团 D 栋 3 楼,5 楼。 Marktrace Technology CO.,Ltd. Web:www.marktrace.com Tel: +86‐755‐26546392 26544205 Fax: +86‐755‐26553743 Add: F3&5,Bldg.D,Changyuan New Material, Keyuan Rd, Hi‐Tech Park,NanShan,ShenZhen,China
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Administrator Create Date : 2016:09:23 09:54:29+08:00 Modify Date : 2016:09:23 09:54:29+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Title : Microsoft Word - MR3872C instruction(V1.1).docx Creator : Administrator Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 9.0.0 (Windows) Document ID : uuid:4bc26a01-bf8f-4a27-8bda-98227a33d1ea Instance ID : uuid:71fb45b9-fd61-4b3d-b2f2-663a8ac74bdd Page Count : 9EXIF Metadata provided by EXIF.tools